On the Evaluation of Silicon Photomultipliers for Use as Photosensors in Liquid Xenon Detectors
Abstract: Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT replacements. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection c… ▽ More
Submitted 3 April, 2018; v1 submitted 16 June, 2017; originally announced June 2017.
Comments: This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/13/03/C03041
Journal ref: B. Godfrey, T. Anderson, E. Breedon, J. Cutter, N. Dhaliwal, O.Dalager et al., 2018 On the Evaluation of Silicon Photomultipliers for Use as Photosensors in Liquid Xenon Detectors JINST 13 C03041
-
Observation of the rare $B^0_s\to
μ ^+μ ^-$ decay from the combined analysis of CMS and LHCb dataAbstract: A joint measurement is presented of the branching fractions $B^0_s\to
μ ^+μ ^-$ and $B^0\toμ ^+μ ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ ^+μ ^-$ decay, with a statistical significance exceeding six sta… ▽ MoreSubmitted 17 August, 2015; v1 submitted 17 November, 2014; originally announced November 2014.
Comments: Correspondence should be addressed to cms-and-lhcb-publication-committees@cern.ch
Report number: CERN-PH-EP-2014-220, CMS-BPH-13-007, LHCb-PAPER-2014-049
Journal ref: Nature 522, 68-72 (04 June 2015)
-
The Large Underground Xenon (LUX) Experiment
Abstract: The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100… ▽ More
Submitted 21 November, 2012; v1 submitted 15 November, 2012; originally announced November 2012.
Comments: 50 pages, 16 figures
Journal ref: Nuclear Inst. and Methods in Physics Research A704 (2013) 111 - 126