-
First search for short-baseline neutrino oscillations at HFIR with PROSPECT
Authors:
J. Ashenfelter,
A. B. Balantekin,
C. Baldenegro,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. Bricco,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. J. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro
, et al. (63 additional authors not shown)
Abstract:
This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of $^{235}$U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton $^6$Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 meter water e…
▽ More
This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of $^{235}$U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton $^6$Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 meter water equivalent overburden. Data collected during 33 live-days of reactor operation at a nominal power of 85 MW yields a detection of 25461 $\pm$ 283 (stat.) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5$σ$ statistical significance within two hours of on-surface reactor-on data-taking. A reactor-model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the Reactor Antineutrino Anomaly at 2.2$σ$ confidence level.
△ Less
Submitted 27 September, 2018; v1 submitted 7 June, 2018;
originally announced June 2018.
-
The PROSPECT Physics Program
Authors:
J. Ashenfelter,
B. Balantekin,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
A. Bowes,
C. D. Bryan,
J. P. Brodsky,
J. J. Cherwinka,
R. Chu,
T. Classen,
K. Commeford,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
J. Dolph,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
B. W. Goddard
, et al. (39 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino detector at distances of 7 - 12 m from the reactor core. It will probe the best-fit point of the $ν_e$ disappearance experiments at 4$σ$ in 1 year and the favored region of the sterile neutrino parameter space at $>$3$σ$ in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV$^{2}$ at 5$σ$ in 3 additional years. The measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Light Collection and Pulse-Shape Discrimination in Elongated Scintillator Cells for the PROSPECT Reactor Antineutrino Experiment
Authors:
J. Ashenfelter,
B. Balantekin,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
A. Bowes,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
K. Commeford,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn
, et al. (41 additional authors not shown)
Abstract:
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been stu…
▽ More
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell long axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. Key design features for optimizing MeV-scale response and background rejection capabilities are identified.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.
-
The Detector System of The Daya Bay Reactor Neutrino Experiment
Authors:
F. P. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
D. Beavis,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
I. Butorov,
D. Cao,
G. F. Cao,
J. Cao,
R. Carr,
W. R. Cen,
W. T. Chan,
Y. L. Chan,
J. F. Chang,
L. C. Chang,
Y. Chang,
C. Chasman,
H. Y. Chen,
H. S. Chen,
M. J. Chen,
Q. Y. Chen
, et al. (310 additional authors not shown)
Abstract:
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\barν_e$ oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of $\rm{sin}^22θ_{13}$ and the effective mass splitting $Δm_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nucl…
▽ More
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\barν_e$ oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of $\rm{sin}^22θ_{13}$ and the effective mass splitting $Δm_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors' baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.
△ Less
Submitted 7 January, 2016; v1 submitted 17 August, 2015;
originally announced August 2015.
-
Background Radiation Measurements at High Power Research Reactors
Authors:
J. Ashenfelter,
B. Balantekin,
C. X. Baldenegro,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
D. Davee,
D. Dean,
G. Deichert,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
S. Fan,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
M. Green,
K. Han
, et al. (36 additional authors not shown)
Abstract:
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are p…
▽ More
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including $γ$-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.
△ Less
Submitted 11 November, 2015; v1 submitted 11 June, 2015;
originally announced June 2015.
-
A Time Projection Chamber for High Accuracy and Precision Fission Cross Section Measurements
Authors:
NIFFTE Collaboration,
M. Heffner,
D. M. Asner,
R. G. Baker,
J. Baker,
S. Barrett,
C. Brune,
J. Bundgaard,
E. Burgett,
D. Carter,
M. Cunningham,
J. Deaven,
D. L. Duke,
U. Greife,
S. Grimes,
U. Hager,
N. Hertel,
T. Hill,
D. Isenhower,
K. Jewell,
J. King,
J. L. Klay,
V. Kleinrath,
N. Kornilov,
R. Kudo
, et al. (25 additional authors not shown)
Abstract:
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4$π$ acceptance for fission fragments and complete…
▽ More
The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4$π$ acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.
-
PROSPECT - A Precision Reactor Oscillation and Spectrum Experiment at Short Baselines
Authors:
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
G. Barclay,
C. Bass,
N. S. Bowden,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
D. Davee,
D. Dean,
G. Deichert,
M. Diwan,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
Y. Efremenko,
S. Fan,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
M. Green,
K. Han,
S. Hans
, et al. (41 additional authors not shown)
Abstract:
Current models of antineutrino production in nuclear reactors predict detection rates and spectra at odds with the existing body of direct reactor antineutrino measurements. High-resolution antineutrino detectors operated close to compact research reactor cores can produce new precision measurements useful in testing explanations for these observed discrepancies involving underlying nuclear or new…
▽ More
Current models of antineutrino production in nuclear reactors predict detection rates and spectra at odds with the existing body of direct reactor antineutrino measurements. High-resolution antineutrino detectors operated close to compact research reactor cores can produce new precision measurements useful in testing explanations for these observed discrepancies involving underlying nuclear or new physics. Absolute measurement of the 235U-produced antineutrino spectrum can provide additional constraints for evaluating the accuracy of current and future reactor models, while relative measurements of spectral distortion between differing baselines can be used to search for oscillations arising from the existence of eV-scale sterile neutrinos. Such a measurement can be performed in the United States at several highly-enriched uranium fueled research reactors using near-surface segmented liquid scintillator detectors. We describe here the conceptual design and physics potential of the PROSPECT experiment, a U.S.-based, multi-phase experiment with reactor-detector baselines of 7-20 meters capable of addressing these and other physics and detector development goals. Current R&D status and future plans for PROSPECT detector deployment and data-taking at the High Flux Isotope Reactor at Oak Ridge National Laboratory will be discussed.
△ Less
Submitted 27 January, 2015; v1 submitted 29 September, 2013;
originally announced September 2013.
-
Assembly and Installation of the Daya Bay Antineutrino Detectors
Authors:
H. R. Band,
R. L. Brown,
R. Carr,
X. C. Chen,
X. H. Chen,
J. J. Cherwinka,
M. C. Chu,
E. Draeger,
D. A. Dwyer,
W. R. Edwards,
R. Gill,
J. Goett,
L. S. Greenler,
W. Q. Gu,
W. S. He,
K. M. Heeger,
Y. K. Heng,
P. Hinrichs,
T. H. Ho,
M. Hoff,
Y. B. Hsiung,
Y. Jin,
L. Kang,
S. H. Kettell,
M. Kramer
, et al. (44 additional authors not shown)
Abstract:
The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay…
▽ More
The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay antineutrino detectors were built in an above-ground facility and deployed side-by-side at three underground experimental sites near and far from the nuclear reactors. This configuration allows the experiment to make a precision measurement of reactor antineutrino disappearance over km-long baselines and reduces relative systematic uncertainties between detectors and nuclear reactors. This paper describes the assembly and installation of the Daya Bay antineutrino detectors.
△ Less
Submitted 6 September, 2013;
originally announced September 2013.
-
Observation of electron-antineutrino disappearance at Daya Bay
Authors:
F. P. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
D. Beavis,
W. Beriguete,
M. Bishai,
S. Blyth,
K. Boddy,
R. L. Brown,
B. Cai,
G. F. Cao,
J. Cao,
R. Carr,
W. T. Chan,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
H. Y. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen
, et al. (246 additional authors not shown)
Abstract:
The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle $θ_{13}$ with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GW$_{\rm th}$ reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day…
▽ More
The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle $θ_{13}$ with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GW$_{\rm th}$ reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day livetime exposure in 55 days, 10416 (80376) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to expected number of antineutrinos at the far hall is $R=0.940\pm 0.011({\rm stat}) \pm 0.004({\rm syst})$. A rate-only analysis finds $\sin^22θ_{13}=0.092\pm 0.016({\rm stat})\pm0.005({\rm syst})$ in a three-neutrino framework.
△ Less
Submitted 2 April, 2012; v1 submitted 7 March, 2012;
originally announced March 2012.
-
A side-by-side comparison of Daya Bay antineutrino detectors
Authors:
Daya Bay Collaboration,
F. P. An,
Q. An,
J. Z. Bai,
A. B. Balantekin,
H. R. Band,
W. Beriguete,
M. Bishai,
S. Blyth,
R. L. Brown,
G. F. Cao,
J. Cao,
R. Carr,
J. F. Chang,
Y. Chang,
C. Chasman,
H. S. Chen,
S. J. Chen,
S. M. Chen,
X. C. Chen,
X. H. Chen,
X. S. Chen,
Y. Chen,
J. J. Cherwinka,
M. C. Chu
, et al. (218 additional authors not shown)
Abstract:
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimenta…
▽ More
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.
△ Less
Submitted 28 February, 2012;
originally announced February 2012.