-
Transverse asymmetry of individual $γ$-rays in the $^{139}$La($\vec{n}$, $γ$)$^{140}$La reaction
Authors:
M. Okuizumi,
C. J. Auton,
S. Endo,
H. Fujioka,
K. Hirota,
T. Ino,
K. Ishizaki,
A. Kimura,
M. Kitaguchi,
J. Koga,
S. Makise,
Y. Niinomi,
T. Oku,
T. Okudaira,
K. Sakai,
T. Shima,
H. M. Shimizu,
H. Tada,
S. Takada,
S. Takahashi,
Y. Tani,
T. Yamamoto,
H. Yoshikawa,
T. Yoshioka
Abstract:
The enhancement of the parity-violating asymmetry in the vicinity of $p$-wave compound nuclear resonances was observed for a variety of medium-heavy nuclei. The enhanced parity-violating asymmetry can be understood using the $s$-$p$ mixing model. The $s$-$p$ mixing model predicts several neutron energy-dependent angular correlations between the neutron momentum $\vec k_n$, neutron spin $\vecσ_n$,…
▽ More
The enhancement of the parity-violating asymmetry in the vicinity of $p$-wave compound nuclear resonances was observed for a variety of medium-heavy nuclei. The enhanced parity-violating asymmetry can be understood using the $s$-$p$ mixing model. The $s$-$p$ mixing model predicts several neutron energy-dependent angular correlations between the neutron momentum $\vec k_n$, neutron spin $\vecσ_n$, $γ$-ray momentum $\vec k_γ$, and $γ$-ray polarization $\vecσ_γ$ in the $(n,γ)$ reaction. In this paper, the improved value of the transverse asymmetry of $γ$-ray emissions, corresponding to a correlation term $\vecσ_n\cdot(\vec k_n\times\vec k_γ)$ in the $^{139}\mathrm{La}(\vec n,γ)^{140}\mathrm{La}$ reaction, and the transverse asymmetries in the transitions to several low excited states of $^{140}\mathrm{La}$ are reported.
△ Less
Submitted 29 February, 2024;
originally announced February 2024.
-
Performance of the Fully-equipped Spin Flip Chopper For Neutron Lifetime Experiment at J-PARC
Authors:
K. Mishima,
G. Ichikawa,
Y. Fuwa,
T. Hasegawa,
M. Hino,
R. Hosokawa,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
S. Matsuzaki,
T. Mogi,
H. Okabe,
T. Oku,
T. Okudaira,
Y. Seki,
H. E. Shimizu,
H. M. Shimizu,
S. Takahashi,
M. Tanida,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic su…
▽ More
To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250-400 comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in statistic will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.
△ Less
Submitted 31 July, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
High sensitivity of a future search for P-odd/T-odd interactions on the 0.75 eV $p$-wave resonance in $\vec{n}+^{139}\vec{\rm La}$ forward transmission determined using pulsed neutron beam
Authors:
R. Nakabe,
C. J. Auton,
S. Endo,
H. Fujioka,
V. Gudkov,
K. Hirota,
I. Ide,
T. Ino,
M. Ishikado,
W. Kambara,
S. Kawamura,
A. Kimura,
M. Kitaguchi,
R. Kobayashi,
T. Okamura,
T. Oku,
T. Okudaira,
M. Okuizumi,
J. G. Otero Munoz,
J. D. Parker,
K. Sakai,
T. Shima,
H. M. Shimizu,
T. Shinohara,
W. M. Snow
, et al. (5 additional authors not shown)
Abstract:
Neutron transmission experiments can offer a new type of highly sensitive search for time-reversal invariance violating (TRIV) effects in nucleon-nucleon interactions via the same enhancement mechanism observed for large parity violating (PV) effects in neutron-induced compound nuclear processes. In these compound processes, the TRIV cross-section is given as the product of the PV cross-section, a…
▽ More
Neutron transmission experiments can offer a new type of highly sensitive search for time-reversal invariance violating (TRIV) effects in nucleon-nucleon interactions via the same enhancement mechanism observed for large parity violating (PV) effects in neutron-induced compound nuclear processes. In these compound processes, the TRIV cross-section is given as the product of the PV cross-section, a spin-factor $κ$, and a ratio of TRIV and PV matrix elements. We determined $κ$ to be $0.59\pm0.05$ for $^{139}$La+$n$ using both $(n, γ)$ spectroscopy and ($\vec{n}+^{139}\vec{\rm La}$) transmission. This result quantifies for the first time the high sensitivity of the $^{139}$La 0.75~eV $p$-wave resonance in a future search for P-odd/T-odd interactions in ($\vec{n}+^{139}\vec{\rm La}$) forward transmission.
△ Less
Submitted 10 December, 2023;
originally announced December 2023.
-
Spin dependence in the $p$-wave resonance of ${^{139}\vec{\rm{La}}+\vec{n}}$
Authors:
T. Okudaira,
R. Nakabe,
S. Endo,
H. Fujioka,
V. Gudkov,
I. Ide,
T. Ino,
M. Ishikado,
W. Kambara,
S. Kawamura,
R. Kobayashi,
M. Kitaguchi,
T. Okamura,
T. Oku,
J. G. Otero Munoz,
J. D. Parker,
K. Sakai,
T. Shima,
H. M. Shimizu,
T. Shinohara,
W. M. Snow,
S. Takada,
Y. Tsuchikawa,
R. Takahashi,
S. Takahashi
, et al. (2 additional authors not shown)
Abstract:
We measured the spin dependence in a neutron-induced $p$-wave resonance by using a polarized epithermal neutron beam and a polarized nuclear target. Our study focuses on the 0.75~eV $p$-wave resonance state of $^{139}$La+$n$, where largely enhanced parity violation has been observed. We determined the partial neutron width of the $p$-wave resonance by measuring the spin dependence of the neutron a…
▽ More
We measured the spin dependence in a neutron-induced $p$-wave resonance by using a polarized epithermal neutron beam and a polarized nuclear target. Our study focuses on the 0.75~eV $p$-wave resonance state of $^{139}$La+$n$, where largely enhanced parity violation has been observed. We determined the partial neutron width of the $p$-wave resonance by measuring the spin dependence of the neutron absorption cross section between polarized $^{139}\rm{La}$ and polarized neutrons. Our findings serve as a foundation for the quantitative study of the enhancement effect of the discrete symmetry violations caused by mixing between partial amplitudes in the compound nuclei.
△ Less
Submitted 16 September, 2023;
originally announced September 2023.
-
Measurement of the transverse asymmetry of $γ$-rays in the $^{117}$Sn(n,$γ$)$^{118}$Sn reaction
Authors:
S. Endo,
T. Okudaira,
R. Abe,
H. Fujioka,
K. Hirota,
A. Kimura,
M. Kitaguchi,
T. Oku,
K. Sakai,
T. Shima,
H. M. Shimizu,
S. Takada,
S. Takahashi,
T. Yamamoto,
H. Yoshikawa,
T. Yoshioka
Abstract:
Largely enhanced parity-violating effects observed in compound resonances induced by epithermal neutrons are currently attributed to the mixing of parity-unfavored partial amplitudes in the entrance channel of the compound states. Furthermore, it is proposed that the same mechanism that enhances the parity-violation also enhances the breaking of time-reversal-invariance in the compound nucleus. Th…
▽ More
Largely enhanced parity-violating effects observed in compound resonances induced by epithermal neutrons are currently attributed to the mixing of parity-unfavored partial amplitudes in the entrance channel of the compound states. Furthermore, it is proposed that the same mechanism that enhances the parity-violation also enhances the breaking of time-reversal-invariance in the compound nucleus. The entrance-channel mixing induces energy-dependent spin-angular correlations of individual $γ$-rays emitted from the compound nuclear state. For a detailed study of the mixing model, a $γ$-ray yield in the reaction of $^{117}$Sn(n,$γ$)$^{118}$Sn was measured using the pulsed beam of polarized epithermal neutrons and Ge detectors. An angular dependence of asymmetric $γ$-ray yields for the orientation of the neutron polarization was observed.
△ Less
Submitted 27 October, 2022;
originally announced October 2022.
-
Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor
Authors:
The Dang Vu,
Hiroaki Shishido,
Kazuya Aizawa,
Kenji M. Kojima,
Tomio Koyama,
Kenichi Oikawa,
Masahide Harada,
Takayuki Oku,
Kazuhiko Soyama,
Shigeyuki Miyajima,
Mutsuo Hidaka,
Soh Y. Suzuki,
Manobu M. Tanakai,
Alex Malins,
Masahiko Machida,
Shuichi Kawamata,
Takekazu Ishida
Abstract:
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission and scanning electron microscope (SEM) images of Gd islands with sizes between 15 and 130 micrometer which were thermally-sprayed onto a Si substrate. Neutron tr…
▽ More
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission and scanning electron microscope (SEM) images of Gd islands with sizes between 15 and 130 micrometer which were thermally-sprayed onto a Si substrate. Neutron transmission images could be used to identify tiny voids in a thermally-sprayed continuous Gd2O3 film on a Si substrate which could not be seen in SEM images. We also found that neutron transmission images revealed pattern formations, mosaic features and co-existing dendritic phases in Wood's metal samples with constituent elements Bi, Pb, Sn and Cd. These results demonstrate the merits of the current-biased kinetic inductance detector (CB-KID) system for practical studies in materials science. Moreover, we found that operating the detector at a more optimal temperature (7.9 K) appreciably improved the effective detection efficiency when compared to previous studies conducted at 4 K. This is because the effective size of hot-spots in the superconducting meanderline planes increases with temperature, which makes particle detections more likely.
△ Less
Submitted 8 May, 2021;
originally announced May 2021.
-
Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector
Authors:
The Dang Vu,
Hiroaki Shishido,
Kenji M. Kojima,
Tomio Koyama,
Kenichi Oikawa,
Masahide Harada,
Shigeyuki Miyajima,
Takayuki Oku,
Kazuhiko Soyama,
Kazuya Aizawa,
Mutsuo Hidaka,
Soh Y. Suzuki,
Manobu M. Tanaka,
Alex Malins,
Masahiko Machida,
Takekazu Ishida
Abstract:
We previously proposed a method to detect neutrons by using a current-biased kinetic inductance detector (CB-KID), where neutrons are converted into charged particles using a 10B conversion layer. The charged particles are detected based on local changes in kinetic inductance of X and Y superconducting meanderlines under a modest DC bias current. The system uses a delay-line method to locate the p…
▽ More
We previously proposed a method to detect neutrons by using a current-biased kinetic inductance detector (CB-KID), where neutrons are converted into charged particles using a 10B conversion layer. The charged particles are detected based on local changes in kinetic inductance of X and Y superconducting meanderlines under a modest DC bias current. The system uses a delay-line method to locate the positions of neutron-10B reactions by acquiring the four arrival timestamps of signals that propagate from hot spots created by a passing charged particle to the end electrodes of the meanderlines. Unlike conventional multi-pixel imaging systems, the CB-KID system performs high spatial resolution imaging over a 15 mm x 15 mm sensitive area using only four channel readouts. Given the large sensitive area, it is important to check the spatial homogeneity and linearity of detected neutron positions when imaging with CB-KID. To this end we imaged a pattern of 10B dot absorbers with a precise dot pitch to investigate the spatial homogeneity of the detector. We confirmed the spatial homogeneity of detected dot positions based on the distribution of measured dot pitches across the sensitive area of the detector. We demonstrate potential applications of the system by taking a clear transmission image of tiny metallic screws and nuts and a ladybug. The image was useful for characterizing the ladybug noninvasively. Detection efficiencies were low when the detector was operated at 4 K, so we plan to explore raising the operating temperature towards the critical temperature of the detector as a means to improve counting rates.
△ Less
Submitted 14 October, 2020;
originally announced October 2020.
-
Transverse asymmetry of $γ$ rays from neutron-induced compound states of ${}^{140}{\rm La}$
Authors:
T. Yamamoto,
T. Okudaira,
S. Endo,
H. Fujioka,
K. Hirota,
T. Ino,
K. Ishizaki,
A. Kimura,
M. Kitaguchi,
J. Koga,
S. Makise,
Y. Niinomi,
T. Oku,
K. Sakai,
T. Shima,
H. M. Shimizu,
S. Takada,
Y. Tani,
H. Yoshikawa,
T. Yoshioka
Abstract:
A correlation term ${{ σ}_{n} }\cdot ({ k_{n}\times k_γ}) $ in the ${}^{139}{\rm La}(\vec{n},γ)$ reaction has been studied utilizing epithermal polarized neutrons and germanium detectors. The transverse asymmetry for single $γ$-ray transition was measured to be $0.60\pm0.19$ in the $p$-wave resonance.
A correlation term ${{ σ}_{n} }\cdot ({ k_{n}\times k_γ}) $ in the ${}^{139}{\rm La}(\vec{n},γ)$ reaction has been studied utilizing epithermal polarized neutrons and germanium detectors. The transverse asymmetry for single $γ$-ray transition was measured to be $0.60\pm0.19$ in the $p$-wave resonance.
△ Less
Submitted 20 February, 2020;
originally announced February 2020.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
Neutron imaging detector based on the muPIC micro-pixel chamber
Authors:
J. D. Parker,
K. Hattori,
H. Fujioka,
M. Harada,
S. Iwaki,
S. Kabuki,
Y. Kishimoto,
H. Kubo,
S. Kurosawa,
K. Miuchi,
T. Nagae,
H. Nishimura,
T. Oku,
T. Sawano,
T. Shinohara,
J. Suzuki,
A. Takada,
T. Tanimori,
K. Ueno
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measur…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.