-
Development of large-volume $^{130}$TeO$_2$ bolometers for the CROSS $2β$ decay search experiment
Authors:
F. T. Avignone III,
A. S. Barabash,
V. Berest,
L. Bergé,
J. M. Calvo-Mozota,
P. Carniti,
M. Chapellier,
I. Dafinei,
F. A. Danevich,
L. Dumoulin,
F. Ferella,
F. Ferri,
A. Gallas,
A. Giuliani,
C. Gotti,
P. Gras,
A. Ianni,
L. Imbert,
H. Khalife,
V. V. Kobychev,
S. I. Konovalov,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
C. A. Marrache-Kikuchi
, et al. (14 additional authors not shown)
Abstract:
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a fe…
▽ More
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to ~91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a few ppm of the total concentration of residual elements (the main impurity is Fe). The purest part of the ingot (the first ~200 mm, ~80% of the total length of the cylindrical part of the ingot) was determined by scanning segregation profiles of impurities (both on the surface and in center of the ingot) and used for the $^{130}$TeO$_2$ powder production with no evidence of re-contamination. The crystal growth was verified with precursors produced from powder with natural Te isotopic composition, and two small-size (20x20x10 mm) samples were tested at a sea-level laboratory showing high bolometric and spectrometric performance together with acceptable $^{210}$Po content (below 10 mBq/kg). This growth method was then applied for the production of six large cubic $^{130}$TeO$_2$ crystals for the CROSS experiment and 4 of them were taken randomly to be characterized at the Canfranc underground laboratory, in the CROSS-dedicated low-background cryogenic facility. Two $^{130}$TeO$_2$ samples were coated with a thin metal film in form of Al layer (on 4 sides) or AlPd grid (on a single side) to investigate the possibility to tag surface events by pulse-shape discrimination. Similarly to the small natural precursors, large-volume $^{130}$TeO$_2$ bolometers show high performance and even better internal purity ($^{210}$Po activity ~ 1 mBq/kg, while activities of $^{228}$Th and $^{226}$Ra are below 0.01 mBq/kg), satisfying requirements for the CROSS and, potentially, next-generation experiments.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Measurement of the 2$νββ$ Decay Half-Life of Se-82 with the Global CUPID-0 Background Model
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini,
F. Ferroni,
L. Gironi
, et al. (27 additional authors not shown)
Abstract:
We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82~kg$\times$yr of $^{82}$Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double $β$-decay of $^{82}$Se and $^{100}$Mo is expected, making more solid the foundations…
▽ More
We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82~kg$\times$yr of $^{82}$Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double $β$-decay of $^{82}$Se and $^{100}$Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double $β$-decay half-life of $^{82}$Se with unprecedented accuracy: $T_{1/2}^{2ν} = [8.69 \pm 0.05 \textrm{(stat.)}~^{+0.09}_{-0.06} \textrm{(syst.)}] \times 10^{19}~\textrm{yr}$.
△ Less
Submitted 28 November, 2023; v1 submitted 26 June, 2023;
originally announced June 2023.
-
Deep-underground search for the decay of 180m-Ta with an ultra-low-background HPGe detector
Authors:
R. Cerroni,
S. Dell'Oro,
A. Formicola,
S. Ghislandi,
L. Ioannucci,
M. Laubenstein,
B. Lehnert,
S. S. Nagorny,
S. Nisi,
L. Pagnanini
Abstract:
$^{180m}$Ta is the longest-lived metastable state presently known. Its decay has not been observed yet. In this work, we report a new result on the decay of \mTa obtained with a $2015.12$-g tantalum sample measured for $527.7…
▽ More
$^{180m}$Ta is the longest-lived metastable state presently known. Its decay has not been observed yet. In this work, we report a new result on the decay of \mTa obtained with a $2015.12$-g tantalum sample measured for $527.7$ d with an ultra-low background HPGe detector in the STELLA laboratory of the Laboratori Nazionali del Gran Sasso (LNGS), in Italy. Before the measurement, the sample has been stored deep-underground for ten years, resulting in subdominant background contributions from cosmogenically activated $^{182}$Ta. We observe no signal in the regions of interest and set half-life limits on the process for the two channels EC and $β^-$: $T_{1/2,~\mathrm{EC}} > 1.6 \times 10^{18}$ yr and $T_{1/2,~β^-} > 1.1\times 10^{18}$ yr ($90$\% C.\,I.), respectively. We also set the limit on the $γ$ de-excitation / IC channel: $T_{1/2,~\mathrm{IC}} > 4.1 \times 10^{15}$ yr ($90$\% C.\,I.). These are, as of now, the most stringent bounds on the decay of $^{180m}$Ta worldwide. Finally, we test the hypothetical scenarios of de-excitation of $^{180m}$Ta by cosmological Dark Matter and constrain new parameter space for strongly-interacting dark-matter particle with mass up to $10^5$ GeV.
△ Less
Submitted 24 October, 2023; v1 submitted 26 May, 2023;
originally announced May 2023.
-
ZnO-based scintillating bolometers: New prospects to study double beta decay of $^{64}$Zn
Authors:
A. Armatol,
B. Broerman,
L. Dumoulin,
A. Giuliani,
H. Khalife,
M. Laubenstein,
P. Loaiza,
P. de Marcillac,
S. Marnieros,
S. S. Nagorny,
S. Nisi,
C. Nones,
E. Olivieri,
L. Pagnanini,
S. Pirro,
D. V. Poda,
J. -A. Scarpaci,
A. S. Zolotarova
Abstract:
The first detailed study on the performance of a ZnO-based cryogenic scintillating bolometer as a detector to search for rare processes in zinc isotopes was performed. A 7.2 g ZnO low-temperature detector, containing more than 80\% of zinc in its mass, exhibits good energy resolution of baseline noise 1.0--2.7 keV FWHM at various working temperatures resulting in a low-energy threshold for the exp…
▽ More
The first detailed study on the performance of a ZnO-based cryogenic scintillating bolometer as a detector to search for rare processes in zinc isotopes was performed. A 7.2 g ZnO low-temperature detector, containing more than 80\% of zinc in its mass, exhibits good energy resolution of baseline noise 1.0--2.7 keV FWHM at various working temperatures resulting in a low-energy threshold for the experiment, 2.0--6.0 keV. The light yield for $β$/$γ$ events was measured as 1.5(3) keV/MeV, while it varies for $α$ particles in the range of 0.2--3.0 keV/MeV. The detector demonstrate an effective identification of the $β$/$γ$ events from $α$ events using time-properties of only heat signals. %(namely, Rise time parameter). The radiopurity of the ZnO crystal was evaluated using the Inductively Coupled Plasma Mass Spectrometry, an ultra-low-background High Purity Ge $γ$-spectrometer, and bolometric measurements. Only limits were set at the level of $\mathcal{O}$(1--100) mBq/kg on activities of \Nuc{K}{40}, \Nuc{Cs}{137} and daughter nuclides from the U/Th natural decay chains. The total internal $α$-activity was calculated to be 22(2) mBq/kg, with a major contribution caused by 6(1) mBq/kg of \Nuc{Th}{232} and 12(2) mBq/kg of \Nuc{U}{234}. Limits on double beta decay (DBD) processes in \Nuc{Zn}{64} and \Nuc{Zn}{70} isotopes were set on the level of $\mathcal{O}(10^{17}$--$10^{18})$ yr for various decay modes profiting from 271 h of acquired background data in the above-ground lab. This study shows a good potential for ZnO-based scintillating bolometers to search for DBD processes of Zn isotopes, especially in \Nuc{Zn}{64}, with the most prominent spectral features at $\sim$10--20 keV, like the two neutrino double electron capture. A 10 kg-scale experiment can reach the experimental sensitivity at the level of $\mathcal{O}(10^{24})$ yr.
△ Less
Submitted 11 April, 2023;
originally announced April 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Search for resonant neutrinoless double electron capture in Gd-152 and other rare decays in Gd isotopes
Authors:
M. Laubenstein,
B. Lehnert,
S. S. Nagorny,
S. Nisi
Abstract:
A search for rare decays of gadolinium isotopes was performed with an ultra-low background high-purity germanium detector at Gran Sasso Underground Laboratory (Italy). A 198 g Gd$_2$O$_3$ powder sample was measured for 63.8 d with a total Gd exposure of 12.6 kg$\times$d. $^{152}$Gd is the most promising isotope for resonant neutrinoless double electron capture which could significantly enhance the…
▽ More
A search for rare decays of gadolinium isotopes was performed with an ultra-low background high-purity germanium detector at Gran Sasso Underground Laboratory (Italy). A 198 g Gd$_2$O$_3$ powder sample was measured for 63.8 d with a total Gd exposure of 12.6 kg$\times$d. $^{152}$Gd is the most promising isotope for resonant neutrinoless double electron capture which could significantly enhance the decay rate over other neutrinoless double beta decay processes. The half-life for this decay was constrained to $>4.2\times10^{12}$ yr (90\% credibility). This limit is still orders of magnitude away from theoretical predictions but it is the first established limit on the transition paving the way for future experiments. In addition, other rare alpha and double beta decay modes were investigated in $^{152}$Gd, $^{154}$Gd, and $^{160}$Gd with half-life limits in the range of $10^{17-20}$ yr.
△ Less
Submitted 1 March, 2023; v1 submitted 13 February, 2023;
originally announced February 2023.
-
Updated and novel limits on double beta decay and dark matter-induced processes in platinum
Authors:
B. Broerman,
M. Laubenstein,
S. Nagorny,
S. Nisi,
N. Song,
A. C. Vincent
Abstract:
A 510 day long-term measurement of a 45.3 g platinum foil acting as the sample and high voltage contact in an ultra-low-background high purity germanium detector was performed at Laboratori Nazionali del Gran Sasso (Italy). The data was used for a detailed study of double beta decay modes in natural platinum isotopes. Limits are set in the range $\mathcal{O}(10^{14} - 10^{19})$ yr (90% C.L.) for s…
▽ More
A 510 day long-term measurement of a 45.3 g platinum foil acting as the sample and high voltage contact in an ultra-low-background high purity germanium detector was performed at Laboratori Nazionali del Gran Sasso (Italy). The data was used for a detailed study of double beta decay modes in natural platinum isotopes. Limits are set in the range $\mathcal{O}(10^{14} - 10^{19})$ yr (90% C.L.) for several double beta decay transitions to excited states confirming, and partially extending existing limits. The highest sensitivity of the measurement, greater than $10^{19}$ yr, was achieved for the two neutrino and neutrinoless double beta decay modes of the isotope $^{198}$Pt. Additionally, novel limits for inelastic dark matter scattering on $^{195}$Pt are placed up to mass splittings of approximately 500 keV. We analyze several techniques to extend the sensitivity and propose a few approaches for future medium-scale experiments with platinum-group elements.
△ Less
Submitted 9 May, 2023; v1 submitted 22 September, 2022;
originally announced September 2022.
-
Search for Majoron-like particles with CUPID-0
Authors:
CUPID-0 Collaboration,
:,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini
, et al. (29 additional authors not shown)
Abstract:
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the…
▽ More
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
Final Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
F. De Dominics,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (23 additional authors not shown)
Abstract:
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last…
▽ More
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last phase (June 2019 - February 2020). In this letter, we describe the search for neutrinoless double beta decay of $^{82}$Se with a total exposure (phase I + II) of 8.82 kg$\times$yr of isotope. We set a limit on the half-life of $^{82}$Se to the ground state of $^{82}$Kr of T$^{0ν}_{1/2}$($^{82}$Se)$>$ 4.6$\times \mathrm{10}^{24}$ yr (90\% credible interval), corresponding to an effective Majorana neutrino mass m$_{ββ} <$ (263 -- 545) meV. We also set the most stringent lower limits on the neutrinoless decays of $^{82}$Se to the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr, finding 1.8$\times$10$^{23}$ yr, 3.0$\times$10$^{23}$ yr, 3.2$\times$10$^{23}$ yr (90$\%$ credible interval) respectively.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
Toward CUPID-1T
Authors:
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani
, et al. (150 additional authors not shown)
Abstract:
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years…
▽ More
Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$.
We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.
△ Less
Submitted 8 April, 2022; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
High sensitivity characterization of an ultra-high purity NaI(Tl) crystal scintillator with the SABRE proof-of-principle detector
Authors:
F. Calaprice,
S. Copello,
I. Dafinei,
D. D'Angelo,
G. D'Imperio,
G. Di Carlo,
M. Diemoz,
A. Di Giacinto,
A. Di Ludovico,
A. Ianni,
M. Iannone,
F. Marchegiani,
A. Mariani,
S. Milana,
S. Nisi,
F. Nuti,
D. Orlandi,
V. Pettinacci,
L. Pietrofaccia,
S. Rahatlou,
M. Souza,
B. Suerfu,
C. Tomei,
C. Vignoli,
M. Wada
, et al. (1 additional authors not shown)
Abstract:
We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the direct counting of radioactive $^{40}$K, is found to be $2.2\pm1.5$ ppb, lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1-6 keV energy…
▽ More
We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the direct counting of radioactive $^{40}$K, is found to be $2.2\pm1.5$ ppb, lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1-6 keV energy region-of-interest (ROI) is $1.20\pm0.05$ counts/day/kg/keV, which is a breakthrough since the DAMA/LIBRA experiment. Our background model indicates that the rate is dominated by $^{210}$Pb and that about half of this contamination is located in the PTFE reflector. We discuss ongoing developments of the crystal manufacture aimed at the further reduction of the background, including data from purification by zone refining. A projected background rate lower than $\sim$0.2 counts/day/kg/keV in the ROI is within reach. These results represent a benchmark for the development of next-generation NaI(Tl) detector arrays for the direct detection of dark matter particles.
△ Less
Submitted 19 May, 2021;
originally announced May 2021.
-
Background identification in cryogenic calorimeters through $α-α$ delayed coincidences
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez
, et al. (20 additional authors not shown)
Abstract:
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to inv…
▽ More
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $α$ decay position.
△ Less
Submitted 13 August, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Measurement of $^{216}$Po half-life with the CUPID-0 experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
V. Caracciolo,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti
, et al. (22 additional authors not shown)
Abstract:
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited ex…
▽ More
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $\pm$ 2.8) ms.
△ Less
Submitted 12 May, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Results on $^{82}$Se $2νββ$ with CUPID-0 Phase I
Authors:
L Pagnanini,
O Azzolini,
J W Beeman,
F Bellini,
M Beretta,
M Biassoni,
C Brofferio,
C Bucci,
S Capelli,
L Cardani,
P Carniti,
N Casali,
D Chiesa,
M Clemenza,
O Cremonesi,
A Cruciani,
I Dafinei,
S Di Domizio,
F Ferroni,
L Gironi,
A Giuliani,
P Gorla,
C Gotti,
G Keppel,
M Martinez
, et al. (19 additional authors not shown)
Abstract:
The nucleus is an extraordinarily complex object where fundamental forces are at work. The solution of this many-body problem has challenged physicists for decades: several models with complementary virtues and flaws have been adopted, none of which has a universal predictive capability. Double beta decay is a second-order weak nuclear decay whose precise measurement might steer fundamental improv…
▽ More
The nucleus is an extraordinarily complex object where fundamental forces are at work. The solution of this many-body problem has challenged physicists for decades: several models with complementary virtues and flaws have been adopted, none of which has a universal predictive capability. Double beta decay is a second-order weak nuclear decay whose precise measurement might steer fundamental improvements in nuclear theory. Its knowledge paves the way to a much better understanding of many-body nuclear dynamics and clarifies, in particular, the role of multiparticle states. This is a useful input to a complete understanding of the dynamics of neutrino-less double beta decay, the chief physical process whose discovery may shed light to the matter-antimatter asymmetry of the universe and unveil the true nature of neutrinos. Here, we report the study of $2νββ$-decay in $^{82}$Se with the CUPID-0 detector, an array of ZnSe crystals maintained at a temperature close to 'absolute zero' in an ultralow background environment. Thanks to the unprecedented accuracy in the measurement of the two electrons spectrum, we prove that the decay is dominated by a single intermediate state. We obtain also the most precise value for the $^{82}$Se $2νββ$-decay half-life of $T^{2ν}_{1/2} = [8.6^{+0.2}_{-0.1}] \times 10^{19}$ yr.
△ Less
Submitted 23 December, 2020;
originally announced December 2020.
-
Double beta decay results from the CUPID-0 experiment
Authors:
D. Chiesa,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
E. Celi,
P. Carniti,
N. Casali,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel
, et al. (21 additional authors not shown)
Abstract:
A convincing observation of neutrino-less double beta decay (0$ν$DBD) relies on the possibility of operating high energy-resolution detectors in background-free conditions. Scintillating cryogenic calorimeters are one of the most promising tools to fulfill the requirements for a next-generation experiment. Several steps have been taken to demonstrate the maturity of this technique, starting from t…
▽ More
A convincing observation of neutrino-less double beta decay (0$ν$DBD) relies on the possibility of operating high energy-resolution detectors in background-free conditions. Scintillating cryogenic calorimeters are one of the most promising tools to fulfill the requirements for a next-generation experiment. Several steps have been taken to demonstrate the maturity of this technique, starting from the successful experience of CUPID-0. The CUPID-0 experiment demonstrated the complete rejection of the dominant alpha background measuring the lowest counting rate in the region of interest for this technique. Furthermore, the most stringent limit on the $^{82}$Se 0$ν$DBD was established running 26 ZnSe crystals during two years of continuous detector operation. In this contribution we present the final results of CUPID-0 Phase I including a detailed model of the background, the measurement of the $^{82}$Se 2$ν$DBD half-life and the evidence that this nuclear transition is single state dominated.
△ Less
Submitted 1 December, 2020;
originally announced December 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Search for $α$ decay of naturally occurring Hf-nuclides using a Cs$_2$HfCl$_6$ scintillator
Authors:
V. Caracciolo,
S. Nagorny,
P. Belli,
R. Bernabei,
F. Cappella,
R. Cerulli,
A. Incicchitti,
M. Laubenstein,
V. Merlo,
S. Nisi,
P. Wang
Abstract:
Residual radioactive contaminants of a caesium hafnium chloride (Cs$_2$HfCl$_6$) crystal scintillator have been measured in a low background setup at the Gran Sasso National Laboratory of the INFN, Italy. The total alpha activity of the detector is at the level of 7.8(3) mBq/kg. The results of direct studies of the $α$ decay of naturally occurring Hf isotopes that have been performed using the "so…
▽ More
Residual radioactive contaminants of a caesium hafnium chloride (Cs$_2$HfCl$_6$) crystal scintillator have been measured in a low background setup at the Gran Sasso National Laboratory of the INFN, Italy. The total alpha activity of the detector is at the level of 7.8(3) mBq/kg. The results of direct studies of the $α$ decay of naturally occurring Hf isotopes that have been performed using the "source=detector" approach are presented. In 2848 h of data taking, the $α$ decay of $^{174}$Hf was observed with T$_{1/2} = (7.0\pm1.2)\times10^{16} $ y.
△ Less
Submitted 23 May, 2020; v1 submitted 4 May, 2020;
originally announced May 2020.
-
Search for Neutrino-less Double Beta Decay of $^{64}$Zn and $^{70}$Zn with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
E. Celi,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremomesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel
, et al. (21 additional authors not shown)
Abstract:
CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the underground Laboratori Nazionali del Gran Sasso. In this work, we analyzed a ZnSe exposure of 11.34 kg$\times$yr to search for the neutrino-less double beta decay of…
▽ More
CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the underground Laboratori Nazionali del Gran Sasso. In this work, we analyzed a ZnSe exposure of 11.34 kg$\times$yr to search for the neutrino-less double beta decay of $^{70}$Zn and for the neutrino-less positron-emitting electron capture of $^{64}$Zn. We found no evidence for these decays and set 90$\%$ credible interval limits of ${\rm T}_{1/2}^{0νββ}(^{70}{\rm Zn}) > 1.6 \times 10^{21}$ yr and ${\rm T}_{1/2}^{0νEC β+}(^{64}{\rm Zn}) > 1.2 \times 10^{22}$ yr, surpassing by almost two orders of magnitude the previous experimental results
△ Less
Submitted 15 September, 2020; v1 submitted 24 March, 2020;
originally announced March 2020.
-
Na-based crystal scintillators for next-generation rare event searches
Authors:
S. Nagorny,
C. Rusconi,
S. Sorbino,
J. W. Beeman,
F. Bellini,
L. Cardani,
V. D. Grigorieva,
L. Pagnanini,
S. Nisi,
S. Pirro,
K. Schäffner,
V. N. Shlegel
Abstract:
The growing interest in clarifying the controversial situation in the Dark Matter sector has driven the experimental efforts towards new ways to investigate the long-standing DAMA/LIBRA result. Among them, low-temperature calorimeters based on Na-containing scintillating crystals offer the possibility to clarify the nature of the measured signal via particle identification. Here we report the firs…
▽ More
The growing interest in clarifying the controversial situation in the Dark Matter sector has driven the experimental efforts towards new ways to investigate the long-standing DAMA/LIBRA result. Among them, low-temperature calorimeters based on Na-containing scintillating crystals offer the possibility to clarify the nature of the measured signal via particle identification. Here we report the first measurement of Na-containing crystals, based on material different from NaI, i.e. Na$_2$Mo$_2$O$_7$ and Na$_2$W$_2$O$_7$, pointing out their excellent performance in term of energy resolution, light yield, and particle identification.
△ Less
Submitted 26 November, 2019;
originally announced November 2019.
-
First search for Lorentz violation in double beta decay with scintillating calorimeters
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez,
S. Nagorny
, et al. (20 additional authors not shown)
Abstract:
We present the search for Lorentz violation in the double beta decay of ^{82}Se~with CUPID-0, using an exposure of 9.95 kg x y. We found no evidence for the searched signal and set a limit on the isotropic components of the Lorentz violating coefficient of $\mathring{a}_{\text{of}}^{(3)} < 4.1\cdot10^{-6}$ GeV (90\% Credible Interval). This results is obtained with a Bayesian analysis of the exper…
▽ More
We present the search for Lorentz violation in the double beta decay of ^{82}Se~with CUPID-0, using an exposure of 9.95 kg x y. We found no evidence for the searched signal and set a limit on the isotropic components of the Lorentz violating coefficient of $\mathring{a}_{\text{of}}^{(3)} < 4.1\cdot10^{-6}$ GeV (90\% Credible Interval). This results is obtained with a Bayesian analysis of the experimental data and fully includes the systematic uncertainties of the model. This is the first limit on $\mathring{a}_{\text{of}}^{(3)}$ obtained with a scintillating bolometer, showing the potentiality of this technique.
△ Less
Submitted 6 November, 2019;
originally announced November 2019.
-
First direct search for $2ε$ and $εβ^+$ decay of $^{144}$Sm and $2β^-$ decay of $^{154}$Sm
Authors:
P. Belli,
R. Bernabei,
R. S. Boiko,
F. Cappella,
V. Caracciolo,
R. Cerulli,
F. A. Danevich,
A. Di Marco,
A. Incicchitti,
B. N. Kropivyansky,
M. Laubenstein,
S. Nisi,
D. V. Poda,
O. G. Polischuk,
V. I. Tretyak
Abstract:
The first direct search for the double electron capture ($2ε$) and the electron capture with positron emission ($εβ^+$) in $^{144}$Sm to the ground state and to the excited levels of $^{144}$Nd was realized by measuring - over 1899 h - a 342 g sample of highly purified samarium oxide (Sm$_2$O$_3$) with the ultra-low background HP-Ge $γ$ spectrometer GeCris (465 cm$^3$) at the STELLA facility of th…
▽ More
The first direct search for the double electron capture ($2ε$) and the electron capture with positron emission ($εβ^+$) in $^{144}$Sm to the ground state and to the excited levels of $^{144}$Nd was realized by measuring - over 1899 h - a 342 g sample of highly purified samarium oxide (Sm$_2$O$_3$) with the ultra-low background HP-Ge $γ$ spectrometer GeCris (465 cm$^3$) at the STELLA facility of the Gran Sasso National Laboratory (LNGS). No effect was observed and half-life limits were estimated at the level of $T_{1/2} \sim (0.1-1.3) \times 10^{20}$ yr (90% C.L.). Moreover, for the first time half-life limits of the double beta ($2β^-$) decay of $^{154}$Sm to several excited levels of $^{154}$Gd have been set; they are at the level of $T_{1/2} \sim (0.06-8) \times 10^{20}$ yr (90% C.L.).
△ Less
Submitted 5 October, 2019;
originally announced October 2019.
-
Evidence of Single State Dominance in the Two-Neutrino Double-$β$ Decay of Se-82 with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
J. Kotila,
M. Martinez
, et al. (20 additional authors not shown)
Abstract:
We report on the measurement of the two-neutrino double-$β$ decay of $^{82}$Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0~experiment. With an exposure of 9.95 kg$\times$yr of Zn$^{82}$Se, we determine the two-neutrino double-$β$ decay half-life of $^{82}$Se with an unprecedented precision level,…
▽ More
We report on the measurement of the two-neutrino double-$β$ decay of $^{82}$Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0~experiment. With an exposure of 9.95 kg$\times$yr of Zn$^{82}$Se, we determine the two-neutrino double-$β$ decay half-life of $^{82}$Se with an unprecedented precision level, $T_{1/2}^{2ν} = [8.60 \pm 0.03 \textrm{(stat.)}~^{+0.17}_{-0.10} \textrm{(syst.)}] \times 10^{19}~\textrm{yr}$. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5 $σ$.
△ Less
Submitted 20 November, 2019; v1 submitted 8 September, 2019;
originally announced September 2019.
-
First search for 2$\varepsilon$ and $\varepsilonβ^+$ processes in $^{168}$Yb
Authors:
P. Belli,
R. Bernabei,
R. S. Boiko,
F. Cappella,
V. Caracciolo,
R. Cerulli,
F. A. Danevich,
M. L. di Vacri,
A. Incicchitti,
B. N. Kropivyansky,
M. Laubenstein,
S. Nisi,
D. V. Poda,
O. G. Polischuk,
V. I. Tretyak
Abstract:
The double-electron capture and the electron capture with positron emission in $^{168}$Yb have been investigated for the first time at the STELLA facility of the Gran Sasso underground laboratory (Italy) measuring 371 g of highly purified ytterbium oxide placed on the end-cap of a 465 cm$^3$ ultra-low-background high purity Germanium detector (HPGe). No gamma associated to double beta processes in…
▽ More
The double-electron capture and the electron capture with positron emission in $^{168}$Yb have been investigated for the first time at the STELLA facility of the Gran Sasso underground laboratory (Italy) measuring 371 g of highly purified ytterbium oxide placed on the end-cap of a 465 cm$^3$ ultra-low-background high purity Germanium detector (HPGe). No gamma associated to double beta processes in $^{168}$Yb have been observed after 2074 h of data taking. This has allowed setting the half-life limits on the level of $\lim T_{1/2}\sim$ $10^{14}-10^{18}$ yr at 90\% C.L. Particularly, a lower half-life limit on a possible resonant neutrinoless double-electron capture in $^{168}$Yb to the $(2)^-$ 1403.7 keV excited state of $^{168}$Er is set as $T_{1/2}\geq1.9\times 10^{18}$ yr at 90\% C.L. Half-life limits $T_{1/2}^{2ν(0ν)}\geq 4.5(4.3)\times10^{16}$ yr were set on the $2ν(0ν)2β^-$ decay of $^{176}$Yb to the $2^+$ 84.3 keV first excited level of $^{176}$Hf.
△ Less
Submitted 26 June, 2019;
originally announced June 2019.
-
Final result of CUPID-0 phase-I in the search for the $^{82}$Se Neutrinoless Double Beta Decay
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez,
S. Nagorny
, et al. (19 additional authors not shown)
Abstract:
CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0$ν$DBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a $^{82}$Se exposure of 5.29 kg$\times$yr. In this paper w…
▽ More
CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0$ν$DBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a $^{82}$Se exposure of 5.29 kg$\times$yr. In this paper we present the phase-I results in the search for 0$ν$DBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: $(3.5^{+1.0}_{-0.9})\times10^{-3}$ counts/(keV kg yr). Monitoring 3.88$\times$10$^{25}$ $^{82}$Se nuclei$\times$yr we reach a 90% credible interval median sensitivity of $\rm{T}^{0ν}_{1/2}>5.0\times10^{24} \rm{yr}$ and set the most stringent limit on the half-life of $^{82}$Se 0$ν$DBD : $\rm{T}^{0ν}_{1/2}>3.5\times10^{24} \rm{yr}$ (90% credible interval), corresponding to m$_{ββ} <$ (311-638) meV depending on the nuclear matrix element calculations.
△ Less
Submitted 12 June, 2019;
originally announced June 2019.
-
Background Model of the CUPID-0 Experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez,
S. Nagorny
, et al. (19 additional authors not shown)
Abstract:
CUPID-0 is the first large mass array of enriched Zn$^{82}$Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of 9.95 kg yr. Thanks to the excellent rejection of $α$ particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of…
▽ More
CUPID-0 is the first large mass array of enriched Zn$^{82}$Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of 9.95 kg yr. Thanks to the excellent rejection of $α$ particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of $^{82}$Se neutrinoless double beta decay. In this work we develop a model to reconstruct the CUPID-0 background over the whole energy range of experimental data. We identify the background sources exploiting their distinctive signatures and we assess their extremely low contribution (down to $\sim10^{-4}$ counts/(keV kg yr)) in the region of interest for $^{82}$Se neutrinoless double beta decay search. This result represents a crucial step towards the comprehension of the background in experiments based on scintillating calorimeters and in next generation projects such as CUPID.
△ Less
Submitted 17 July, 2019; v1 submitted 23 April, 2019;
originally announced April 2019.
-
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
Authors:
C. Alduino,
F. Alessandria,
M. Balata,
D. Biare,
M. Biassoni,
C. Bucci,
A. Caminata,
L. Canonica,
L. Cappelli,
G. Ceruti,
A. Chiarini,
N. Chott,
M. Clemenza,
S. Copello,
A. Corsi,
O. Cremonesi,
A. D'Addabbo,
S. Dell'Oro,
L. Di Paolo,
M. L. Di Vacri,
A. Drobizhev,
M. Faverzani,
E. Ferri,
M. A. Franceschi,
R. Gaigher
, et al. (31 additional authors not shown)
Abstract:
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, requ…
▽ More
The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.
△ Less
Submitted 12 July, 2019; v1 submitted 8 April, 2019;
originally announced April 2019.
-
A new investigation of half-lives for the decay modes of $^{50}$V
Authors:
M. Laubenstein,
B. Lehnert,
S. S. Nagorny,
S. Nisi,
K. Zuber
Abstract:
A new search for the decay modes of the 4-fold forbidden non-unique decay of $^{50}$V has been performed at the Gran Sasso Underground Laboratory (LNGS). In total an exposure of 197 kg $\times$ d has been accumulated. The half-life for the electron capture into the first excited state of $^{50}$Ti has been measured with the highest precision to date as $2.67_{-0.18}^{+0.16} \times 10^{17}$ yr (68%…
▽ More
A new search for the decay modes of the 4-fold forbidden non-unique decay of $^{50}$V has been performed at the Gran Sasso Underground Laboratory (LNGS). In total an exposure of 197 kg $\times$ d has been accumulated. The half-life for the electron capture into the first excited state of $^{50}$Ti has been measured with the highest precision to date as $2.67_{-0.18}^{+0.16} \times 10^{17}$ yr (68% C.I.) in which systematics uncertainties dominate. The search for the $β$-decay into the first excited state of $^{50}$Cr resulted in a lower limit of ${1.9} \times 10^{19}$ yr (90% C.I.), which is an improvement of almost one order of magnitude compared to existing results. The sensitivity of the new measurement is now in the region of theoretical predictions.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
First search for $2\varepsilon$ and $\varepsilonβ^+$ decay of $^{162}$Er and new limit on $2β^{-}$ decay of $^{170}$Er to the first excited level of $^{170}$Yb
Authors:
P. Belli,
R. Bernabei,
R. S. Boiko,
F. Cappella,
V. Caracciolo,
R. Cerulli,
F. A. Danevich,
A. Incicchitti,
B. N. Kropivyansky,
M. Laubenstein,
S. Nisi,
D. V. Poda,
O. G. Polischuk,
V. I. Tretyak
Abstract:
The first search for double electron capture ($2\varepsilon$) and electron capture with positron emission ($\varepsilonβ^+$) of $^{162}$Er to the ground state and to several excited levels of $^{162}$Dy was realized with 326 g of highly purified erbium oxide. The sample was measured over 1934 h by the ultra-low background HP Ge $γ$ spectrometer GeCris (465 cm$^3$) at the Gran Sasso underground lab…
▽ More
The first search for double electron capture ($2\varepsilon$) and electron capture with positron emission ($\varepsilonβ^+$) of $^{162}$Er to the ground state and to several excited levels of $^{162}$Dy was realized with 326 g of highly purified erbium oxide. The sample was measured over 1934 h by the ultra-low background HP Ge $γ$ spectrometer GeCris (465 cm$^3$) at the Gran Sasso underground laboratory. No effect was observed, the half-life limits were estimated at the level of $\lim T_{1/2}\sim 10^{15}-10^{18}$ yr. A possible resonant $0νKL_1$ capture in $^{162}$Er to the $2^+$ 1782.7 keV excited state of $^{162}$Dy is restricted as $T_{1/2}\geq5.0\times 10^{17}$ yr at 90% C.L. A new improved half-life limit $T_{1/2}\geq4.1\times 10^{17}$ yr was set on the $2β^-$ decay of $^{170}$Er to the $2^+$ 84.3 keV first excited state of $^{170}$Yb.
△ Less
Submitted 6 August, 2018;
originally announced August 2018.
-
Status of the HOLMES Experiment to Directly Measure the Neutrino Mass
Authors:
A. Nucciotti,
B. Alpert,
M. Balata,
D. BeckerD. Bennett,
A. Bevilacqua,
M. Biasotti,
V. Ceriale,
G. Ceruti,
D. Corsini,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
G. Gallucci,
J. Gard,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Köster,
M. Lusignoli,
J. Mates,
S. Nisi
, et al. (13 additional authors not shown)
Abstract:
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass…
▽ More
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope $^{163}$Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed in 1982 by A. De Rujula and M. Lusignoli, but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low temperature microcalorimeters with implanted $^{163}$Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
Search of the neutrino-less double beta decay of $^{82}$Se into the excited states of $^{82}$Kr with CUPID-0
Authors:
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
E. Bossio,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (25 additional authors not shown)
Abstract:
The CUPID0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95$\%$ enriched in $^{82}$Se and 2 natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of $^{82}$Se into the 0$_1^+$, 2$_1^+$ and 2…
▽ More
The CUPID0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95$\%$ enriched in $^{82}$Se and 2 natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of $^{82}$Se into the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr with an exposure of 5.74 kg$\cdot$yr (2.24$\times$10$^{25}$ emitters$\cdot$yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{0_1^+}$)$<$8.55$\times$10$^{-24}$ yr$^{-1}$, $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{2_1^+}$)$<6.25 \times10^{-24}$ yr$^{-1}$, $Γ$($^{82}$Se $\rightarrow ^{82}$Kr$_{2_2^+}$)$<$8.25$\times$10$^{-24}$ yr$^{-1}$ (90$\%$ credible interval
△ Less
Submitted 18 October, 2018; v1 submitted 2 July, 2018;
originally announced July 2018.
-
Analysis of cryogenic calorimeters with light and heat read-out for double beta decay searches
Authors:
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
E. Bossio,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casalia,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (25 additional authors not shown)
Abstract:
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation lig…
▽ More
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn$^{82}$Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.
△ Less
Submitted 30 August, 2018; v1 submitted 7 June, 2018;
originally announced June 2018.
-
First Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
CUPID-0 collaboration,
:,
O. Azzolini,
M. T. Barrera,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
L. Canonica,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
L. Cassina,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani
, et al. (28 additional authors not shown)
Abstract:
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\…
▽ More
We report the result of the search for neutrinoless double beta decay of $^{82}$Se obtained with CUPID-0, the first large array of scintillating Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr $^{82}$Se exposure and we set the most stringent lower limit on the \onu $^{82}$Se half-life T$^{0ν}_{1/2}>$ 2.4$\times \mathrm{10}^{24}$ yr (90\% credible interval), which corresponds to an effective Majorana neutrino mass m$_{ββ} <$ (376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of \al\ particles and allows to suppress the background in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\times$10$^{-3}$\ckky, an unprecedented level for this technique.
△ Less
Submitted 5 June, 2018; v1 submitted 21 February, 2018;
originally announced February 2018.
-
Upgrade for Phase II of the GERDA Experiment
Authors:
M. Agostini,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
A. Domula,
E. Doroshkevich,
V. Egorov
, et al. (89 additional authors not shown)
Abstract:
The GERDA collaboration is performing a sensitive search for neutrinoless double beta decay of $^{76}$Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the GERDA experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieve…
▽ More
The GERDA collaboration is performing a sensitive search for neutrinoless double beta decay of $^{76}$Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the GERDA experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieved. GERDA is thus the first experiment that will remain background-free up to its design exposure (100 kg yr). It will reach thereby a half-life sensitivity of more than 10$^{26}$ yr within 3 years of data collection. This paper describes in detail the modifications and improvements of the experimental setup for Phase II and discusses the performance of individual detector components.
△ Less
Submitted 4 November, 2017;
originally announced November 2017.
-
Production of 82Se enriched Zinc Selenide (ZnSe) crystals for the study of neutrinoless double beta decay
Authors:
I. Dafinei,
S. Nagorny,
S. Pirro,
L. Cardani,
M. Clemenza,
F. Ferroni,
M. Laubenstein,
S. Nisi,
L. Pattavina,
K. Schaeffner,
M. L. di Vacri,
A. Boyarintsev,
I. Breslavskii,
S. Galkin,
A. Lalayants,
I. Rybalka,
V. Zvereva,
M. Enculescu
Abstract:
High purity Zinc Selenide (ZnSe) crystals are produced starting from elemental Zn and Se to be used for the search of the neutrinoless double beta decay (0νDBD) of 82Se. In order to increase the number of emitting nuclides, enriched 82Se is used. Dedicated production lines for the synthesis and conditioning of the Zn82Se powder in order to make it suitable for crystal growth were assembled complia…
▽ More
High purity Zinc Selenide (ZnSe) crystals are produced starting from elemental Zn and Se to be used for the search of the neutrinoless double beta decay (0νDBD) of 82Se. In order to increase the number of emitting nuclides, enriched 82Se is used. Dedicated production lines for the synthesis and conditioning of the Zn82Se powder in order to make it suitable for crystal growth were assembled compliant with radio-purity constraints specific to rare event physics experiments. Besides routine check of impurities concentration, high sensitivity measurements are made for radio-isotope concentrations in raw materials, reactants, consumables, ancillaries and intermediary products used for ZnSe crystals production. Indications are given on the crystals perfection and how it is achieved. Since very expensive isotopically enriched material (82Se) is used, a special attention is given for acquiring the maximum yield in the mass balance of all production stages. Production and certification protocols are presented and resulting ready-to-use Zn82Se crystals are described.
△ Less
Submitted 20 February, 2017;
originally announced February 2017.
-
Enriched TeO$_2$ bolometers with active particle discrimination: towards the CUPID experiment
Authors:
D. R. Artusa,
F. T. Avignone III,
J. W. Beeman,
I. Dafinei,
L. Dumoulin,
Z. Ge,
A. Giuliani,
C. Gotti,
P. de Marcillac,
S. Marnieros,
S. Nagorny,
S. Nisi,
C. Nones,
E. B. Norman,
V. Novati,
E. Olivieri,
D. Orlandi,
L. Pagnanini,
L. Pattavina,
G. Pessina,
S. Pirro,
D. V. Poda,
C. Rusconi,
K. Schäffner,
N. D. Scielzo
, et al. (1 additional authors not shown)
Abstract:
We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g each, show an energy resolution, evaluated at the 2615 keV $γ$-line of $^{208}$Tl, of 6.5 and 4.3 keV FWHM. The only observable internal radioactive contamination arises from…
▽ More
We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g each, show an energy resolution, evaluated at the 2615 keV $γ$-line of $^{208}$Tl, of 6.5 and 4.3 keV FWHM. The only observable internal radioactive contamination arises from $^{238}$U (15 and 8 $μ$Bq/kg, respectively). The internal activity of the most problematic nuclei for neutrinoless double beta decay, $^{226}$Ra and $^{228}$Th, are both evaluated as $<$3.1 $μ$Bq/kg for one crystal and $<$2.3 $μ$Bq/kg for the second. Thanks to the readout of the weak Cherenkov light emitted by $β/γ$ particles by means of Neganov-Luke bolometric light detectors we were able to perform an event-by-event identification of $β/γ$ events with a 95% acceptance level, while establishing a rejection factor of 98.21% and 99.99% for $α$ particles.
△ Less
Submitted 10 October, 2016;
originally announced October 2016.
-
CUORE-0 detector: design, construction and operation
Authors:
CUORE Collaboration,
C. Alduino,
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
C. Brofferio,
A. Buccheri,
C. Bucci,
C. Bulfon,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
M. Capodiferro,
L. Cappelli
, et al. (129 additional authors not shown)
Abstract:
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the C…
▽ More
The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
△ Less
Submitted 18 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
Low energy neutron background in deep underground laboratories
Authors:
Andreas Best,
Joachim Gorres,
Matthias Junker,
Karl-Ludwig Kratz,
Matthias Laubenstein,
Alexander Long,
Stefano Nisi,
Karl Smith,
Michael Wiescher
Abstract:
The natural neutron background influences the maximum achievable sensitivity in most deep underground nuclear, astroparticle and double-beta decay physics experiments. Reliable neutron flux numbers are an important ingredient in the design of the shielding of new large-scale experiments as well as in the analysis of experimental data.
Using a portable setup of He-3 counters we measured the therm…
▽ More
The natural neutron background influences the maximum achievable sensitivity in most deep underground nuclear, astroparticle and double-beta decay physics experiments. Reliable neutron flux numbers are an important ingredient in the design of the shielding of new large-scale experiments as well as in the analysis of experimental data.
Using a portable setup of He-3 counters we measured the thermal neutron flux at the Kimballton Underground Research Facility, the Soudan Underground Laboratory, on the 4100 ft and the 4850 ft levels of the Sanford Underground Research Facility, at the Waste Isolation Pilot Plant and at the Gran Sasso National Laboratory. Absolute neutron fluxes at these laboratories are presented.
△ Less
Submitted 2 September, 2015;
originally announced September 2015.
-
Double-beta decay investigation with highly pure enriched $^{82}$Se for the LUCIFER experiment
Authors:
J. W. Beeman,
F. Bellini,
P. Benetti,
L. Cardani,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
C. Gotti,
M. Laubenstein,
M. Maino,
S. Nagorny,
S. Nisi,
C. Nones,
F. Orio,
L. Pagnanini,
L. Pattavina,
G. Pessina,
G. Piperno,
S. Pirro,
E. Previtali
, et al. (4 additional authors not shown)
Abstract:
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of $^{82}$Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched $^{82}$Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is cruci…
▽ More
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of $^{82}$Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched $^{82}$Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3\% enriched $^{82}$Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of $^{232}$Th, $^{238}$U and $^{235}$U are respectively: $<$61 $μ$Bq/kg, $< $110 $μ$Bq/kg and $<$74 $μ$Bq/kg at 90\% C.L.. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the $^{82}$Se allowed us to establish the most stringent lower limits on the half-lives of double-beta decay of $^{82}$Se to 0$^+_1$, 2$^+_2$ and 2$^+_1$ excited states of $^{82}$Kr of 3.4$\cdot$10$^{22}$ y, 1.3$\cdot$10$^{22}$ y and 1.0$\cdot$10$^{22}$ y, respectively, with a 90\% C.L..
△ Less
Submitted 1 December, 2015; v1 submitted 7 August, 2015;
originally announced August 2015.
-
Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0
Authors:
K. Alfonso,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
A. Caminata,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Carbone,
L. Cardani,
N. Casali,
L. Cassina,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (93 additional authors not shown)
Abstract:
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The me…
▽ More
We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.
△ Less
Submitted 1 October, 2015; v1 submitted 9 April, 2015;
originally announced April 2015.
-
HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
Authors:
B. Alpert,
M. Balata,
D. Bennett,
M. Biasotti,
C. Boragno,
C. Brofferio,
V. Ceriale,
D. Corsini,
P. K. Day,
M. De Gerone,
R. Dressler,
M. Faverzani,
E. Ferri,
J. Fowler,
F. Gatti,
A. Giachero,
J. Hays-Wehle,
S. Heinitz,
G. Hilton,
U. Koester,
M. Lusignoli,
M. Maino,
J. Mates,
S. Nisi,
R. Nizzolo
, et al. (13 additional authors not shown)
Abstract:
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982…
▽ More
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
△ Less
Submitted 17 March, 2015; v1 submitted 16 December, 2014;
originally announced December 2014.
-
Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA
Authors:
M. Agostini,
M. Allardt,
E. Andreotti,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
N. Barros,
L. Baudis,
C. Bauer,
N. Becerici-Schmidt,
E. Bellotti,
S. Belogurov,
S. T. Belyaev,
G. Benato,
A. Bettini,
L. Bezrukov,
T. Bode,
D. Borowicz,
V. Brudanin,
R. Brugnera,
D. Budjas,
A. Caldwel,
C. Cattadori,
A. Chernogorov,
V. D'Andrea
, et al. (87 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used…
▽ More
The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay.
During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new $^{76}$Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in GERDA during Phase I.
The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the $^{76}$Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of GERDA Phase~II.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
S. Copello
, et al. (95 additional authors not shown)
Abstract:
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrino…
▽ More
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.
△ Less
Submitted 3 July, 2014;
originally announced July 2014.
-
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (94 additional authors not shown)
Abstract:
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simu…
▽ More
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.
△ Less
Submitted 17 April, 2014;
originally announced April 2014.
-
Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (96 additional authors not shown)
Abstract:
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detecto…
▽ More
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0νββ$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.
△ Less
Submitted 13 February, 2015; v1 submitted 25 February, 2014;
originally announced February 2014.
-
Initial performance of the CUORE-0 experiment
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (88 additional authors not shown)
Abstract:
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-domina…
▽ More
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
△ Less
Submitted 31 July, 2014; v1 submitted 4 February, 2014;
originally announced February 2014.
-
Discovery of the $^{151}$Eu $α$ decay
Authors:
N. Casali,
S. S. Nagorny,
F. Orio,
L. Pattavina,
J. W. Beeman,
F. Bellini,
L. Cardani,
I. Dafinei,
S. Di Domizio,
M. L. Di Vacri,
L. Gironi,
M. B. Kosmyna,
B. P. Nazarenko,
S. Nisi,
G. Pessina,
G. Piperno,
S. Pirro,
C. Rusconi,
A. N. Shekhovtsov,
C. Tomei,
M. Vignati
Abstract:
We report on the first compelling observation of $α$ decay of $^{151}$Eu to the ground state of $^{147}$Pm. The measurement was performed using a 6.15 g Li$_6$Eu(BO$_3$)$_3$ crystal operated as a scintillating bolometer. The Q-value and half-life measured are: Q = 1948.9$\pm 6.9(stat.) \pm 5.1(syst.)$ keV, and T$_{1/2}=\left( 4.62\pm0.95(stat.)\pm0.68(syst.)\right) \times 10^{18}$ y . The half-lif…
▽ More
We report on the first compelling observation of $α$ decay of $^{151}$Eu to the ground state of $^{147}$Pm. The measurement was performed using a 6.15 g Li$_6$Eu(BO$_3$)$_3$ crystal operated as a scintillating bolometer. The Q-value and half-life measured are: Q = 1948.9$\pm 6.9(stat.) \pm 5.1(syst.)$ keV, and T$_{1/2}=\left( 4.62\pm0.95(stat.)\pm0.68(syst.)\right) \times 10^{18}$ y . The half-life prediction of nuclear theory using the Coulomb and proximity potential model are in good agreement with this experimental result.
△ Less
Submitted 12 March, 2014; v1 submitted 12 November, 2013;
originally announced November 2013.
-
Search for Rare Nuclear Decays with HPGe Detectors at the STELLA Facility of the LNGS
Authors:
P. Belli,
R. Bernabei,
F. Cappella,
R. Cerulli,
F. A. Danevich,
A. d'Angelo,
S. d'Angelo,
A. Di Marco,
M. L. Di Vacri,
A. Incicchitti,
V. V. Kobychev,
G. P. Kovtun,
N. G. Kovtun,
M. Laubenstein,
S. Nisi,
D. V. Poda,
O. G. Polischuk,
A. P. Shcherban,
D. A. Solopikhin,
J. Suhonen,
A. V. Tolmachev,
V. I. Tretyak,
R. P. Yavetskiy
Abstract:
Results on the search for rare nuclear decays with the ultra low background facility STELLA at the LNGS using gamma ray spectrometry are presented. In particular, the best T1/2 limits were obtained for double beta processes in 96Ru and 104Ru. Several isotopes, which potentially decay through different double beta decay channels, including also possible resonant double electron captures, were inves…
▽ More
Results on the search for rare nuclear decays with the ultra low background facility STELLA at the LNGS using gamma ray spectrometry are presented. In particular, the best T1/2 limits were obtained for double beta processes in 96Ru and 104Ru. Several isotopes, which potentially decay through different double beta decay channels, including also possible resonant double electron captures, were investigated for the first time (156Dy, 158Dy, 184Os, 192Os, 190Pt, 198Pt). Search for resonant absorption of solar 7Li axions in a LiF crystal gave the best limit for the mass of 7Li axions (< 8.6 keV). Rare alpha decay of 190Pt to the first excited level of 186Os (Eexc = 137.2 keV) was observed for the first time.
△ Less
Submitted 14 August, 2013; v1 submitted 12 August, 2013;
originally announced August 2013.