-
Strong Interaction Physics at the Luminosity Frontier with 22 GeV Electrons at Jefferson Lab
Authors:
A. Accardi,
P. Achenbach,
D. Adhikari,
A. Afanasev,
C. S. Akondi,
N. Akopov,
M. Albaladejo,
H. Albataineh,
M. Albrecht,
B. Almeida-Zamora,
M. Amaryan,
D. Androić,
W. Armstrong,
D. S. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
A. Austregesilo,
H. Avagyan,
T. Averett,
C. Ayerbe Gayoso,
A. Bacchetta,
A. B. Balantekin,
N. Baltzell,
L. Barion
, et al. (419 additional authors not shown)
Abstract:
This document presents the initial scientific case for upgrading the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab) to 22 GeV. It is the result of a community effort, incorporating insights from a series of workshops conducted between March 2022 and April 2023. With a track record of over 25 years in delivering the world's most intense and precise multi-GeV electron…
▽ More
This document presents the initial scientific case for upgrading the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab) to 22 GeV. It is the result of a community effort, incorporating insights from a series of workshops conducted between March 2022 and April 2023. With a track record of over 25 years in delivering the world's most intense and precise multi-GeV electron beams, CEBAF's potential for a higher energy upgrade presents a unique opportunity for an innovative nuclear physics program, which seamlessly integrates a rich historical background with a promising future. The proposed physics program encompass a diverse range of investigations centered around the nonperturbative dynamics inherent in hadron structure and the exploration of strongly interacting systems. It builds upon the exceptional capabilities of CEBAF in high-luminosity operations, the availability of existing or planned Hall equipment, and recent advancements in accelerator technology. The proposed program cover various scientific topics, including Hadron Spectroscopy, Partonic Structure and Spin, Hadronization and Transverse Momentum, Spatial Structure, Mechanical Properties, Form Factors and Emergent Hadron Mass, Hadron-Quark Transition, and Nuclear Dynamics at Extreme Conditions, as well as QCD Confinement and Fundamental Symmetries. Each topic highlights the key measurements achievable at a 22 GeV CEBAF accelerator. Furthermore, this document outlines the significant physics outcomes and unique aspects of these programs that distinguish them from other existing or planned facilities. In summary, this document provides an exciting rationale for the energy upgrade of CEBAF to 22 GeV, outlining the transformative scientific potential that lies within reach, and the remarkable opportunities it offers for advancing our understanding of hadron physics and related fundamental phenomena.
△ Less
Submitted 24 August, 2023; v1 submitted 13 June, 2023;
originally announced June 2023.
-
Streaming readout for next generation electron scattering experiment
Authors:
Fabrizio Ameli,
Marco Battaglieri,
Vladimir V. Berdnikov,
Mariangela Bondì,
Sergey Boyarinov,
Nathan Brei,
Laura Cappelli,
Andrea Celentano,
Tommaso Chiarusi,
Raffaella De Vita,
Cristiano Fanelli,
Vardan Gyurjyan,
David Lawrence,
Patrick Moran,
Paolo Musico,
Carmelo Pellegrino,
Alessandro Pilloni,
Ben Raydo,
Carl Timmer,
Maurizio Ungaro,
Simone Vallarino
Abstract:
Current and future experiments at the high intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard `triggered' data acquisition systems with a new, simplified and outperforming scheme. `Streaming readout' (SRO…
▽ More
Current and future experiments at the high intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard `triggered' data acquisition systems with a new, simplified and outperforming scheme. `Streaming readout' (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper we report results of the on-beam validation of the Jefferson Lab SRO framework. We exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.
△ Less
Submitted 7 February, 2022;
originally announced February 2022.
-
Streaming Readout of the CLAS12 Forward Tagger Using TriDAS and JANA2
Authors:
Fabrizio Ameli,
Marco Battaglieri,
Mariangela Bondí,
Andrea Celentano,
Sergey Boyarinov,
Nathan Brei,
Tommaso Chiarusi,
Raffaella De Vita,
Cristiano Fanelli,
Var-dan Gyurjyan,
David Lawrence,
Paolo Musico,
Carmelo Pellegrino,
Ben Raydo,
Simone Vallarino
Abstract:
An effort is underway to develop streaming readout data acquisition system for the CLAS12 detector in Jefferson Lab's experimental Hall-B. Successful beam tests were performed in the spring and summer of 2020 using a 10GeV electron beam from Jefferson Lab's CEBAF accelerator. The prototype system combined elements of the TriDAS and CODA data acquisition systems with the JANA2 analysis/reconstructi…
▽ More
An effort is underway to develop streaming readout data acquisition system for the CLAS12 detector in Jefferson Lab's experimental Hall-B. Successful beam tests were performed in the spring and summer of 2020 using a 10GeV electron beam from Jefferson Lab's CEBAF accelerator. The prototype system combined elements of the TriDAS and CODA data acquisition systems with the JANA2 analysis/reconstruction framework. This successfully merged components that included an FPGA stream source, a distributed hit processing system, and software plugins that allowed offline analysis written in C++ to be used for online event filtering. Details of the system design and performance are presented.
△ Less
Submitted 2 June, 2021; v1 submitted 22 April, 2021;
originally announced April 2021.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
A Radial Time Projection Chamber for $α$ detection in CLAS at JLab
Authors:
R. Dupré,
S. Stepanyan,
M. Hattawy,
N. Baltzell,
K. Hafidi,
M. Battaglieri,
S. Bueltmann,
A. Celentano,
R. De Vita,
A. El Alaoui,
L. El Fassi,
H. Fenker,
K. Kosheleva,
S. Kuhn,
P. Musico,
S. Minutoli,
M. Oliver,
Y. Perrin,
B. Torayev,
E. Voutier
Abstract:
A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS)…
▽ More
A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS) cannot track the low energy $α$ particles. In 2009, we carried out measurements using the CLAS spectrometer supplemented by the RTPC positioned directly around a gaseous $^4$He target, allowing a detection threshold as low as 12$\sim$MeV for $^4$He. This article discusses the design, principle of operation, calibration methods and the performances of this RTPC.
△ Less
Submitted 30 January, 2018; v1 submitted 30 June, 2017;
originally announced June 2017.
-
Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini
, et al. (136 additional authors not shown)
Abstract:
Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.
Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.
△ Less
Submitted 4 November, 2016; v1 submitted 1 November, 2016;
originally announced November 2016.
-
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab
Authors:
M. Battaglieri,
A. Bersani,
B. Caiffi,
A. Celentano,
R. De Vita,
E. Fanchini,
L. Marsicano,
P. Musico,
M. Osipenko,
F. Panza,
M. Ripani,
E. Santopinto,
M. Taiuti,
V. Bellini,
M. Bondí,
M. De Napoli,
F. Mammoliti,
E. Leonora,
N. Randazzo,
G. Russo,
M. Sperduto,
C. Sutera,
F. Tortorici,
N. Baltzell,
M. Dalton
, et al. (79 additional authors not shown)
Abstract:
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This proposal presents the MeV-GeV DM discovery potential for a $\sim$1 m$^3$ segmented CsI(Tl) scintillator detector placed downstream of the Hall A beam-dump at Jefferson Lab, receiving up to 10$^{22}$ electrons-on-target (EOT) in 285 days. This experiment (Beam-Dump eXperiment or BDX) would be sensitive to elast…
▽ More
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This proposal presents the MeV-GeV DM discovery potential for a $\sim$1 m$^3$ segmented CsI(Tl) scintillator detector placed downstream of the Hall A beam-dump at Jefferson Lab, receiving up to 10$^{22}$ electrons-on-target (EOT) in 285 days. This experiment (Beam-Dump eXperiment or BDX) would be sensitive to elastic DM-electron and to inelastic DM scattering at the level of 10 counts per year, reaching the limit of the neutrino irreducible background. The distinct signature of a DM interaction will be an electromagnetic shower of few hundreds of MeV, together with a reduced activity in the surrounding active veto counters. A detailed description of the DM particle $χ$ production in the dump and subsequent interaction in the detector has been performed by means of Monte Carlo simulations. Different approaches have been used to evaluate the expected backgrounds: the cosmogenic background has been extrapolated from the results obtained with a prototype detector running at INFN-LNS (Italy), while the beam-related background has been evaluated by GEANT4 Monte Carlo simulations. The proposed experiment will be sensitive to large regions of DM parameter space, exceeding the discovery potential of existing and planned experiments in the MeV-GeV DM mass range by up to two orders of magnitude.
△ Less
Submitted 5 July, 2016;
originally announced July 2016.
-
Test of the CLAS12 RICH large scale prototype in the direct proximity focusing configuration
Authors:
N. Baltzell,
L. Barion,
F. Benmokhtar,
W. Brooks,
E. Cisbani,
M. Contalbrigo,
A. El Alaoui,
K. Hafidi,
M. Hoek,
V. Kubarovsky,
L. Lagamba,
V. Lucherini,
R. Malaguti,
M. Mirazita,
R. A. Montgomery,
A. Movsisyan,
P. Musico,
A. Orlandi,
D. Orecchini,
L. L. Pappalardo,
R. Perrino,
J. Phillips,
S. Pisano,
P. Rossi,
S. Squerzanti
, et al. (3 additional authors not shown)
Abstract:
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-pack…
▽ More
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-packed and high-segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). We report here the results of the tests of a large scale prototype of the RICH detector performed with the hadron beam of the CERN T9 experimental hall for the direct detection configuration. The tests demonstrated that the proposed design provides the required pion-to-kaon rejection factor of 1:500 in the whole momentum range.
△ Less
Submitted 1 February, 2016; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab
Authors:
BDX Collaboration,
M. Battaglieri,
A. Celentano,
R. De Vita,
E. Izaguirre,
G. Krnjaic,
E. Smith,
S. Stepanyan,
A. Bersani,
E. Fanchini,
S. Fegan,
P. Musico,
M. Osipenko,
M. Ripani,
E. Santopinto,
M. Taiuti,
P. Schuster,
N. Toro,
M. Dalton,
A. Freyberger,
F. -X. Girod,
V. Kubarovsky,
M. Ungaro,
G. De Cataldo,
R. De Leo
, et al. (61 additional authors not shown)
Abstract:
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This Letter of Intent presents the MeV-GeV DM discovery potential for a 1 m$^3$ segmented plastic scintillator detector placed downstream of the beam-dump at one of the high intensity JLab experimental Halls, receiving up to 10$^{22}$ electrons-on-target (EOT) in a one-year period. This experiment (Beam-Dump eXperi…
▽ More
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably unexplored. This Letter of Intent presents the MeV-GeV DM discovery potential for a 1 m$^3$ segmented plastic scintillator detector placed downstream of the beam-dump at one of the high intensity JLab experimental Halls, receiving up to 10$^{22}$ electrons-on-target (EOT) in a one-year period. This experiment (Beam-Dump eXperiment or BDX) is sensitive to DM-nucleon elastic scattering at the level of a thousand counts per year, with very low threshold recoil energies ($\sim$1 MeV), and limited only by reducible cosmogenic backgrounds. Sensitivity to DM-electron elastic scattering and/or inelastic DM would be below 10 counts per year after requiring all electromagnetic showers in the detector to exceed a few-hundred MeV, which dramatically reduces or altogether eliminates all backgrounds. Detailed Monte Carlo simulations are in progress to finalize the detector design and experimental set up. An existing 0.036 m$^3$ prototype based on the same technology will be used to validate simulations with background rate estimates, driving the necessary R$\&$D towards an optimized detector. The final detector design and experimental set up will be presented in a full proposal to be submitted to the next JLab PAC. A fully realized experiment would be sensitive to large regions of DM parameter space, exceeding the discovery potential of existing and planned experiments by two orders of magnitude in the MeV-GeV DM mass range.
△ Less
Submitted 11 June, 2014;
originally announced June 2014.
-
Comparison of Fast Amplifiers for Diamond Detectors
Authors:
M. Osipenko,
S. Minutoli,
P. Musico,
M. Ripani,
B. Caiffi,
A. Balbi,
G. Ottonello,
S. Argirò,
S. Beolè,
N. Amapane,
M. Masera,
G. Mila
Abstract:
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a nu…
▽ More
The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a number of commercial amplifiers designed for diamond detector readout to identify the best solution for a particular application. This application required a deposited energy threshold below 100 keV and timing resolution of the order of 200 ps at 200 keV. None of tested amplifiers satisfies these requirements. The best solution to such application found to be the Cividec C6 amplifier, which allows 100 keV minimal threshold, but its coincidence timing resolution at 200 keV is as large as 1.2 ns.
△ Less
Submitted 3 October, 2013;
originally announced October 2013.