-
Model Independent Approach of the JUNO $^8$B Solar Neutrino Program
Authors:
JUNO Collaboration,
Jie Zhao,
Baobiao Yue,
Haoqi Lu,
Yufeng Li,
Jiajie Ling,
Zeyuan Yu,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai
, et al. (579 additional authors not shown)
Abstract:
The physics potential of detecting $^8$B solar neutrinos will be exploited at the Jiangmen Underground Neutrino Observatory (JUNO), in a model independent manner by using three distinct channels of the charged-current (CC), neutral-current (NC) and elastic scattering (ES) interactions. Due to the largest-ever mass of $^{13}$C nuclei in the liquid-scintillator detectors and the {expected} low backg…
▽ More
The physics potential of detecting $^8$B solar neutrinos will be exploited at the Jiangmen Underground Neutrino Observatory (JUNO), in a model independent manner by using three distinct channels of the charged-current (CC), neutral-current (NC) and elastic scattering (ES) interactions. Due to the largest-ever mass of $^{13}$C nuclei in the liquid-scintillator detectors and the {expected} low background level, $^8$B solar neutrinos would be observable in the CC and NC interactions on $^{13}$C for the first time. By virtue of optimized event selections and muon veto strategies, backgrounds from the accidental coincidence, muon-induced isotopes, and external backgrounds can be greatly suppressed. Excellent signal-to-background ratios can be achieved in the CC, NC and ES channels to guarantee the $^8$B solar neutrino observation. From the sensitivity studies performed in this work, we show that JUNO, with ten years of data, can reach the {1$σ$} precision levels of 5%, 8% and 20% for the $^8$B neutrino flux, $\sin^2θ_{12}$, and $Δm^2_{21}$, respectively. It would be unique and helpful to probe the details of both solar physics and neutrino physics. In addition, when combined with SNO, the world-best precision of 3% is expected for the $^8$B neutrino flux measurement.
△ Less
Submitted 6 March, 2024; v1 submitted 15 October, 2022;
originally announced October 2022.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Measurement of $σ_{\mathrm{ABS}}$ and $σ_{\mathrm{CX}}$ of $π^+$ on carbon by DUET
Authors:
E. S. Pinzon Guerra,
S. Bhadra,
S. Berkman,
C. Cao,
P. de Perio,
Y. Hayato,
K. Ieki,
M. Ikeda,
Y. Kanazawa,
J. Kim,
P. Kitching,
K. Mahn,
T. Nakaya,
M. Nicholson,
K. Olchanski,
S. Rettie,
H. A. Tanaka,
S. Tobayama,
M. J. Wilking,
T. Yamauchi,
S. Yen,
M. Yokoyama
Abstract:
The DUET Collaboration reports on the measurements of the absorption ($σ_{\mathrm{ABS}}$) and charge exchange ($σ_{\mathrm{CX}}$) cross sections of positively charged pions on carbon nuclei for the momentum range 201.6 MeV$/c$ to 295.1 MeV$/c$. The uncertainties on the absorption and charge exchange cross sections are $\sim$9.5\% and $\sim$18\%, respectively. The results are in good agreement with…
▽ More
The DUET Collaboration reports on the measurements of the absorption ($σ_{\mathrm{ABS}}$) and charge exchange ($σ_{\mathrm{CX}}$) cross sections of positively charged pions on carbon nuclei for the momentum range 201.6 MeV$/c$ to 295.1 MeV$/c$. The uncertainties on the absorption and charge exchange cross sections are $\sim$9.5\% and $\sim$18\%, respectively. The results are in good agreement with previous experiments. A covariance matrix correlating the 5 $σ_{\mathrm{ABS}}$ and 5 $σ_{\mathrm{CX}}$ measured data points is also reported
△ Less
Submitted 17 November, 2016;
originally announced November 2016.
-
Measurement of absorption and charge exchange of $π^+$ on carbon
Authors:
K. Ieki,
E. S. Pinzon Guerra,
S. Berkman,
S. Bhadra,
C. Cao,
P. de Perio,
Y. Hayato,
M. Ikeda,
Y. Kanazawa,
J. Kim,
P. Kitching,
K. Mahn,
T. Nakaya,
M. Nicholson,
K. Olchanski,
S. Rettie,
H. A. Tanaka,
M. J. Wilking,
S. Tobayama,
T. Yamauchi,
S. Yen,
M. Yokoyama
Abstract:
The combined cross section for absorption and charge exchange interactions of positively charged pions with carbon nuclei for the momentum range 200 MeV/c to 300 MeV/c have been measured with the DUET experiment at TRIUMF. The uncertainty is reduced by nearly half compared to previous experiments. This result will be a valuable input to existing models to constrain pion interactions with nuclei.
The combined cross section for absorption and charge exchange interactions of positively charged pions with carbon nuclei for the momentum range 200 MeV/c to 300 MeV/c have been measured with the DUET experiment at TRIUMF. The uncertainty is reduced by nearly half compared to previous experiments. This result will be a valuable input to existing models to constrain pion interactions with nuclei.
△ Less
Submitted 25 June, 2015;
originally announced June 2015.