-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Radiation hardness of GaAs: Cr and Si sensors irradiated by electron beam
Authors:
U. Kruchonak,
S. Abou El-Azm,
K. Afanaciev,
G. Chelkov,
M. Demichev,
M. Gostkin,
A. Guskov,
E. Firu,
V. Kobets,
A. Leyva,
d,
A. Nozdrin,
S. Porokhovoy,
A. Sheremetyeva,
P. Smolyanskiy,
A. Torres,
A. Tyazhev,
O. Tolbanov,
N. Zamyatin,
A. Zarubin,
A. Zhemchugov
Abstract:
The interest in using the radiation detectors based on high resistive chromium-compensated GaAs (GaAs:Cr) in high energy physics and others applied fields has been growing steadily due to its numerous advantages over others classical materials. High radiation hardness at room temperature stands out and needs to be systematically investigated. In this paper an experimental study of the effect of 20…
▽ More
The interest in using the radiation detectors based on high resistive chromium-compensated GaAs (GaAs:Cr) in high energy physics and others applied fields has been growing steadily due to its numerous advantages over others classical materials. High radiation hardness at room temperature stands out and needs to be systematically investigated. In this paper an experimental study of the effect of 20.9 MeV electrons generated by the LINAC-200 accelerator on some properties of GaAs:Cr based sensors is presented. In parallel, Si sensors were irradiated at the same conditions, measured and analyzed in order to perform a comparative study. The target sensors were irradiated with the dose up to 1.5 MGy. The current-voltage characteristics, resistivity, charge collection efficiency and their dependences on the bias voltage and temperature were measured at different absorbed doses. An analysis of the possible microscopic mechanisms leading to the observed effects in GaAs:Cr sensors is presented in the article.
△ Less
Submitted 1 June, 2020;
originally announced June 2020.
-
Visualization of radiotracers for SPECT imaging using a Timepix detector with a coded aperture
Authors:
V. Rozhkov,
G. Chelkov,
I. Hernández,
O. Ivanov,
D. Kozhevniko,
A. Leyva,
A. Perera,
D. Rastorguev,
P. Smolyanskiy,
L. Torres,
A. Zhemchugov
Abstract:
The work shows the ability to visualize radiotracers used in SPECT with a system based on a coded aperture mask and a hybrid pixel Timepix detector with the CdTe sensor. Characterization of the system using X-rays and radioactive sources confirms that the spatial resolution of less than 1 mm with a field of view 3 cm x 3 cm can be achieved. The results of a simulation study to determine the expect…
▽ More
The work shows the ability to visualize radiotracers used in SPECT with a system based on a coded aperture mask and a hybrid pixel Timepix detector with the CdTe sensor. Characterization of the system using X-rays and radioactive sources confirms that the spatial resolution of less than 1 mm with a field of view 3 cm x 3 cm can be achieved. The results of a simulation study to determine the expected spatial resolution of the system in the focal plane for the various radionuclides is presented. The possibility of using this system with a thin (1.5 mm) coded aperture mask for reconstructing images of gamma emitters with the energy up to 180 keV is demonstrated.
△ Less
Submitted 28 May, 2020; v1 submitted 20 April, 2020;
originally announced April 2020.
-
Properties of GaAs:Cr-based Timepix detectors
Authors:
P. Smolyanskiy,
G. Chelkov,
S. Kotov,
U. Kruchonak,
D. Kozhevnikov,
S. Pospisil,
I. Stekl,
A. Zhemchugov
Abstract:
It is the hybrid pixel detector technology which brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon as the most widespread detector material is marginally sensitive to photons with energy more than 30 keV. That's why the high-Z alternatives to silicon such as gallium arsenide and cadmium telluride are increasingly att…
▽ More
It is the hybrid pixel detector technology which brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon as the most widespread detector material is marginally sensitive to photons with energy more than 30 keV. That's why the high-Z alternatives to silicon such as gallium arsenide and cadmium telluride are increasingly attracting attention of the community for the development of X-ray imaging systems in recent years. We present in this work the results of our investigations of the Timepix detectors bump-bonded with sensors made of gallium arsenide compensated by chromium (GaAs:Cr). The properties which are mostly important from the practical point of view: IV characteristics, charge transport characteristics, operational stability, homogeneity, temperature dependence as well as energy and spatial resolution are considered. Applicability of these detectors for spectroscopic X-ray imaging is discussed.
△ Less
Submitted 9 December, 2017;
originally announced December 2017.
-
Response of Timepix detector with GaAs:Cr and Si sensor to heavy ions
Authors:
S. M. Abu Al Azm,
G. Chelkov,
D. Kozhevnikov,
A. Guskov,
A. Lapkin,
A. Leyva Fabelo,
P. Smolyanskiy,
A. Zhemchugov
Abstract:
The response of the Timepix detector to neon ions with kinetic energy 77 and 158.4 MeV has been studied at the cyclotron U-400M of the JINR Flerov Laboratory of Nuclear Reaction. Sensors produced from gallium arsenide compensated by chromium and from silicon are used for these measurements. While in Timepix detector with Si sensor the well-known so-called "volcano effect" observed, in Timepix dete…
▽ More
The response of the Timepix detector to neon ions with kinetic energy 77 and 158.4 MeV has been studied at the cyclotron U-400M of the JINR Flerov Laboratory of Nuclear Reaction. Sensors produced from gallium arsenide compensated by chromium and from silicon are used for these measurements. While in Timepix detector with Si sensor the well-known so-called "volcano effect" observed, in Timepix detector with GaAs:Cr sensor such effect was completely absent.
In the work the behavior of the Timepix detector with GaAs:Cr sensor under irradiation with heavy ions is described in comparison with the detector based on Si sensor. Also the possible reason for absence of "volcano" effect in GaAs:Cr detector is proposed.
△ Less
Submitted 10 June, 2017;
originally announced June 2017.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Luminosity measurements for the R scan experiment at BESIII
Authors:
M. Ablikim,
M. N. Achasov,
S. Ahmed,
X. C. Ai,
O. Albayrak,
M. Albrecht,
D. J. Ambrose,
A. Amoroso,
F. F. An,
Q. An,
J. Z. Bai,
O. Bakina,
R. Baldini Ferroli,
Y. Ban,
D. W. Bennett,
J. V. Bennett,
N. Berger,
M. Bertani,
D. Bettoni,
J. M. Bian,
F. Bianchi,
E. Boger,
I. Boyko,
R. A. Briere,
H. Cai
, et al. (405 additional authors not shown)
Abstract:
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Beijing Spectrometer (BESIII) at the Beijing Electron-Positron Collider (BEPCII), the integrated luminosities have been measur…
▽ More
By analyzing the large-angle Bhabha scattering events $e^{+}e^{-}$ $\to$ ($γ$)$e^{+}e^{-}$ and diphoton events $e^{+}e^{-}$ $\to$ $γγ$ for the data sets collected at center-of-mass (c.m.) energies between 2.2324 and 4.5900 GeV (131 energy points in total) with the upgraded Beijing Spectrometer (BESIII) at the Beijing Electron-Positron Collider (BEPCII), the integrated luminosities have been measured at the different c.m. energies, individually. The results are the important inputs for R value and $J/ψ$ resonance parameter measurements.
△ Less
Submitted 11 February, 2017;
originally announced February 2017.
-
Alignment and resolution studies of a MARS scanner
Authors:
A. P. Butler,
P. H. Butler,
S. T. Bell,
G. Chelkov,
M. Demichev,
A. Gongadze,
S. Kotov,
D. Kozhevnikov,
U. Kruchonak,
I. Potrap,
P. Smolyanskiy,
A. Zhemchugov
Abstract:
The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise…
▽ More
The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise knowledge of several geometrical parameters of a tomograph, such as displacement of a rotation axis, x-ray source position with respect to a camera, and camera inclinations. Use of inaccurate parameters leads to a poor sample reconstruction. Non-ideal positioning of camera, x-ray source and cylindrical rotating frame (gantry) itself on which these parts are located, leads to the need for tomograph alignment. In this note we describe the alignment procedure that was used to get different geometrical corrections for the reconstruction. Also, several different estimations of the final spatial resolution for reconstructed images are presented.
△ Less
Submitted 23 March, 2015; v1 submitted 29 January, 2015;
originally announced January 2015.
-
Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip
Authors:
A. P. Butler,
P. H. Butler,
S. T. Bell,
G. A. Chelkov,
D. V. Dedovich,
M. A. Demichev,
V. G. Elkin,
M. I. Gostkin,
S. A. Kotov,
D. A. Kozhevnikov,
U. G. Kruchonak,
A. A. Nozdrin,
S. Yu. Porokhovoy,
I. N. Potrap,
P. I. Smolyanskiy,
M. M. Zakhvatkin,
A. S. Zhemchugov
Abstract:
This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with the resolution and the efficiency of the pixel detector is used for the calibration. The energy resolution of the detector is also measured during the calibratio…
▽ More
This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with the resolution and the efficiency of the pixel detector is used for the calibration. The energy resolution of the detector is also measured during the calibration. The use of per-pixel calibration allows to achieve a good energy resolution of the Timepix detector with GaAs:Cr sensor: 8% and 13% at 60 keV and 20 keV, respectively.
△ Less
Submitted 14 January, 2015;
originally announced January 2015.
-
ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
D. Avila,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Bergholz,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
L. Dumitru,
K. Elsener,
V. Fadeyev,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
H. Henschel
, et al. (44 additional authors not shown)
Abstract:
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens…
▽ More
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
△ Less
Submitted 1 June, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Measurements of Baryon Pair Decays of $χ_{cJ}$ Mesons
Authors:
M. Ablikim,
M. N. Achasov,
O. Albayrak,
D. J. Ambrose,
F. F. An,
Q. An,
J. Z. Bai,
Y. Ban,
J. Becker,
J. V. Bennett,
M. Bertani,
J. M. Bian,
E. Boger,
O. Bondarenko,
I. Boyko,
R. A. Briere,
V. Bytev,
X. Cai,
O. Cakir,
A. Calcaterra,
G. F. Cao,
S. A. Cetin,
J. F. Chang,
G. Chelkov,
G. Chen
, et al. (326 additional authors not shown)
Abstract:
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$,…
▽ More
Using 106 $\times 10^{6}$ $ψ^{\prime}$ decays collected with the BESIII detector at the BEPCII, three decays of $χ_{cJ}$ ($J=0,1,2$) with baryon pairs ($\llb$, $\ssb$, $\SSB$) in the final state have been studied. The branching fractions are measured to be $\cal{B}$$(χ_{c0,1,2}\rightarrowΛ\barΛ) =(33.3 \pm 2.0 \pm 2.6)\times 10^{-5}$, $(12.2 \pm 1.1 \pm 1.1)\times 10^{-5}$, $(20.8 \pm 1.6 \pm 2.3)\times 10^{-5}$; $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{0}\barΣ^{0})$ = $(47.8 \pm 3.4 \pm 3.9)\times 10^{-5}$, $(3.8 \pm 1.0 \pm 0.5)\times 10^{-5}$, $(4.0 \pm 1.1 \pm 0.5) \times 10^{-5}$; and $\cal{B}$$(χ_{c0,1,2}\rightarrowΣ^{+}\barΣ^{-})$ = $(45.4 \pm 4.2 \pm 3.0)\times 10^{-5}$, $(5.4 \pm 1.5 \pm 0.5)\times 10^{-5}$, $(4.9 \pm 1.9 \pm 0.7)\times 10^{-5}$, where the first error is statistical and the second is systematic. Upper limits on the branching fractions for the decays of $χ_{c1,2}\rightarrowΣ^{0}\barΣ^{0}$, $Σ^{+}\barΣ^{-}$, are estimated to be $\cal{B}$$(χ_{c1}\rightarrowΣ^{0}\barΣ^{0}) < 6.2\times 10^{-5}$, $\cal{B}$$(χ_{c2}\rightarrowΣ^{0}\barΣ^{0}) < 6.5\times 10^{-5}$, $\cal{B}$$(χ_{c1}\rightarrowΣ^{+}\barΣ^{-}) < 8.7\times 10^{-5}$ and $\cal{B}$$(χ_{c2}\rightarrowΣ^{+}\barΣ^{-}) < 8.8\times 10^{-5}$ at the 90% confidence level.
△ Less
Submitted 4 March, 2013; v1 submitted 9 November, 2012;
originally announced November 2012.
-
Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.
-
Why the paper CERN-PH-EP-2009-015 (arXiv:0903.4762) is scientifically unacceptable
Authors:
The HARP-CDP group,
:,
A. Bolshakova,
I. Boyko,
G. Chelkov,
D. Dedovitch,
A. Elagin,
M. Gostkin,
A. Guskov,
Z. Kroumchtein,
Yu. Nefedov,
K. Nikolaev,
A. Zhemchugov,
F. Dydak,
J. Wotschack,
A. De Min,
V. Ammosov,
V. Gapienko,
V. Koreshev,
A. Semak,
Yu. Sviridov,
E. Usenko,
V. Zaets
Abstract:
The paper CERN-PH-EP-2009-015 (arXiv:0903.4762) by A. Bagulya et al. violates standards of quality of work and scientific ethics on several counts. The paper contains assertions that contradict established detector physics. The paper falls short of proving the correctness of the authors' concepts and results. The paper ignores or quotes misleadingly pertinent published work. The paper ignores th…
▽ More
The paper CERN-PH-EP-2009-015 (arXiv:0903.4762) by A. Bagulya et al. violates standards of quality of work and scientific ethics on several counts. The paper contains assertions that contradict established detector physics. The paper falls short of proving the correctness of the authors' concepts and results. The paper ignores or quotes misleadingly pertinent published work. The paper ignores the fact that the authors' concepts and results have already been shown wrong in the published literature. The authors seem unaware that cross-section results from the 'HARP Collaboration' that are based on the paper's concepts and algorithms are in gross disagreement with the results of a second analysis of the same data, and with the results of other experiments.
△ Less
Submitted 15 September, 2009;
originally announced September 2009.