-
Open-path Dual-comb Spectroscopy for Multispecies Trace Gas Detection in the 4.5 μm to 5 μm Spectral Region
Authors:
Fabrizio R. Giorgetta,
Jeff Peischl,
Daniel I. Herman,
Gabriel Ycas,
Ian Coddington,
Nathan R. Newbury,
Kevin C. Cossel
Abstract:
Open-path dual-comb spectroscopy provides multi-species atmospheric gas concentration measurements with high precision. Here, we extend open-path dual comb spectroscopy to the mid-infrared 5 μm atmospheric window, enabling atmospheric concentration retrievals of the primary greenhouse gases, N$_2$O, CO$_2$, and H$_2$O as well as the criterion air pollutants O$_3$ and CO across 600 m and 2 km round…
▽ More
Open-path dual-comb spectroscopy provides multi-species atmospheric gas concentration measurements with high precision. Here, we extend open-path dual comb spectroscopy to the mid-infrared 5 μm atmospheric window, enabling atmospheric concentration retrievals of the primary greenhouse gases, N$_2$O, CO$_2$, and H$_2$O as well as the criterion air pollutants O$_3$ and CO across 600 m and 2 km round-trip paths. We demonstrate measurements over a five-day period at two-minute temporal resolution with 80% uptime. The achieved precision is sufficient to resolve the atmospheric concentration variations of the multiple gas species; retrieved dry mixing ratios of CO and N$_2$O are in good agreement with a co-located point sensor. In addition, the retrieved ratio of excess CO vs CO$_2$ agrees with similar urban studies but disagrees with the US National Emission Inventory by a factor of 3. Our retrieved ratio of excess N$_2$O vs CO$_2$ exhibits a plume-dependent value, indicating the variability of sources of the greenhouse gas N$_2$O.
△ Less
Submitted 22 December, 2020;
originally announced December 2020.
-
Experimental constraint on axion-like particle coupling over seven orders of magnitude in mass
Authors:
Tanya S. Roussy,
Daniel A. Palken,
William B. Cairncross,
Benjamin M. Brubaker,
Daniel N. Gresh,
Matt Grau,
Kevin C. Cossel,
Kia Boon Ng,
Yuval Shagam,
Yan Zhou,
Victor V. Flambaum,
Konrad W. Lehnert,
Jun Ye,
Eric A. Cornell
Abstract:
We use our recent electric dipole moment (EDM) measurement data to constrain the possibility that the HfF$^+$ EDM oscillates in time due to interactions with candidate dark matter axion-like particles (ALPs). We employ a Bayesian analysis method which accounts for both the look-elsewhere effect and the uncertainties associated with stochastic density fluctuations in the ALP field. We find no evide…
▽ More
We use our recent electric dipole moment (EDM) measurement data to constrain the possibility that the HfF$^+$ EDM oscillates in time due to interactions with candidate dark matter axion-like particles (ALPs). We employ a Bayesian analysis method which accounts for both the look-elsewhere effect and the uncertainties associated with stochastic density fluctuations in the ALP field. We find no evidence of an oscillating EDM over a range spanning from 27 nHz to 400 mHz, and we use this result to constrain the ALP-gluon coupling over the mass range $10^{-22}-10^{-15}$ eV. This is the first laboratory constraint on the ALP-gluon coupling in the $10^{-17}-10^{-15}$ eV range, and the first laboratory constraint to properly account for the stochastic nature of the ALP field.
△ Less
Submitted 18 March, 2021; v1 submitted 28 June, 2020;
originally announced June 2020.
-
Dual-comb spectroscopy with tailored spectral broadening in Si$_3$N$_4$ nanophotonics
Authors:
Esther Baumann,
Eli V. Hoenig,
Edgar F. Perez,
Gabriel M. Colacion,
Fabrizio R. Giorgetta,
Kevin C. Cossel,
Gabriel Ycas,
David R. Carlson,
Daniel D. Hickstein,
Kartik Srinivasan,
Scott B. Papp,
Nathan R. Newbury,
Ian Coddington
Abstract:
Si$_3$N$_4$ waveguides, pumped at 1550 nm, can provide spectrally smooth, broadband light for gas spectroscopy in the important 2 ${\mathrmμ}$m to 2.5 ${\mathrmμ}$m atmospheric water window, which is only partially accessible with silica-fiber based systems. By combining Er+:fiber frequency combs and supercontinuum generation in tailored Si$_3$N$_4$ waveguides, high signal-to-noise dual-comb spect…
▽ More
Si$_3$N$_4$ waveguides, pumped at 1550 nm, can provide spectrally smooth, broadband light for gas spectroscopy in the important 2 ${\mathrmμ}$m to 2.5 ${\mathrmμ}$m atmospheric water window, which is only partially accessible with silica-fiber based systems. By combining Er+:fiber frequency combs and supercontinuum generation in tailored Si$_3$N$_4$ waveguides, high signal-to-noise dual-comb spectroscopy (DCS) spanning 2 ${\mathrmμ}$m to 2.5 ${\mathrmμ}$m is demonstrated. Acquired broadband dual-comb spectra of CO and CO$_2$ agree well with database line shape models and have a spectral-signal-to-noise as high as 48$/\sqrt{\mathrm{s}}$, showing that the high coherence between the two combs is retained in the Si$_3$N$_4$ supercontinuum generation. The DCS figure of merit is 6$\times 10^6/\sqrt{\mathrm{s}}$, equivalent to that of all-fiber DCS systems in the 1.6 ${\mathrmμ}$m band. Based on these results, future DCS can combine fiber comb technology with Si$_3$N$_4$ waveguides to access new spectral windows in a robust non-laboratory platform.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
Femtosecond Synchronization of Optical Clocks Off of a Flying Quadcopter
Authors:
Hugo Bergeron,
Laura C. Sinclair,
William C. Swann,
Isaac Khader,
Kevin C. Cossel,
Michael Cermak,
Jean-Daniel Deschênes,
Nathan R. Newbury
Abstract:
Future optical clock networks will require free-space optical time-frequency transfer between flying clocks. However, simple one-way or standard two-way time transfer between flying clocks will completely break down because of the time-of-flight variations and Doppler shifts associated with the strongly time-varying optical link distances. Here, we demonstrate an advanced, comb-based optical two-w…
▽ More
Future optical clock networks will require free-space optical time-frequency transfer between flying clocks. However, simple one-way or standard two-way time transfer between flying clocks will completely break down because of the time-of-flight variations and Doppler shifts associated with the strongly time-varying optical link distances. Here, we demonstrate an advanced, comb-based optical two-way time-frequency transfer that can successfully synchronize the optical timescales at two sites connected via a time-varying turbulent air path. The link between the two sites is established using either a quadcopter-mounted retroreflector or a swept delay line at speeds up to 24 m/s. Despite 50-ps breakdown in time-of-flight reciprocity, the sites' timescales are synchronized to < 1 fs in time deviation. The corresponding sites' frequencies agree to $\sim$ $10^{-18}$ despite $10^{-7}$ Doppler shifts. This work demonstrates comb-based O-TWTFT can enable free-space optical networks between airborne or satellite-borne optical clocks for precision navigation, timing and probes of fundamental science.
△ Less
Submitted 20 December, 2018; v1 submitted 22 August, 2018;
originally announced August 2018.
-
Femtosecond Optical Two-Way Time-Frequency Transfer in the Presence of Motion
Authors:
Laura C. Sinclair,
Hugo Bergeron,
William C. Swann,
Isaac Khader,
Kevin C. Cossel,
Michael Cermak,
Nathan R. Newbury,
Jean-Daniel Deschênes
Abstract:
Platform motion poses significant challenges to high-precision optical time and frequency transfer. We give a detailed description of these challenges and their solutions in comb-based optical two-way time and frequency transfer (O-TWTFT). Specifically, we discuss the breakdown in reciprocity due to relativity and due to asynchronous sampling, the impact of optical and electrical dispersion, and v…
▽ More
Platform motion poses significant challenges to high-precision optical time and frequency transfer. We give a detailed description of these challenges and their solutions in comb-based optical two-way time and frequency transfer (O-TWTFT). Specifically, we discuss the breakdown in reciprocity due to relativity and due to asynchronous sampling, the impact of optical and electrical dispersion, and velocity-dependent transceiver calibration. We present a detailed derivation of the equations governing comb-based O-TWTFT in the presence of motion. We describe the implementation of real-time signal processing algorithms based on these equations and demonstrate active synchronization of two sites over turbulent air paths to below a femtosecond time deviation despite effective velocities of +/-25 m/s, which is the maximum achievable with our physical setup. With the implementation of the time transfer equation derived here, we find no velocity-dependent bias between the synchronized clocks to within at two-sigma statistical uncertainty of 330 attoseconds.
△ Less
Submitted 21 August, 2018;
originally announced August 2018.
-
A precision measurement of the electron's electric dipole moment using trapped molecular ions
Authors:
William B. Cairncross,
Daniel N. Gresh,
Matt Grau,
Kevin C. Cossel,
Tanya S. Roussy,
Yiqi Ni,
Yan Zhou,
Jun Ye,
Eric A. Cornell
Abstract:
We describe the first precision measurement of the electron's electric dipole moment (eEDM, $d_e$) using trapped molecular ions, demonstrating the application of spin interrogation times over 700 ms to achieve high sensitivity and stringent rejection of systematic errors. Through electron spin resonance spectroscopy on $^{180}{\rm Hf}^{19}{\rm F}^{+}$ in its metastable $^{3}Δ_{1}$ electronic state…
▽ More
We describe the first precision measurement of the electron's electric dipole moment (eEDM, $d_e$) using trapped molecular ions, demonstrating the application of spin interrogation times over 700 ms to achieve high sensitivity and stringent rejection of systematic errors. Through electron spin resonance spectroscopy on $^{180}{\rm Hf}^{19}{\rm F}^{+}$ in its metastable $^{3}Δ_{1}$ electronic state, we obtain $d_e = (0.9 \pm 7.7_{\rm stat} \pm 1.7_{\rm syst}) \times 10^{-29}\,e\,{\rm cm}$, resulting in an upper bound of $|d_e| < 1.3 \times 10^{-28}\,e\,{\rm cm}$ (90% confidence). Our result provides independent confirmation of the current upper bound of $|d_e| < 9.3 \times 10^{-29}\,e\,{\rm cm}$ [J. Baron $\textit{et al.}$, Science $\textbf{343}$, 269 (2014)], and offers the potential to improve on this limit in the near future.
△ Less
Submitted 25 April, 2017;
originally announced April 2017.
-
Accurate frequency referencing for fieldable dual-comb spectroscopy
Authors:
Gar-Wing Truong,
Eleanor M. Waxman,
Kevin C. Cossel,
Esther Baumann,
Andrew Klose,
Fabrizio R. Giorgetta,
William C. Swann,
Nathan R. Newbury,
Ian Coddington
Abstract:
A fieldable dual-comb spectrometer is described based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. This fieldable dual-comb spectrometer was used to measure spectra with full…
▽ More
A fieldable dual-comb spectrometer is described based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. This fieldable dual-comb spectrometer was used to measure spectra with full comb-tooth resolution spanning from 140 THz (2.14 um, 4670 cm^-1) to 184 THz (1.63 um, 6140 cm^-1) in the near infrared with a frequency sampling of 200 MHz (0.0067 cm^-1), ~ 120 kHz frequency resolution, and ~ 1 MHz frequency accuracy. High resolution spectra of water and carbon dioxide transitions at 1.77 um, 1.96 um and 2.06 um show that the molecular transmission acquired with this fieldable system did not deviate from those measured with a laboratory-based system (referenced to a maser and cavity-stabilized laser) to within 5.6x10^-4. Additionally, the fieldable system optimized for carbon dioxide quantification at 1.60 um, demonstrated a sensitivity of 2.8 ppm-km at 1 s integration time, improving to 0.10 ppm-km at 13 minutes of integration time.
△ Less
Submitted 30 November, 2016;
originally announced December 2016.
-
A versatile, inexpensive integrated photonics platform
Authors:
Jeffrey M. Shainline,
Sonia M. Buckley,
Nima Nader,
Cale M. Gentry,
Kevin C. Cossel,
Miloš Popović,
Nathan R. Newbury,
Sae Woo Nam,
Richard P. Mirin
Abstract:
We present an approach to fabrication and packaging of integrated photonic devices that utilizes waveguide and detector layers deposited at near-ambient temperature. All lithography is performed with a 365 nm i-line stepper, facilitating low cost and high scalability. We have shown low-loss SiN waveguides, high-$Q$ ring resonators, critically coupled ring resonators, 50/50 beam splitters, Mach-Zeh…
▽ More
We present an approach to fabrication and packaging of integrated photonic devices that utilizes waveguide and detector layers deposited at near-ambient temperature. All lithography is performed with a 365 nm i-line stepper, facilitating low cost and high scalability. We have shown low-loss SiN waveguides, high-$Q$ ring resonators, critically coupled ring resonators, 50/50 beam splitters, Mach-Zehnder interferometers (MZIs) and a process-agnostic fiber packaging scheme. We have further explored the utility of this process for applications in nonlinear optics and quantum photonics. We demonstrate spectral tailoring and octave-spanning supercontinuum generation as well as the integration of superconducting nanowire single photon detectors with MZIs and channel-dropping filters. The packaging approach is suitable for operation up to 160 \degree C as well as below 1 K. The process is well suited for augmentation of existing foundry capabilities or as a stand-alone process.
△ Less
Submitted 7 November, 2016;
originally announced November 2016.
-
Broadband velocity modulation spectroscopy of ThF$^+$ for use in a measurement of the electron electric dipole moment
Authors:
Daniel N. Gresh,
Kevin C. Cossel,
Yan Zhou,
Jun Ye,
Eric A. Cornell
Abstract:
A number of extensions to the Standard Model of particle physics predict a permanent electric dipole moment of the electron (eEDM) in the range of the current experimental limits. Trapped ThF$^+$ will be used in a forthcoming generation of the JILA eEDM experiment. Here, we present extensive survey spectroscopy of ThF$^+$ in the 700 - 1000 nm spectral region, with the 700 - 900 nm range fully cove…
▽ More
A number of extensions to the Standard Model of particle physics predict a permanent electric dipole moment of the electron (eEDM) in the range of the current experimental limits. Trapped ThF$^+$ will be used in a forthcoming generation of the JILA eEDM experiment. Here, we present extensive survey spectroscopy of ThF$^+$ in the 700 - 1000 nm spectral region, with the 700 - 900 nm range fully covered using frequency comb velocity modulation spectroscopy. We have determined that the ThF$^+$ electronic ground state is $X$ $^3Δ_1$, which is the eEDM-sensitive state. In addition, we report high-precision rotational and vibrational constants for 14 ThF$^+$ electronic states, including excited states that can be used to transfer and readout population in the eEDM experiment.
△ Less
Submitted 11 September, 2015;
originally announced September 2015.
-
State-specific detection of trapped HfF$^+$ by photodissociation
Authors:
Kang-Kuen Ni,
Huanqian Loh,
Matt Grau,
Kevin C. Cossel,
Jun Ye,
Eric A. Cornell
Abstract:
We use (1+1$'$) resonance-enhanced multiphoton photodissociation (REMPD) to detect the population in individual rovibronic states of trapped HfF$^+$ with a single-shot absolute efficiency of 18%, which is over 200 times better than that obtained with fluorescence detection. The first photon excites a specific rotational level to an intermediate vibronic band at 35,000-36,500 cm$^{-1}$, and the sec…
▽ More
We use (1+1$'$) resonance-enhanced multiphoton photodissociation (REMPD) to detect the population in individual rovibronic states of trapped HfF$^+$ with a single-shot absolute efficiency of 18%, which is over 200 times better than that obtained with fluorescence detection. The first photon excites a specific rotational level to an intermediate vibronic band at 35,000-36,500 cm$^{-1}$, and the second photon, at 37,594 cm$^{-1}$ (266 nm), dissociates HfF$^+$ into Hf$^+$ and F. Mass-resolved time-of-flight ion detection then yields the number of state-selectively dissociated ions. Using this method, we observe rotational-state heating of trapped HfF$^+$ ions from collisions with neutral Ar atoms. Furthermore, we measure the lifetime of the $^3Δ_1$ $v=0,\, J=1$ state to be 2.1(2) s. This state will be used for a search for a permanent electric dipole moment of the electron.
△ Less
Submitted 21 January, 2014;
originally announced January 2014.
-
Precision Spectroscopy of Polarized Molecules in an Ion Trap
Authors:
Huanqian Loh,
Kevin C. Cossel,
Matt Grau,
Kang-Kuen Ni,
Edmund R. Meyer,
John L. Bohn,
Jun Ye,
Eric A. Cornell
Abstract:
Polar molecules are desirable systems for quantum simulations and cold chemistry. Molecular ions are easily trapped, but a bias electric field applied to polarize them tends to accelerate them out of the trap. We present a general solution to this issue by rotating the bias field slowly enough for the molecular polarization axis to follow but rapidly enough for the ions to stay trapped. We demonst…
▽ More
Polar molecules are desirable systems for quantum simulations and cold chemistry. Molecular ions are easily trapped, but a bias electric field applied to polarize them tends to accelerate them out of the trap. We present a general solution to this issue by rotating the bias field slowly enough for the molecular polarization axis to follow but rapidly enough for the ions to stay trapped. We demonstrate Ramsey spectroscopy between Stark-Zeeman sublevels in 180Hf19F+ with a coherence time of 100 ms. Frequency shifts arising from well-controlled topological (Berry) phases are used to determine magnetic g-factors. The rotating-bias-field technique may enable using trapped polar molecules for precision measurement and quantum information science, including the search for an electron electric dipole moment.
△ Less
Submitted 13 November, 2013;
originally announced November 2013.
-
Broadband velocity modulation spectroscopy of HfF^+: towards a measurement of the electron electric dipole moment
Authors:
Kevin C. Cossel,
Daniel N. Gresh,
Laura C. Sinclair,
Tyler Coffey,
Leonid V. Skripnikov,
Alexander N. Petrov,
Nikolai S. Mosyagin,
Anatoly V. Titov,
Robert W. Field,
Edmund R. Meyer,
Eric A. Cornell,
Jun Ye
Abstract:
Precision spectroscopy of trapped HfF^+ will be used in a search for the permanent electric dipole moment of the electron (eEDM). While this dipole moment has yet to be observed, various extensions to the standard model of particle physics (such as supersymmetry) predict values that are close to the current limit. We present extensive survey spectroscopy of 19 bands covering nearly 5000 cm^(-1) us…
▽ More
Precision spectroscopy of trapped HfF^+ will be used in a search for the permanent electric dipole moment of the electron (eEDM). While this dipole moment has yet to be observed, various extensions to the standard model of particle physics (such as supersymmetry) predict values that are close to the current limit. We present extensive survey spectroscopy of 19 bands covering nearly 5000 cm^(-1) using both frequency-comb and single-frequency laser velocity-modulation spectroscopy. We obtain high-precision rovibrational constants for eight electronic states including those that will be necessary for state preparation and readout in an actual eEDM experiment.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.
-
Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection
Authors:
Lora Nugent-Glandorf,
Tyler Neely,
Florian Adler,
Adam J. Fleisher,
Kevin C. Cossel,
Bryce Bjork,
Tim Dinneen,
Jun Ye,
Scott A. Diddams
Abstract:
We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection,…
▽ More
We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, rapid, time-resolved single-image detection is demonstrated by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5\times 10-4 are readily detected on the millisecond time scale, leading to important future applications such as real time monitoring of trace gas concentrations and detection of reactive intermediates.
△ Less
Submitted 6 June, 2012;
originally announced June 2012.
-
Frequency Comb Velocity-Modulation Spectroscopy
Authors:
Laura C. Sinclair,
Kevin C. Cossel,
Tyler Coffey,
Jun Ye,
Eric A. Cornell
Abstract:
We have demonstrated a new technique that provides massively parallel comb spectroscopy sensitive specifically to ions through the combination of cavity-enhanced direct frequency comb spectroscopy with velocity modulation spectroscopy. Using this novel system, we have measured electronic transitions of HfF+ and achieved a fractional absorption sensitivity of 3 x 10-7 recorded over 1500 simultaneou…
▽ More
We have demonstrated a new technique that provides massively parallel comb spectroscopy sensitive specifically to ions through the combination of cavity-enhanced direct frequency comb spectroscopy with velocity modulation spectroscopy. Using this novel system, we have measured electronic transitions of HfF+ and achieved a fractional absorption sensitivity of 3 x 10-7 recorded over 1500 simultaneous channels spanning 150 cm-1 around 800 nm with an absolute frequency accuracy of 30 MHz (0.001 cm-1). A fully sampled spectrum consisting of interleaved measurements is acquired in 30 minutes.
△ Less
Submitted 14 July, 2011;
originally announced July 2011.
-
Ultra-Broadband Coherent Supercontinuum Frequency Comb
Authors:
Axel Ruehl,
Michael. J. Martin,
Kevin C. Cossel,
Lisheng Chen,
Hugh McKay,
Brian Thomas,
Craig Benko,
Liang Dong,
John M. Dudley,
Martin E. Fermann,
Ingmar Hartl,
Jun Ye
Abstract:
We present detailed studies of the coherence properties of an ultra-broadband super-continuum, enabled by a new approach involving continuous wave laser sources to independently probe both the amplitude and phase noise quadratures across the entire spectrum. The continuum coherently spans more than 1.5 octaves, supporting Hz-level comparison of ultrastable lasers at 698 nm and 1.54 μm. We present…
▽ More
We present detailed studies of the coherence properties of an ultra-broadband super-continuum, enabled by a new approach involving continuous wave laser sources to independently probe both the amplitude and phase noise quadratures across the entire spectrum. The continuum coherently spans more than 1.5 octaves, supporting Hz-level comparison of ultrastable lasers at 698 nm and 1.54 μm. We present the first numerical simulation of the accumulated comb coherence in the limit of many pulses, in contrast to the single-pulse level, with systematic experimental verification. The experiment and numerical simulations reveal the presence of quantum-seeded broadband amplitude noise without phase coherence degradation, including the discovery of a dependence of the super-continuum coherence on the fiber fractional Raman gain.
△ Less
Submitted 10 May, 2011;
originally announced May 2011.
-
Mid-Infrared Frequency Comb Fourier Transform Spectrometer
Authors:
Florian Adler,
Piotr Masłowski,
Aleksandra Foltynowicz,
Kevin C. Cossel,
Travis C. Briles,
Ingmar Hartl,
Jun Ye
Abstract:
Optical frequency-comb-based-high-resolution spectrometers offer enormous potential for spectroscopic applications. Although various implementations have been demonstrated, the lack of suitable mid-infrared comb sources has impeded explorations of molecular fingerprinting. Here we present for the first time a frequency-comb Fourier transform spectrometer operating in the 2100-to-3700-cm-1 spectral…
▽ More
Optical frequency-comb-based-high-resolution spectrometers offer enormous potential for spectroscopic applications. Although various implementations have been demonstrated, the lack of suitable mid-infrared comb sources has impeded explorations of molecular fingerprinting. Here we present for the first time a frequency-comb Fourier transform spectrometer operating in the 2100-to-3700-cm-1 spectral region that allows fast and simultaneous acquisitions of broadband absorption spectra with up to 0.0056 cm-1 resolution. We demonstrate part-per-billion detection limits in 30 seconds of integration time for various important molecules including methane, ethane, isoprene, and nitrous oxide. Our system enables precise concentration measurements even in gas mixtures that exhibit continuous absorption bands, and it allows detection of molecules at levels below the noise floor via simultaneous analysis of multiple spectral features. This system represents a near real-time, high-resolution, high-bandwidth mid-infrared spectrometer which is ready to replace traditional Fourier transform spectrometers for many applications in trace gas detection, atmospheric science, and medical diagnostics.
△ Less
Submitted 24 September, 2010; v1 submitted 5 July, 2010;
originally announced July 2010.
-
Analysis of Trace Impurities in Semiconductor Gas via Cavity-Enhanced Direct Frequency Comb Spectroscopy
Authors:
Kevin C. Cossel,
Florian Adler,
Kris A. Bertness,
Michael J. Thorpe,
Jun Feng,
Mark W. Raynor,
Jun Ye
Abstract:
Cavity-enhanced direct frequency comb spectroscopy (CE-DFCS) has demonstrated powerful potential for trace gas detection based on its unique combination of high bandwidth, rapid data acquisition, high sensitivity, and high resolution, which is unavailable with conventional systems. However, previous demonstrations have been limited to proof-of-principle experiments or studies of fundamental labora…
▽ More
Cavity-enhanced direct frequency comb spectroscopy (CE-DFCS) has demonstrated powerful potential for trace gas detection based on its unique combination of high bandwidth, rapid data acquisition, high sensitivity, and high resolution, which is unavailable with conventional systems. However, previous demonstrations have been limited to proof-of-principle experiments or studies of fundamental laboratory science. Here we present the development of CE-DFCS towards an industrial application -- measuring impurities in arsine, an important process gas used in III-V semiconductor compound manufacturing. A strongly absorbing background gas with an extremely complex, congested, and broadband spectrum renders trace detection exceptionally difficult, but the capabilities of CE-DFCS overcome this challenge and make it possible to identify and quantify multiple spectral lines associated with water impurities. Further, frequency combs allow easy access to new spectral regions via efficient nonlinear optical processes. Here, we demonstrate detection of multiple potential impurities across 1.75-1.95 um (5710-5130 cm-1) with single-channel detection sensitivities of ~1 x 10-7 cm-1 Hz-1/2 in nitrogen and identify water doped in arsine with a sensitivity of ~1 x 10-6 cm-1 Hz-1/2.
△ Less
Submitted 12 November, 2010; v1 submitted 5 March, 2010;
originally announced March 2010.
-
Phase-stabilized, 1.5-W frequency comb at 2.8 to 4.8 micron
Authors:
Florian Adler,
Kevin C. Cossel,
Michael J. Thorpe,
Ingmar Hartl,
Martin E. Fermann,
Jun Ye
Abstract:
We present a high-power optical parametric oscillator-based frequency comb in the mid-infrared wavelength region using periodically poled lithium niobate. The system is synchronously pumped by a 10-W femtosecond Yb:fiber laser centered at 1.07 um and is singly resonant for the signal. The idler (signal) wavelength can be continuously tuned from 2.8 to 4.8 um (1.76 to 1.37 um) with a simultaneous…
▽ More
We present a high-power optical parametric oscillator-based frequency comb in the mid-infrared wavelength region using periodically poled lithium niobate. The system is synchronously pumped by a 10-W femtosecond Yb:fiber laser centered at 1.07 um and is singly resonant for the signal. The idler (signal) wavelength can be continuously tuned from 2.8 to 4.8 um (1.76 to 1.37 um) with a simultaneous bandwidth as high as 0.3 um and a maximum average idler output power of 1.50 W. We also demonstrate the performance of the stabilized comb by recording the heterodyne beat with a narrow-linewidth diode laser. This OPO is an ideal source for frequency comb spectroscopy in the mid-IR.
△ Less
Submitted 11 February, 2009;
originally announced February 2009.