Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
G. Arnau Izquierdo,
M. Baldini,
A. Ballarino,
C. Barth,
A. Ben Yahia,
J. Blowers,
P. Borges De Sousa,
R. Bossert,
B. Bulat,
R. Carcagno,
D. W. Cheng,
G. Chlachidze,
L. Cooley,
M. Crouvizier,
A. Devred,
J. DiMarco,
S. Feher,
P. Ferracin,
J. Ferradas Troitino,
L. Garcia Fajardo,
S. Gourlay
, et al. (33 additional authors not shown)
Abstract:
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of th…
▽ More
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Determination of the electromechanical limits of high-performance Nb$_3$Sn Rutherford cables under transverse stress from a single-wire experiment
Authors:
Luc Gamperle,
Jose Ferradas,
Christian Barth,
Bernardo Bordini,
Davide Tommasini,
Carmine Senatore
Abstract:
The development of high-field accelerator magnets capable of providing 16 T dipolar fields is an indispensable technological breakthrough needed for the 100 TeV energy-frontier targeted by the Future Circular Collider (FCC). As these magnets will be based on Nb$_3$Sn Rutherford cables, the degradation of the conductor performance due to the large electro-magnetic stresses becomes a parameter with…
▽ More
The development of high-field accelerator magnets capable of providing 16 T dipolar fields is an indispensable technological breakthrough needed for the 100 TeV energy-frontier targeted by the Future Circular Collider (FCC). As these magnets will be based on Nb$_3$Sn Rutherford cables, the degradation of the conductor performance due to the large electro-magnetic stresses becomes a parameter with a profound impact on the magnet design. In this work, we investigated the stress dependence and the irreversible reduction of the critical current under compressive transverse load in high performance Powder-In-Tube (PIT) Nb$_3$Sn wires. Tests were performed in magnetic fields ranging between 16 T and 19 T on wires that were resin-impregnated similarly to the wires in the Rutherford cables of accelerator magnets. The scope was to predict the degradation of the cable under stress from a single-wire experiment. Interestingly, the irreversible stress limit, $σ_{irr}$, defined as the stress level corresponding to a permanent reduction of the critical current by 5$\%$ with respect to its initial value, was found to depend on the applied magnetic field. This observation allowed us to shed light on the mechanism dominating the irreversible reduction of the wire performance and to compare and reconcile our results with the irreversible limits measured on Rutherford cables, typically tested at fields below 12 T.
△ Less
Submitted 30 September, 2019;
originally announced September 2019.
-
Nanophotonic enhanced two-photon excited photoluminescence of perovskite quantum dots
Authors:
Christiane Becker,
Sven Burger,
Carlo Barth,
Phillip Manley,
Klaus Jäger,
David Eisenhauer,
Grit Köppel,
Pavel Chabera,
Junsheng Chen,
Kaibo Zheng,
Tönu Pullerits
Abstract:
All-inorganic CsPbBr3 perovskite colloidal quantum dots have recently emerged as promising material for a variety of optoelectronic applications, among others for multi-photon-pumped lasing. Nevertheless, high irradiance levels are generally required for such multi-photon processes. One strategy to enhance the multi-photon absorption is taking advantage of high local light intensities using photon…
▽ More
All-inorganic CsPbBr3 perovskite colloidal quantum dots have recently emerged as promising material for a variety of optoelectronic applications, among others for multi-photon-pumped lasing. Nevertheless, high irradiance levels are generally required for such multi-photon processes. One strategy to enhance the multi-photon absorption is taking advantage of high local light intensities using photonic nanostructures. Here, we investigate two-photon-excited photoluminescence of CsPbBr3 perovskite quantum dots on a silicon photonic crystal slab. By systematic excitation of optical resonances using a pulsed near-infrared laser beam, we observe an enhancement of two-photon-pumped photoluminescence by more than one order of magnitude when comparing to using a bulk silicon film. Experimental and numerical analyses allow relating these findings to near-field enhancement effects on the nanostructured silicon surface. The results reveal a promising approach for significant decreasing the required irradiance levels for multi-photon processes being of advantage in applications like low-threshold lasing, biomedical imaging, lighting and solar energy.
△ Less
Submitted 3 August, 2018;
originally announced August 2018.
-
A high-resolution carbon balance in a temperate catchment: insights from the Schwabach River, Germany
Authors:
Kern Y. Lee,
Robert van Geldern,
Johannes A. C. Barth
Abstract:
This study examines stable carbon isotope (d13C) and concentration dynamics of DIC, DOC, and POC over an entire year, using a high resolution dataset. This research was performed in the catchment of the Schwabach River, a small, karstic headwater stream in Germany. The DIC data indicated the dominance of mineral weathering as a DIC source, with a dilution effect during high flow periods. A weakly…
▽ More
This study examines stable carbon isotope (d13C) and concentration dynamics of DIC, DOC, and POC over an entire year, using a high resolution dataset. This research was performed in the catchment of the Schwabach River, a small, karstic headwater stream in Germany. The DIC data indicated the dominance of mineral weathering as a DIC source, with a dilution effect during high flow periods. A weakly negative relationship between discharge and d13CDIC indicates an increase in plant-derived organic matter during floods, transported to river waters via overland runoff and intermediate flow. DOC inputs were enhanced during periods of high discharge, indicating a greater importance of overland runoff as a DOC source. POC concentrations seem unaffected by discharge, but a slight negative correlation between d13CPOC and discharge may be derived from increased C4 plant material inputs. CO2 concentrations exceeded ambient atmospheric values throughout the year, confirming that the river surface waters are a net CO2 source. The total riverine carbon flux was dominated by DIC (70%), followed by CO2 efflux (21%), DOC (7%), and POC (2%). While a bi-monthly sampling scheme yielded a similar carbon flux estimate to that utilizing the entire dataset, the use of a monthly sampling interval differed by up to 19%. This discrepancy is due to the inability of a monthly sampling scheme to capture sudden and large variations in river discharge and associated dissolved/particulate carbon concentration changes, such as those observed during flooding. Bi-monthly sampling may be the minimum timeframe required for an acceptable degree of accuracy in carbon flux calculations. The application of high sampling frequencies and comprehensive DIC, DOC, and POC studies in future research would reduce uncertainties in riverine carbon budgets, and clarify the role of small streams in the global carbon cycle.
△ Less
Submitted 11 June, 2018; v1 submitted 8 June, 2018;
originally announced June 2018.
-
Machine learning classification for field distributions of photonic modes
Authors:
Carlo Barth,
Christiane Becker
Abstract:
Machine learning techniques can reveal hidden structure in large data amounts and can potentially extent or even replace analytical scientific methods. In nanophotonics, modes can increase the light yield from emitters located inside the nanostructure or near the surface. Optimizing such systems enforces to systematically analyze large amounts of three-dimensional field distribution data. We prese…
▽ More
Machine learning techniques can reveal hidden structure in large data amounts and can potentially extent or even replace analytical scientific methods. In nanophotonics, modes can increase the light yield from emitters located inside the nanostructure or near the surface. Optimizing such systems enforces to systematically analyze large amounts of three-dimensional field distribution data. We present a method based on finite element simulations and machine learning for the identification of modes with large field energies and specific spatial properties. By clustering we reduce the field distribution data to a minimal subset of prototypes. The predictive power of the approach is demonstrated using an analysis of experimentally measured fluorescence enhancement of quantum dots on a photonic crystal surface. The clustering method can be used for any optimization task that depends on three-dimensional field data, and is therefore relevant for biosensing, quantum dot solar cells or photon upconversion.
△ Less
Submitted 22 March, 2018;
originally announced March 2018.
-
Increased Fluorescence of PbS Quantum Dots in Photonic Crystals by Excitation Enhancement
Authors:
C. Barth,
S. Roder,
D. Brodoceanu,
T. Kraus,
M. Hammerschmidt,
S. Burger,
C. Becker
Abstract:
We report on enhanced fluorescence of lead sulfide quantum dots interacting with leaky modes of slab-type silicon photonic crystals. The photonic crystal slabs were fabricated supporting leaky modes in the near infrared wavelength range. Lead sulfite quantum dots which are resonant the same spectral range were prepared in a thin layer above the slab. We selectively excited the leaky modes by tunin…
▽ More
We report on enhanced fluorescence of lead sulfide quantum dots interacting with leaky modes of slab-type silicon photonic crystals. The photonic crystal slabs were fabricated supporting leaky modes in the near infrared wavelength range. Lead sulfite quantum dots which are resonant the same spectral range were prepared in a thin layer above the slab. We selectively excited the leaky modes by tuning wavelength and angle of incidence of the laser source and measured distinct resonances of enhanced fluorescence. By an appropriate experiment design, we ruled out directional light extraction effects and determined the impact of enhanced excitation. Three-dimensional numerical simulations consistently explain the experimental findings by strong near-field enhancements in the vicinity of the photonic crystal surface. Our study provides a basis for systematic tailoring of photonic crystals used in biological applications such as biosensing and single molecule detection, as well as quantum dot solar cells and spectral conversion applications.
△ Less
Submitted 22 August, 2017;
originally announced August 2017.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC
Authors:
C. Barth,
C. A. Betancourt,
I. Bloch,
F. Bögelspacher,
W. de Boer,
M. Daniels,
A. Dierlamm,
R. Eber,
G. Eckerlin,
D. Eckstein,
T. Eichhorn,
J. Erfle,
L. Feld,
E. Garutti,
I. -M. Gregor,
M. Guthoff,
F. Hartmann,
M. Hauser,
U. Husemann,
K. Jakobs,
A. Junkes,
W. Karpinski,
K. Klein,
S. Kuehn,
H. Lacker
, et al. (16 additional authors not shown)
Abstract:
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an env…
▽ More
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an environment in which both the hit densities and the radiation damage will be about an order of magnitude higher than today. In addition, the new trackers need to contribute to the first level trigger in order to maintain a high data-taking efficiency for the interesting processes. Novel detector technologies have to be developed to meet these very challenging goals. The German groups active in the upgrades of the ATLAS and CMS tracking systems have formed a collaborative "Project on Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC" (PETTL), which was supported by the Helmholtz Alliance "Physics at the Terascale" during the years 2013 and 2014. The aim of the project was to share experience and to work together on key areas of mutual interest during the R&D phase of these upgrades. The project concentrated on five areas, namely exchange of experience, radiation hardness of silicon sensors, low mass system design, automated precision assembly procedures, and irradiations. This report summarizes the main achievements.
△ Less
Submitted 28 April, 2016;
originally announced April 2016.
-
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.