Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
Authors:
CRAB Collaboration,
NUCLEUS Collaboration,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
I. Colantoni,
J. -P. Crocombette,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Desforge,
A. Doblhammer,
E. Dumonteil,
S. Dorer,
A. Erhart,
A. Fuss,
M. Friedl,
A. Garai
, et al. (53 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact…
▽ More
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.
△ Less
Submitted 2 June, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
Calibration of nuclear recoils at the 100 eV scale using neutron capture
Authors:
L. Thulliez,
D. Lhuillier,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
E. Dumonteil,
A. Erhart,
A. Giuliani,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
A. Langenkämper,
T. Lasserre,
A. Letourneau,
O. Litaize,
P. de Marcillac,
S. Marnieros,
T. Materna,
B. Mauri,
E. Mazzucato,
C. Nones,
T. Ortmann
, et al. (12 additional authors not shown)
Abstract:
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear…
▽ More
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear recoil peaks in the 100 eV range. Using the FIFRELIN code, complete schemes of $γ$-cascades for various isotopes can be predicted with high accuracy to determine the continuous background of nuclear recoils below the calibration peaks. We present a comprehensive experimental concept for the calibration of CaWO$_4$ and Ge cryogenic detectors at a research reactor. For CaWO$_4$ the simulations show that two nuclear recoil peaks at 112.5 eV and 160.3 eV should be visible above background simply in the spectrum of the cryogenic detector. Then we discuss how the additional tagging for the associated $γ$ increases the sensitivity of the method and extends its application to a wider energy range and to Ge cryogenic detectors.
△ Less
Submitted 23 May, 2021; v1 submitted 27 November, 2020;
originally announced November 2020.