-
Mass measurements in the vicinity of the doubly-magic waiting point 56Ni
Authors:
A. Kankainen,
V. -V. Elomaa,
T. Eronen,
D. Gorelov,
J. Hakala,
A. Jokinen,
T. Kessler,
V. S. Kolhinen,
I. D. Moore,
S. Rahaman,
M. Reponen,
J. Rissanen,
A. Saastamoinen,
C. Weber,
J. Äystö
Abstract:
Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu, 58Cu, and 59Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for pr…
▽ More
Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu, 58Cu, and 59Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for proton captures on 55Co, 56Ni, 58Cu, and 59Cu have been measured directly. The precision of the proton-capture Q value for 56Ni(p,gamma)57Cu, Q(p,gamma) = 689.69(51) keV, crucial for astrophysical rp-process calculations, has been improved by a factor of 37. The excitation energy of the proton emitting spin-gap isomer 53Co^m has been measured precisely, Ex = 3174.3(10) keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2- state has been obtained. Except for 53Co, the mass values have been adjusted within a network of 17 frequency ratio measurements between 13 nuclides which allowed also a determination of the reference masses 55Co, 58Ni, and 59Cu.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
A Hot Cavity Laser Ion Source at IGISOL
Authors:
M. Reponen,
T. Kessler,
I. D. Moore,
S. Rothe,
J. Äystö
Abstract:
A development program is underway at the IGISOL (Ion Guide Isotope Separator On-Line) facility, University of Jyvaskyla, to efficiently and selectively produce low-energy radioactive ion beams of silver isotopes and isomers, with a particular interest in N=Z 94Ag. A hot cavity ion source has been installed, based on the FEBIAD (Forced Electron Beam Induced Arc Discharge) technique, combined with…
▽ More
A development program is underway at the IGISOL (Ion Guide Isotope Separator On-Line) facility, University of Jyvaskyla, to efficiently and selectively produce low-energy radioactive ion beams of silver isotopes and isomers, with a particular interest in N=Z 94Ag. A hot cavity ion source has been installed, based on the FEBIAD (Forced Electron Beam Induced Arc Discharge) technique, combined with a titanium:sapphire laser system for selective laser ionization. The silver recoils produced via the heavy-ion fusion-evaporation reaction, 40Ca(58Ni, p3n)94Ag, are stopped in a graphite catcher, diffused, extracted and subsequently ionized using a three-step laser ionization scheme. The performance of the different components of the hot cavity laser ion source is discussed and initial results using stable 107,109Ag are presented.
△ Less
Submitted 8 December, 2008;
originally announced December 2008.
-
Electron-capture branch of 100Tc and tests of nuclear wave functions for double-beta decays
Authors:
S. K. L. Sjue,
D. Melconian,
A. Garcia,
I. Ahmad,
A. Algora,
J. Aysto,
V. -V. Elomaa,
T. Eronen,
J. Hakala,
S. Hoedl,
A. Kankainen,
T. Kessler,
I. D. Moore,
F. Naab,
H. Penttila,
S. Rahaman,
A. Saastamoinen,
H. E. Swanson,
C. Weber,
S. Triambak,
K. Deryckx
Abstract:
We present a measurement of the electron-capture branch of $^{100}$Tc. Our value, $B(\text{EC}) = (2.6 \pm 0.4) \times 10^{-5}$, implies that the $^{100}$Mo neutrino absorption cross section to the ground state of $^{100}$Tc is roughly one third larger than previously thought. Compared to previous measurements, our value of $B(\text{EC})$ prevents a smaller disagreement with QRPA calculations re…
▽ More
We present a measurement of the electron-capture branch of $^{100}$Tc. Our value, $B(\text{EC}) = (2.6 \pm 0.4) \times 10^{-5}$, implies that the $^{100}$Mo neutrino absorption cross section to the ground state of $^{100}$Tc is roughly one third larger than previously thought. Compared to previous measurements, our value of $B(\text{EC})$ prevents a smaller disagreement with QRPA calculations relevant to double-$β$ decay matrix elements.
△ Less
Submitted 22 September, 2008;
originally announced September 2008.
-
A sextupole ion beam guide to improve the efficiency and beam quality at IGISOL
Authors:
P. Karvonen,
I. D. Moore,
T. Sonoda,
T. Kessler,
H. Penttilä,
K. Peräjärvi,
P. Ronkanen,
J. Äystö
Abstract:
The laser ion source project at the IGISOL facility, Jyvaskyla, has motivated the development and construction of an rf sextupole ion beam guide (SPIG) to replace the original skimmer electrode. The SPIG has been tested both off-line and on-line in proton-induced fission, light-ion and heavy-ion induced fusion-evaporation reactions and, in each case, has been directly compared to the skimmer sys…
▽ More
The laser ion source project at the IGISOL facility, Jyvaskyla, has motivated the development and construction of an rf sextupole ion beam guide (SPIG) to replace the original skimmer electrode. The SPIG has been tested both off-line and on-line in proton-induced fission, light-ion and heavy-ion induced fusion-evaporation reactions and, in each case, has been directly compared to the skimmer system. For both fission and light-ion induced fusion, the SPIG has improved the mass-separated ion yields by a factor of typically 4 to 8. Correspondingly, the transmission efficiency of both systems has been studied in simulations with and without space charge effects. The transport capacity of the SPIG has been experimentally determined to be 10^12 ions/s before space charge effects start to take effect. A direct comparison with the simulation has been made using data obtained via light-ion fusion evaporation. Both experiment and simulation show an encouraging agreement as a function of current extracted from the ion guide.
△ Less
Submitted 6 June, 2008;
originally announced June 2008.
-
Off-line studies of the laser ionization of yttrium at the IGISOL facility
Authors:
T. Kessler,
I. D. Moore,
Y. Kudryavtsev,
K. Perajarvi,
A. Popov,
P. Ronkanen,
T. Sonoda,
B. Tordoff,
K. D. A. Wendt,
J. Aysto
Abstract:
A laser ion source is under development at the IGISOL facility, Jyvaskyla, in order to address deficiencies in the ion guide technique. The key elements of interest are those of a refractory nature, whose isotopes and isomers are widely studied using both laser spectroscopic and high precision mass measurement techniques. Yttrium has been the first element of choice for the new laser ion source.…
▽ More
A laser ion source is under development at the IGISOL facility, Jyvaskyla, in order to address deficiencies in the ion guide technique. The key elements of interest are those of a refractory nature, whose isotopes and isomers are widely studied using both laser spectroscopic and high precision mass measurement techniques. Yttrium has been the first element of choice for the new laser ion source. In this work we present a new coupled dye-Ti:Sapphire laser scheme and give a detailed discussion of the results obtained from laser ionization of yttrium atoms produced in an ion guide via joule heating of a filament. The importance of not only gas purity, but indeed the baseline vacuum pressure in the environment outside the ion guide is discussed in light of the fast gas phase chemistry seen in the yttrium system. A single laser shot model is introduced and is compared to the experimental data in order to extract the level of impurities within the gas cell.
△ Less
Submitted 26 September, 2007;
originally announced September 2007.
-
An Ion Guide for the Production of a Low Energy Ion Beam of Daughter Products of $α$-Emitters
Authors:
B. Tordoff,
T. Eronen,
V. V. Elomaa,
S. Gulick,
U. Hager,
P. Karvonen,
T. Kessler,
J. Lee,
I. Moore,
A. Popov,
S. Rahaman,
S. Rinta-Antila,
T. Sonoda,
J. Aysto
Abstract:
A new ion guide has been modeled and tested for the production of a low energy ($\approx$ 40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the $α$-decay of a $^{233}$U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electr…
▽ More
A new ion guide has been modeled and tested for the production of a low energy ($\approx$ 40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the $α$-decay of a $^{233}$U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electric fields and helium gas flow transport the ions through an exit hole for injection into a mass separator. Ion guide efficiencies for the extraction of $^{229}$Th$^{+}$ (0.06%), $^{221}$Fr$^{+}$ (6%), and $^{217}$At$^{+}$ (6%) beams have been measured. A detailed study of the electric field and gas flow influence on the ion guide efficiency is described for two differing electric field configurations.
△ Less
Submitted 22 May, 2006;
originally announced May 2006.