Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
D. Bowles,
E. Chanel,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
O. Naviliat-Cuncic,
C. B. Doorenbos,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
V. Kletzl,
J. Krempel,
B. Lauss,
T. Lefort,
A. Lejuez
, et al. (25 additional authors not shown)
Abstract:
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optim…
▽ More
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
A large 'Active Magnetic Shield' for a high-precision experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. Harris,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel
, et al. (26 additional authors not shown)
Abstract:
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static s…
▽ More
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI
Authors:
N. J. Ayres,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
M. Fertl,
P. Flaux,
W. C. Griffith,
P. G. Harris,
N. Hild,
M. Kasprzak,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
P. Mohanmurthy
, et al. (22 additional authors not shown)
Abstract:
We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polari…
▽ More
We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polarized ultracold neutrons stored in vacuum. The dominant systematic uncertainty resulting from magnetic-field gradients was controlled to an unprecedented level of approximately 4 pT/cm using an array of optically-pumped cesium vapor magnetometers and magnetic-field maps independently recorded using a dedicated measurement device. No signature of a theoretically predicted new interaction was found, and we set a new limit on the product of the scalar and the pseudoscalar couplings $g_sg_pλ^2 < 8.3 \times 10^{-28}\,\text{m}^2$ (95% C.L.) in a range of $5\,μ\text{m} < λ< 25\,\text{mm}$ for the monopole-dipole interaction. This new result confirms and improves our previous limit by a factor of 2.7 and provides the current tightest limit obtained with free neutrons.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
C. B. Crawford,
M. Daum,
B. Dechenaux,
S. Emmenegger,
P. Flaux,
W. C. Griffith,
P. G. Harris,
Y. Kermaidic,
K. Kirch,
S. Komposch,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
P. Mohanmurthy,
D. Pais,
F. M. Piegsa
, et al. (13 additional authors not shown)
Abstract:
Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we repor…
▽ More
Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we report on the null result of a demonstration experiment searching for a frequency modulation of the free spin-precession signal of \magHg in a \SI{1}{\micro\tesla} magnetic field. Our search covers the axion mass range $10^{-16}~\textrm{eV} \lesssim m_a \lesssim 10^{-13}~\textrm{eV}$ and achieves a peak sensitivity to the axion-nucleon coupling of $g_{aNN} \approx 3.5 \times 10^{-6}~\textrm{GeV}^{-1}$.
△ Less
Submitted 31 March, 2023; v1 submitted 2 December, 2022;
originally announced December 2022.
-
The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
B. Clement,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
A. Fratangelo,
M. Fertl,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa
, et al. (19 additional authors not shown)
Abstract:
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics.…
▽ More
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1m3 below 100pT, and a field below 600pT in the entire inner volume, up to 4\,cm to the walls. The quasi-static shielding factor at 0.01\,Hz measured with a sinusoidal 2muT peak-to-peak signal is about 100,000 in all three spatial directions and rises fast with frequency to reach 10^8 above 1Hz.
△ Less
Submitted 21 June, 2022;
originally announced June 2022.
-
$n-n'$ Oscillations: Sensitivity of a first UCN beam experiment
Authors:
G. Ban,
J. Chen,
P. -J. Chiu,
B. Clément,
M. Guigue,
T. Jenke,
P. Larue,
T. Lefort,
O. Naviliat-Cuncic,
B. Perriolat,
G. Pignol,
S. Roccia,
W. Saenz-Arevalo,
P. Schmidt-Wellenburg
Abstract:
Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experime…
▽ More
Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experiments, and at larger mass-splitting in passing-through-wall experiments. In this work, we present the expected sensitivity of an experiment searching for neutron hidden neutron oscillations at intermediate mass-splitting via the application of magnetic fields in the range $B_0=30-1100$ $μ$T. This experiment was performed at the Institut-Laue-Langevin using a novel UCN counter to monitor the beam flux. The measured UCN rate and the data collection technique predict a sensitivity on the oscillation time at the level of a couple of seconds.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clément,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
L. Hayen,
N. Hild,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (28 additional authors not shown)
Abstract:
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the large…
▽ More
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.
△ Less
Submitted 3 May, 2022; v1 submitted 16 March, 2021;
originally announced March 2021.
-
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
K. Kirch,
P. A. Koss,
B. Lauss,
T. Lefort,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
D. Rebreyend
, et al. (15 additional authors not shown)
Abstract:
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and v…
▽ More
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped $^{133}$Cs magnetometers and $^{199}$Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of $4\,\times\,10^{-28}\,e\cdot{\rm cm}$ in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.
△ Less
Submitted 9 July, 2021; v1 submitted 2 February, 2021;
originally announced February 2021.
-
The design of the n2EDM experiment
Authors:
N. J. Ayres,
G. Ban,
L. Bienstman,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
P. -J. Chiu,
B. Clément,
C. Crawford,
M. Daum,
B. Dechenaux,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
P. Flaux,
D. Goupillière,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch
, et al. (36 additional authors not shown)
Abstract:
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit…
▽ More
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.
△ Less
Submitted 22 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
A search for neutron to mirror-neutron oscillations
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
R. T. Dinani,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujic,
N. Hild,
K. Kirch,
H. -C. Koch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
A. Leredde
, et al. (18 additional authors not shown)
Abstract:
It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold…
▽ More
It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold neutron storage measurements have investigated neutron to mirror-neutron oscillations and imposed constraints on the theoretical parameters. Recently, further analysis of these ultracold neutron storage experiments has yielded statistically significant anomalous signals that may be interpreted as neutron to mirror-neutron oscillations, assuming nonzero mirror magnetic fields. The neutron electric dipole moment collaboration performed a dedicated search at the Paul Scherrer Institute and found no evidence of neutron to mirror-neutron oscillations. Thereby, the following new lower limits on the oscillation time were obtained: $τ_{nn'} > 352~$s at $B'=0$ (95% C.L.), $τ_{nn'} > 6~\text{s}$ for all $0.4~μ\text{T}<B'<25.7~μ\text{T}$ (95% C.L.), and $τ_{nn'}/\sqrt{\cosβ}>9~\text{s}$ for all $5.0~μ\text{T}<B'<25.4~μ\text{T}$ (95% C.L.), where $β$ is the fixed angle between the applied magnetic field and the local mirror magnetic field which is assumed to be bound to the Earth. These new constraints are the best measured so far around $B'\sim10~μ$T, and $B'\sim20~μ$T.
△ Less
Submitted 19 November, 2020; v1 submitted 23 September, 2020;
originally announced September 2020.
-
Measurement of the permanent electric dipole moment of the neutron
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Burghoff,
E. Chanel,
Z. Chowdhuri,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
B. Franke,
A. Fratangelo,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten
, et al. (59 additional authors not shown)
Abstract:
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19…
▽ More
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
Data blinding for the nEDM experiment at PSI
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
P. G Harris,
Z. Grujić,
N. Hild,
J. Hommet,
B. Lauss,
T. Lefort,
Y. Lemiere,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (20 additional authors not shown)
Abstract:
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.…
▽ More
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.
Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment, as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a fake signal.
We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons of each measurement cycle.
The flexible algorithm is applied twice to the data, to provide different data to various analysis teams. This gives us the option to sequentially apply various blinding offsets for separate analysis steps with independent teams. The subtle modification of the data allows us to modify the algorithm and to produce a re-blinded data set without revealing the blinding secret. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable efforts.
△ Less
Submitted 5 October, 2020; v1 submitted 19 December, 2019;
originally announced December 2019.
-
Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
Z. Chowdhuri,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
N. Hild,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles
, et al. (35 additional authors not shown)
Abstract:
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser…
▽ More
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.
△ Less
Submitted 28 April, 2020; v1 submitted 10 December, 2019;
originally announced December 2019.
-
nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
W. C. Griffith P. G. Harris,
N. Hild,
Y. Kermaidic,
K. Kirch,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
A. Leredde,
P. Mohanmurthy,
M. Musgrave,
O. Naviliat-Cuncic
, et al. (18 additional authors not shown)
Abstract:
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and sh…
▽ More
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is better than 1*10-26 ecm. This contribution summarizes in a single coherent picture the results of the most recent publications of the collaboration.
△ Less
Submitted 9 November, 2018;
originally announced November 2018.
-
The n2EDM experiment at the Paul Scherrer Institute
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. Crawford,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort
, et al. (23 additional authors not shown)
Abstract:
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI…
▽ More
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
△ Less
Submitted 27 February, 2019; v1 submitted 6 November, 2018;
originally announced November 2018.
-
Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations
Authors:
C. Abel,
N. Ayres,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffth,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
A. Leredde,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
M. Rawlik
, et al. (11 additional authors not shown)
Abstract:
The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have…
▽ More
The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have been further analyzed by Berezhiani et al.(2009-2017), and signals, compatible with $n-n'$ oscillations in the presence of mirror magnetic fields, have been reported. The Neutron Electric Dipole Moment Collaboration based at the Paul Scherrer Institute performed a new series of experiments to further test these signals. In this paper, we describe and motivate our choice of run configurations with an optimal filling time of $29~$s, storage times of $180~$s and $380~$s, and applied magnetic fields of $10~μ$T and $20~μ$T. The choice of these run configurations ensures a reliable overlap in settings with the previous efforts and also improves the sensitivity to test the signals. We also elaborate on the technique of normalizing the neutron counts, making such a counting experiment at the ultra-cold neutron source at the Paul Scherrer Institute possible. Furthermore, the magnetic field characterization to meet the requirements of this $n-n'$ oscillation search is demonstrated. Finally, we show that this effort has a statistical sensitivity comparable to the current leading constraints for $n-n'$ oscillations.
△ Less
Submitted 19 December, 2019; v1 submitted 5 November, 2018;
originally announced November 2018.
-
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Authors:
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
W. Heil,
M. Horras,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozel,
J. Krempel,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
G. Pignol,
F. M. Piegsa,
P. Prashanth,
G. Quéméner,
M. Rawlik,
D. Rebreyend
, et al. (9 additional authors not shown)
Abstract:
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of…
▽ More
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Daum,
M. Fairbairn,
V. V. Flambaum,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujić,
P. G. Harris,
N. Hild,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
P. A. Koss,
A. Kozela
, et al. (23 additional authors not shown)
Abstract:
We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range…
▽ More
We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. Our null result sets the first laboratory constraints on the coupling of axion dark matter to gluons, which improve on astrophysical limits by up to 3 orders of magnitude, and also improves on previous laboratory constraints on the axion coupling to nucleons by up to a factor of 40.
△ Less
Submitted 21 August, 2017;
originally announced August 2017.
-
Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute
Authors:
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
P. Geltenbort,
W. C. Griffith,
V. Hélaine,
R. Henneck,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
M. Musgrave,
O. Naviliat-Cuncic,
F. M. Piegsa,
E. Pierre,
G. Pignol,
G. Quéméner
, et al. (10 additional authors not shown)
Abstract:
This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-dep…
▽ More
This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.
△ Less
Submitted 23 June, 2016;
originally announced June 2016.
-
Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy
Authors:
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
V. Hélaine,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière
, et al. (23 additional authors not shown)
Abstract:
We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method…
▽ More
We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCN of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of $1.1~\text{pT/cm}$. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.
△ Less
Submitted 8 September, 2015; v1 submitted 1 June, 2015;
originally announced June 2015.
-
Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field
Authors:
S. Afach,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
Z. Grujic,
P. G. Harris,
W. Heil,
V. Hélaine,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (24 additional authors not shown)
Abstract:
We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to a…
▽ More
We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to an electric dipole moment (EDM) signal, although unlike an EDM this effect is P- and T-conserving. We have used a neutron magnetic resonance EDM spectrometer, featuring a mercury co-magnetometer and an array of external cesium magnetometers, to measure the shift as a function of the applied magnetic field gradient. Our results are in good agreement with theoretical expectations.
△ Less
Submitted 3 August, 2015; v1 submitted 30 March, 2015;
originally announced March 2015.
-
A device for simultaneous spin analysis of ultracold neutrons
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
R. Henneck,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa
, et al. (15 additional authors not shown)
Abstract:
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons.…
▽ More
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.
△ Less
Submitted 12 October, 2015; v1 submitted 24 February, 2015;
originally announced February 2015.
-
A measurement of the neutron to 199Hg magnetic moment ratio
Authors:
S. Afach,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
Z. Grujic,
P. G. Harris,
W. Heil,
V. Hélaine,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
A. Knecht
, et al. (29 additional authors not shown)
Abstract:
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.
△ Less
Submitted 31 October, 2014; v1 submitted 30 October, 2014;
originally announced October 2014.
-
Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute
Authors:
S. Afach,
G. Bison,
K. Bodek,
F. Burri,
Z. Chowdhuri,
M. Daum,
M. Fertl,
B. Franke,
Z. Grujic,
V. Helaine,
R. Henneck,
M. Kasprzak,
K. Kirch,
H. -C. Koch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
M. Meier,
O. Naviliat-Cuncic,
F. M. Piegsa,
G. Pignol,
C. Plonka-Spehr,
P. N. Prashanth
, et al. (12 additional authors not shown)
Abstract:
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magn…
▽ More
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the nEDM measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.
△ Less
Submitted 28 August, 2014;
originally announced August 2014.
-
An Improved Search for the Neutron Electric Dipole Moment
Authors:
M. Burghoff,
A. Schnabel,
G. Ban,
T. Lefort,
Y. Lemiere,
O. Naviliat-Cuncic,
E. Pierre,
G. Quemener,
J. Zejma,
M. Kasprzak,
P. Knowles,
A. Weis,
G. Pignol,
D. Rebreyend,
S. Afach,
G. Bison,
J. Becker,
N. Severijns,
S. Roccia,
C. Plonka-Spehr,
J. Zennerz,
W. Heil,
H. C. Koch,
A. Kraft,
T. Lauer
, et al. (12 additional authors not shown)
Abstract:
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved…
▽ More
A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Authors:
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
P. Fierlinger,
B. Franke,
E. Gutsmiedl,
W. Heil,
R. Henneck,
M. Horras,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Kraft,
A. Knecht,
P. Knowles,
A. Kozela,
T. Lauer,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (16 additional authors not shown)
Abstract:
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in…
▽ More
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.
△ Less
Submitted 30 September, 2010;
originally announced September 2010.
-
New constraints on Lorentz invariance violation from the neutron electric dipole moment
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
P. G. Harris,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
A. Kozela,
F. Kuchler,
B. Lauss,
T. Lefort,
Y. Lemière
, et al. (18 additional authors not shown)
Abstract:
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrai…
▽ More
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrain such a modulation to $d_{12} < 15 \times 10^{-25} \ e\,{\rm cm}$ and $d_{24} < 10 \times 10^{-25} \ e\,{\rm cm}$ at 95~\% C.L. The result translates into a limit on the energy scale for this type of Lorentz violation effect at the level of ${\cal E}_{LV} > 10^{10}$~GeV.
△ Less
Submitted 25 June, 2010;
originally announced June 2010.
-
Neutron to Mirror-Neutron Oscillations in the Presence of Mirror Magnetic Fields
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
K. Bodek,
M. Daum,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
E. Gutsmiedl,
P. G. Harris,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
A. Kozela,
F. Kuchler,
M. Kuźniak,
T. Lauer,
B. Lauss
, et al. (21 additional authors not shown)
Abstract:
We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 1…
▽ More
We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B', UCN losses would be maximal for B = B'. We did not observe any indication for nn' oscillations and placed a lower limit on the oscillation time of tau_{nn'} > 12.0 s at 95% C.L. for any B' between 0 and 12.5 uT.
△ Less
Submitted 18 August, 2009; v1 submitted 26 May, 2009;
originally announced May 2009.
-
Test of Lorentz invariance with spin precession of ultracold neutrons
Authors:
I. Altarev,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
P. Fierlinger,
P. Geltenbort,
K. Green,
M. G. D. van der Grinten,
E. Gutsmiedl,
P. G. Harris,
W. Heil,
R. Henneck,
M. Horras,
P. Iaydjiev,
S. N. Ivanov,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
A. Kozela,
F. Kuchler,
M. Kuźniak
, et al. (21 additional authors not shown)
Abstract:
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This resu…
▽ More
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms is reported. %57 No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field $b_{\bot} < 2 \times 10^{-20} {\rm eV}$ (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron $|g_n| < 0.3 $eV/$c^2$ m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit $|g_n| < 3 \times 10^{-4} $eV/$c^2 $m.
△ Less
Submitted 23 July, 2009; v1 submitted 20 May, 2009;
originally announced May 2009.
-
An Improved Neutron Electric Dipole Moment Experiment
Authors:
M. Kuźniak,
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
M. Daum,
K. Eberhardt,
P. Fierlinger,
E. Gutsmiedl,
G. Hampel,
W. Heil,
R. Henneck,
N. Khomutov,
K. Kirch,
St. Kistryn,
S. Knappe-Grueneberg,
A. Knecht,
P. Knowles,
J. V. Kratz,
T. Lauer,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (19 additional authors not shown)
Abstract:
A new measurement of the neutron EDM, using Ramsey's method of separated oscillatory fields, is in preparation at the new high intensity source of ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland (PSI). The existence of a non-zero nEDM would violate both parity and time reversal symmetry and, given the CPT theorem, might lead to a discovery of new CP violating mech…
▽ More
A new measurement of the neutron EDM, using Ramsey's method of separated oscillatory fields, is in preparation at the new high intensity source of ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland (PSI). The existence of a non-zero nEDM would violate both parity and time reversal symmetry and, given the CPT theorem, might lead to a discovery of new CP violating mechanisms. Already the current upper limit for the nEDM (|d_n|<2.9E-26 e.cm) constrains some extensions of the Standard Model.
The new experiment aims at a two orders of magnitude reduction of the experimental uncertainty, to be achieved mainly by (1) the higher UCN flux provided by the new PSI source, (2) better magnetic field control with improved magnetometry and (3) a double chamber configuration with opposite electric field directions.
The first stage of the experiment will use an upgrade of the RAL/Sussex/ILL group's apparatus (which has produced the current best result) moved from Institut Laue-Langevin to PSI. The final accuracy will be achieved in a further step with a new spectrometer, presently in the design phase.
△ Less
Submitted 5 August, 2008; v1 submitted 30 June, 2008;
originally announced June 2008.
-
Centrality dependence of the thermal excitation-energy deposition in 8-15 GeV/c hadron-Au reactions
Authors:
R. A. Soltz,
R. J. Newby,
J. L. Klay,
M. Heffner,
L. Beaulieu,
T. Lefort,
K. Kwiatkowski,
V. E. Viola
Abstract:
The excitation energy per residue nucleon (E*/A) and fast and thermal light particle multiplicities are studied as a function of centrality defined as the number of grey tracks emitted N_grey and by the mean number of primary hadron-nucleon scatterings <nu> and mean impact parameter <b> extracted from it. The value of E*/A and the multiplicities show an increase with centrality for all systems,…
▽ More
The excitation energy per residue nucleon (E*/A) and fast and thermal light particle multiplicities are studied as a function of centrality defined as the number of grey tracks emitted N_grey and by the mean number of primary hadron-nucleon scatterings <nu> and mean impact parameter <b> extracted from it. The value of E*/A and the multiplicities show an increase with centrality for all systems, 14.6 GeV p-Au and 8.0 GeV pi-Au and pbar-Au collisions, and the excitation energy per residue nucleon exhibits a uniform dependence on N_grey.
△ Less
Submitted 9 January, 2009; v1 submitted 8 May, 2008;
originally announced May 2008.
-
A direct experimental limit on neutron -- mirror neutron oscillations
Authors:
G. Ban,
K. Bodek,
M. Daum,
R. Henneck,
S. Heule,
M. Kasprzak,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Knecht,
P. Knowles,
M. Kuzniak,
T. Lefort,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
C. Plonka,
G. Quemener,
M. Rebetez,
D. Rebreyend,
S. Roccia,
G. Rogel,
M. Tur,
A. Weis,
J. Zejma,
G. Zsigmond
Abstract:
In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron ${\rm n'}$, could potentially mix and undergo ${\rm nn'}$ oscillations. The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the ${\rm n'}$-amplitude in the n-wavefunction…
▽ More
In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron ${\rm n'}$, could potentially mix and undergo ${\rm nn'}$ oscillations. The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the ${\rm n'}$-amplitude in the n-wavefunction and, thus, suppress its observability. We report an experimental comparison of ultracold neutron storage in a trap with and without superimposed magnetic field. No influence of the magnetic field is found and, assuming negligible mirror magnetic fields, a limit on the oscillation time $τ_{\rm nn'} > 103$ s (95% C.L.) is derived.
△ Less
Submitted 13 September, 2007; v1 submitted 16 May, 2007;
originally announced May 2007.
-
Cooling Dynamics in Multi-fragmentation processes
Authors:
T. X. Liu,
W. G. Lynch,
M. J. van Goethem,
X. D. Liu,
R. Shomin,
W. P. Tan,
M. B. Tsang,
G. Verde,
A. Wagner,
H. F. Xi,
H. S. Xu,
W. A. Friedman,
S. R. Souza,
R. Donangelo,
L. Beaulieu,
B. Davin,
Y. Larochelle,
T. Lefort,
R. T. de Souza,
R. Yanez,
V. E. Viola,
R. J. Charity,
L. G. Sobotka
Abstract:
Fragment energy spectra of neutron deficient isotopes are significantly more energetic than those of neutron rich isotopes of the same element. This trend is well beyond what can be expected for the bulk multi-fragmentation of an equilibrated system. It can be explained, however, if some of these fragments are emitted earlier through the surface of the system while it is expanding and cooling.
Fragment energy spectra of neutron deficient isotopes are significantly more energetic than those of neutron rich isotopes of the same element. This trend is well beyond what can be expected for the bulk multi-fragmentation of an equilibrated system. It can be explained, however, if some of these fragments are emitted earlier through the surface of the system while it is expanding and cooling.
△ Less
Submitted 20 February, 2006;
originally announced February 2006.
-
Comparison of mid-velocity fragment formation with projectile-like decay
Authors:
S. Hudan,
R. Alfaro,
B. Davin,
Y. Larochelle,
H. Xu,
L. Beaulieu,
T. Lefort,
R. Yanez,
R. T. de Souza,
R. J. Charity,
L. G. Sobotka,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander Molen,
A. Wagner,
H. F. Xi
Abstract:
The characteristics of intermediate mass fragments (IMFs: 3<=Z<=20) produced in mid-peripheral and central collisions are compared. We compare IMFs detected at mid-velocity with those evaporated from the excited projectile-like fragment (PLF*). On average, the IMFs produced at mid-velocity are larger in atomic number, exhibit broader transverse velocity distributions, and are more neutron-rich a…
▽ More
The characteristics of intermediate mass fragments (IMFs: 3<=Z<=20) produced in mid-peripheral and central collisions are compared. We compare IMFs detected at mid-velocity with those evaporated from the excited projectile-like fragment (PLF*). On average, the IMFs produced at mid-velocity are larger in atomic number, exhibit broader transverse velocity distributions, and are more neutron-rich as compared to IMFs evaporated from the PLF*. In contrast, comparison of mid-velocity fragments associated with mid-peripheral and central collisions reveals that their characteristics are remarkably similar despite the difference in impact parameter. The characteristics of mid-velocity fragments are consistent with low-density formation of the fragments. Neutron deficient isotopes of even Z elements manifest higher kinetic energies than heavier isotopes of the same element for both PLF* and mid-velocity emission. This result may be due to the decay of long-lived excited states in the field of the emitting system.
△ Less
Submitted 24 January, 2005;
originally announced January 2005.
-
Interplay of initial deformation and Coulomb proximity on nuclear decay
Authors:
S. Hudan,
R. Alfaro,
L. Beaulieu,
B. Davin,
Y. Larochelle,
T. Lefort,
V. E. Viola,
H. Xu,
R. Yanez,
R. T. de Souza,
R. J. Charity,
L. G. Sobotka,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander,
Molen A. Wagner,
H. F. Xi
Abstract:
Alpha particles emitted from an excited projectile-like fragment (PLF*) formed in a peripheral collision of two intermediate-energy heavy ions exhibit a strong preference for emission towards the target-like fragment (TLF). The interplay of the initial deformation of the PLF* caused by the reaction, Coulomb proximity, and the rotation of the PLF* results in the observed anisotropic angular distr…
▽ More
Alpha particles emitted from an excited projectile-like fragment (PLF*) formed in a peripheral collision of two intermediate-energy heavy ions exhibit a strong preference for emission towards the target-like fragment (TLF). The interplay of the initial deformation of the PLF* caused by the reaction, Coulomb proximity, and the rotation of the PLF* results in the observed anisotropic angular distribution. Changes in the shape of the angular distribution with excitation energy are interpreted as being the result of forming more elongated initial geometries in the more peripheral collisions.
△ Less
Submitted 14 May, 2004;
originally announced May 2004.
-
Nucleon-induced reactions at intermediate energies: New data at 96 MeV and theoretical status
Authors:
V. Blideanu,
F. R. Lecolley,
J. F. Lecolley,
T. Lefort,
N. Marie,
A. Atac,
G. Ban,
B. Bergenwall,
J. Blomgren,
S. Dangtip,
K. Elmgren,
Ph. Eudes,
Y. Foucher,
A. Guertin,
F. Haddad,
A. Hildebrand,
C. Johansson,
O. Jonsson,
M. Kerveno,
T. Kirchner,
J. Klug,
Ch. Le Brun,
C. Lebrun,
M. Louvel,
P. Nadel-Turonski
, et al. (10 additional authors not shown)
Abstract:
Double-differential cross sections for light charged particle production (up to A=4) were measured in 96 MeV neutron-induced reactions, at TSL laboratory cyclotron in Uppsala (Sweden). Measurements for three targets, Fe, Pb, and U, were performed using two independent devices, SCANDAL and MEDLEY. The data were recorded with low energy thresholds and for a wide angular range (20-160 degrees). The…
▽ More
Double-differential cross sections for light charged particle production (up to A=4) were measured in 96 MeV neutron-induced reactions, at TSL laboratory cyclotron in Uppsala (Sweden). Measurements for three targets, Fe, Pb, and U, were performed using two independent devices, SCANDAL and MEDLEY. The data were recorded with low energy thresholds and for a wide angular range (20-160 degrees). The normalization procedure used to extract the cross sections is based on the np elastic scattering reaction that we measured and for which we present experimental results. A good control of the systematic uncertainties affecting the results is achieved. Calculations using the exciton model are reported. Two different theoretical approches proposed to improve its predictive power regarding the complex particle emission are tested. The capabilities of each approach is illustrated by comparison with the 96 MeV data that we measured, and with other experimental results available in the literature.
△ Less
Submitted 28 April, 2004;
originally announced April 2004.
-
Effects of in-medium cross-sections and optical potential on thermal-source formation in p+197Au reactions at 6.2-14.6 GeV/c
Authors:
S. Turbide,
L. Beaulieu,
P. Danielewicz,
V. E. Viola,
R. Roy,
K. Kwiatkowski,
W. -C. Hsi,
G. Wang,
T. Lefort,
D. S. Bracken,
H. Breuer,
E. Cornell,
F. Gimeno-Nogues,
D. S. Ginger,
S. Gushue,
R. Huang,
R. Korteling,
W. G. Lynch,
K. B. Morley,
E. Ramakrishnan,
L. P. Remsberg,
D. Rowland,
M. B. Tsang,
H. Xi,
S. J. Yennello
Abstract:
Effects of in-medium cross-sections and of optical potential on pre-equilibrium emission and on formation of a thermal source are investigated by comparing the results of transport simulations with experimental results from the p+{197}Au reaction at 6.2-14.6 GeV/c. The employed transport model includes light composite-particle production and allows for inclusion of in-medium particle-particle cr…
▽ More
Effects of in-medium cross-sections and of optical potential on pre-equilibrium emission and on formation of a thermal source are investigated by comparing the results of transport simulations with experimental results from the p+{197}Au reaction at 6.2-14.6 GeV/c. The employed transport model includes light composite-particle production and allows for inclusion of in-medium particle-particle cross-section reduction and of momentum dependence in the particle optical-potentials. Compared to the past, the model incorporates improved parameterizations of elementary high-energy processes. The simulations indicate that the majority of energy deposition occurs during the first ~25 fm/c of a reaction. This is followed by a pre-equilibrium emission and readjustment of system density and momentum distribution toward an equilibrated system. Good agreement with data, on the d/p and t/p yield ratios and on the residue mass and charge numbers, is obtained at the time of ~ 65 fm/c from the start of a reaction, provided reduced in-medium cross-sections and momentum-dependent optical potentials are employed in the simulations. By then, the pre-equilibrium nucleon and cluster emission, as well as mean-field readjustments, drive the system to a state of depleted average density, rho/rho_{0} ~ 1/4-1/3 for central collisions, and low-to-moderate excitation, i.e. the region of nuclear liquid-gas phase transition.
△ Less
Submitted 20 February, 2004;
originally announced February 2004.
-
Isospin Diffusion in Heavy Ion Reactions
Authors:
M. B. Tsang,
T. X. Liu,
L. Shi,
P. Danielewicz,
C. K. Gelbke,
X. D. Liu,
W. G. Lynch,
W. P. Tan,
G. Verde,
A. Wagner,
H. S. Xu,
W. A. Friedman,
L. Beaulieu,
B. Davin,
R. T. de Souza,
Y. Larochelle,
T. Lefort,
R. Yanez,
V. E. Viola Jr,
R. J. Charity,
L. G. Sobotka
Abstract:
Using symmetric 112Sn+112Sn, 124Sn+124Sn collisions as references, we probe isospin diffusion in peripheral asymmetric 112Sn+124Sn, 124Sn+112Sn systems at incident energy of E/A=50 MeV. Isoscaling analyses imply that the quasi-projectile and quasi-target in these collisions do not achieve isospin equilibrium, permitting an assessment of the isospin transport rates. We find that comparisons betwe…
▽ More
Using symmetric 112Sn+112Sn, 124Sn+124Sn collisions as references, we probe isospin diffusion in peripheral asymmetric 112Sn+124Sn, 124Sn+112Sn systems at incident energy of E/A=50 MeV. Isoscaling analyses imply that the quasi-projectile and quasi-target in these collisions do not achieve isospin equilibrium, permitting an assessment of the isospin transport rates. We find that comparisons between isospin sensitive experimental and theoretical observables, using suitably chosen scaled ratios, permit investigation of the density dependence of the asymmetry term of the nuclear equation of state.
△ Less
Submitted 25 October, 2003;
originally announced October 2003.
-
Coulomb proximity decay: A clock for measuring the particle emission time scale
Authors:
S. Hudan,
A. S. Botvina,
R. Alfaro,
L. Beaulieu,
B. Davin,
Y. Larochelle,
T. Lefort,
V. E. Viola,
H. Xu,
R. Yanez,
R. T. de Souza,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander Molen,
A. Wagner,
H. F. Xi,
R. J. Charity,
L. G. Sobotka
Abstract:
A new method to examine the time scale of particle emission from hot nuclei is explored. Excited projectile-like and target-like fragments decay as they separate following a peripheral heavy-ion collision. Their mutual Coulomb influence results in an anisotropic angular distribution of emitted particles, providing a measure of the particle emission time scale. Predictions of a schematic evaporat…
▽ More
A new method to examine the time scale of particle emission from hot nuclei is explored. Excited projectile-like and target-like fragments decay as they separate following a peripheral heavy-ion collision. Their mutual Coulomb influence results in an anisotropic angular distribution of emitted particles, providing a measure of the particle emission time scale. Predictions of a schematic evaporation model are presented and compared to experimental data.
△ Less
Submitted 4 September, 2003; v1 submitted 28 August, 2003;
originally announced August 2003.
-
Excitation and decay of projectile-like fragments formed in dissipative peripheral collisions at intermediate energies
Authors:
R. Yanez,
S. Hudan,
R. Alfaro,
B. Davin,
Y. Larochelle,
H. Xu,
L. Beaulieu,
T. Lefort,
V. E. Viola,
R. T. de Souza,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander Molen,
A. Wagner,
H. F. Xi,
R. J. Charity,
L. G. Sobotka
Abstract:
Projectile-like fragments (PLF:15<=Z<=46) formed in peripheral and mid-peripheral collisions of 114Cd projectiles with 92Mo nuclei at E/A=50 MeV have been detected at very forward angles, 2.1 deg.<=theta_lab<=4.2 deg. Calorimetric analysis of the charged particles observed in coincidence with the PLF reveals that the excitation of the primary PLF is strongly related to its velocity damping. Furt…
▽ More
Projectile-like fragments (PLF:15<=Z<=46) formed in peripheral and mid-peripheral collisions of 114Cd projectiles with 92Mo nuclei at E/A=50 MeV have been detected at very forward angles, 2.1 deg.<=theta_lab<=4.2 deg. Calorimetric analysis of the charged particles observed in coincidence with the PLF reveals that the excitation of the primary PLF is strongly related to its velocity damping. Furthermore, for a given V_PLF*, its excitation is not related to its size, Z_PLF*. For the largest velocity damping, the excitation energy attained is large, approximately commensurate with a system at the limiting temperature
△ Less
Submitted 2 June, 2003;
originally announced June 2003.
-
Fragment Production in Non-central Collisions of Intermediate Energy Heavy Ions
Authors:
B. Davin,
R. Alfaro,
H. Xu,
L. Beaulieu,
Y. Larochelle,
T. Lefort,
R. Yanez,
S. Hudan,
A. L. Caraley,
R. T. de Souza,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander Molen,
A. Wagner,
H. F. Xi,
C. K. Gelbke,
R. J. Charity,
L. G. Sobotka
Abstract:
The defining characteristics of fragment emission resulting from the non-central collision of 114Cd ions with 92Mo target nuclei at E/A = 50 MeV are presented. Charge correlations and average relative velocities for mid-velocity fragment emission exhibit significant differences when compared to standard statistical decay. These differences associated with similar velocity dissipation are indicat…
▽ More
The defining characteristics of fragment emission resulting from the non-central collision of 114Cd ions with 92Mo target nuclei at E/A = 50 MeV are presented. Charge correlations and average relative velocities for mid-velocity fragment emission exhibit significant differences when compared to standard statistical decay. These differences associated with similar velocity dissipation are indicative of the influence of the entrance channel dynamics on the fragment production process.
△ Less
Submitted 23 November, 2002;
originally announced November 2002.
-
Similarity of fragment characteristics at mid-velocity for mid-peripheral and central collisions
Authors:
S. Hudan,
R. Alfaro,
B. Davin,
Y. Larochelle,
H. Xu,
L. Beaulieu,
T. Lefort,
V. E. Viola,
R. Yanez,
R. T. de Souza,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander Molen,
A. Wagner,
H. F. Xi,
C. K. Gelbke,
R. J. Charity,
L. G. Sobotka
Abstract:
The characteristics, in particular the isotopic composition (N/Z), of intermediate mass fragments (IMF : 3<=Z<=20) produced near the center-of-mass in mid-peripheral and central collisions of 114Cd ions with 92Mo target nuclei at E/A=50 MeV are compared to that of IMFs emitted from the projectile-like fragment (PLF) in mid-peripheral collisions. IMFs produced at mid-velocities are on average lar…
▽ More
The characteristics, in particular the isotopic composition (N/Z), of intermediate mass fragments (IMF : 3<=Z<=20) produced near the center-of-mass in mid-peripheral and central collisions of 114Cd ions with 92Mo target nuclei at E/A=50 MeV are compared to that of IMFs emitted from the projectile-like fragment (PLF) in mid-peripheral collisions. IMFs produced at mid-velocities are on average larger in atomic number, more energetic, and more neutron-rich as compared to IMFs emitted from the PLF. In contrast, the characteristics of mid-velocity IMFs in central collisions and mid-peripheral collisions are comparable.
△ Less
Submitted 21 December, 2004; v1 submitted 5 October, 2002;
originally announced October 2002.
-
Isotope yields from central 112,124Sn+112,124Sn collisions, dynamical emission?
Authors:
T. X. Liu,
X. D. Liu,
M. J. van Goethem,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
G. Verde,
A. Wagner,
H. F. Xi,
H. S. Xu,
M. Colonna,
M. Di Toro,
M. Zielinska-Pfabe,
H. H. Wolter,
L. Beaulieu,
B. Davin,
Y. Larochelle,
T. Lefort,
R. T. de Souza,
R. Yanez,
V. E. Viola,
R. J. Charity,
L. G. Sobotka
Abstract:
Isotopic yields for light particles and intermediate mass fragments have been measured for 112Sn+112Sn, 112Sn+124Sn, 124Sn+112Sn and 124Sn+124Sn central collisions at E/A=50 MeV and compared with predictions of stochastic mean field calculations. These calculations predict a sensitivity of the isotopic distributions to the density dependence of the asymmetry term of the nuclear equation of state…
▽ More
Isotopic yields for light particles and intermediate mass fragments have been measured for 112Sn+112Sn, 112Sn+124Sn, 124Sn+112Sn and 124Sn+124Sn central collisions at E/A=50 MeV and compared with predictions of stochastic mean field calculations. These calculations predict a sensitivity of the isotopic distributions to the density dependence of the asymmetry term of the nuclear equation of state. However, the secondary decay of the excited fragments modifies significantly the primary isotopic distributions and these modifications are rather sensitive to theoretical uncertainties in the excitation energies of the hot fragments. The predicted final isotope distributions are narrower than the experimental data and the sensitivity of the predicted yields to the density dependence of the asymmetry term is reduced.
△ Less
Submitted 2 October, 2002;
originally announced October 2002.
-
Tracking the phase-transition energy in disassembly of hot nuclei
Authors:
C. B. Das,
S. Das Gupta,
L. Beaulieu,
T. Lefort,
K. Kwiatkowski,
V. E. Viola,
S. J. Yennello,
L. Pienkowski,
R. G. Korteling,
H. Breuer
Abstract:
In efforts to determine phase transitions in the disintegration of highly excited heavy nuclei, a popular practice is to parametrise the yields of isotopes as a function of temperature in the form $Y(z)=z^{-τ}f(z^σ(T-T_0))$, where $Y(z)$'s are the measured yields and $τ, σ$ and $T_0$ are fitted to the yields. Here $T_0$ would be interpreted as the phase transition temperature. For finite systems…
▽ More
In efforts to determine phase transitions in the disintegration of highly excited heavy nuclei, a popular practice is to parametrise the yields of isotopes as a function of temperature in the form $Y(z)=z^{-τ}f(z^σ(T-T_0))$, where $Y(z)$'s are the measured yields and $τ, σ$ and $T_0$ are fitted to the yields. Here $T_0$ would be interpreted as the phase transition temperature. For finite systems such as those obtained in nuclear collisions, this parametrisation is only approximate and hence allows for extraction of $T_0$ in more than one way. In this work we look in detail at how values of $T_0$ differ, depending on methods of extraction. It should be mentioned that for finite systems, this approximate parametrisation works not only at the critical point, but also for first order phase transitions (at least in some models). Thus the approximate fit is no guarantee that one is seeing a critical phenomenon. A different but more conventional search for the nuclear phase transition would look for a maximum in the specific heat as a function of temperature $T_2$. In this case $T_2$ is interpreted as the phase transition temperature. Ideally $T_0$ and $T_2$ would coincide. We invesigate this possibility, both in theory and from the ISiS data, performing both canonical ($T$) and microcanonical ($e=E^*/A$) calculations. Although more than one value of $T_0$ can be extracted from the approximate parmetrisation, the work here points to the best value from among the choices. Several interesting results, seen in theoretical calculations, are borne out in experiment.
△ Less
Submitted 24 June, 2002;
originally announced June 2002.
-
Measurements of sideward flow around the balance energy
Authors:
INDRA collaboration,
D. Cussol,
T. Lefort,
J. Péter
Abstract:
Sideward flow values have been determined with the INDRA multidetector for Ar+Ni, Ni+Ni and Xe+Sn systems studied at GANIL in the 30 to 100 A.MeV incident energy range. The balance energies found for Ar+Ni and Ni+Ni systems are in agreement with previous experimental results and theoretical calculations. Negative sideward flow values have been measured. The possible origins of such negative valu…
▽ More
Sideward flow values have been determined with the INDRA multidetector for Ar+Ni, Ni+Ni and Xe+Sn systems studied at GANIL in the 30 to 100 A.MeV incident energy range. The balance energies found for Ar+Ni and Ni+Ni systems are in agreement with previous experimental results and theoretical calculations. Negative sideward flow values have been measured. The possible origins of such negative values are discussed. They could result from a more important contribution of evaporated particles with respect to the contribution of promptly emitted particles at mid-rapidity. But effects induced by the methods used to reconstruct the reaction plane cannot be totally excluded. Complete tests of these methods are presented and the origins of the ``auto-correlation'' effect have been traced back. For heavy fragments, the observed negative flow values seem to be mainly due to the reaction plane reconstruction methods. For light charged particles, these negative values could result from the dynamics of the collisions and from the reaction plane reconstruction methods as well. These effects have to be taken into account when comparisons with theoretical calculations are done.
△ Less
Submitted 13 November, 2001;
originally announced November 2001.
-
Caloric curve of 8 GeV/c negative pion and antiproton + Au reactions
Authors:
A. Ruangma,
R. Laforest,
E. Martin,
E. Ramakrishnan,
D. J. Rowland,
M. Veselsky,
E. M. Winchester,
S. J. Yennello,
L. Beaulieu,
W. -c. Hsi,
K. Kwiatkowski,
T. Lefort,
V. E. Viola,
A. Botvina,
R. G. Korteling,
L. Pienkowski,
H. Breuer,
S. Gushue,
L. P. Remsberg
Abstract:
The relationship between nuclear temperature and excitation energy of hot nuclei formed by 8 GeV/c negative pion and antiproton beams incident on 197Au has been investigated with the ISiS 4-pidetector array at the BNL AGS accelerator. The double-isotope-ratio technique was used to calculate the temperature of the hot system. The two thermometers used (p/d-3He/4He) and (d/t-3He/4He) are in agreem…
▽ More
The relationship between nuclear temperature and excitation energy of hot nuclei formed by 8 GeV/c negative pion and antiproton beams incident on 197Au has been investigated with the ISiS 4-pidetector array at the BNL AGS accelerator. The double-isotope-ratio technique was used to calculate the temperature of the hot system. The two thermometers used (p/d-3He/4He) and (d/t-3He/4He) are in agreement below E*/A ~ 7 MeV when corrected for secondary decay. Comparison of these caloric curves to those from other experiments shows some differences that may be attributable to instrumentation and analysis procedures. The caloric curves from this experiment are also compared with the predictions from the SMM multifragmentation model.
△ Less
Submitted 4 October, 2001;
originally announced October 2001.
-
Fragment Isospin as a Probe of Heavy-Ion Collisions
Authors:
H. Xu,
R. Alfaro,
B. Davin,
L. Beaulieu,
Y. Larochelle,
T. Lefort,
R. Yanez,
R. T. de Souza,
T. X. Liu,
X. D. Liu,
W. G. Lynch,
R. Shomin,
W. P. Tan,
M. B. Tsang,
A. Vander Molen,
A. Wagner,
H. F. Xi,
C. K. Gelbke,
R. J. Charity,
L. G. Sobotka,
A. S. Botvina
Abstract:
Isotope ratios of fragments produced at mid-rapidity in peripheral and central collisions of 114Cd ions with 92Mo and 98Mo target nuclei at E/A = 50 MeV are compared. Neutron-rich isotopes are preferentially produced in central collisions as compared to peripheral collisions. The influence of the size (A), density, N/Z, E*/A, and Eflow/A of the emitting source on the measured isotope ratios was…
▽ More
Isotope ratios of fragments produced at mid-rapidity in peripheral and central collisions of 114Cd ions with 92Mo and 98Mo target nuclei at E/A = 50 MeV are compared. Neutron-rich isotopes are preferentially produced in central collisions as compared to peripheral collisions. The influence of the size (A), density, N/Z, E*/A, and Eflow/A of the emitting source on the measured isotope ratios was explored by comparison with a statistical model (SMM). The mid-rapidity region associated with peripheral collisions does not appear to be neutron-enriched relative to central collisions.
△ Less
Submitted 16 July, 2001;
originally announced July 2001.
-
The liquid to vapor phase transition in excited nuclei
Authors:
J. B. Elliott,
L. G. Moretto,
L. Phair,
G. J. Wozniak,
T. Lefort,
L. Beaulieu,
K. Kwiatkowski,
W. -C. Hsi,
L. Pienkowski,
H. Breuer,
R. G. Korteling,
R. Laforest,
E. Martin,
E. Ramakrishnan,
D. Rowland,
A. Ruangma,
V. E. Viola,
E. Winchester,
S. J. Yennello
Abstract:
For many years it has been speculated that excited nuclei would undergo a liquid to vapor phase transition. For even longer, it has been known that clusterization in a vapor carries direct information on the liquid- vapor equilibrium according to Fisher's droplet model. Now the thermal component of the 8 GeV/c pion + 197Au multifragmentation data of the ISiS Collaboration is shown to follow the…
▽ More
For many years it has been speculated that excited nuclei would undergo a liquid to vapor phase transition. For even longer, it has been known that clusterization in a vapor carries direct information on the liquid- vapor equilibrium according to Fisher's droplet model. Now the thermal component of the 8 GeV/c pion + 197Au multifragmentation data of the ISiS Collaboration is shown to follow the scaling predicted by Fisher's model, thus providing the strongest evidence yet of the liquid to vapor phase transition.
△ Less
Submitted 2 May, 2001; v1 submitted 11 April, 2001;
originally announced April 2001.
-
Breakup time scale studied in the 8 GeV/c pi- + 197Au reaction
Authors:
L. Pienkowski,
K. Kwiatkowski,
T. Lefort,
W. -c. Hsi,
L. Beaulieu,
A. Botvina,
B. Back,
H. Breuer,
S. Gushue,
R. G. Korteling,
R. Laforest,
E. Martin,
E. Ramakrishnan,
L. P. Remsberg,
D. Rowland,
A. Ruangma,
V. E. Viola,
E. Winchester,
S. J. Yennello
Abstract:
Experimental data from the reaction of an 8.0 GeV/c pi- beam incident on a 197Au target have been analyzed in order to investigate the integrated breakup time scale for hot residues. Alpha-particle energy spectra and particle angular distributions supported by a momentum tensor analysis suggest that at large excitation energy, above 3-5 MeV/nucleon, light-charged particles are emitted prior to o…
▽ More
Experimental data from the reaction of an 8.0 GeV/c pi- beam incident on a 197Au target have been analyzed in order to investigate the integrated breakup time scale for hot residues. Alpha-particle energy spectra and particle angular distributions supported by a momentum tensor analysis suggest that at large excitation energy, above 3-5 MeV/nucleon, light-charged particles are emitted prior to or at the same time as the emission of the heavy fragments. Comparison with the SMM and GEMINI models is presented. A binary fission-like mechanism fits the experimental data at low excitation energies, but seems unable to reproduce the data at excitation energies above 3-5 MeV/nucleon.
△ Less
Submitted 16 September, 2000;
originally announced September 2000.
-
Effect of the intermediate velocity emissions on the quasi-projectile properties for the Ar+Ni system at 95 A.MeV
Authors:
D. Dore,
Ph. Buchet,
J. L. Charvet,
R. Dayras,
L. Nalpas,
D. Cussol,
T. Lefort,
R. Legrain,
C. Volant,
G. Auger,
Ch. O. Bacri,
N. Bellaize,
F. Bocage,
R. Bougault,
B. Bouriquet,
R. Brou,
A. Chbihi,
J. Colin,
A. Demeyer,
D. Durand,
J. D. Frankland,
E. Galichet,
E. Genouin-Duhamel,
E. Gerlic,
D. Guinet
, et al. (25 additional authors not shown)
Abstract:
The quasi-projectile (QP) properties are investigated in the Ar+Ni collisions at 95 A.MeV taking into account the intermediate velocity emission. Indeed, in this reaction, between 52 and 95 A.MeV bombarding energies, the number of particles emitted in the intermediate velocity region is related to the overlap volume between projectile and target. Mean transverse energies of these particles are f…
▽ More
The quasi-projectile (QP) properties are investigated in the Ar+Ni collisions at 95 A.MeV taking into account the intermediate velocity emission. Indeed, in this reaction, between 52 and 95 A.MeV bombarding energies, the number of particles emitted in the intermediate velocity region is related to the overlap volume between projectile and target. Mean transverse energies of these particles are found particularly high. In this context, the mass of the QP decreases linearly with the impact parameter from peripheral to central collisions whereas its excitation energy increases up to 8 A.MeV. These results are compared to previous analyses assuming a pure binary scenario.
△ Less
Submitted 6 September, 2000;
originally announced September 2000.