Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (294 additional authors not shown)
Abstract:
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout t…
▽ More
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of >10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of >8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within $\pm$(0.1-0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.
△ Less
Submitted 26 August, 2024;
originally announced August 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Long-term temporal stability of the DarkSide-50 dark matter detector
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time project…
▽ More
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.
△ Less
Submitted 22 May, 2024; v1 submitted 30 November, 2023;
originally announced November 2023.
-
Directionality of nuclear recoils in a liquid argon time projection chamber
Authors:
The DarkSide-20k Collaboration,
:,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
M. Ave,
I. Ch. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado-Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
V. Bocci,
W. M. Bonivento,
B. Bottino,
M. G. Boulay,
J. Busto,
M. Cadeddu
, et al. (243 additional authors not shown)
Abstract:
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scint…
▽ More
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence level
△ Less
Submitted 28 July, 2023;
originally announced July 2023.
-
Investigation of radiation hardness of silicon semiconductor detectors under irradiation with fission products of 252Cf nuclide
Authors:
N. V. Bazlov,
A. V. Derbin,
I. S. Drachnev,
I. M. Kotina,
O. I. Konkov,
I. S. Lomskaya,
M. S. Mikulich,
V. N. Muratova,
D. A. Semenov,
M. V. Trushin,
E. V. Unzhakov
Abstract:
Influence of the prolonged irradiation by fission products of 252Cf radionuclide on the operational parameters of silicon-lithium Si(Li) p-i-n detectors, Si surface barrier detectors and Si planar p+n detector was investigated. The obtained results revealed a linear shift of the fission fragment peaks positions towards the lower energies with increase of the irradiation dose for all investigated d…
▽ More
Influence of the prolonged irradiation by fission products of 252Cf radionuclide on the operational parameters of silicon-lithium Si(Li) p-i-n detectors, Si surface barrier detectors and Si planar p+n detector was investigated. The obtained results revealed a linear shift of the fission fragment peaks positions towards the lower energies with increase of the irradiation dose for all investigated detectors. The rate of the peaks shift was found to depend strongly on the detector type and the strength of the electric field in the detectors active region, but not on the temperature of irradiation (room or liquid nitrogen temperature). Based on the obtained results, the possibility of integration of the investigated types of Si semiconductor detectors in a radionuclide neutron calibration source is considered.
△ Less
Submitted 13 January, 2023;
originally announced January 2023.
-
Silicon $4π$ spectrometer for $β$-decay electrons with energies up to 3~MeV
Authors:
I. E. Alexeev,
S. V. Bakhlanov,
E. A. Chmel,
A. V. Derbin,
I. S. Drachnev,
I. M. Kotina,
M. S. Mikulich,
V. N. Muratova,
N. V. Nyazova,
D. A. Semenov,
M. V. Trushin,
E. V. Unzhakov
Abstract:
We present a description of the originally developed $β$-spectrometer consisting of two Si(Li)-detectors with sensitive area thickness above 8~mm and $4π$-geometry. The full absorption spectrometer allows for direct measurements of $β$-spectra, disregarding the corrections to the response function induced by the electron backscattering from the crystal surface. In case of $β$-spectra of transition…
▽ More
We present a description of the originally developed $β$-spectrometer consisting of two Si(Li)-detectors with sensitive area thickness above 8~mm and $4π$-geometry. The full absorption spectrometer allows for direct measurements of $β$-spectra, disregarding the corrections to the response function induced by the electron backscattering from the crystal surface. In case of $β$-spectra of transitions to the excited state of the daughter isotope additional 3" BGO-detector is used in order to detect the $γ$-quanta in coincidence with the pair of Si(Li)-spectrometers.
△ Less
Submitted 21 October, 2022;
originally announced October 2022.
-
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Authors:
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. Ch. Avetisov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
E. Berzin,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino
, et al. (274 additional authors not shown)
Abstract:
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu…
▽ More
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino floor for GeV-scale masses and significant sensitivity down to 10 MeV/c$^2$ considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector's sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.
△ Less
Submitted 20 June, 2023; v1 submitted 2 September, 2022;
originally announced September 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
Authors:
The DarkSide collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella,
P. Cavalcante
, et al. (114 additional authors not shown)
Abstract:
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionizat…
▽ More
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to $\sim$180~eV$_{er}$, exploiting $^{37}$Ar and $^{39}$Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present a model-dependent determination of the ionization response to nuclear recoils down to $\sim$500~eV$_{nr}$, the lowest ever achieved in liquid argon, using \textit{in situ} neutron calibration sources and external datasets from neutron beam experiments.
△ Less
Submitted 15 September, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (114 additional authors not shown)
Abstract:
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-5…
▽ More
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all kind of observed events, is essential for an optimal design of the new experiment. In this paper, we report on a particular set of events, which were not used for dark matter searches. Namely, standard two-pulse scintillation-ionization signals accompanied by a small amplitude third pulse, originating from single or few electrons, in a time window of less than a maximum drift time. We compare our findings to those of a recent paper of the LUX Collaboration (D.S.Akerib et al. Phys.Rev.D 102, 092004). Indeed, both experiments observe events related to photoionization of the cathode. From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths around 128 nm, in liquid argon. Also, both experiments observe events likely related to photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be one order of magnitude smaller in DarkSide-50 than in LUX. This result, together with the much larger measured electron lifetime, coherently hints toward a lower concentration of contaminants in DarkSide-50 than in LUX.
△ Less
Submitted 27 November, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Separating $^{39}$Ar from $^{40}$Ar by cryogenic distillation with Aria for dark matter searches
Authors:
DarkSide Collaboration,
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
M. Arba,
P. Arpaia,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova
, et al. (287 additional authors not shown)
Abstract:
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopi…
▽ More
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopic abundance of $^{39}$Ar, a $β$-emitter of cosmogenic origin, whose activity poses background and pile-up concerns in the detectors, in the argon used for the dark-matter searches, the so-called Underground Argon (UAr). In this paper, we discuss the requirements, design, construction, tests, and projected performance of the plant for the isotopic cryogenic distillation of argon. We also present the successful results of isotopic cryogenic distillation of nitrogen with a prototype plant, operating the column at total reflux.
△ Less
Submitted 23 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Influence of α-particles irradiation on the performance and defect levels structure of Al/SiO2/p-type Si surface barrier detector
Authors:
S. V. Bakhlanov,
N. V. Bazlov,
D. V. Danilov,
A. V. Derbin,
I. S. Drachnev,
I. M. Kotina,
O. I. Konkov,
A. M. Kuzmichev,
M. S. Mikulich,
V. N. Muratova,
M. V. Trushin,
E. V. Unzhakov
Abstract:
Deterioration of the operation parameters of Al/SiO2/p-type Si surface barrier detector upon irradiation with alpha-particles at room temperature was investigated. As a result of 40-days irradiation with a total fluence of 8*10^9 α-particles, an increase of α-peak FWHM from 70 keV to 100 keV was observed and explained by increase of the detector reverse current due to formation of a high concentra…
▽ More
Deterioration of the operation parameters of Al/SiO2/p-type Si surface barrier detector upon irradiation with alpha-particles at room temperature was investigated. As a result of 40-days irradiation with a total fluence of 8*10^9 α-particles, an increase of α-peak FWHM from 70 keV to 100 keV was observed and explained by increase of the detector reverse current due to formation of a high concentration of near mid-gap defect levels. Performed CV measurements revealed the appearance of at least 6*10^12 cm-3 radiation-induced acceptors at the depths where according to the TRIM simulations the highest concentration of vacancy-interstitial pairs was created by the incoming α-particles. The studies carried out by current-DLTS technique allowed to associate the observed increase of the acceptor concentration with the near mid-gap acceptor level at EV+0.56 eV. This level can be apparently associated with V2O defects recognized previously to be responsible for the space charge sign inversion in the irradiated n-type Si detectors.
△ Less
Submitted 11 January, 2021;
originally announced January 2021.
-
Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos
Authors:
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino,
M. G. Boulay,
G. Buccino
, et al. (251 additional authors not shown)
Abstract:
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and AR…
▽ More
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and ARGO, respectively.
Thanks to the low-energy threshold of $\sim$0.5~keV$_{nr}$ achievable by exploiting the ionization channel, DarkSide-20k and ARGO have the potential to discover supernova bursts throughout our galaxy and up to the Small Magellanic Cloud, respectively, assuming a 11-M$_{\odot}$ progenitor star. We report also on the sensitivity to the neutronization burst, whose electron neutrino flux is suppressed by oscillations when detected via charged current and elastic scattering. Finally, the accuracies in the reconstruction of the average and total neutrino energy in the different phases of the supernova burst, as well as its time profile, are also discussed, taking into account the expected background and the detector response.
△ Less
Submitted 31 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
Precision measurement of $^{\mathbf{210}}$Bi $β$-spectrum
Authors:
I. E. Alekseev,
S. V. Bakhlanov,
A. V. Derbin,
I. S. Drachnev,
I. M. Kotina,
I. S. Lomskaya,
V. N. Muratova,
N. V. Niyazova,
D. A. Semenov,
M. V. Trushin,
E. V. Unzhakov
Abstract:
The precision measurement of the $β-$spectrum shape for $^{210}$Bi (historically RaE) have been performed with a spectrometer based on semiconductor Si(Li) detector. This first forbidden non-unique transition has the transition form-factor strongly deviated from unity and knowledge of its spectrum would play an important role in low-background physics in presence of $^{210}$Pb background. The meas…
▽ More
The precision measurement of the $β-$spectrum shape for $^{210}$Bi (historically RaE) have been performed with a spectrometer based on semiconductor Si(Li) detector. This first forbidden non-unique transition has the transition form-factor strongly deviated from unity and knowledge of its spectrum would play an important role in low-background physics in presence of $^{210}$Pb background. The measured transition form-factor could be approximated as $S(W) = 1 + (-0.4363 \pm 0.0037) W + (0.0523 \pm 0.0010) W^2$, that is in good agreement with previous studies and has significantly increased parameter precision.
△ Less
Submitted 11 January, 2021; v1 submitted 18 May, 2020;
originally announced May 2020.
-
New limits on the resonant absorption of solar axions obtained with a $^{169}$Tm-containing cryogenic detector
Authors:
A. H. Abdelhameed,
S. V. Bakhlanov,
P. Bauer,
A. Bento,
E. Bertoldo,
L. Canonica,
A. V. Derbin,
I. S. Drachnev,
N. Ferreiro Iachellini,
D. Fuchs,
D. Hauff,
M. Laubenstein,
D. A. Lis,
I. S. Lomskaya,
M. Mancuso,
V. N. Muratova,
S. Nagorny,
S. Nisi,
F. Petricca,
F. Proebst,
J. Rothe,
V. V. Ryabchenkov,
S. E. Sarkisov,
D. A. Semenov,
K. A. Subbotin
, et al. (3 additional authors not shown)
Abstract:
A search for resonant absorption of solar axions by $^{169}$Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on Tm$_3$Al$_5$O$_{12}$ crystal was used that allowed for significant improvement of sensitivity in comparison with previous $^{169}$Tm based experiments. The measurements performed with $8.18$ g crystal during $6.6$ days exposure yiel…
▽ More
A search for resonant absorption of solar axions by $^{169}$Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on Tm$_3$Al$_5$O$_{12}$ crystal was used that allowed for significant improvement of sensitivity in comparison with previous $^{169}$Tm based experiments. The measurements performed with $8.18$ g crystal during $6.6$ days exposure yielded the following limits on axion couplings: $|g_{Aγ} (g_{AN}^0 + g_{AN}^3) \leq 1.44 \times 10^{-14}$ GeV$^{-1}$ and $|g_{Ae} (g_{AN}^0 + g_{AN}^3) \leq 2.81 \times 10^{-16}$.
△ Less
Submitted 17 April, 2020;
originally announced April 2020.
-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
Effective field theory interactions for liquid argon target in DarkSide-50 experiment
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli
, et al. (143 additional authors not shown)
Abstract:
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper…
▽ More
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between $2.4 \times 10^{-45} \, \mathrm{cm}^2$ and $2.3 \times 10^{-42} \, \mathrm{cm}^2$ (8.9 $\times 10^{-45} \, \mathrm{cm}^2$ and 6.0 $\times 10^{-42} \, \mathrm{cm}^2$) for WIMPs of mass of 100 $\mathrm{GeV/c^2}$ (1000 $\mathrm{GeV/c^2}$) at 90\% confidence level.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (141 additional authors not shown)
Abstract:
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)…
▽ More
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
△ Less
Submitted 28 October, 2019; v1 submitted 22 July, 2019;
originally announced July 2019.
-
A Test of Bolometric Properties of Tm-containing Crystals as a Perspective Detector for the Solar Axion Search
Authors:
E. Bertoldo,
A. V. Derbin,
I. S. Drachnev,
M. Laubenstein,
D. A. Lis,
M. Mancuso,
V. N. Muratova,
S. Nagorny,
S. Nisi,
F. Petricca,
V. V. Ryabchenkov,
S. E. Sarkisov,
D. A. Semenov,
K. A. Subbotin,
E. V. Unzhakov,
E. V. Zharikov
Abstract:
The $^{169}$Tm nuclide has first nuclear level at 8.41 keV with magnetic type transition to the ground state and, therefore, can be used as a target nucleus for the search of resonant absorption of solar axions. We plan to use a Tm-containing crystal of a garnet family Tm$_3$Al$_5$O$_{12}$ as a bolometric detector in order to search for the excitation of the first nuclear level of $^{169}$Tm via t…
▽ More
The $^{169}$Tm nuclide has first nuclear level at 8.41 keV with magnetic type transition to the ground state and, therefore, can be used as a target nucleus for the search of resonant absorption of solar axions. We plan to use a Tm-containing crystal of a garnet family Tm$_3$Al$_5$O$_{12}$ as a bolometric detector in order to search for the excitation of the first nuclear level of $^{169}$Tm via the resonant absorption of solar axions. With this perspective in mind, a sample of the Tm$_3$Al$_5$O$_{12}$ crystal was grown and tested for its bolometric and optical properties. Measurements of chemical and/or radioactive contaminations were performed as well. In this paper we present the test results and estimate the requirements for a future low-background experimental setup.
△ Less
Submitted 30 May, 2019;
originally announced May 2019.
-
Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
M. P. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (141 additional authors not shown)
Abstract:
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs…
▽ More
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.
△ Less
Submitted 23 July, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
Measurement of $^{144}\rm{Pr}$ beta-spectrum with Si(Li) detectors for the purpose of determining the spectrum of electron antineutrinos
Authors:
A. V. Derbin,
S. V. Bakhlanov,
I. S. Drachnev,
I. P. Filipov,
L. A. Lukyanchenko,
I. N. Machulin,
V. N. Muratova,
N. V. Pilipenko,
D. A. Semenov,
E. V. Unzhakov
Abstract:
Here we present the specifications of the newly developed beta-spectrometer based on thick full absorption Si(Li) detector. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of $^{144}$Pr, which is considered to be the most promising anti-neutrino source for sterile neutrino searches.
Here we present the specifications of the newly developed beta-spectrometer based on thick full absorption Si(Li) detector. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of $^{144}$Pr, which is considered to be the most promising anti-neutrino source for sterile neutrino searches.
△ Less
Submitted 19 November, 2017;
originally announced November 2017.
-
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
S. Catalanotti,
V. Cataudella
, et al. (125 additional authors not shown)
Abstract:
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination techni…
▽ More
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.
△ Less
Submitted 26 September, 2017; v1 submitted 18 July, 2017;
originally announced July 2017.
-
Cryogenic Characterization of FBK RGB-HD SiPMs
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Ampudia,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
H. O. Back,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
R. Bunker
, et al. (246 additional authors not shown)
Abstract:
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio…
▽ More
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300 K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a few Hz/mm$^2$.
△ Less
Submitted 12 September, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.
-
A measurement method of a detector response function for monochromatic electrons based on the Compton scattering
Authors:
S. V. Bakhlanov,
N. V. Bazlov,
A. V. Derbin,
I. S. Drachnev,
A. S. Kayunov,
V. N. Muratova,
D. A. Semenov,
E. V. Unzhakov
Abstract:
In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arran…
▽ More
In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arranged adjacent to each other. The method presents an effective solution for the detectors consisting of a low atomic number materials, when the ratio between Compton effect and photoelectric absorption is large and the mean path of gamma-rays is comparable to the size of the detector. The technique can be used for the precision measurements of the scintillator light yield dependence on the electron energy.
△ Less
Submitted 13 April, 2016;
originally announced April 2016.
-
Searches for axioelectric effect of solar axions with BGO-scintillator and BGO-bolometer detectors
Authors:
V. N. Muratova,
A. V. Derbin,
L. Gironi,
S. S Nagorny,
L. Pattavina,
S. V. Bakhlanov,
J. W. Beeman,
F. Bellini,
M. Biassoni,
S. Capelli,
M. Clemenza,
I. S. Dratchnev,
E. Ferri,
A. Giachero,
C. Gotti,
A. S. Kayunov,
C. Maiano,
M. Maino,
M. Pavan,
S. Pirro,
D. A. Semenov,
M. Sisti,
E. V. Unzhakov
Abstract:
A search for axioelectric absorption of 5.5 MeV solar axions produced in the $p + d \rightarrow {^3\rm{He}}+γ~(5.5~ \rm{MeV})$ reaction has been performed with a BGO detectors. A model-independent limit on the product of axion-nucleon $g_{AN}^3$ and axion-electron $g_{Ae}$ coupling constants has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90\% C.L..
A search for axioelectric absorption of 5.5 MeV solar axions produced in the $p + d \rightarrow {^3\rm{He}}+γ~(5.5~ \rm{MeV})$ reaction has been performed with a BGO detectors. A model-independent limit on the product of axion-nucleon $g_{AN}^3$ and axion-electron $g_{Ae}$ coupling constants has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90\% C.L..
△ Less
Submitted 14 January, 2015; v1 submitted 13 January, 2015;
originally announced January 2015.
-
First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter
Authors:
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. V. Derbin,
V. V. Kazalov,
H. J. Kim,
Y. D. Kim,
V. V. Kobychev,
V. V. Kuzminov,
Luqman Ali,
V. N. Muratova,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Semenov,
D. A. Tekueva,
S. P. Yakimenko,
E. V. Unzhakov
Abstract:
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the…
▽ More
The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Conceptual Design of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
F. T. Avignone,
M. Betz,
P. Brax,
P. Brun,
G. Cantatore,
J. M. Carmona,
G. P. Carosi,
F. Caspers,
S. Caspi,
S. A. Cetin,
D. Chelouche,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
B. Döbrich,
I. Dratchnev,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas
, et al. (63 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc…
▽ More
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
IAXO - The International Axion Observatory
Authors:
J. K. Vogel,
F. T. Avignone,
G. Cantatore,
J. M. Carmona,
S. Caspi,
S. A. Cetin,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
J. G. Garza,
T. Geralis,
B. Gimeno,
I. Giomataris,
S. Gninenko,
H. Gomez
, et al. (39 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f…
▽ More
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic field volume together with the extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested at CAST. Electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) along with other novel excitations at the low-energy frontier of elementary particle physics could provide additional physics motivation for IAXO.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector
Authors:
RED Collaboration,
D. Yu. Akimov,
I. S. Alexandrov,
V. I. Aleshin,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. S. Chepurnov,
M. V. Danilov,
A. V. Derbin,
V. V. Dmitrenko,
A. G. Dolgolenko,
D. A. Egorov,
Yu. V. Efremenko,
A. V. Etenko,
M. B. Gromov,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kantserov,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin
, et al. (21 additional authors not shown)
Abstract:
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites…
▽ More
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites have advantages as well as limitations. However the experiment looks feasible at either location. Preliminary design of the detector and supporting R&D program are discussed.
△ Less
Submitted 9 December, 2012;
originally announced December 2012.
-
Search for neutrino oscillations at a research reactor
Authors:
A. V. Derbin,
A. S. Kayunov,
V. N. Muratova
Abstract:
A project of search for oscillations of reactor neutrinos on a short, 5 - 15 meters, baseline with liquid scintillation position-sensitive detector POSEIDON is described. The oscillations of the electron antineutrinos into sterile neutrinos will be searched at 100 MW research reactor with the size of the active zone of about 0.5 m. The values of the oscillation parameters available for research ar…
▽ More
A project of search for oscillations of reactor neutrinos on a short, 5 - 15 meters, baseline with liquid scintillation position-sensitive detector POSEIDON is described. The oscillations of the electron antineutrinos into sterile neutrinos will be searched at 100 MW research reactor with the size of the active zone of about 0.5 m. The values of the oscillation parameters available for research are in the region $δm^2 = (0.3 - 6) \rm{eV}^2$ and $\rm{Sin}^2(2θ)\geq 0.01$.
△ Less
Submitted 11 April, 2012;
originally announced April 2012.
-
On the possiblity of detecting Solar pp-neutrino with a large volume liquid organic scintillator detector
Authors:
A. V. Derbin,
O. Yu. Smirnov,
O. A. Zaimidoroga
Abstract:
It is shown that a large volume liquid organic scintillator detector with an energy resolution of 10 keV at 200 keV 1 sigma will be sensitive to solar pp-neutrino, if operated at the target radiopurity levels for the Borexino detector, or the solar neutrino project of KamLAND.
It is shown that a large volume liquid organic scintillator detector with an energy resolution of 10 keV at 200 keV 1 sigma will be sensitive to solar pp-neutrino, if operated at the target radiopurity levels for the Borexino detector, or the solar neutrino project of KamLAND.
△ Less
Submitted 3 March, 2004;
originally announced March 2004.