Characterizing and correcting electron and hole trapping in germanium cross-strip detectors
Authors:
Sean N. Pike,
Steven E. Boggs,
Jacqueline Beechert,
Jarred Roberts,
Albert Y. Shih,
John A. Tomsick,
Andreas Zoglauer
Abstract:
We present measurements of electron and hole trapping in three COSI germanium cross-strip detectors. By characterizing the relative charge collection efficiency (CCE) as a function of interaction depth, we show that intrinsic trapping of both electrons and holes have significant effects on the spectroscopic performance of the detectors. We find that both the electron and hole trapping vary from de…
▽ More
We present measurements of electron and hole trapping in three COSI germanium cross-strip detectors. By characterizing the relative charge collection efficiency (CCE) as a function of interaction depth, we show that intrinsic trapping of both electrons and holes have significant effects on the spectroscopic performance of the detectors. We find that both the electron and hole trapping vary from detector to detector, demonstrating the need for empirical trapping measurements and corrections. Using our measurements of charge trapping, we develop a continuous depth-dependent second-order energy correction procedure. We show that applying this empirical trapping correction produces significant improvements to spectral resolution and to the accuracy of the energy reconstruction.
△ Less
Submitted 24 October, 2023; v1 submitted 14 June, 2023;
originally announced June 2023.
-
The e-ASTROGAM mission (exploring the extreme Universe with gamma rays in the MeV-GeV range)
Authors:
Alessandro De Angelis,
Vincent Tatischeff,
Marco Tavani,
Uwe Oberlack,
Isabelle A. Grenier,
Lorraine Hanlon,
Roland Walter,
Andrea Argan,
Peter von Ballmoos,
Andrea Bulgarelli,
Immacolata Donnarumma,
Margarita Hernanz,
Irfan Kuvvetli,
Mark Pearce,
Andrzej Zdziarski,
Alessio Aboudan,
Marco Ajello,
Giovanni Ambrosi,
Denis Bernard,
Elisa Bernardini,
Valter Bonvicini,
Andrea Brogna,
Marica Branchesi,
Carl Budtz-Jorgensen,
Andrei Bykov
, et al. (49 additional authors not shown)
Abstract:
e-ASTROGAM (`enhanced ASTROGAM') is a breakthrough Observatory mission dedicated to the study of the non-thermal Universe in the photon energy range from 0.3 MeV to 3 GeV. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with polarimetric capability. In the largely unexplored MeV-GeV domain, e-ASTROGAM wil…
▽ More
e-ASTROGAM (`enhanced ASTROGAM') is a breakthrough Observatory mission dedicated to the study of the non-thermal Universe in the photon energy range from 0.3 MeV to 3 GeV. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with polarimetric capability. In the largely unexplored MeV-GeV domain, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the most powerful Galactic and extragalactic sources, elucidating the nature of their relativistic outflows and their effects on Galactic ecosystems. With a line sensitivity in the MeV energy range one to two orders of magnitude better than previous generation instruments, will determine the origin of key isotopes fundamental for the understanding of supernova explosion and the chemical evolution of our Galaxy. The mission will provide unique data of significant interest to a broad astronomical community, complementary to powerful observatories such as LIGO-Virgo-GEO600-KAGRA, SKA, ALMA, E-ELT, TMT, LSST, JWST, Athena, CTA, IceCube, KM3NeT, and the promise of eLISA.
Keywords: High-energy gamma-ray astronomy, High-energy astrophysics, Nuclear Astrophysics, Compton and Pair creation telescope, Gamma-ray bursts, Active Galactic Nuclei, Jets, Outflows, Multiwavelength observations of the Universe, Counterparts of gravitational waves, Fermi, Dark Matter, Nucleosynthesis, Early Universe, Supernovae, Cosmic Rays, Cosmic antimatter.
△ Less
Submitted 4 June, 2017; v1 submitted 7 November, 2016;
originally announced November 2016.
-
Validation of Geant4-based Radioactive Decay Simulation
Authors:
Steffen Hauf,
Markus Kuster,
Matej Batič,
Zane W. Bell,
Dieter H. H. Hoffmann,
Philipp M. Lang,
Stephan Neff,
Maria Grazia Pia,
Georg Weidenspointner,
Andreas Zoglauer
Abstract:
Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of ra…
▽ More
Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of radioactive decays, which, in addition to being able to use a refactored per-decay sampling, is capable of using a statistical sampling approach. The validation is based on measurements of calibration isotope sources using a high purity Germanium (HPGe) detector; no calibration of the simulation is performed. For the considered validation experiment equivalent simulation accuracy can be achieved with per-decay and statistical sampling.
△ Less
Submitted 21 June, 2013;
originally announced June 2013.
-
Submillimeter nuclear medical imaging with a Compton Camera using triple coincidences of collinear β+ annihilation photons and γ-rays
Authors:
C. Lang,
D. Habs,
P. G. Thirolf,
A. Zoglauer
Abstract:
Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of the 511 keV photons within the patient limit the performance of PET. We present a nuclear medical imaging technique, able to reach submillimeter spatial resoluti…
▽ More
Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of the 511 keV photons within the patient limit the performance of PET. We present a nuclear medical imaging technique, able to reach submillimeter spatial resolution in 3 dimensions with a reduced activity application compared to conventional PET. This 'gamma-PET' technique draws on specific positron sources simultaneously emitting an additional photon with the β+ decay. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to test the feasibility of this technique, Monte-Carlo simulations and image reconstruction has been performed. The spatial resolution amounts to 0.2 mm (FWHM) in each direction, surpassing the performance of conventional PET by about an order of magnitude. The simulated detector geometry exhibits a coincidence detection efficiency of 1.92e-7 per decay. Starting with only 0.7 MBq of source activity (ca. 200-500 times less compared to conventional PET) an exposure time of 450 s is sufficient for source reconstruction.
△ Less
Submitted 2 February, 2012;
originally announced February 2012.
-
The Advanced Compton Telescope Mission
Authors:
Steven E. Boggs,
James Kurfess,
James Ryan,
Elena Aprile,
Neil Gehrels,
Marc Kippen,
Mark Leising,
Uwe Oberlack,
Cornelia Wunderer,
Allen Zych,
Peter Bloser,
Michael Harris,
Andrew Hoover,
Alexei Klimenk,
Dan Kocevski,
Mark McConnell,
Peter Milne,
Elena I. Novikova,
Bernard Phlips,
Mark Polsen,
Steven Sturner,
Derek Tournear,
Georg Weidenspointner,
Eric Wulf,
Andreas Zoglauer
, et al. (8 additional authors not shown)
Abstract:
The Advanced Compton Telescope (ACT), the next major step in gamma-ray astronomy, will probe the fires where chemical elements are formed by enabling high-resolution spectroscopy of nuclear emission from supernova explosions. During the past two years, our collaboration has been undertaking a NASA mission concept study for ACT. This study was designed to (1) transform the key scientific objectiv…
▽ More
The Advanced Compton Telescope (ACT), the next major step in gamma-ray astronomy, will probe the fires where chemical elements are formed by enabling high-resolution spectroscopy of nuclear emission from supernova explosions. During the past two years, our collaboration has been undertaking a NASA mission concept study for ACT. This study was designed to (1) transform the key scientific objectives into specific instrument requirements, (2) to identify the most promising technologies to meet those requirements, and (3) to design a viable mission concept for this instrument. We present the results of this study, including scientific goals and expected performance, mission design, and technology recommendations.
△ Less
Submitted 24 August, 2006;