-
Shaping an evanescent focus of light for high spatial resolution optogenetic activations in live cells
Authors:
Marc Grosjean,
Alexei Grichine,
Mylene Pezet,
Olivier Destaing,
Antoine Delon,
Irène Wang
Abstract:
Confining light illumination in the three dimensions of space is a challenge for various applications. Among these, optogenetic methods developed for live experiments in cell biology would benefit from such a localized illumination as it would improve the spatial resolution of diffusive photosensitive proteins leading to spatially constrained biological responses in specific subcellular organelles…
▽ More
Confining light illumination in the three dimensions of space is a challenge for various applications. Among these, optogenetic methods developed for live experiments in cell biology would benefit from such a localized illumination as it would improve the spatial resolution of diffusive photosensitive proteins leading to spatially constrained biological responses in specific subcellular organelles. Here, we describe a method to create and move a focused evanescent spot across the field of view of a high numerical aperture microscope objective, using a digital micro-mirror device (DMD). We show that, after correcting the optical aberrations, light is confined within a spot of sub-micron lateral size and $\sim$100~nm axial depth, resulting in a volume of illumination drastically smaller than the one generated by a standard propagative focus. This evanescent focus is sufficient to induce a more intense and localized recruitment compared to a propagative focus on the optogenetic system CRY2-CIBN, improving the resolution of its pattern of activation.
△ Less
Submitted 23 April, 2024; v1 submitted 1 March, 2024;
originally announced March 2024.
-
Combining fluorescence fluctuations and photobleaching to quantify surface density
Authors:
Julius Sefkow-Werner,
Elisa Migliorini,
Catherine Picart,
Dwiria Wahyuni,
Irene Wang,
Antoine Delon
Abstract:
We establish a method, called pbFFS for photobleaching Fluctuation Fluorescence Spectroscopy, which aims at characterizing molecules or particles labelled with a unknown distribution or fluorophores. Using photobleaching as a control parameter, pbFFS provides information on the distribution of labels and a more reliable estimation of the absolute density or concentration of these molecules. We pre…
▽ More
We establish a method, called pbFFS for photobleaching Fluctuation Fluorescence Spectroscopy, which aims at characterizing molecules or particles labelled with a unknown distribution or fluorophores. Using photobleaching as a control parameter, pbFFS provides information on the distribution of labels and a more reliable estimation of the absolute density or concentration of these molecules. We present a complete theoretical derivation of the pbFFS approach and experimentally apply it to measure the surface density of a monolayer of fluorescently tagged streptavidin molecules that can be used as a base platform for biomimetic systems. The surface density measured by pbFFS is consistent with the results of more standard surface techniques, such as ellipsometry. Compared to those techniques, pbFFS has two main advantages: it enables in situ characterization (no dedicated substrates are required) and is applicable to low masses of adsorbed molecules, as demonstrated here by quantifying the density of biotin-Atto molecules that bind to the streptavidin layer. Besides molecules immobilized on surfaces, we also applied pbFFS to molecules diffusing in solution, to confirm the distribution of labels found on surfaces. Hence, pbFFS provides a set of tools to investigate molecules attached to a variable number of fluorophores, with the aim toquantify either the number of molecules or the distribution of fluorophores, the latter case being especially relevant for oligomerization studies.
△ Less
Submitted 24 January, 2022; v1 submitted 27 October, 2021;
originally announced October 2021.
-
Optimal transfer functions for bandwidth-limited imaging
Authors:
Sjoerd Stallinga,
Niels Radmacher,
Antoine Delon,
Jörg Enderlein
Abstract:
One of the fundamental limits of classical optical microscopy is the diffraction limit of optical resolution. It results from the finite bandwidth of the optical transfer function (or OTF) of an optical microscope, which restricts the maximum spatial frequencies that are transmitted by a microscope. However, given the frequency support of the OTF, which is fully determined by the used optical hard…
▽ More
One of the fundamental limits of classical optical microscopy is the diffraction limit of optical resolution. It results from the finite bandwidth of the optical transfer function (or OTF) of an optical microscope, which restricts the maximum spatial frequencies that are transmitted by a microscope. However, given the frequency support of the OTF, which is fully determined by the used optical hardware, an open and unsolved question is what is the optimal amplitude and phase distribution of spatial frequencies across this support that delivers the "sharpest" possible image. In this paper, we will answer this question and present a general rule how to find the optimal OTF for any given imaging system. We discuss our result in the context of optical microscopy, by considering in particular the cases of wide-field microscopy, confocal Image Scanning Microscopy (ISM), 4pi microscopy, and Structured Illumination Microscopy (SIM). Our results are important for finding optimal deconvolution algorithms for microscopy images, and we demonstrate this experimentally on the example of ISM. Our results can also serve as a guideline for designing optical systems that deliver best possible images, and they can be easily generalized to non-optical imaging such as telescopic imaging, ultrasound imaging, or magnetic resonance imaging.
△ Less
Submitted 10 March, 2022; v1 submitted 10 October, 2021;
originally announced October 2021.
-
Modeling Fluorescence Correlation Spectroscopy through an aberrating sphere
Authors:
Daja Ruhlandt,
Aditya Katti,
Jacques Derouard,
Antoine Delon,
Jörg Enderlein
Abstract:
Fluorescence Correlation Spectroscopy (FCS) is a powerful single-molecule technique which allows for measuring motion (diffusion, flow), concentration, and molecular interaction kinetics of fluorescent molecules from picomolar to micromolar concentrations. It has found manifold applications in the physical and life sciences. Many biological/biophysical applications use FCS for measuring the motion…
▽ More
Fluorescence Correlation Spectroscopy (FCS) is a powerful single-molecule technique which allows for measuring motion (diffusion, flow), concentration, and molecular interaction kinetics of fluorescent molecules from picomolar to micromolar concentrations. It has found manifold applications in the physical and life sciences. Many biological/biophysical applications use FCS for measuring the motion and concentration of fluorescently labeled biomolecules in living cells and tissue. However, a correct quantitative evaluation of FCS experiments relies on the accurate knowledge of the fluorescence excitation and detection properties of the used confocal microscope. Using a bottom-up approach, we theoretically study how these properties are affected by the presence of a diffracting dielectric bead within the optical path, and how this changes the outcome of a FCS measurement. This will be important for all applications of FCS under optically non-ideal aberrating conditions.
△ Less
Submitted 16 July, 2019;
originally announced July 2019.
-
Shear instability of an axisymmetric air-water coaxial jet
Authors:
Jean-Philippe Matas,
Antoine Delon,
Alain Cartellier
Abstract:
We study the destabilization of a round liquid jet by a fast annular gas stream. We measure the frequency of the shear instability waves for several geometries and air/water velocities. We then carry out a linear stability analysis, and show that there are three competing mechanisms for the destabilization: a convective instability, an absolute instability driven by surface tension, and an absolut…
▽ More
We study the destabilization of a round liquid jet by a fast annular gas stream. We measure the frequency of the shear instability waves for several geometries and air/water velocities. We then carry out a linear stability analysis, and show that there are three competing mechanisms for the destabilization: a convective instability, an absolute instability driven by surface tension, and an absolute instability driven by confinement. We compare the predictions of this analysis with experimental results, and propose scaling laws for wave frequency in each regime. We finally introduce criteria to predict the boundaries between these three regimes.
△ Less
Submitted 7 February, 2018; v1 submitted 27 November, 2017;
originally announced November 2017.
-
Correction of cell-induced optical aberrations in a fluorescence fluctuation microscope
Authors:
Charles-Edouard Leroux,
Alexei Grichine,
Irène Wang,
Antoine Delon
Abstract:
We describe the effect of optical aberrations on fluorescence fluctuations microscopy (FFM), when focusing through a single living cell. FFM measurements are performed in an aqueous fluorescent solution and prove to be a highly sensitive tool to assess the optical aberrations introduced by the cell. We demonstrate an adaptive optics (AO) system to remove the aberration-related bias in the FFM meas…
▽ More
We describe the effect of optical aberrations on fluorescence fluctuations microscopy (FFM), when focusing through a single living cell. FFM measurements are performed in an aqueous fluorescent solution and prove to be a highly sensitive tool to assess the optical aberrations introduced by the cell. We demonstrate an adaptive optics (AO) system to remove the aberration-related bias in the FFM measurements. Our data show that AO is not only useful when imaging deep in tissues but also when performing FFM measurements through a single cellular layer. This work paves the way for the application of FFM to complex three-dimensional multicellular samples.
△ Less
Submitted 12 March, 2014;
originally announced March 2014.
-
Multi-confocal Fluorescence Correlation Spectroscopy : experimental demonstration and potential applications for living cell measurements
Authors:
Rémi Galland,
Jie Gao,
Meike Kloster,
Gaetan Herbomel,
Olivier Destaing,
Martial Balland,
Catherine Souchier,
Yves Usson,
Jacques Derouard,
Irène Wang,
Antoine Delon
Abstract:
We report, for the first time, a multi-confocal Fluorescence Correlation Spectroscopy (mFCS) technique which allows parallel measurements at different locations, by combining a Spatial Light Modulator (SLM), with an Electron Multiplying-CCD camera (EM-CCD). The SLM is used to produce a series of laser spots, while the pixels of the EM-CCD play the roles of virtual pinholes. The phase map addressed…
▽ More
We report, for the first time, a multi-confocal Fluorescence Correlation Spectroscopy (mFCS) technique which allows parallel measurements at different locations, by combining a Spatial Light Modulator (SLM), with an Electron Multiplying-CCD camera (EM-CCD). The SLM is used to produce a series of laser spots, while the pixels of the EM-CCD play the roles of virtual pinholes. The phase map addressed to the SLM is calculated by using the spherical wave approximation and makes it possible to produce several diffraction limited laser spots, either aligned or spread over the field of view. To attain fast enough imaging rates, the camera has been used in different acquisition modes, the fastest of which leads to a time resolution of 100 $μ$s. We qualified the experimental set-up by using solutions of sulforhodamine G in glycerol and demonstrated that the observation volumes are similar to that of a standard confocal set-up. To demonstrate that our mFCS method is suitable for intracellular studies, experiments have been conducted on two stable cell lines: mouse embryonic fibroblasts expressing eGFP-actin and H1299 cells expressing the heat shock factor fusion protein HSF1-eGFP. In the first case we could recover, by analyzing the auto-correlation curves, the diffusion constant of G-actin within the cytoplasm, although we were also sensitive to the complex network of interactions with F-actin. Concerning HSF1, we could clearly observe the modifications of the number of molecules and of the HSF1 dynamics during heat shock.
△ Less
Submitted 22 December, 2011;
originally announced December 2011.
-
Adaptive Optics for Fluorescence Correlation Spectroscopy
Authors:
Charles Edouard Leroux,
Irène Wang,
Jacques Derouard,
Antoine Delon
Abstract:
Fluorescence Correlation Spectroscopy (FCS) yields measurement parameters (number of molecules, diffusion time) that characterize the concentration and kinetics of fluorescent molecules within a supposedly known observation volume. Absolute derivation of concentrations and diffusion constants therefore requires preliminary calibrations of the confocal Point Spread Function with phantom solutions u…
▽ More
Fluorescence Correlation Spectroscopy (FCS) yields measurement parameters (number of molecules, diffusion time) that characterize the concentration and kinetics of fluorescent molecules within a supposedly known observation volume. Absolute derivation of concentrations and diffusion constants therefore requires preliminary calibrations of the confocal Point Spread Function with phantom solutions under perfectly controlled environmental conditions. In this paper, we quantify the influence of optical aberrations on single photon FCS and demonstrate a simple Adaptive Optics system for aberration correction. Optical aberrations are gradually introduced by focussing the excitation laser beam at increasing depths in fluorescent solutions with various refractive indices, which leads to drastic depth-dependent bias in the estimated FCS parameters. Aberration correction with a Deformable Mirror stabilizes these parameters within a range of several tens of \mum into the solution. We also demonstrate, both theoretically and experimentally, that the molecular brightness scales as the Strehl ratio squared.
△ Less
Submitted 17 October, 2011;
originally announced October 2011.
-
Measuring, in solution, multiple-fluorophore labeling by combining Fluorescence Correlation Spectroscopy and photobleaching
Authors:
Antoine Delon,
Irène Wang,
Emeline Lambert,
Silva Lerbs-Mache,
Régis Mache,
Jacques Derouard,
Vincent Motto-Ros,
Rémi Galland
Abstract:
Determining the number of fluorescent entities that are coupled to a given molecule (DNA, protein, etc.) is a key point of numerous biological studies, especially those based on a single molecule approach. Reliable methods are important, in this context, not only to characterize the labeling process, but also to quantify interactions, for instance within molecular complexes. We combined Fluoresc…
▽ More
Determining the number of fluorescent entities that are coupled to a given molecule (DNA, protein, etc.) is a key point of numerous biological studies, especially those based on a single molecule approach. Reliable methods are important, in this context, not only to characterize the labeling process, but also to quantify interactions, for instance within molecular complexes. We combined Fluorescence Correlation Spectroscopy (FCS) and photobleaching experiments to measure the effective number of molecules and the molecular brightness as a function of the total fluorescence count rate on solutions of cDNA (containing a few percent of C bases labeled with Alexa Fluor 647). Here, photobleaching is used as a control parameter to vary the experimental outputs (brightness and number of molecules). Assuming a Poissonian distribution of the number of fluorescent labels per cDNA, the FCS-photobleaching data could be easily fit to yield the mean number of fluorescent labels per cDNA strand (@ 2). This number could not be determined solely on the basis of the cDNA brightness, because of both the statistical distribution of the number of fluorescent labels and their unknown brightness when incorporated in cDNA. The statistical distribution of the number of fluorophores labeling cDNA was confirmed by analyzing the photon count distribution (with the cumulant method), which showed clearly that the brightness of cDNA strands varies from one molecule to the other.
△ Less
Submitted 1 March, 2010; v1 submitted 4 September, 2009;
originally announced September 2009.
-
Spatial fluorescence cross correlation spectroscopy by means of a spatial light modulator
Authors:
Yoann Blancquaert,
Jie Gao,
Jacques Derouard,
Antoine Delon
Abstract:
Spatial Fluorescence Cross Correlation Spectroscopy is a rarely investigated version of Fluorescence Correlation Spectroscopy, in which the fluorescence signals from different observation volumes are cross-correlated. In the reported experiments, two observation volumes, typically shifted by a few $μ$m, are produced, with a Spatial Light Modulator and two adjustable pinholes. We illustrated the…
▽ More
Spatial Fluorescence Cross Correlation Spectroscopy is a rarely investigated version of Fluorescence Correlation Spectroscopy, in which the fluorescence signals from different observation volumes are cross-correlated. In the reported experiments, two observation volumes, typically shifted by a few $μ$m, are produced, with a Spatial Light Modulator and two adjustable pinholes. We illustrated the feasibility and potentiality of this technique by: i) measuring molecular flows, in the range 0.2 - 1.5 $μ$m/ms, of so-lutions seeded with fluorescent nanobeads or rhodamine molecules (simulating active transport phenomenons); ii) investigating the permeability of the phospholipidic membrane of Giant Unilamellar Vesicles versus hydrophilic or hydrophobic molecules (in that case the laser spots were set on both sides of the membrane). Theoretical descriptions are proposed together with a discus-sion about Fluorescence Correlation Spectroscopy based, alternative methods.
△ Less
Submitted 13 June, 2008; v1 submitted 26 February, 2008;
originally announced February 2008.
-
Measurement of surface concentration of fluorophores using fluorescence fluctuation spectroscopy
Authors:
Antoine Delon,
Jacques Derouard,
Guillaume Delapierre,
Rodolphe Jaffiol
Abstract:
Fluorescence fluctuation spectroscopy is applied to study molecules, passing through a small observation volume, usually subjected to diffusive or convective motion in liquid phase. We suggest that such a technique could be used to measure the areal absolute concentration of fluorophores deposited on a substrate or imbedded in a thin film, with a resolution of a few micrometers. The principle is…
▽ More
Fluorescence fluctuation spectroscopy is applied to study molecules, passing through a small observation volume, usually subjected to diffusive or convective motion in liquid phase. We suggest that such a technique could be used to measure the areal absolute concentration of fluorophores deposited on a substrate or imbedded in a thin film, with a resolution of a few micrometers. The principle is to translate the solid substrate in front of a confocal fluorescence microscope objective and to record the subsequent fluctuations of the fluorescence intensity. The validity of this concept is investigated on model substrates (fluorescent microspheres) and DNA biochips.
△ Less
Submitted 12 December, 2007;
originally announced December 2007.