-
New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver
Authors:
HAYSTAC Collaboration,
M. J. Jewell,
A. F. Leder,
K. M. Backes,
Xiran Bai,
K. van Bibber,
B. M. Brubaker,
S. B. Cahn,
A. Droster,
Maryam H. Esmat,
Sumita Ghosh,
Eleanor Graham,
Gene C. Hilton,
H. Jackson,
Claire Laffan,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
E. P. Ruddy,
M. Simanovskaia,
Sukhman Singh
, et al. (4 additional authors not shown)
Abstract:
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgr…
▽ More
A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.
△ Less
Submitted 26 January, 2023; v1 submitted 23 January, 2023;
originally announced January 2023.
-
Experimental constraint on axion-like particle coupling over seven orders of magnitude in mass
Authors:
Tanya S. Roussy,
Daniel A. Palken,
William B. Cairncross,
Benjamin M. Brubaker,
Daniel N. Gresh,
Matt Grau,
Kevin C. Cossel,
Kia Boon Ng,
Yuval Shagam,
Yan Zhou,
Victor V. Flambaum,
Konrad W. Lehnert,
Jun Ye,
Eric A. Cornell
Abstract:
We use our recent electric dipole moment (EDM) measurement data to constrain the possibility that the HfF$^+$ EDM oscillates in time due to interactions with candidate dark matter axion-like particles (ALPs). We employ a Bayesian analysis method which accounts for both the look-elsewhere effect and the uncertainties associated with stochastic density fluctuations in the ALP field. We find no evide…
▽ More
We use our recent electric dipole moment (EDM) measurement data to constrain the possibility that the HfF$^+$ EDM oscillates in time due to interactions with candidate dark matter axion-like particles (ALPs). We employ a Bayesian analysis method which accounts for both the look-elsewhere effect and the uncertainties associated with stochastic density fluctuations in the ALP field. We find no evidence of an oscillating EDM over a range spanning from 27 nHz to 400 mHz, and we use this result to constrain the ALP-gluon coupling over the mass range $10^{-22}-10^{-15}$ eV. This is the first laboratory constraint on the ALP-gluon coupling in the $10^{-17}-10^{-15}$ eV range, and the first laboratory constraint to properly account for the stochastic nature of the ALP field.
△ Less
Submitted 18 March, 2021; v1 submitted 28 June, 2020;
originally announced June 2020.
-
An improved analysis framework for axion dark matter searches
Authors:
D. A. Palken,
B. M. Brubaker,
M. Malnou,
S. Al Kenany,
K. M. Backes,
S. B. Cahn,
Y. V. Gurevich,
S. K. Lamoreaux,
S. M. Lewis,
R. H. Maruyama,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
Sukhman Singh,
D. H. Speller,
I. Urdinaran,
K. van Bibber,
L. Zhong,
K. W. Lehnert
Abstract:
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis f…
▽ More
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
△ Less
Submitted 28 July, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.
-
Results from phase 1 of the HAYSTAC microwave cavity axion experiment
Authors:
L. Zhong,
S. Al Kenany,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
D. H. Speller,
I. Urdinaran,
K. A. van Bibber
Abstract:
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range…
▽ More
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
First results from the HAYSTAC axion search
Authors:
Benjamin M. Brubaker
Abstract:
The axion is a well-motivated cold dark matter (CDM) candidate first postulated to explain the absence of $CP$ violation in the strong interactions. CDM axions may be detected via their resonant conversion into photons in a "haloscope" detector: a tunable high-$Q$ microwave cavity maintained at cryogenic temperature, immersed a strong magnetic field, and coupled to a low-noise receiver.
This dis…
▽ More
The axion is a well-motivated cold dark matter (CDM) candidate first postulated to explain the absence of $CP$ violation in the strong interactions. CDM axions may be detected via their resonant conversion into photons in a "haloscope" detector: a tunable high-$Q$ microwave cavity maintained at cryogenic temperature, immersed a strong magnetic field, and coupled to a low-noise receiver.
This dissertation reports on the design, commissioning, and first operation of the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a new detector designed to search for CDM axions with masses above $20$ $μ\mathrm{eV}$. I also describe the analysis procedure developed to derive limits on axion CDM from the first HAYSTAC data run, which excluded axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}$ $\mathrm{GeV}^{-1}$, a factor of 2.3 above the benchmark KSVZ model, over the mass range $23.55 < m_a < 24.0$ $μ\mathrm{eV}$.
This result represents two important achievements. First, it demonstrates cosmologically relevant sensitivity an order of magnitude higher in mass than any existing direct limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, HAYSTAC has demonstrated total noise approaching the standard quantum limit for the first time in a haloscope axion search.
△ Less
Submitted 2 January, 2018;
originally announced January 2018.
-
Harnessing electro-optic correlations in an efficient mechanical converter
Authors:
A. P. Higginbotham,
P. S. Burns,
M. D. Urmey,
R. W. Peterson,
N. S. Kampel,
B. M. Brubaker,
G. Smith,
K. W. Lehnert,
C. A. Regal
Abstract:
An optical network of superconducting quantum bits (qubits) is an appealing platform for quantum communication and distributed quantum computing, but developing a quantum-compatible link between the microwave and optical domains remains an outstanding challenge. Operating at $T < 100$ mK temperatures, as required for quantum electrical circuits, we demonstrate a mechanically-mediated microwave-opt…
▽ More
An optical network of superconducting quantum bits (qubits) is an appealing platform for quantum communication and distributed quantum computing, but developing a quantum-compatible link between the microwave and optical domains remains an outstanding challenge. Operating at $T < 100$ mK temperatures, as required for quantum electrical circuits, we demonstrate a mechanically-mediated microwave-optical converter with 47$\%$ conversion efficiency, and use a feedforward protocol to reduce added noise to 38 photons. The feedforward protocol harnesses our discovery that noise emitted from the two converter output ports is strongly correlated because both outputs record thermal motion of the same mechanical mode. We also discuss a quantum feedforward protocol that, given high system efficiencies, allows quantum information to be transferred even when thermal phonons enter the mechanical element faster than the electro-optic conversion rate.
△ Less
Submitted 17 September, 2019; v1 submitted 18 December, 2017;
originally announced December 2017.
-
Recent Technical Improvements to the HAYSTAC Experiment
Authors:
L. Zhong,
B. M. Brubaker,
S. B. Cahn,
S. K. Lamoreaux
Abstract:
We report here several technical improvements to the HAYSTAC (Haloscope at Yale Sensitive To Axion Cold dark matter) that have improved operational efficiency, sensitivity, and stability.
We report here several technical improvements to the HAYSTAC (Haloscope at Yale Sensitive To Axion Cold dark matter) that have improved operational efficiency, sensitivity, and stability.
△ Less
Submitted 7 August, 2017; v1 submitted 12 June, 2017;
originally announced June 2017.
-
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Authors:
S. Al Kenany,
M. A. Anil,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
I. Urdinaran,
K. A. van Bibber,
L. Zhong
Abstract:
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple…
▽ More
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
△ Less
Submitted 22 February, 2017; v1 submitted 21 November, 2016;
originally announced November 2016.