-
Re-publication of the data from the BILL magnetic spectrometer: The cumulative $β$ spectra of the fission products of $^{235}$U, $^{239}$Pu, and $^{241}$Pu
Authors:
N. Haag,
W. Gelletly,
F. von Feilitzsch,
L. Oberauer,
W. Potzel,
K. Schreckenbach,
A. A. Sonzogni
Abstract:
In the 1980s, measurements of the cumulative $β$ spectra of the fission products following the thermal neutron induced fission of $^{235}$U, $^{239}$Pu, and $^{241}$Pu were performed at the magnetic spectrometer BILL at the ILL in Grenoble. This data was published in bins of 250 keV. In this paper, we re-publish the original data in a binning of 50 keV for $^{235}$U and 100 keV for $^{239}$Pu and…
▽ More
In the 1980s, measurements of the cumulative $β$ spectra of the fission products following the thermal neutron induced fission of $^{235}$U, $^{239}$Pu, and $^{241}$Pu were performed at the magnetic spectrometer BILL at the ILL in Grenoble. This data was published in bins of 250 keV. In this paper, we re-publish the original data in a binning of 50 keV for $^{235}$U and 100 keV for $^{239}$Pu and $^{241}$Pu.
△ Less
Submitted 30 May, 2014; v1 submitted 14 May, 2014;
originally announced May 2014.
-
Experimental Determination of the Antineutrino Spectrum of the Fission Products of $^{238}$U
Authors:
N. Haag,
A. Gütlein,
M. Hofmann,
L. Oberauer,
W. Potzel,
K. Schreckenbach,
F. M. Wagner
Abstract:
An experiment was performed at the scientific neutron source FRM II in Garching to determine the cumulative antineutrino spectrum of the fission products of $^{238}$U. This was achieved by irradiating target foils of natural uranium with a thermal and a fast neutron beam and recording the emitted $β$-spectra with a gamma-suppressing electron-telescope. The obtained $β$-spectrum of the fission prod…
▽ More
An experiment was performed at the scientific neutron source FRM II in Garching to determine the cumulative antineutrino spectrum of the fission products of $^{238}$U. This was achieved by irradiating target foils of natural uranium with a thermal and a fast neutron beam and recording the emitted $β$-spectra with a gamma-suppressing electron-telescope. The obtained $β$-spectrum of the fission products of $^{235}$U was normalized to the data of the magnetic spectrometer BILL of $^{235}$U. This method strongly reduces systematic errors in the $^{238}$U measurement. The $β$-spectrum of $^{238}$U was converted into the corresponding antineutrino spectrum. The final $\barν_e$-spectrum is given in 250 keV bins in the range from 2.875 MeV to 7.625 MeV with an energy-dependent error of 3.5 % at 3 MeV, 7.6 % at 6 MeV and $\gtrsim$ 14 % at energies $\gtrsim$ 7 MeV (68 % confidence level). Furthermore, an energy-independent uncertainty of $\sim$ 3.3 % due to the absolute normalization is added. Compared to the generally used summation calculations, the obtained spectrum reveals a slight spectral distortion of $\sim$ 10 % but returns the same value for the mean cross section per fission for the inverse beta decay.
△ Less
Submitted 19 December, 2013;
originally announced December 2013.
-
High-Intensity and High-Brightness Source of Moderated Positrons Using a Brilliant gamma Beam
Authors:
C. Hugenschmidt,
K. Schreckenbach,
D. Habs,
P. G. Thirolf
Abstract:
Presently large efforts are conducted towards the development of highly brilliant gamma beams via Compton back scattering of photons from a high-brilliance electron beam, either on the basis of a normal-conducting electron linac or a (superconducting) Energy Recovery Linac (ERL). Particularly ERL's provide an extremely brilliant electron beam, thus enabling to generate highest-quality gamma beams.…
▽ More
Presently large efforts are conducted towards the development of highly brilliant gamma beams via Compton back scattering of photons from a high-brilliance electron beam, either on the basis of a normal-conducting electron linac or a (superconducting) Energy Recovery Linac (ERL). Particularly ERL's provide an extremely brilliant electron beam, thus enabling to generate highest-quality gamma beams. A 2.5 MeV gamma beam with an envisaged intensity of 10^15 s^-1, as ultimately envisaged for an ERL-based gamma-beam facility, narrow band width (10^-3), and extremely low emittance (10^-4 mm^2 mrad^2) offers the possibility to produce a high-intensity bright polarized positron beam. Pair production in a face-on irradiated W converter foil (200 micron thick, 10 mm long) would lead to the emission of 2 x 10^13 (fast) positrons per second, which is four orders of magnitude higher compared to strong radioactive ^22Na sources conventionally used in the laboratory.Using a stack of converter foils and subsequent positron moderation, a high-intensity low-energy beam of moderated positrons can be produced. Two different source setups are presented: a high-brightness positron beam with a diameter as low as 0.2 mm, and a high-intensity beam of 3 x 10^11 moderated positrons per second. Hence, profiting from an improved moderation efficiency, the envisaged positron intensity would exceed that of present high-intensity positron sources by a factor of 100.
△ Less
Submitted 14 April, 2011; v1 submitted 2 March, 2011;
originally announced March 2011.