(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–5 of 5 results for author: Demichev, M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2404.08317  [pdf, other

    hep-ex physics.ins-det

    Technical Design Report of the Spin Physics Detector at NICA

    Authors: The SPD Collaboration, V. Abazov, V. Abramov, L. Afanasyev, R. Akhunzyanov, A. Akindinov, I. Alekseev, A. Aleshko, V. Alexakhin, G. Alexeev, L. Alimov, A. Allakhverdieva, A. Amoroso, V. Andreev, V. Andreev, E. Andronov, Yu. Anikin, S. Anischenko, A. Anisenkov, V. Anosov, E. Antokhin, A. Antonov, S. Antsupov, A. Anufriev, K. Asadova , et al. (392 additional authors not shown)

    Abstract: The Spin Physics Detector collaboration proposes to install a universal detector in the second interaction point of the NICA collider under construction (JINR, Dubna) to study the spin structure of the proton and deuteron and other spin-related phenomena using a unique possibility to operate with polarized proton and deuteron beams at a collision energy up to 27 GeV and a luminosity up to… ▽ More

    Submitted 28 May, 2024; v1 submitted 12 April, 2024; originally announced April 2024.

  2. arXiv:2006.01254  [pdf

    physics.ins-det hep-ex

    Radiation hardness of GaAs: Cr and Si sensors irradiated by electron beam

    Authors: U. Kruchonak, S. Abou El-Azm, K. Afanaciev, G. Chelkov, M. Demichev, M. Gostkin, A. Guskov, E. Firu, V. Kobets, A. Leyva, d, A. Nozdrin, S. Porokhovoy, A. Sheremetyeva, P. Smolyanskiy, A. Torres, A. Tyazhev, O. Tolbanov, N. Zamyatin, A. Zarubin, A. Zhemchugov

    Abstract: The interest in using the radiation detectors based on high resistive chromium-compensated GaAs (GaAs:Cr) in high energy physics and others applied fields has been growing steadily due to its numerous advantages over others classical materials. High radiation hardness at room temperature stands out and needs to be systematically investigated. In this paper an experimental study of the effect of 20… ▽ More

    Submitted 1 June, 2020; originally announced June 2020.

    Comments: Paper sent to journal "Nuclear Inst. and Methods in Physics Research, A"

    Journal ref: Nuclear Inst. and Methods in PhysicsResearch, A(2020)

  3. Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam

    Authors: H. Abramowicz, A. Abusleme, K. Afanaciev, Y. Benhammou, O. Borysov, M. Borysova, I. Bozovic- Jelisavcic, W. Daniluk, D. Dannheim, M. Demichev, K. Elsener, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, M. Hempelb, H. Henschel, M. Idzik, A. Ignatenkoc, A. Ishikawa, A. Joffe, G. Kacarevic, S. Kananov, O. Karachebanb , et al. (29 additional authors not shown)

    Abstract: A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi… ▽ More

    Submitted 25 October, 2019; v1 submitted 29 December, 2018; originally announced December 2018.

    Comments: 16 pages, 28 figures, Published in EPJC. Please note: Fig 16 in the published version us incorrect. The correct one appears in this replaced version

    Journal ref: Eur. Phys. J. C79 (2019) 579

  4. arXiv:1501.07852  [pdf, other

    physics.ins-det

    Alignment and resolution studies of a MARS scanner

    Authors: A. P. Butler, P. H. Butler, S. T. Bell, G. Chelkov, M. Demichev, A. Gongadze, S. Kotov, D. Kozhevnikov, U. Kruchonak, I. Potrap, P. Smolyanskiy, A. Zhemchugov

    Abstract: The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an investigated sample using a set of shadow projections obtained for different angles. Projections in the MARS scanner are produced using a cone x-ray beam geometry. Correct reconstruction in this scheme requires precise… ▽ More

    Submitted 23 March, 2015; v1 submitted 29 January, 2015; originally announced January 2015.

  5. Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip

    Authors: A. P. Butler, P. H. Butler, S. T. Bell, G. A. Chelkov, D. V. Dedovich, M. A. Demichev, V. G. Elkin, M. I. Gostkin, S. A. Kotov, D. A. Kozhevnikov, U. G. Kruchonak, A. A. Nozdrin, S. Yu. Porokhovoy, I. N. Potrap, P. I. Smolyanskiy, M. M. Zakhvatkin, A. S. Zhemchugov

    Abstract: This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with the resolution and the efficiency of the pixel detector is used for the calibration. The energy resolution of the detector is also measured during the calibratio… ▽ More

    Submitted 14 January, 2015; originally announced January 2015.