Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the additio…
▽ More
A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.
△ Less
Submitted 16 October, 2023; v1 submitted 2 March, 2023;
originally announced March 2023.
-
Comprehensive Study of Radon Progeny Attachment to Surfaces
Authors:
D. Chernyak,
J. Howell,
D. Majumdar,
N. Mukherjee,
O. Nusair,
A. Piepke
Abstract:
Low energy, low rate experiments, such as searches for neutrinoless double beta decay and dark matter, require unprecedentedly low levels of background in order to deliver their full science potential. $^{210}$Po driven, neutron induced background, caused by nuclear $(α, n)$-reactions on low-Z materials, direct background contributions of the $^{210}$Po $α$-radiation and desorption of the…
▽ More
Low energy, low rate experiments, such as searches for neutrinoless double beta decay and dark matter, require unprecedentedly low levels of background in order to deliver their full science potential. $^{210}$Po driven, neutron induced background, caused by nuclear $(α, n)$-reactions on low-Z materials, direct background contributions of the $^{210}$Po $α$-radiation and desorption of the $^{210}$Pb progeny $^{210}$Bi from surfaces into the detector medium are of particular of concern. These backgrounds depend on details of the components' exposure to radon-loaded lab air and, thus, their handling history. The attachment rates of airborne radon progeny to surfaces, needed for the estimation of these background rates, are poorly understood. This article reports the results of a campaign comprising of more than 1200 attachment measurements, performed for 9 different materials. Correlations of the attachment with environmental parameters such as air exchange rate, electrical surface potential, temperature, atmospheric pressure, and relative humidity have been studied and found to be significant only in case of the first two. Attachment modelling, using the Jacobi model, is compared to data.
△ Less
Submitted 10 May, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
Search for MeV Electron Recoils from Dark Matter in EXO-200
Authors:
EXO-200 Collaboration,
:,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling
, et al. (83 additional authors not shown)
Abstract:
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total…
▽ More
We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.
△ Less
Submitted 20 February, 2023; v1 submitted 2 July, 2022;
originally announced July 2022.
-
Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (81 additional authors not shown)
Abstract:
A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on…
▽ More
A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.
△ Less
Submitted 17 November, 2021; v1 submitted 3 September, 2021;
originally announced September 2021.
-
Sensitivity analysis towards trace-uranium detection with $γ$-$γ$ coincidence NAA
Authors:
Raymond Hei Man Tsang,
Omar Nusair,
Andreas Piepke
Abstract:
We present an improved approach for detection of trace amounts of $^{238}$U by means of neutron activation analysis (NAA). The analysis enhancement is obtained by utilizing $γ$-$γ$ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; nam…
▽ More
We present an improved approach for detection of trace amounts of $^{238}$U by means of neutron activation analysis (NAA). The analysis enhancement is obtained by utilizing $γ$-$γ$ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. A data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two-detector setup. In this counting scheme, a $^{238}$U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.
△ Less
Submitted 15 September, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory
Authors:
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (83 additional authors not shown)
Abstract:
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source d…
▽ More
We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.
△ Less
Submitted 7 May, 2020; v1 submitted 31 January, 2020;
originally announced February 2020.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset
Authors:
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko,
M. J. Dolinski
, et al. (77 additional authors not shown)
Abstract:
A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from…
▽ More
A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from $σ/E=1.23\%$ to $1.15\pm0.02\%$ with the upgraded detector. Accounting for the new data, the median 90% confidence level $0νββ$ half-life sensitivity for this analysis is $5.0 \cdot 10^{25}$ yr with a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $3.5\cdot10^{25}$ yr at the 90% confidence level.
△ Less
Submitted 18 October, 2019; v1 submitted 6 June, 2019;
originally announced June 2019.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Study of the astrophysically important $\boldsymbol{^{23}\mathrm{Na}(α,p)^{26}\mathrm{Mg}}$ and $\boldsymbol{^{23}\mathrm{Na}(α,n)^{26}\mathrm{Al}}$ reactions
Authors:
M. L. Avila,
K. E. Rehm,
S. Almaraz-Calderon,
A. D. Ayangeakaa,
C. Dickerson,
C. R. Hoffman,
C. L. Jiang,
B. P. Kay,
J. Lai,
O. Nusair,
R. C. Pardo,
D. Santiago-Gonzalez,
R. Talwar,
C. Ugalde
Abstract:
The $^{23}$Na$(α,p)^{26}$Mg and $^{23}$Na$(α,n)^{26}$Al reactions are important for our understanding of the $^{26}$Al abundance in massive stars. The aim of this work is to report on a direct and simultaneous measurement of these astrophysically important reactions using an active target system. The reactions were investigated in inverse kinematics using $^{4}$He as the active target gas in the d…
▽ More
The $^{23}$Na$(α,p)^{26}$Mg and $^{23}$Na$(α,n)^{26}$Al reactions are important for our understanding of the $^{26}$Al abundance in massive stars. The aim of this work is to report on a direct and simultaneous measurement of these astrophysically important reactions using an active target system. The reactions were investigated in inverse kinematics using $^{4}$He as the active target gas in the detector. We measured the excitation functions in the energy range of about 2 to 6 MeV in the center of mass. We have found that the cross sections of the $^{23}$Na$(α,p)^{26}$Mg and the $^{23}$Na$(α,n)^{26}$Al reactions are in good agreement with previous experiments, and with statistical model calculations.
△ Less
Submitted 10 August, 2016;
originally announced August 2016.
-
Study of $\boldsymbol{(α,p)}$ and $\boldsymbol{(α,n)}$ reactions with a Multi-Sampling Ionization Chamber
Authors:
M. L. Avila,
K. E. Rehm,
S. Almaraz-Calderon,
A. D. Ayangeakaa,
C. Dickerson,
C. R. Hoffman,
C. L. Jiang,
B. P. Kay,
J. Lai,
O. Nusair,
R. C. Pardo,
D. Santiago-Gonzalez,
R. Talwar,
C. Ugalde
Abstract:
A large number of $(α,p)$ and $(α,n)$ reactions are known to play a fundamental role in nuclear astrophysics. This work presents a novel technique to study these reactions with the active target system MUSIC whose segmented anode allows the investigation of a large energy range of the excitation function with a single beam energy. In order to verify the method, we performed a direct measurements o…
▽ More
A large number of $(α,p)$ and $(α,n)$ reactions are known to play a fundamental role in nuclear astrophysics. This work presents a novel technique to study these reactions with the active target system MUSIC whose segmented anode allows the investigation of a large energy range of the excitation function with a single beam energy. In order to verify the method, we performed a direct measurements of the previously measured reactions $^{17}$O$(α,n)^{20}$Ne, $^{23}$Na$(α,p)^{26}$Mg, and $^{23}$Na$(α,n)^{26}$Al. These reactions were investigated in inverse kinematics using $^{4}$He gas in the detector to study the excitation function in the range of about 2 to 6 MeV in the center of mass. We found good agreement between the cross sections of the $^{17}$O$(α,n)^{20}$Ne reaction measured in this work and previous measurements. Furthermore we have successfully performed a simultaneous measurement of the $^{23}$Na$(α,p)^{26}$Mg and $^{23}$Na$(α,n)^{26}$Al reactions.
△ Less
Submitted 10 August, 2016;
originally announced August 2016.
-
Independent measurement of the Hoyle state $β$ feeding from 12B using Gammasphere
Authors:
M. Munch,
M. Alcorta,
H. O. U. Fynbo,
M. Albers,
S. Almaraz-Calderon,
M. L. Avila,
A. D. Ayangeakaa,
B. B. Back,
P. F. Bertone,
P. F. F. Carnelli,
M. P. Carpenter,
C. J. Chiara,
J. A. Clark,
B. DiGiovine,
J. P. Greene,
J. L. Harker,
C. R. Hoffman,
N. J. Hubbard,
C. L. Jiang,
O. S. Kirsebom,
T. Lauritsen,
K. L. Laursen,
S. T. Marley,
C. Nair,
O. Nusair
, et al. (6 additional authors not shown)
Abstract:
Using an array of high-purity Compton-suppressed germanium detectors, we performed an independent measurement of the $β$-decay branching ratio from $^{12}\mathrm{B}$ to the second-excited (Hoyle) state in $^{12}\mathrm{C}$. Our result is $0.64(11)\%$, which is a factor $\sim 2$ smaller than the previously established literature value, but is in agreement with another recent measurement. This could…
▽ More
Using an array of high-purity Compton-suppressed germanium detectors, we performed an independent measurement of the $β$-decay branching ratio from $^{12}\mathrm{B}$ to the second-excited (Hoyle) state in $^{12}\mathrm{C}$. Our result is $0.64(11)\%$, which is a factor $\sim 2$ smaller than the previously established literature value, but is in agreement with another recent measurement. This could indicate that the Hoyle state is more clustered than previously believed. The angular correlation of the Hoyle state $γ$ cascade has also been measured for the first time. It is consistent with theoretical predictions.
△ Less
Submitted 27 May, 2016; v1 submitted 12 January, 2016;
originally announced January 2016.
-
Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons
Authors:
M. Röder,
Z. Elekes,
T. Aumann,
D. Bemmerer,
K. Boretzky,
C. Caesar,
T. E. Cowan,
J. Hehner,
M. Heil,
M. Kempe,
V. Maroussov,
O. Nusair,
A. V. Prokofiev,
R. Reifarth,
M. Sobiella,
D. Stach,
A. Wagner,
D. Yakorev,
A. Zilges,
K. Zuber
Abstract:
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypotheti…
▽ More
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment.
△ Less
Submitted 10 July, 2014; v1 submitted 23 June, 2014;
originally announced June 2014.