-
A theoretical framework for multi-physics modeling of poro-visco-hyperelasticity-induced time-dependent fracture of blood clots
Authors:
Dongxu Liu,
Nhung Nguyen,
Tinh Quoc Bui,
Luka Pocivavsek
Abstract:
Fracture resistance of blood clots plays a crucial role in physiological hemostasis and pathological thromboembolism. Although recent experimental and computational studies uncovered the poro-viscoelastic property of blood clots and its connection to the time-dependent deformation behavior, the effect of these time-dependent processes on clot fracture and the underlying time-dependent fracture mec…
▽ More
Fracture resistance of blood clots plays a crucial role in physiological hemostasis and pathological thromboembolism. Although recent experimental and computational studies uncovered the poro-viscoelastic property of blood clots and its connection to the time-dependent deformation behavior, the effect of these time-dependent processes on clot fracture and the underlying time-dependent fracture mechanisms are not well understood. This work aims to formulate a thermodynamically consistent, multi-physics theoretical framework for describing the time-dependent deformation and fracture of blood clots. This theory concurrently couples fluid transport through porous fibrin networks, non-linear visco-hyperelastic deformation of the solid skeleton, solid/fluid interactions, mechanical degradation of tissues, gradient enhancement of energy, and protein unfolding of fibrin molecules. The constitutive relations of tissue constituents and the governing equation of fluid transport are derived within the framework of porous media theory by extending non-linear continuum thermodynamics at large strains. A physics-based, compressible network model is developed for the fibrin network of blood clots to describe its mechanical response. An energy-based damage model is developed to predict the damage and fracture of blood clots, and a transient non-local characterization length function is proposed to limit the damage zone bandwidth. The proposed model is experimentally validated using single-edge cracked clot specimens with different constituents. The fracture of blood clots subject to different loading conditions is simulated, and the mechanisms of clot fracture are systematically analyzed. Computational results show that the viscoelasticity and fluid transport play essential roles in the fracture of blood clots under physiological loading.
△ Less
Submitted 25 June, 2024; v1 submitted 27 May, 2024;
originally announced June 2024.
-
Temperature-dependent magnetic particle imaging with multi-harmonic lock-in detection
Authors:
Thinh Q. Bui,
Mark-Alexander Henn,
Weston L. Tew,
Megan A. Catterton,
Solomon I. Woods
Abstract:
Advances in instrumentation and tracer materials are still required to enable sensitive and accurate 3D temperature monitoring by magnetic particle imaging. We have developed a magnetic particle imaging instrument to observe temperature variations using MPI, and discuss resolution dependence on temperature and harmonic number. Furthermore, we present a low noise approach using lock-in detection fo…
▽ More
Advances in instrumentation and tracer materials are still required to enable sensitive and accurate 3D temperature monitoring by magnetic particle imaging. We have developed a magnetic particle imaging instrument to observe temperature variations using MPI, and discuss resolution dependence on temperature and harmonic number. Furthermore, we present a low noise approach using lock-in detection for temperature measurement, and discuss implications for a new detection modality of MPI.
△ Less
Submitted 20 January, 2023;
originally announced January 2023.
-
Comb-resolved spectroscopy with immersion grating in long-wave infrared
Authors:
Kana Iwakuni,
Thinh Q. Bui,
Justin Niedermeyer,
Takashi Sukegawa,
Jun Ye
Abstract:
We have developed a dispersive spectrometer using a compact immersion grating for direct frequency comb spectroscopy in the long-wave infrared region of 8-10 μm. A frequency resolution of 463 MHz is achieved, which is the highest reported in this wavelength region with a dispersive direct frequency comb spectrometer. We also demonstrate individual mode-resolved imaging of the frequency comb spectr…
▽ More
We have developed a dispersive spectrometer using a compact immersion grating for direct frequency comb spectroscopy in the long-wave infrared region of 8-10 μm. A frequency resolution of 463 MHz is achieved, which is the highest reported in this wavelength region with a dispersive direct frequency comb spectrometer. We also demonstrate individual mode-resolved imaging of the frequency comb spectrum by Vernier cavity filtering and apply this to obtain both simple and complex molecular spectra. These results indicate that the immersion grating spectrometer offers the next advancement for sensitive, high-resolution spectroscopy of transient and large/complex molecules when combined with cavity enhancement and cooling techniques.
△ Less
Submitted 1 November, 2018;
originally announced November 2018.
-
Spectral analyses of trans- and cis-DOCO transients via comb spectroscopy
Authors:
Thinh Q. Bui,
P. Bryan Changala,
Bryce J. Bjork,
Qi Yu,
Yimin Wang,
John F. Stanton,
Joel Bowman,
Jun Ye
Abstract:
We use time-resolved direct frequency comb spectroscopy in the mid-infrared to obtain high-resolution rovibrational spectra of products produced from the OD+CO reaction. In this work, we present spectral analyses for isotopologues of the transient DOCO radicals from this reaction in the OD stretch region. The analyses were performed with aid of two different theoretical approaches based on both pe…
▽ More
We use time-resolved direct frequency comb spectroscopy in the mid-infrared to obtain high-resolution rovibrational spectra of products produced from the OD+CO reaction. In this work, we present spectral analyses for isotopologues of the transient DOCO radicals from this reaction in the OD stretch region. The analyses were performed with aid of two different theoretical approaches based on both perturbation theory and variational calculations used for prediction of rovibrational spectra of polyatomic molecules. We discuss the advantages and challenges of our current approach for studying spectroscopy and dynamics of transient molecules.
△ Less
Submitted 19 March, 2018;
originally announced March 2018.
-
Phase-stabilized 100 mW frequency comb near 10 μm
Authors:
Kana Iwakuni,
Gil Porat,
Thinh Q. Bui,
Bryce J. Bjork,
Stephen B. Schoun,
Oliver H. Heckl,
Martin E. Fermann,
Jun Ye
Abstract:
Long-wavelength mid-infrared frequency combs with high power and flexible tunability are highly desired for molecular spectroscopy, including investigation of large molecules such as C60. We present a high power, phase-stabilized frequency comb near 10 μm, generated by a synchronously-pumped, singly-resonant optical parametric oscillator (OPO) based on AgGaSe2. The OPO can be continuously tuned fr…
▽ More
Long-wavelength mid-infrared frequency combs with high power and flexible tunability are highly desired for molecular spectroscopy, including investigation of large molecules such as C60. We present a high power, phase-stabilized frequency comb near 10 μm, generated by a synchronously-pumped, singly-resonant optical parametric oscillator (OPO) based on AgGaSe2. The OPO can be continuously tuned from 8.4 to 9.5 μm, with a maximum average idler power of 100 mW at the center wavelength of 8.5 μm. Both the repetition rate (frep) and the carrier-envelop offset frequency (fceo) of the idler wave are phase-locked to microwave signals referenced to a Cs clock. We describe the detailed design and construction of the frequency comb, and discuss potential applications for precise and sensitive direct frequency comb spectroscopy.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
Direct measurements of DOCO isomers in the kinetics of OD+CO
Authors:
Thinh Q. Bui,
Bryce J. Bjork,
P. Bryan Changala,
Thanh L. Nguyen,
John F. Stanton,
Mitchio Okumura,
Jun Ye
Abstract:
Quantitative and mechanistically-detailed kinetics of the reaction of hydroxyl radical (OH) with carbon monoxide (CO) have been a longstanding goal of contemporary chemical kinetics. This fundamental prototype reaction plays an important role in atmospheric and combustion chemistry, motivating studies for accurate determination of the reaction rate coefficient and its pressure and temperature depe…
▽ More
Quantitative and mechanistically-detailed kinetics of the reaction of hydroxyl radical (OH) with carbon monoxide (CO) have been a longstanding goal of contemporary chemical kinetics. This fundamental prototype reaction plays an important role in atmospheric and combustion chemistry, motivating studies for accurate determination of the reaction rate coefficient and its pressure and temperature dependence at thermal reaction conditions. This intricate dependence can be traced directly to details of the underlying dynamics (formation, isomerization, and dissociation) involving the reactive intermediates cis- and trans-HOCO, which can only be observed transiently. Using time-resolved frequency comb spectroscopy, comprehensive mechanistic elucidation of the kinetics of the isotopic analogue deuteroxyl radical (OD) with CO has been realized. By monitoring the concentrations of reactants, intermediates, and products in real-time, the branching and isomerization kinetics and absolute yields of all species in the OD+CO reaction are quantified as a function of pressure and collision partner.
△ Less
Submitted 6 October, 2017; v1 submitted 14 June, 2017;
originally announced June 2017.
-
OD + CO -> D + CO2 Branching Kinetics Probed with Time-Resolved Frequency Comb Spectroscopy
Authors:
Thinh Q. Bui,
Bryce J. Bjork,
P. Bryan Changala,
Oliver H. Heckl,
Ben Spaun,
Jun Ye
Abstract:
Time-resolved direct frequency comb spectroscopy (TRFCS) was used to study the kinetics of the deuterated analogue of the OH+CO->H+CO2 reaction, which is important for atmospheric and combustion chemistry. Complementing our recent work on quantifying the formation rate of the transient trans-DOCO radical, we report measurements of the kinetics of the activated product channel, D+CO2, at room tempe…
▽ More
Time-resolved direct frequency comb spectroscopy (TRFCS) was used to study the kinetics of the deuterated analogue of the OH+CO->H+CO2 reaction, which is important for atmospheric and combustion chemistry. Complementing our recent work on quantifying the formation rate of the transient trans-DOCO radical, we report measurements of the kinetics of the activated product channel, D+CO2, at room temperature. Simultaneous measurements of the time-dependence of OD and CO2 concentrations allowed us to directly determine the formation rate, branching yield, and dependence on pressure and bath gas of the activated product. Together with the trans-DOCO formation rate, these new measurements provide absolute yields of branching channels for both products of OD+CO in the low-pressure limit.
△ Less
Submitted 3 January, 2017;
originally announced January 2017.
-
Three Photon Absorption in Optical Parametric Oscillators Based on OP-GaAs
Authors:
Oliver H. Heckl,
Bryce J. Bjork,
Georg Winkler,
P. Bryan Changala,
Ben Spaun,
1 Gil Porat,
Thinh Q. Bui,
Kevin F. Lee,
Jie Jiang,
Martin Fermann,
Peter G. Schunemann,
Jun Ye
Abstract:
We report on the first singly-resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 $μ$m within ~3 dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synch…
▽ More
We report on the first singly-resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 $μ$m within ~3 dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synchronously pumped OPO based on OP-GaAs. We discovered strong three photon absorption with a coefficient of 0.35 ${\pm}$ 0.06 cm${^3}$/GW${^2}$ for our OP-GaAs sample, which limits the output power of these OPOs as mid-IR light sources. We present a detailed study of the three photon loss on the performance of both the SR and DR-OPOs, and compare them to those without this loss mechanism.
△ Less
Submitted 2 September, 2016;
originally announced September 2016.
-
Direct Frequency Comb Measurement of OD + CO -> DOCO Kinetics
Authors:
Bryce J. Bjork,
Thinh Q. Bui,
Oliver H. Heckl,
P. Bryan Changala,
Ben Spaun,
Paula Heu,
David Follman,
Christoph Deutsch,
Garrett D. Cole,
Markus Aspelmeyer,
Mitchio Okumura,
Jun Ye
Abstract:
The kinetics of the OH + CO reaction, fundamental to both atmospheric and combustion chemistry, are complex due to the formation of the HOCO intermediate. Despite extensive studies on this reaction, HOCO has not been observed at thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we…
▽ More
The kinetics of the OH + CO reaction, fundamental to both atmospheric and combustion chemistry, are complex due to the formation of the HOCO intermediate. Despite extensive studies on this reaction, HOCO has not been observed at thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we observe OD + CO reaction kinetics with the detection of stabilized trans-DOCO, the deuterated analogue of trans-HOCO, and its yield. By simultaneously measuring the time-dependent concentrations of both trans-DOCO and OD species, we observe unambiguous low-pressure termolecular dependence on the reaction rate coefficients for both N2 and CO bath gases. These results confirm the HOCO formation mechanism and quantify its yield.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.