Showing 1–6 of 6 results for author: Butler, A P

Searching in archive physics. Search in all archives.
.
  1. MARS-MD: rejection based image domain material decomposition

    Authors: C. J. Bateman, D. Knight, B. Brandwacht, J. Mc Mahon, J. Healy, R. Panta, R. Aamir, K. Rajendran, M. Moghiseh, M. Ramyar, D. Rundle, J. Bennett, N. de Ruiter, D. Smithies, S. T. Bell, R. Doesburg, A. Chernoglazov, V. B. H. Mandalika, M. Walsh, M. Shamshad, M. Anjomrouz, A. Atharifard, L. Vanden Broeke, S. Bheesette, T. Kirkbride , et al. (6 additional authors not shown)

    Abstract: This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problem… ▽ More

    Submitted 14 February, 2018; originally announced February 2018.

  2. arXiv:1506.04223  [pdf, other

    physics.med-ph

    The Hidden K-edge Signal in K-edge Imaging

    Authors: Christopher J. Bateman, Kishore Rajendran, Niels J. A. de Ruiter, Anthony P. Butler, Philip H. Butler, Peter F. Renaud

    Abstract: K-edge imaging is commonly used for viewing contrast pharmaceuticals in a variety of multi-energy x-ray imaging techniques, ranging from dual-energy and spectral computed tomography to fluoroscopy. When looking for the K-edge signal of a specific contrast, by taking measurements either side of the K-edge, it is found that the K-edge is not always observable for low concentrations. We have also obs… ▽ More

    Submitted 13 June, 2015; originally announced June 2015.

    Comments: Keywords: computed tomography, spectral, multi-energy, dual-energy, K-edge imaging, material decomposition, Medipix

  3. arXiv:1501.07852  [pdf, other

    physics.ins-det

    Alignment and resolution studies of a MARS scanner

    Authors: A. P. Butler, P. H. Butler, S. T. Bell, G. Chelkov, M. Demichev, A. Gongadze, S. Kotov, D. Kozhevnikov, U. Kruchonak, I. Potrap, P. Smolyanskiy, A. Zhemchugov

    Abstract: The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise… ▽ More

    Submitted 23 March, 2015; v1 submitted 29 January, 2015; originally announced January 2015.

  4. Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip

    Authors: A. P. Butler, P. H. Butler, S. T. Bell, G. A. Chelkov, D. V. Dedovich, M. A. Demichev, V. G. Elkin, M. I. Gostkin, S. A. Kotov, D. A. Kozhevnikov, U. G. Kruchonak, A. A. Nozdrin, S. Yu. Porokhovoy, I. N. Potrap, P. I. Smolyanskiy, M. M. Zakhvatkin, A. S. Zhemchugov

    Abstract: This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with the resolution and the efficiency of the pixel detector is used for the calibration. The energy resolution of the detector is also measured during the calibratio… ▽ More

    Submitted 14 January, 2015; originally announced January 2015.

  5. arXiv:1311.5303  [pdf, other

    physics.med-ph physics.ins-det

    Reducing beam hardening effects and metal artefacts using Medipix3RX: With applications from biomaterial science

    Authors: K. Rajendran, M. F. Walsh, N. J. A. de Ruiter, A. I. Chernoglazov, R. K. Panta, A. P. H. Butler, P. H. Butler, S. T. Bell, N. G. Anderson, T. B. F. Woodfield, S. J. Tredinnick, J. L. Healy, C. J. Bateman, R. Aamir, R. M. N. Doesburg, P. F. Renaud, S. P. Gieseg, D. J. Smithies, J. L. Mohr, V. B. H. Mandalika, A. M. T. Opie, N. J. Cook, J. P. Ronaldson, S. J. Nik, A. Atharifard , et al. (6 additional authors not shown)

    Abstract: This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routi… ▽ More

    Submitted 20 November, 2013; originally announced November 2013.

  6. MARS spectral molecular imaging of lamb tissue: data collection and image analysis

    Authors: R Aamir, A Chernoglazov, C J Bateman, A P H Butler, P H Butler, N G Anderson, S T Bell, R K Panta, J L Healy, J L Mohr, K Rajendran, M F Walsh, N de Ruiter, S P Gieseg, T Woodfield, P F Renaud, L Brooke, S Abdul-Majid, M Clyne, R Glendenning, P J Bones, M Billinghurst, C Bartneck, H Mandalika, R Grasset , et al. (13 additional authors not shown)

    Abstract: Spectral molecular imaging is a new imaging technique able to discriminate and quantify different components of tissue simultaneously at high spatial and high energy resolution. Our MARS scanner is an x-ray based small animal CT system designed to be used in the diagnostic energy range (20 to 140 keV). In this paper, we demonstrate the use of the MARS scanner, equipped with the Medipix3RX spectros… ▽ More

    Submitted 23 January, 2014; v1 submitted 18 November, 2013; originally announced November 2013.

    Comments: 11 pages, 6 figs