-
A Semiclassical Framework for Mixed Quantum Classical Dynamics
Authors:
Shreyas Malpathak,
Matthew S. Church,
Nandini Ananth
Abstract:
Semiclassical approximations for quantum dynamic simulations in complex chemical systems range from rigorously accurate methods that are computationally expensive to methods that exhibit near-classical scaling with system size but are limited in their ability to describe quantum effects. In practical studies of high-dimensional reactions, neither extreme is the best choice: frequently a high-level…
▽ More
Semiclassical approximations for quantum dynamic simulations in complex chemical systems range from rigorously accurate methods that are computationally expensive to methods that exhibit near-classical scaling with system size but are limited in their ability to describe quantum effects. In practical studies of high-dimensional reactions, neither extreme is the best choice: frequently a high-level quantum mechanical description is only required for a handful of modes, while the majority of environment modes that do not play a key role in the reactive event of interest are well served with a lower level of theory. In this feature we introduce Modified Filinov filtration as a powerful tool for mixed quantum-classical simulations in a uniform semiclassical framework.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Semiclassical dynamics in the mixed quantum-classical limit
Authors:
Matthew S. Church,
Nandini Ananth
Abstract:
The semiclassical Double Herman-Kluk Initial Value Representation is an accurate approach to computing quantum real time correlation functions, but its applications are limited by the need to evaluate an oscillatory integral. In previous work, we have shown that this `sign problem' can be mitigated using the modified Filinov filtration technique to control the extent to which individual modes of t…
▽ More
The semiclassical Double Herman-Kluk Initial Value Representation is an accurate approach to computing quantum real time correlation functions, but its applications are limited by the need to evaluate an oscillatory integral. In previous work, we have shown that this `sign problem' can be mitigated using the modified Filinov filtration technique to control the extent to which individual modes of the system contribute to the overall phase of the integrand. Here we follow this idea to a logical conclusion: we analytically derive a general expression for the mixed quantum-classical limit of the semiclassical correlation function - AMQC-IVR, where the phase contributions from the `classical' modes of the system are filtered while the `quantum' modes are treated in the full semiclassical limit. We numerically demonstrate the accuracy and efficiency of the AMQC-IVR formulation in calculations of quantum correlation functions and reaction rates using three model systems with varied coupling strengths between the classical and quantum subsystems. We also introduce a separable prefactor approximation that further reduces the computational cost, but is only accurate in the limit of weak coupling between the quantum and classical subsystems.
△ Less
Submitted 29 June, 2019;
originally announced July 2019.
-
Nonadiabatic semiclassical dynamics in the mixed quantum-classical initial value representation
Authors:
Matthew S. Church,
Timothy J. H. Hele,
Gregory S. Ezra,
Nandini Ananth
Abstract:
We extend the Mixed Quantum-Classical Initial Value Representation (MQC-IVR), a semiclassical method for computing real-time correlation functions, to electronically nonadiabatic systems using the Meyer-Miller-Stock-Thoss (MMST) Hamiltonian to treat electronic and nuclear degrees of freedom (dofs) within a consistent dynamic framework. We introduce an efficient symplectic integration scheme, the M…
▽ More
We extend the Mixed Quantum-Classical Initial Value Representation (MQC-IVR), a semiclassical method for computing real-time correlation functions, to electronically nonadiabatic systems using the Meyer-Miller-Stock-Thoss (MMST) Hamiltonian to treat electronic and nuclear degrees of freedom (dofs) within a consistent dynamic framework. We introduce an efficient symplectic integration scheme, the MInt algorithm, for numerical time-evolution of the nuclear and electronic phase space variables as well as the Monodromy matrix, under the non-separable MMST Hamiltonian. We then calculate the probability of transmission through a curve-crossing in model two-level systems and show that in the quantum limit MQC-IVR is in good agreement with the exact quantum results, whereas in the classical limit the method yields results in keeping with mean-field approaches like the Linearized Semiclassical IVR. Finally, exploiting the ability of MQC-IVR to quantize different dofs to different extents, we present a detailed study of the extents to which quantizing the nuclear and electronic dofs improves numerical convergence properties without significant loss of accuracy.
△ Less
Submitted 21 September, 2017;
originally announced September 2017.
-
Validating and Implementing Modified Filinov Phase Filtration in Semiclassical Dynamics
Authors:
Matthew S. Church,
Sergey V. Antipov,
Nandini Ananth
Abstract:
The Mixed Quantum-Classical Initial Value Representation (MQC-IVR) is a recently introduced approximate semiclassical (SC) method for the calculation of real-time quantum correlation functions. MQC-IVR employs a modified Filinov filtration (MFF) scheme to control the overall phase of the SC integrand, extending the applicability of SC methods to complex systems while retaining their ability to acc…
▽ More
The Mixed Quantum-Classical Initial Value Representation (MQC-IVR) is a recently introduced approximate semiclassical (SC) method for the calculation of real-time quantum correlation functions. MQC-IVR employs a modified Filinov filtration (MFF) scheme to control the overall phase of the SC integrand, extending the applicability of SC methods to complex systems while retaining their ability to accurately describe quantum coherence effects. Here, we address questions regarding the effectiveness of the MFF scheme in combination with SC dynamics. Previous work showed that this filtering scheme is of limited utility in the context of semiclassical wavepacket propagation, but we find the MFF is extraordinarily powerful in the context of correlation functions. By examining trajectory phase and amplitude contributions to the real-time SC correlation function in a model system, we clearly demonstrate that the MFF serves to reduce noise by damping amplitude only in regions of highly oscillatory phase leading to a reduction in computational effort while retaining accuracy. Further, we introduce a novel and efficient MQC-IVR formulation that allows for linear scaling in computational cost with the total simulation length, a significant improvement over the more-than quadratic scaling exhibited by the original method.
△ Less
Submitted 18 May, 2017;
originally announced May 2017.
-
High Power Test Of A 3.9 GHz 5-cell Deflecting-mode Cavity In A Cryogenic Operation
Authors:
Young-Min Shin,
Michael Church
Abstract:
A 3.9 GHz deflecting mode (pi, TM110) cavity has been long used for six-dimensional phase-space beam manipulation tests at the A0 Photo-Injector Lab (16 MeV) in Fermilab and their extended applications with vacuum cryomodules are currently planned at the Advanced Superconducting Test Accelerator (ASTA) user facility (> 50 MeV). Despite the successful test results, the cavity, however, demonstrated…
▽ More
A 3.9 GHz deflecting mode (pi, TM110) cavity has been long used for six-dimensional phase-space beam manipulation tests at the A0 Photo-Injector Lab (16 MeV) in Fermilab and their extended applications with vacuum cryomodules are currently planned at the Advanced Superconducting Test Accelerator (ASTA) user facility (> 50 MeV). Despite the successful test results, the cavity, however, demonstrated limited RF performance during liquid nitrogen (LN2) ambient operation that was inferior to theoretical prediction. We have been performing full analysis of the designed cavity by analytic calculation and comprehensive system simulation analysis to solve complex thermodynamics and mechanical stresses. The re-assembled cryomodule is currently under the test with a 50 kW klystron at the Fermilab A0 beamline, which will benchmark the modeling analysis. The test result will be used to design vacuum cryomodules for the 3.9 GHz deflecting mode cavity that will be employed at the ASTA facility for beam diagnostics and phase-space control.
△ Less
Submitted 18 September, 2014;
originally announced September 2014.
-
Mitigation Plans for the Microbunching-Instability-Related COTR at ASTA/FNAL
Authors:
A. H. Lumpkin,
M. Church,
A. S. Johnson
Abstract:
At the Advanced Superconducting Test Accelerator (ASTA) now under construction at Fermilab, we anticipate the appearance of the microbunching instability related to the longitudinal space charge (LSC) impedances. With a photoinjector source and up to two chicane compressors planned, the conditions should result in the shift of some microbunched features into the visible light regime. The presence…
▽ More
At the Advanced Superconducting Test Accelerator (ASTA) now under construction at Fermilab, we anticipate the appearance of the microbunching instability related to the longitudinal space charge (LSC) impedances. With a photoinjector source and up to two chicane compressors planned, the conditions should result in the shift of some microbunched features into the visible light regime. The presence of longitudinal microstructures (microbunching) in the electron beam or the leading edge spikes can result in strong, spatially localized coherent enhancements of optical transition radiation (COTR) that mask the actual beam profile. Several efforts on mitigation of the effects in the diagnostics task have been identified. At ASTA we have designed the beam profiling stations to have mitigation features based on spectral filtering, scintillator choice, and the timing of the trigger to the digital camera's CCD chip. Since the COTR is more intense in the NIR than UV we have selectable bandpass filters centered at 420 nm which also overlap the spectral emissions of the LYSO:Ce scintillators. By delaying the CCD trigger timing of the integration window by 40-50 ns, we can reject the prompt OTR signal and integrate on the delayed scintillator light predominately. This combination of options should allow mitigation of COTR enhancements of order 100-1000 in the distribution.
△ Less
Submitted 9 September, 2014;
originally announced September 2014.
-
New class of biological detectors for WIMPs
Authors:
Andrzej K. Drukier,
Charles Cantor,
Mark Chonofsky,
George M. Church,
Robert L. Fagaly,
Katherine Freese,
Alejandro Lopez,
Takeshi Sano,
Christopher Savage,
Wesley P. Wong
Abstract:
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detection…
▽ More
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detections for certain dark matter scenarios and assuming a certain light response.
We propose the use of a new class of biological dark matter (DM) detectors to further examine this light dark matter hypothesis, taking advantage of new signatures with low atomic number targets, Two types of biological DM detectors are discussed here: DNA-based detectors and enzymatic reactions (ER) based detectors. In the case of DNA-based detectors, we discuss a new implementation. In the case of ER detectors, there are four crucial phases of the detection process: a) change of state due to energy deposited by a particle; b) amplification due to the release of energy derived from the action of an enzyme on its substrate; c) sustainable but non-explosive enzymatic reaction; d) self-termination due to the denaturation of the enzyme, when the temperature is raised. This paper provides information of how to design as well as optimize these four processes.
△ Less
Submitted 2 July, 2015; v1 submitted 31 March, 2014;
originally announced March 2014.
-
Physical Principles for Scalable Neural Recording
Authors:
Adam H. Marblestone,
Bradley M. Zamft,
Yael G. Maguire,
Mikhail G. Shapiro,
Thaddeus R. Cybulski,
Joshua I. Glaser,
Dario Amodei,
P. Benjamin Stranges,
Reza Kalhor,
David A. Dalrymple,
Dongjin Seo,
Elad Alon,
Michel M. Maharbiz,
Jose M. Carmena,
Jan M. Rabaey,
Edward S. Boyden,
George M. Church,
Konrad P. Kording
Abstract:
Simultaneously measuring the activities of all neurons in a mammalian brain at millisecond resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely new approaches may be required, motivating an analysis of the fundamental physical constraints on the problem. We outline the physical principles governing brain activity mapping using optical, electrical,magnetic re…
▽ More
Simultaneously measuring the activities of all neurons in a mammalian brain at millisecond resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely new approaches may be required, motivating an analysis of the fundamental physical constraints on the problem. We outline the physical principles governing brain activity mapping using optical, electrical,magnetic resonance, and molecular modalities of neural recording. Focusing on the mouse brain, we analyze the scalability of each method, concentrating on the limitations imposed by spatiotemporal resolution, energy dissipation, and volume displacement. We also study the physics of powering and communicating with microscale devices embedded in brain tissue.
△ Less
Submitted 16 September, 2013; v1 submitted 24 June, 2013;
originally announced June 2013.
-
The Advanced Superconducting Test Accelerator (ASTA) at Fermilab: A User-Driven Facility Dedicated to Accelerator Science \& Technology
Authors:
P. Piot,
V. Shiltsev,
S. Nagaitsev,
M. Church,
P. Garbincius,
S. Henderson,
J. Leibfritz
Abstract:
Fermilab is currently constructing a superconducting electron linac that will eventually serve as the backbone of a user-driven facility for accelerator science. This contribution describes the accelerator and summarizes the enabled research thrusts. A detailed description of the facility can be found at [\url{http://apc.fnal.gov/programs2/ASTA_TEMP/index.shtml}].
Fermilab is currently constructing a superconducting electron linac that will eventually serve as the backbone of a user-driven facility for accelerator science. This contribution describes the accelerator and summarizes the enabled research thrusts. A detailed description of the facility can be found at [\url{http://apc.fnal.gov/programs2/ASTA_TEMP/index.shtml}].
△ Less
Submitted 1 April, 2013;
originally announced April 2013.
-
Beam dynamics performances and applications of a low-energy electron-beam magnetic bunch compressor
Authors:
C. R. Prokop,
P. Piot,
B. E. Carlsten,
M. Church
Abstract:
Many front-end applications of electron linear accelerators rely on the production of temporally-compressed bunches. The shortening of electron bunches is often realized with magnetic bunch compressors located in high-energy sections of accelerators. Magnetic compression is subject to collective effects including space charge and self interaction via coherent synchrotron radiation. In this paper w…
▽ More
Many front-end applications of electron linear accelerators rely on the production of temporally-compressed bunches. The shortening of electron bunches is often realized with magnetic bunch compressors located in high-energy sections of accelerators. Magnetic compression is subject to collective effects including space charge and self interaction via coherent synchrotron radiation. In this paper we explore the application of magnetic compression to low-energy ($\sim 40$ MeV), high-charge (nC) electron bunches with low normalized transverse emittances ($< 5$ $μ$m).
△ Less
Submitted 4 February, 2013;
originally announced February 2013.
-
Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab
Authors:
J. Leibfritz,
R. Andrews,
C. M. Baffes,
K. Carlson,
B. Chase,
M. D. Church,
E. R. Harms,
A. L. Klebaner,
M. Kucera,
A. Martinez,
S. Nagaitsev,
L. E. Nobrega,
P. Piot,
J. Reid,
M. Wendt,
S. J. Wesseln
Abstract:
The Advanced Superconducting Test Acccelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beamlines for testing diagnostics and conducting various beam tests, and a hig…
▽ More
The Advanced Superconducting Test Acccelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beamlines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750-MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5-GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.
△ Less
Submitted 29 January, 2013;
originally announced January 2013.
-
Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab
Authors:
C. Baffes,
M. Church,
J. Leibfritz,
S. Oplt,
I. Rakhno
Abstract:
A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type RF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two be…
▽ More
A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type RF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a Helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. In addition, the potential for radiation-induced degradation of the graphite is discussed.
△ Less
Submitted 23 January, 2013;
originally announced January 2013.
-
Development of a machine protection system for the Superconducting Beam Test Facility at Fermilab
Authors:
A. Warner,
L. Carmichael,
M. Church,
R. Neswold
Abstract:
Fermilab's Superconducting RF Beam Test Facility currently under construction will produce electron beams capable of damaging the acceleration structures and the beam line vacuum chambers in the event of an aberrant accelerator pulse. The accelerator is being designed with the capability to operate with up to 3000 bunches per macro-pulse, 5Hz repetition rate and 1.5 GeV beam energy. It will be abl…
▽ More
Fermilab's Superconducting RF Beam Test Facility currently under construction will produce electron beams capable of damaging the acceleration structures and the beam line vacuum chambers in the event of an aberrant accelerator pulse. The accelerator is being designed with the capability to operate with up to 3000 bunches per macro-pulse, 5Hz repetition rate and 1.5 GeV beam energy. It will be able to sustain an average beam power of 72 KW at the bunch charge of 3.2 nC. Operation at full intensity will deposit enough energy in niobium material to approach the melting point of 2500 °C. In the early phase with only 3 cryomodules installed the facility will be capable of generating electron beam energies of 810 MeV and an average beam power that approaches 40 KW. In either case a robust Machine Protection System (MPS) is required to mitigate effects due to such large damage potentials. This paper will describe the MPS system being developed, the system requirements and the controls issues under consideration.
△ Less
Submitted 28 September, 2012;
originally announced September 2012.
-
Status and Plans for an SRF Accelerator Test Facility at Fermilab
Authors:
M. Church,
J. Leibfritz,
S. Nagaitsev
Abstract:
A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and multiple downstream beam lines for testing diagnostics and performing beam experiments. With 3 cryomodules installed this facility will initially be capable of ge…
▽ More
A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and multiple downstream beam lines for testing diagnostics and performing beam experiments. With 3 cryomodules installed this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. The facility can accommodate up to 6 cryomodules for a total beam energy of 1.5 GeV. This facility will be used to test SRF cryomodules under high intensity beam conditions, RF power equipment, instrumentation, and LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.
△ Less
Submitted 18 September, 2012;
originally announced September 2012.
-
Initial beam-profiling tests with the NML prototype station at the Fermilab A0 Photoinjector
Authors:
A. Lumpkin,
R. Flora,
A. S. Johnson,
J. Ruan,
J. Santucci,
V. Scarpine,
Y. -E. Sun,
R. Thurman-Keup,
M. Church,
M. Wendt
Abstract:
The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-μm thick YAG:Ce single crystal scintillator or a 1-μm thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface…
▽ More
The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam mode: either a 100-μm thick YAG:Ce single crystal scintillator or a 1-μm thin Al optical transition radiation (OTR) foil. The screens are oriented with the surface perpendicular to the beam direction. A downstream mirror with its surface at 45 degrees to the beam direction is used to direct the radiation into the optical transport. The optical system has better than 20 (10) μm rms spatial resolution when covering a vertical field of view of 18 (5) mm. The initial tests were performed at the A0 Photoinjector at a beam energy of ~15 MeV and with micropulse charges from 25 to 500 pC for beam sizes of 45 to 250 microns. Example results will be presented.
△ Less
Submitted 21 August, 2012;
originally announced August 2012.
-
Status and plans for a SRF accelerator test faciliy at Fermilab
Authors:
J. Leibfritz,
R. Andrews,
K. Carlson,
B. Chase,
M. Church,
E. Harms,
A. Klebaner,
M. Kucera,
S. Lackey,
A. Martinez,
S. Nagaitsev,
L. Nobrega,
P. Piot,
J. Reid,
M. Wendt,
S. Wesseln
Abstract:
A superconducting RF accelerator test facility is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high powe…
▽ More
A superconducting RF accelerator test facility is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. Expansion plans of the facility are underway that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. In addition to testing accelerator components, this facility will be used to test RF power equipment, instrumentation, LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.
△ Less
Submitted 17 August, 2012;
originally announced August 2012.
-
Summary report of working group 5: Beam and radiation generation, monitoring, and control
Authors:
Mike Church,
Ki-Yong Kim
Abstract:
This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated…
▽ More
This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated on specific new developments and recent investigations. The Working Group divided its sessions into four broad categories: cathodes and electron guns, radiation generation, beam diagnostics, and beam control and dynamics. This summary is divided into the same structure.
△ Less
Submitted 30 July, 2012;
originally announced July 2012.
-
Tevatron Beam Halo Collimation System: Design, Operational Experience and New Methods
Authors:
Nikolai Mokhov,
Jerry Annala,
Richard Carrigan,
Michael Church,
Alexander Drozhdin,
Todd Johnson,
Reilly Robert,
Vladimir Shiltsev,
Guilio Stancari,
Dean Still,
Alexander Valishev,
Xiao-Long Zhang,
Viktoriya Zvoda
Abstract:
Collimation of proton and antiproton beams in the Tevatron collider is required to protect CDF and D0 detectors and minimize their background rates, to keep irradiation of superconducting magnets under control, to maintain long-term operational reliability, and to reduce the impact of beam-induced radiation on the environment. In this article we briefly describe the design, practical implementatio…
▽ More
Collimation of proton and antiproton beams in the Tevatron collider is required to protect CDF and D0 detectors and minimize their background rates, to keep irradiation of superconducting magnets under control, to maintain long-term operational reliability, and to reduce the impact of beam-induced radiation on the environment. In this article we briefly describe the design, practical implementation and performance of the collider collimation system, methods to control transverse and longitudinal beam halo and two novel collimation techniques tested in the Tevatron.
△ Less
Submitted 2 May, 2012;
originally announced May 2012.
-
Experimental study of coherent synchrotron radiation in the emittance exchange line at the A0-photoinjector
Authors:
Jayakar C. T. Thangaraj,
R. Thurman-Keup,
A. Johnson,
A. H. Lumpkin,
H. Edwards,
J. Ruan,
J. Santucci,
Y. E. - Sun,
M. Church,
P. Piot
Abstract:
Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could…
▽ More
Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.
-
Experiment and simulations of sub-ps electron bunch train generation at Fermilab photoinjectors
Authors:
Y. -E Sun,
M. Church,
P. Piot,
C. R. Prokop
Abstract:
Recently the generation of electron bunch trains with sub-picosecond time structure has been experimentally demonstrated at the A0 photoinjector of Fermilab using a transverse-longitudinal phase-space exchange beamline. The temporal profile of the bunch train can be easily tuned to meet the requirements of the applications of modern accelerator beams. In this paper we report the A0 bunch-train exp…
▽ More
Recently the generation of electron bunch trains with sub-picosecond time structure has been experimentally demonstrated at the A0 photoinjector of Fermilab using a transverse-longitudinal phase-space exchange beamline. The temporal profile of the bunch train can be easily tuned to meet the requirements of the applications of modern accelerator beams. In this paper we report the A0 bunch-train experiment and explore numerically the possible extension of this technique to shorter time scales at the Fermilab SRF Accelerator Test Facility, a superconducting linear electron accelerator currently under construction in the NML building.
△ Less
Submitted 27 January, 2012;
originally announced January 2012.
-
Crab cavities for linear colliders
Authors:
G. Burt,
P. Ambattu,
R. Carter,
A. Dexter,
I. Tahir,
C. Beard,
M. Dykes,
P. Goudket,
A. Kalinin,
L. Ma,
P. McIntosh,
D. Shulte,
R. M. Jones,
L. Bellantoni,
B. Chase,
M. Church,
T. Khabouline,
A. Latina,
C. Adolphsen,
Z. Li,
A. Seryei,
L. Xiao
Abstract:
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity…
▽ More
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.
△ Less
Submitted 16 October, 2008;
originally announced October 2008.