-
Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility
Authors:
V. Alcayne,
A. Kimura,
E. Mendoza,
D. Cano-Ott,
O. Aberle,
F. Álvarez-Velarde,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
V. Bécares,
V. Babiano-Suarez,
M. Bacak,
M. Barbagallo,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Busso,
M. Caamaño,
L. Caballero-Ontanaya,
F. Calviño,
M. Calviani,
A. Casanovas
, et al. (108 additional authors not shown)
Abstract:
The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water react…
▽ More
The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$γ$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
Authors:
J. Balibrea Correa,
J. Lerendegui-Marco,
V. Babiano-Suarez,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
A. Pérez de Rada,
J. Plaza del Olmo,
A. Sánchez-Caballero,
A. Casanovas,
F. Calviño,
S. Valenta,
O. Aberle,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes
, et al. (109 additional authors not shown)
Abstract:
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects…
▽ More
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Recent highlights and prospects on (n,$γ$) measurements at the CERN n_TOF facility
Authors:
J. Lerendegui-Marco,
V. Alcayne,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea-Correa,
A. Casanovas,
C. Domingo-Pardo,
G. de la Fuente,
B. Gameiro,
F. García-Infantes,
I. Ladarescu,
E. Musacchio-Gonzalez,
J. A. Pavón-Rodríguez,
A. Tarifeño-Saldivia,
the n_TOF Collaboration
Abstract:
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming th…
▽ More
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$γ$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.
△ Less
Submitted 24 October, 2023;
originally announced October 2023.
-
New detection systems for an enhanced sensitivity in key stellar (n,$γ$) measurements
Authors:
J. Lerendegui-Marco,
V. Babiano-Suárez,
J. Balibrea-Correa,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
C. Guerrero,
F. Calviño,
A. Casanovas,
U. Köster,
N. M. Chiera,
R. Dressler,
E. A. Maugeri,
D. Schumann,
the n_TOF Collaboration
Abstract:
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and t…
▽ More
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$γ$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$γ$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$γ$).
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility
Authors:
J. Balibrea-Correa,
V. Babiano-Suarez,
J. Lerendegui-Marco,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
J. Plaza,
A. Sánchez-Caballero,
F. Calviño,
A. Casanovas,
C. Guerrero,
S. Heinitz,
U. Köster,
E. A. Maugeri,
R. Dressler,
D. Schumann,
I. Mönch,
S. Cristallo,
C. Lederer-Woods,
O. Aberle
, et al. (112 additional authors not shown)
Abstract:
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along di…
▽ More
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.
△ Less
Submitted 20 February, 2023; v1 submitted 26 January, 2023;
originally announced January 2023.
-
Measurement of the $^{14}$N(n,p)$^{14}$C cross section at the CERN n_TOF facility from sub-thermal energy to 800 keV
Authors:
P. Torres-Sánchez,
J. Praena,
I. Porras,
M. Sabaté-Gilarte,
C. Lederer-Woods,
O. Aberle,
V. Alcayne,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
V. Bécares,
V. Babiano-Suarez,
M. Bacak,
M. Barbagallo,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Busso,
M. Caamaño,
L. Caballero,
F. Calviño,
M. Calviani
, et al. (107 additional authors not shown)
Abstract:
Background: The $^{14}$N(n,p)$^{14}$C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring…
▽ More
Background: The $^{14}$N(n,p)$^{14}$C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. $^{10}$B(n,$α$)$^7$Li and $^{235}$U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809$\pm$0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the $^{14}$N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements
Authors:
N. Patronis,
A. Mengoni,
N. Colonna,
M. Cecchetto,
C. Domingo-Pardo,
O. Aberle,
J. Lerendegui-Marco,
G. Gervino,
M. E. Stamati,
S. Goula,
A. P. Bernardes,
M. Mastromarco,
A. Manna,
R. Vlastou,
C. Massimi,
M. Calviani,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea,
C. Beltrami,
S. Bennett
, et al. (108 additional authors not shown)
Abstract:
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to th…
▽ More
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
Authors:
C. Domingo-Pardo,
V. Babiano-Suarez,
J. Balibrea-Correa,
L. Caballero,
I. Ladarescu,
J. Lerendegui-Marco,
J. L. Tain,
A. Tarifeño-Saldivia,
O. Aberle,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes,
E. Berthoumieux,
M. Boromiza,
D. Bosnar,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
A. Casanovas
, et al. (114 additional authors not shown)
Abstract:
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also prese…
▽ More
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Simultaneous Gamma-Neutron Vision device: a portable and versatile tool for nuclear inspections
Authors:
J. Lerendegui Marco,
V. Babiano-Suárez,
J. Balibrea-Correa,
L. Caballero,
D. Calvo,
I. Ladarescu,
C. Domingo-Pardo
Abstract:
GN-Vision is a novel dual $γ$-ray and neutron imaging system, which aims at simultaneously obtaining information about the spatial origin of $γ$-ray and neutron sources. The proposed device is based on two position sensitive detection planes and exploits the Compton imaging technique for the imaging of $γ$-rays. In addition, spatial distributions of slow- and thermal-neutron sources ($<$100 eV) ar…
▽ More
GN-Vision is a novel dual $γ$-ray and neutron imaging system, which aims at simultaneously obtaining information about the spatial origin of $γ$-ray and neutron sources. The proposed device is based on two position sensitive detection planes and exploits the Compton imaging technique for the imaging of $γ$-rays. In addition, spatial distributions of slow- and thermal-neutron sources ($<$100 eV) are reconstructed by using a passive neutron pin-hole collimator attached to the first detection plane. The proposed gamma-neutron imaging device could be of prime interest for nuclear safety and security applications. The two main advantages of this imaging system are its high efficiency and portability, making it well suited for nuclear applications were compactness and real-time imaging is important. This work presents the working principle and conceptual design of the GN-Vision system based on Monte Carlo simulations and explores its simultaneous $γ$-ray and neutron detection and imaging capabilities for a realistic case of a security inspection where a $^{252}$Cf source is hidden in a neutron moderating container.
△ Less
Submitted 24 November, 2022; v1 submitted 20 July, 2022;
originally announced July 2022.
-
Towards machine learning aided real-time range imaging in proton therapy
Authors:
Jorge Lerendegui-Marco,
Javier Balibrea-Correa,
Víctor Babiano-Súarez,
Ion Ladarescu,
César Domingo-Pardo
Abstract:
In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been designed for neutron-capture nuclear physics experiments, which are characterized by $γ$-ray energies spanning up to 5-6 MeV, rather low $γ$-ray emiss…
▽ More
In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been designed for neutron-capture nuclear physics experiments, which are characterized by $γ$-ray energies spanning up to 5-6 MeV, rather low $γ$-ray emission yields and intense neutron induced $γ$-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high $γ$-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl$_{3}$ crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr$_{3}$. Its high time-resolution (CRT$\sim$500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED module features two detection planes of very large LaCl$_{3}$ monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1MeV $γ$-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10$^{8}$ protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy $γ$-rays is compensated by means of Machine-Learning algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.
△ Less
Submitted 31 January, 2022;
originally announced January 2022.
-
Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques
Authors:
V. Babiano-Suárez,
J. Lerendegui-Marco,
J. Balibrea-Correa,
L. Caballero,
D. Calvo,
I. Ladarescu,
C. Domingo-Pardo,
F. Calviño,
A. Casanovas,
A. Tarifeño-Saldivia,
V. Alcayne,
C. Guerrero,
M. A. Millán-Callado,
M. T. Rodríguez González,
M. Barbagallo,
O. Aberle,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
M. Bacak,
S. Bennett,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown
, et al. (110 additional authors not shown)
Abstract:
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background reje…
▽ More
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,γ$) and $^{56}$Fe($n, γ$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.
△ Less
Submitted 18 December, 2020;
originally announced December 2020.
-
First i-TED demonstrator: a Compton imager with Dynamic Electronic Collimation
Authors:
V. Babiano,
J. Balibrea,
L. Caballero,
D. Calvo,
I. Ladarescu,
J. Lerendegui,
S. Mira Prats,
C. Domingo-Pardo
Abstract:
i-TED consists of both a total energy detector and a Compton camera primarily intended for the measurement of neutron capture cross sections by means of the simultaneous combination of neutron time-of-flight (TOF) and $γ$-ray imaging techniques. TOF allows one to obtain a neutron-energy differential capture yield, whereas the imaging capability is intended for the discrimination of radiative backg…
▽ More
i-TED consists of both a total energy detector and a Compton camera primarily intended for the measurement of neutron capture cross sections by means of the simultaneous combination of neutron time-of-flight (TOF) and $γ$-ray imaging techniques. TOF allows one to obtain a neutron-energy differential capture yield, whereas the imaging capability is intended for the discrimination of radiative background sources, that have a spatial origin different from that of the capture sample under investigation. A distinctive feature of i-TED is the embedded Dynamic Electronic Collimation (DEC) concept, which allows for a trade-off between efficiency and image resolution. Here we report on some general design considerations and first performance characterization measurements made with an i-TED demonstrator in order to explore its $γ$-ray detection and imaging capabilities.
△ Less
Submitted 21 February, 2020; v1 submitted 22 August, 2019;
originally announced August 2019.