Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
Authors:
K. Dehmelt,
M. Della Pietra,
H. Muller,
S. E. Tzamarias,
A. White,
S. White,
Z. Zhang,
M. Alviggi,
I. Angelis,
S. Aune,
J. Bortfeldt,
M. Bregant,
F. Brunbauer,
M. T. Camerlingo,
V. Canale,
V. D'Amico,
D. Desforge,
C. Di Donato,
R. Di Nardo,
G. Fanourakis,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo
, et al. (45 additional authors not shown)
Abstract:
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51…
▽ More
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.
△ Less
Submitted 19 March, 2022; v1 submitted 12 March, 2022;
originally announced March 2022.
-
Stopping power of fission fragments in thin Mylar and nickel foils
Authors:
T. Materna,
E. Berthoumieux,
Q. Deshayes,
D. Doré,
M. Kebbiri,
A. Letourneau,
L. Thulliez,
Y. H. Kim,
U. Köster,
X. Ledoux
Abstract:
The energy loss of heavy ions in thin Mylar and nickel foils was measured accurately using fission fragments from $^{239}Pu(n_{th},f)$, mass and energy separated by the Lohengrin separator at ILL. The detection setup, placed at the focal plane of the Lohengrin separator enabled to measure precisely the kinetic energy difference of selected fragments after passing through the sample. From these dat…
▽ More
The energy loss of heavy ions in thin Mylar and nickel foils was measured accurately using fission fragments from $^{239}Pu(n_{th},f)$, mass and energy separated by the Lohengrin separator at ILL. The detection setup, placed at the focal plane of the Lohengrin separator enabled to measure precisely the kinetic energy difference of selected fragments after passing through the sample. From these data, the stopping powers in Mylar and nickel layers were extracted and compared to calculations. Whereas large deviations are observed with SRIM-2013 for Mylar, fairly good agreements are obtained with the semi-empirical approach of Knyazheva et al. and the calculations contained within the DPASS database. In nickel, SRIM-2013 and Knyazheva model are in agreement with our data within about 10 %, while large deviations are observed with DPASS. We used our data to provide updated parameters for the Knyazheva et al. model and rescale DPASS database for nickel and Mylar.
△ Less
Submitted 4 May, 2021;
originally announced May 2021.
-
A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts
Authors:
C. Perez-Lara,
S. Aune,
B. Azmoun,
K. Dehmelt,
A. Deshpande,
W. Fan,
P. Garg,
T. K. Hemmick,
M. Kebbiri,
A. Kiselev,
I. Mandjavidze,
M. L. Purschke,
M. Revolle,
M. Vandenbroucke,
C. Woody
Abstract:
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent p…
▽ More
Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent positional information, the lateral spacing of the straight pads must be significantly smaller than the extent of the charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the charge with a pitch comparable to the size of the charge cloud or even larger. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a uniform detector response without the need for so-called pad response functions, while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag shaped anode patterns optimized for various MPGDs, including GEM, Micromegas, and micro-RWELL and compared this performance to the same detectors equipped with straight pads of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.
△ Less
Submitted 28 January, 2021;
originally announced January 2021.
-
AGATA - Advanced Gamma Tracking Array
Authors:
S. Akkoyun,
A. Algora,
B. Alikhani,
F. Ameil,
G. de Angelis,
L. Arnold,
A. Astier,
A. Ataç,
Y. Aubert,
C. Aufranc,
A. Austin,
S. Aydin,
F. Azaiez,
S. Badoer,
D. L. Balabanski,
D. Barrientos,
G. Baulieu,
R. Baumann,
D. Bazzacco,
F. A. Beck,
T. Beck,
P. Bednarczyk,
M. Bellato,
M. A. Bentley,
G. Benzoni
, et al. (329 additional authors not shown)
Abstract:
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the…
▽ More
The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realization of gamma-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly-segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterization of the crystals was measured and compared with detector-response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximize its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer.
△ Less
Submitted 17 September, 2012; v1 submitted 24 November, 2011;
originally announced November 2011.