Design and performance of a CMOS study sensor for a binary readout electromagnetic calorimeter
Authors:
J. A. Ballin,
R. Coath,
J. P. Crooks,
P. D. Dauncey,
A. -M. Magnan,
Y. Mikami,
O. D. Miller,
M. Noy,
V. Rajovic,
M. Stanitzki,
K. D. Stefanov,
R. Turchetta,
M. Tyndel,
E. G. Villani,
N. K. Watson,
J. A. Wilson,
Z. Zhang
Abstract:
We present a study of a CMOS test sensor which has been designed, fabricated and characterised to investigate the parameters required for a binary readout electromagnetic calorimeter. The sensors were fabricated with several enhancements in addition to standard CMOS processing. Detailed simulations and experimental results of the performance of the sensor are presented. The sensor and pixels are s…
▽ More
We present a study of a CMOS test sensor which has been designed, fabricated and characterised to investigate the parameters required for a binary readout electromagnetic calorimeter. The sensors were fabricated with several enhancements in addition to standard CMOS processing. Detailed simulations and experimental results of the performance of the sensor are presented. The sensor and pixels are shown to behave in accordance with expectations and the processing enhancements are found to be essential to achieve the performance required.
△ Less
Submitted 4 May, 2011; v1 submitted 22 March, 2011;
originally announced March 2011.
-
Electromagnetic response of a highly granular hadronic calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
Y. Mikami,
N. K. Watson T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward W. Yan
, et al. (142 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM).
A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes.
The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.
△ Less
Submitted 8 June, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.
-
A digital ECAL based on MAPS
Authors:
J. A. Ballin,
P. D. Dauncey,
A. -M. Magnan,
M. Noy,
Y. Mikami,
O. Miller,
V. Rajovic,
N. K. Watson,
J. A. Wilson,
J. P. Crooks,
M. Stanitzki,
K. D. Stefanov,
R. Turchetta,
M. Tyndel,
E. G. Villani
Abstract:
Progress is reported on the development and testing of Monolithic Active Pixel Sensors (MAPS) for a Si-W ECAL for the ILC. Using laser and source setups, a first version of the sensor has been characterised through measurements of the absolute gain calibration, noise and pedestal. The pixel-to-pixel gain spread is 10%. Charge diffusion has been measured and found to be compatible with simulation…
▽ More
Progress is reported on the development and testing of Monolithic Active Pixel Sensors (MAPS) for a Si-W ECAL for the ILC. Using laser and source setups, a first version of the sensor has been characterised through measurements of the absolute gain calibration, noise and pedestal. The pixel-to-pixel gain spread is 10%. Charge diffusion has been measured and found to be compatible with simulation results. The charge collected by a single pixel varies from 50% to 20% depending on where it is generated. After adding detector effects to the Geant4 simulation of an ILC-like ECAL, using the measured parameters, the energy resolution is found to be 35% higher than the ideal resolution, but is still lower than the resolution obtained for an equivalent analogue ECAL.
△ Less
Submitted 28 January, 2009;
originally announced January 2009.
-
Monolithic Active Pixel Sensors (MAPS) in a quadruple well technology for nearly 100% fill factor and full CMOS pixels
Authors:
J. A. Ballin,
J. P. Crooks,
P. D. Dauncey,
A. -M. Magnan,
Y. Mikami,
O. D. Miller,
M. Noy,
V. Rajovic,
M. M. Stanitzki,
K. D. Stefanov,
R. Turchetta,
M. Tyndel,
E. G. Villani,
N. K. Watson,
J. A. Wilson
Abstract:
In this paper we present a novel, quadruple well process developed in a modern 0.18mu CMOS technology called INMAPS. On top of the standard process, we have added a deep P implant that can be used to form a deep P-well and provide screening of N-wells from the P-doped epitaxial layer. This prevents the collection of radiation-induced charge by unrelated N-wells, typically ones where PMOS transis…
▽ More
In this paper we present a novel, quadruple well process developed in a modern 0.18mu CMOS technology called INMAPS. On top of the standard process, we have added a deep P implant that can be used to form a deep P-well and provide screening of N-wells from the P-doped epitaxial layer. This prevents the collection of radiation-induced charge by unrelated N-wells, typically ones where PMOS transistors are integrated. The design of a sensor specifically tailored to a particle physics experiment is presented, where each 50mu pixel has over 150 PMOS and NMOS transistors. The sensor has been fabricated in the INMAPS process and first experimental evidence of the effectiveness of this process on charge collection is presented, showing a significant improvement in efficiency.
△ Less
Submitted 18 July, 2008;
originally announced July 2008.
-
A MAPS-based Digital Electromagnetic Calorimeter for the ILC
Authors:
J. A. Ballin,
P. D. Dauncey,
A. -M. Magnan,
M. Noy,
Y. Mikami,
O. Miller,
V. Rajović,
N. K. Watson,
J. A. Wilson,
J. P. Crooks,
M. Stanitzki,
K. D. Stefanov,
R. Turchetta,
M. Tyndel,
E. G. Villani
Abstract:
A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical sensor is done using a detailed three-dimensional charge spread algorithm. Physics studies of the sensor are done including a digitisation algorithm taking int…
▽ More
A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical sensor is done using a detailed three-dimensional charge spread algorithm. Physics studies of the sensor are done including a digitisation algorithm taking into account the charge sharing, charge collection efficiency, noise, and dead areas. The influence of the charge sharing effect is found to be important and hence needs to be measured precisely.
△ Less
Submitted 10 September, 2007;
originally announced September 2007.