Reactor-based Search for Axion-Like Particles using CsI(Tl) Detector
Authors:
S. Sahoo,
S. Verma,
M. Mirzakhani,
N. Mishra,
A. Thompson,
S. Maludze,
R. Mahapatra,
M. Platt
Abstract:
Null results for WIMP dark matter have led to increased interest in exploring other dark matter candidates, such as Axions and Axion-Like Particles (ALPs), which also helps in answering the strong CP problem. This experiment achieved a sub-100 DRU (differential-rate-unit, expressed in counts/keV/kg/day) background in the MeV region of interest by employing a combination of active and passive veto…
▽ More
Null results for WIMP dark matter have led to increased interest in exploring other dark matter candidates, such as Axions and Axion-Like Particles (ALPs), which also helps in answering the strong CP problem. This experiment achieved a sub-100 DRU (differential-rate-unit, expressed in counts/keV/kg/day) background in the MeV region of interest by employing a combination of active and passive veto techniques. Such a low background facilitates the search for ALPs with axion-photon coupling $g_{aγγ} > 10^{-6}$ and axion-electron coupling $10^{-8}< g_{aee} < 10^{-4}$ in the 1 keV to 10 MeV mass range. This indicates that the experiment has the capability to constrain the unexplored cosmological triangle in the ALP-photon parameter space for ALPs in the MeV mass range.
△ Less
Submitted 23 July, 2024; v1 submitted 19 July, 2024;
originally announced July 2024.
-
Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches
Authors:
M. J. Wilson,
A. Zaytsev,
B. von Krosigk,
I. Alkhatib,
M. Buchanan,
R. Chen,
M. D. Diamond,
E. Figueroa-Feliciano,
S. A. S. Harms,
Z. Hong,
K. T. Kennard,
N. A. Kurinsky,
R. Mahapatra,
N. Mirabolfathi,
V. Novati,
M. Platt,
R. Ren,
A. Sattari,
B. Schmidt,
Y. Wang,
S. Zatschler,
E. Zhang,
A. Zuniga
Abstract:
Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number…
▽ More
Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.
△ Less
Submitted 24 June, 2024; v1 submitted 2 March, 2024;
originally announced March 2024.
-
Exploring Charge Transport Dynamics in a Cryogenic P-Type Germanium Detector
Authors:
P. Acharya,
M. Fritts,
D. -M. Mei,
G. -J. Wang,
R. Mahapatra,
M. Platt
Abstract:
This study explores the dynamics of charge transport within a cryogenic P-type Ge particle detector, fabricated from a crystal cultivated at the University of South Dakota (USD). By subjecting the detector to cryogenic temperatures and an Am-241 source, we observe evolving charge dynamics and the emergence of cluster dipole states, leading to the impact ionization process at 40 mK. Our analysis fo…
▽ More
This study explores the dynamics of charge transport within a cryogenic P-type Ge particle detector, fabricated from a crystal cultivated at the University of South Dakota (USD). By subjecting the detector to cryogenic temperatures and an Am-241 source, we observe evolving charge dynamics and the emergence of cluster dipole states, leading to the impact ionization process at 40 mK. Our analysis focuses on crucial parameters: the zero-field cross-section of cluster dipole states and the binding energy of these states. For the Ge detector in our investigation, the zero-field cross-section of cluster dipole states is determined to be $8.45 \times 10^{-11}\pm 4.22\times 10^{-12}~cm^2$. Examination of the binding energy associated with cluster dipole states, formed by charge trapping onto dipole states during the freeze-out process, reveals a value of $0.034 \pm 0.0017$ meV. These findings shed light on the intricate charge states influenced by the interplay of temperature and electric field, with potential implications for the sensitivity in detecting low-mass dark matter.
△ Less
Submitted 28 February, 2024;
originally announced February 2024.
-
Applying Superfluid Helium to Light Dark Matter Searches: Demonstration of the HeRALD Detector Concept
Authors:
R. Anthony-Petersen,
A. Biekert,
C. L. Chang,
Y. Chang,
L. Chaplinsky,
A. Dushkin,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
D. Z. Osterman,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani
, et al. (11 additional authors not shown)
Abstract:
The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (e.g. scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD…
▽ More
The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (e.g. scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical "quantum evaporation" signal from $^4$He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype "HeRALD v0.1" detector of $\sim$10~g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. A key result of this work is the measurement of the quantum evaporation channel's gain of $0.15 \pm 0.012$, which will enable $^4$He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145~eV at 5 sigma, which would be sensitive to dark matter masses down to 220~MeV/c$^2$.
△ Less
Submitted 21 July, 2023;
originally announced July 2023.
-
Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light
Authors:
M. Chaudhuri,
G. Agnolet,
V. Iyer,
V. K. S. Kashyap,
M. Lee,
R. Mahapatra,
S. Maludze,
N. Mirabolfathi,
B. Mohanty,
M. Platt,
A. Upadhyay,
S. Sahoo,
S. Verma
Abstract:
We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to…
▽ More
We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
Observation of Time-Dependent Internal Charge Amplification in a Planar Germanium Detector at Cryogenic Temperature
Authors:
P. Acharya,
M. Fritts,
D. -M. Mei,
V. Mandic,
G. -J. Wang,
R. Mahapatra,
M. Platt
Abstract:
For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 minutes after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keV $γ$ rays from a $^{241}$Am source is amplified for a short period of time and then decre…
▽ More
For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 minutes after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keV $γ$ rays from a $^{241}$Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold ($<$ 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.
△ Less
Submitted 15 March, 2023; v1 submitted 29 November, 2022;
originally announced November 2022.
-
Snowmass 2021: Superconducting Sensor Fabrication Capabilities for HEP Science
Authors:
Thomas Cecil,
Clarence L. Chang,
Shannon M. Duff,
Dale Li,
Rupak Mahapatra,
Mark Platt,
Kevin K. Ryu
Abstract:
Superconducting sensors are a key enabling technology for many HEP experiments with advances in sensor capabilities leading directly to expanded science reach. The unique materials and processes required for the fabrication of these sensors makes commercial sourcing impractical in comparison with semiconducting devices. Subsequently, the development and fabrication of new sensors are often perform…
▽ More
Superconducting sensors are a key enabling technology for many HEP experiments with advances in sensor capabilities leading directly to expanded science reach. The unique materials and processes required for the fabrication of these sensors makes commercial sourcing impractical in comparison with semiconducting devices. Subsequently, the development and fabrication of new sensors are often performed at academic cleanrooms supported through HEP basic detector research and/or project funds. While this operational model has been successful to date, we are at a turning point in the history of superconducting electronics, as evidenced by the rapid growth in the field of quantum computing, when scale and sophistication of these sensors can lead to significant progress. In order to achieve this progress and meet the needs of the next generations of HEP experiments, continued support of all stages of the superconducting sensors development pipeline is necessary.
△ Less
Submitted 29 March, 2022;
originally announced March 2022.
-
A novel active veto prototype detector with an inner target for improved rare event searches
Authors:
M. Chaudhuri,
A. Jastram,
G. Agnolet,
S. Banik,
H. Chen,
V. Iyer,
V. K. S. Kashyap,
A. Kubik,
M. Lee,
R. Mahapatra,
S. Maludze,
N. Mirabolfathi,
N. Mishra,
B. Mohanty,
H. Neog,
M. Platt
Abstract:
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detecto…
▽ More
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detector of mass $\sim$10 g was mounted inside the veto detector. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominantly gamma interactions) could be reduced by $>$ 90$\%$, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. During testing at the experimental site the veto detector prototype achieved a baseline resolution of 1.24 $\pm$ 0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147 $\pm$ 2 eV. The detectors were operated at mK temperatures. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.
△ Less
Submitted 22 February, 2022;
originally announced February 2022.
-
Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range
Authors:
R. Ren,
C. Bathurst,
Y. Y. Chang,
R. Chen,
C. W. Fink,
Z. Hong,
N. A. Kurinsky,
N. Mast,
N. Mishra,
V. Novati,
G. Spahn,
H. Meyer zu Theenhausen,
S. L. Watkins,
Z. Williams,
M. J. Wilson,
A. Zaytsev,
D. Bauer,
R. Bunker,
E. Figueroa-Feliciano,
M. Hollister,
L. Hsu,
P. Lukens,
R. Mahapatra,
N. Mirabolfathi,
B. Nebolsky
, et al. (5 additional authors not shown)
Abstract:
We present the design and characterization of a cryogenic phonon-sensitive 1-gram Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2)~eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100~V bias. With a continuous-readout data…
▽ More
We present the design and characterization of a cryogenic phonon-sensitive 1-gram Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2)~eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100~V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2~eV threshold with a trigger rate of the order of 20~Hz. The detector's energy scale is calibrated up to 120~keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.
△ Less
Submitted 20 May, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
Large-mass single-electron-resolution detector for dark matter and neutrino elastic interaction searches
Authors:
V. Iyer,
N. Mirabolfathi,
G. Agnolet,
H. Chen,
A. Jastram,
F. Kadribasic,
V. K. S. Kashyap,
A. Kubik,
M. Lee,
R. Mahapatra,
B. Mohanty,
H. Neog,
M. Platt
Abstract:
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the or…
▽ More
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the order of $10^{-16}$ A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CE$ν$NS like searches.
△ Less
Submitted 3 August, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
Performance of a Large Area Photon Detector For Rare Event Search Applications
Authors:
CPD Collaboration,
C. W. Fink,
S. L. Watkins,
T. Aramaki,
P. L. Brink,
J. Camilleri,
X. Defay,
S. Ganjam,
Yu. G. Kolomensky,
R. Mahapatra,
N. Mirabolfathi,
W. A. Page,
R. Partridge,
M. Platt,
M. Pyle,
B. Sadoulet,
B. Serfass,
S. Zuber
Abstract:
We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-…
▽ More
We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors (QETs) with superconducting critical temperature $T_c=41.5$ $\mathrm{mK}$ to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated $^{55}$Fe X-ray source incident on the center of the detector. The noise equivalent power is measured to be $1\times 10^{-17}$ $\mathrm{W}/\sqrt{\mathrm{Hz}}$ in a bandwidth of $2.7$ $\mathrm{kHz}$. The baseline energy resolution is measured to be $σ_E = 3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.23}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$ (RMS). The detector also has an expected timing resolution of $σ_t = 2.3$ $μ\mathrm{s}$ for $5$ $σ_E$ events.
△ Less
Submitted 11 January, 2021; v1 submitted 29 September, 2020;
originally announced September 2020.
-
Phonon-mediated High-voltage Detector with Background Rejection for Low-mass Dark Matter and Reactor Coherent Neutrino Scattering Experiments
Authors:
H. Neog,
R. Mahapatra,
N. Mirabolfathi,
M. Platt,
A. Jastram,
G. Agnolet,
A. Kubik,
H. Chen,
B. Mohanty
Abstract:
We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of…
▽ More
We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. This new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.
△ Less
Submitted 23 June, 2020;
originally announced June 2020.
-
Cryogenic Dark Matter Search Detector Fabrication Process and Recent Improvements
Authors:
Andrew Jastram,
Rusty Harris,
Rupak Mahapatra,
James Phillips,
Mark Platt,
Kunj Prasad,
Joel Sander,
Sriteja Upadhyayula
Abstract:
A dedicated facility has been commissioned for Cryogenic Dark Matter Search (CDMS) detector fabrication at Texas A&M University (TAMU). The fabrication process has been carefully tuned using this facility and its equipment. Production of successfully tested detectors has been demonstrated. Significant improvements in detector performance have been made using new fabrication methods/equipment and t…
▽ More
A dedicated facility has been commissioned for Cryogenic Dark Matter Search (CDMS) detector fabrication at Texas A&M University (TAMU). The fabrication process has been carefully tuned using this facility and its equipment. Production of successfully tested detectors has been demonstrated. Significant improvements in detector performance have been made using new fabrication methods/equipment and tuning of process parameters.
△ Less
Submitted 26 September, 2014; v1 submitted 1 August, 2014;
originally announced August 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.