Single-Shot Quantitative X-ray Imaging Using a Primary Modulator and Dual-Layer Detector
Authors:
Linxi Shi,
N. Robert Bennett,
Alexander Vezeridis,
Nishita Kothary,
Adam Wang
Abstract:
Purpose: Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free dual-energy (DE) imaging with scatter correction in a sing…
▽ More
Purpose: Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free dual-energy (DE) imaging with scatter correction in a single shot.
Methods: The SSQI algorithm allows simultaneous recovery of two material-specific images and two scatter images using four sub-measurements from the PM encoding. For validation, we set up SSQI on our tabletop system and imaged acrylic and copper slabs with known thicknesses, estimated scatter with our SSQI algorithm, and compared the material decomposition (MD) for different combinations of the two materials with ground truth. Second, we imaged an anthropomorphic chest phantom containing contrast in the coronary arteries and compared the MD with and without SSQI. Lastly, to evaluate SSQI in dynamic applications, we constructed a flow phantom that enabled dynamic imaging of iodine contrast.
Results: The root mean squared error (RMSE) of SSQI estimation was 0.13 cm for acrylic and 0.04 mm for copper. For the anthropomorphic phantom, direct MD resulted in incorrect interpretation of contrast and soft tissue, while SSQI successfully distinguished them and reduced RMSE in material-specific images by 38% to 92%. For the flow phantom, SSQI was able to perform accurate dynamic quantitative imaging, separating contrast from the background.
Conclusions: We demonstrated the potential of SSQI for robust quantitative x-ray imaging. The simplicity of SSQI may enable its widespread adoption, including radiography and dynamic imaging such as real-time image guidance and cone-beam CT.
△ Less
Submitted 27 September, 2022;
originally announced September 2022.
-
An Analysis of Scatter Characteristics in X-ray CT Spectral Correction
Authors:
Tao Zhang,
Zhiqiang Chen,
Hao Zhou,
N. Robert Bennett,
Adam S. Wang,
Hewei Gao
Abstract:
X-ray scatter remains a major physics challenge in volumetric computed tomography (CT), whose physical and statistical behaviors have been commonly leveraged in order to eliminate its impact on CT image quality. In this work, we conduct an in-depth derivation of how the scatter distribution and scatter to primary ratio (SPR) will change during the spectral correction, leading to an interesting fin…
▽ More
X-ray scatter remains a major physics challenge in volumetric computed tomography (CT), whose physical and statistical behaviors have been commonly leveraged in order to eliminate its impact on CT image quality. In this work, we conduct an in-depth derivation of how the scatter distribution and scatter to primary ratio (SPR) will change during the spectral correction, leading to an interesting finding on the property of scatter: when applying the spectral correction before scatter is removed, the impact of SPR on a CT projection will be scaled by the first derivative of the mapping function; while the scatter distribution in the transmission domain will be scaled by the product of the first derivative of the mapping function and a natural exponential of the projection difference before and after the mapping. Such a characterization of scatter's behavior provides an analytic approach of compensating for the SPR as well as approximating the change of scatter distribution after spectral correction, even though both of them might be significantly distorted as the linearization mapping function in spectral correction could vary a lot from one detector pixel to another. We conduct an evaluation of SPR compensations on a Catphan phantom and an anthropomorphic chest phantom to validate the characteristics of scatter. In addition, this scatter property is also directly adopted into CT imaging using a spectral modulator with flying focal spot technology (SMFFS) as an example to demonstrate its potential in practical applications.
△ Less
Submitted 30 December, 2020;
originally announced December 2020.
-
Deep Learning-Based Reconstruction of Interventional Tools from Four X-Ray Projections for Tomographic Interventional Guidance
Authors:
Elias Eulig,
Joscha Maier,
Michael Knaup,
N. Robert Bennett,
Klaus Hörndler,
Adam S. Wang,
Marc Kachelrieß
Abstract:
Image guidance for minimally invasive interventions is usually performed by acquiring fluoroscopic images using a C-arm system. However, the projective data provide only limited information about the spatial structure and position of interventional tools such as stents, guide wires or coils. In this work we propose a deep learning-based pipeline for real-time tomographic (four-dimensional) interve…
▽ More
Image guidance for minimally invasive interventions is usually performed by acquiring fluoroscopic images using a C-arm system. However, the projective data provide only limited information about the spatial structure and position of interventional tools such as stents, guide wires or coils. In this work we propose a deep learning-based pipeline for real-time tomographic (four-dimensional) interventional guidance at acceptable dose levels. In the first step, interventional tools are extracted from four cone-beam CT projections using a deep convolutional neural network (CNN). These projections are then reconstructed and fed into a second CNN, which maps this highly undersampled reconstruction to a segmentation of the interventional tools. Our pipeline is capable of reconstructing interventional tools from only four x-ray projections without the need for a patient prior with very high accuracy. Therefore, the proposed approach is capable of overcoming the drawbacks of today's interventional guidance and could enable the development of new minimally invasive radiological interventions by providing full spatiotemporal information about the interventional tools.
△ Less
Submitted 24 November, 2021; v1 submitted 23 September, 2020;
originally announced September 2020.