-
Hard X-ray grazing incidence ptychography: Large field-of-view nanostructure imaging with ultra-high surface sensitivity
Authors:
P. S. Jørgensen,
L. Besley,
A. M. Slyamov,
A. Diaz,
M. Guizar-Sicairos,
M. Odstrcil,
M. Holler,
C. Silvestre,
B. Chang,
C. Detlefs,
J. W. Andreasen
Abstract:
We demonstrate a technique that allows highly surface sensitive imaging of nanostructures on planar surfaces over large areas, providing a new avenue for research in materials science, especially for \textit{in situ} applications. The capabilities of hard X-ray grazing incidence ptychography combine aspects from imaging, reflectometry and grazing incidence small angle scattering in providing large…
▽ More
We demonstrate a technique that allows highly surface sensitive imaging of nanostructures on planar surfaces over large areas, providing a new avenue for research in materials science, especially for \textit{in situ} applications. The capabilities of hard X-ray grazing incidence ptychography combine aspects from imaging, reflectometry and grazing incidence small angle scattering in providing large field-of-view images with high resolution transverse to the beam, horizontally and along the surface normal. Thus, it yields data with resolutions approaching electron microscopy, in two dimensions, but over much larger areas and with a poorer resolution in the third spatial dimension, along the beam propagation direction. Similar to grazing incidence small angle X-ray scattering, this technique facilitates the characterization of nanostructures across statistically significant surface areas or volumes within potentially feasible time frames for \textit{in situ} experiments, while also providing spatial information.
△ Less
Submitted 4 July, 2023;
originally announced July 2023.
-
Tilting refractive x-ray lenses for fine-tuning their focal length
Authors:
Rafael Celestre,
Thomas Roth,
Carsten Detlefs,
Peng Qi,
Marco Cammarata,
Manuel Sanchez del Rio,
Raymond Barrett
Abstract:
In this work, we measure and model tilted x-ray refractive lenses to investigate their effects on an x-ray beam. The modelling is benchmarked against at-wavelength metrology obtained with x-ray speckle vector tracking experiments (XSVT) at the BM05 beamline at the ESRF-EBS light source, showing very good agreement. This validation permits us to explore possible applications of tilted x-ray lenses…
▽ More
In this work, we measure and model tilted x-ray refractive lenses to investigate their effects on an x-ray beam. The modelling is benchmarked against at-wavelength metrology obtained with x-ray speckle vector tracking experiments (XSVT) at the BM05 beamline at the ESRF-EBS light source, showing very good agreement. This validation permits us to explore possible applications of tilted x-ray lenses in optical design: we demonstrate that tilting 1D lenses around their focusing direction can be used for fine-tuning their focal length with possible applications in beamline optical design.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Identification of coherent twin relationship from high-resolution reciprocal space maps
Authors:
Semen Gorfman,
David Spirito,
Guanjie Zhang,
Carsten Detlefs,
Nan Zhang
Abstract:
Twinning is a common crystallographic phenomenon, which usually occurs in crystals during symmetry-lowering phase transition. Once formed, twin domains play an important role in defining physical properties: for example, twin domains underpin the giant piezoelectric effect in ferroelectrics, superelasticity in ferroelastics and the shape-memory effect in martensitic alloys. Unfortunately, there is…
▽ More
Twinning is a common crystallographic phenomenon, which usually occurs in crystals during symmetry-lowering phase transition. Once formed, twin domains play an important role in defining physical properties: for example, twin domains underpin the giant piezoelectric effect in ferroelectrics, superelasticity in ferroelastics and the shape-memory effect in martensitic alloys. Unfortunately, there is still a lack of experimental methods for imaging and characterization of twin domain patterns. Here, we propose a theoretical framework and an algorithm for the recognition of twinned pairs of ferroelastic domains and the identification of the coherent twin relationship using high-resolution reciprocal space mapping of X-ray diffraction intensity around split Bragg peaks. Specifically, we adapt the geometrical theory of twinned ferroelastic crystals (Fousek & Janovec, 1969) for the analysis of the X-ray diffraction patterns. We derive the necessary equations and outline an algorithm for calculation of the separation between the Bragg peaks, diffracted from possible coherent twin domains, connected to one another via mismatch-free interface. We demonstrate that such separation is always perpendicular to the planar interface between mechanically matched domains. As examples, we present the analysis of the separation between the peaks diffracted from tetragonal and rhombohedral domains in the high-resolution reciprocal space maps of BaTiO3 and PbZr1-xTixO3 crystals. The demonstrated method can be used to analyse the response of multi-domain patterns to external perturbations such as electric field, change of a temperature or pressure.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
Geometrical Optics Formalism to Model Contrast in Dark-Field X-ray Microscopy
Authors:
H. F. Poulsen,
L. E. Dresselhaus-Marais,
M. A. Carlsen,
C. Detlefs,
G. Winther
Abstract:
Dark-field X-ray microscopy is a new full-field imaging technique that nondestructively maps the structure and local strain inside deeply embedded crystalline elements in three dimensions. Placing an objective lens in the diffracted beam generates a magnified projection image of a local volume. We provide a general formalism based on geometrical optics for the diffraction imaging, valid for any cr…
▽ More
Dark-field X-ray microscopy is a new full-field imaging technique that nondestructively maps the structure and local strain inside deeply embedded crystalline elements in three dimensions. Placing an objective lens in the diffracted beam generates a magnified projection image of a local volume. We provide a general formalism based on geometrical optics for the diffraction imaging, valid for any crystallographic space group. This allows simulation of diffraction images based on micro-mechanical models. We present example simulations with the formalism, demonstrating how it may be used to design new experiments or interpret existing ones. In particular, we show how modifications to the experimental design may tailor the reciprocal-space resolution function to map specific components of the deformation gradient tensor. The formalism supports multi-length scale experiments, as it enables DFXM to be interfaced with 3DXRD. The formalism is demonstrated by comparison to experimental images of the strain field around a straight dislocation.
△ Less
Submitted 18 July, 2020;
originally announced July 2020.
-
Mirror Furnace for Synchrotron Dark Field X-ray Microscopy Experiments
Authors:
C. Yildirim,
H. Vitoux,
L. E. Dresselhaus-Cooper,
R. Steinmann,
Y. Watier,
P. K. Cook,
M. Kutsal,
C. Detlefs
Abstract:
We present a multi-purpose mirror furnace designed for synchrotron X-ray experiments. The furnace is optimized specifically for dark-field X-ray microscopy (DFXM) of crystalline materials at the beamline ID06 of the ESRF. The furnace can reach up to ~1600°C with stability better than 2°C, and heating and cooling rates up to 30°C/s. The contact-less design enables samples to be heated either in air…
▽ More
We present a multi-purpose mirror furnace designed for synchrotron X-ray experiments. The furnace is optimized specifically for dark-field X-ray microscopy (DFXM) of crystalline materials at the beamline ID06 of the ESRF. The furnace can reach up to ~1600°C with stability better than 2°C, and heating and cooling rates up to 30°C/s. The contact-less design enables samples to be heated either in air or in a controlled atmosphere in a capillary tube. The temperature was calibrated via the thermal expansion of an a-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the furnace. In the current configuration of the beamline, the furnace can be used for DFXM, near-field X-ray topography, bright field X-ray nanotomography, high resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure Al single crystal.
△ Less
Submitted 3 December, 2019;
originally announced December 2019.
-
Translative lens-based full field coherent X-ray imaging
Authors:
Carsten Detlefs,
Mario A. Beltran,
Jean-Pierre Guigay,
Hugh Simons
Abstract:
We describe a full-field coherent imaging approach suitable for hard X-rays based on a classical (i.e. Galilean) X-ray microscope. The method combines a series of low-resolution images acquired at different transverse lens positions into a single high-resolution image, overcoming the spatial resolution limit set by the numerical aperture of the objective lens. We describe the optical principles of…
▽ More
We describe a full-field coherent imaging approach suitable for hard X-rays based on a classical (i.e. Galilean) X-ray microscope. The method combines a series of low-resolution images acquired at different transverse lens positions into a single high-resolution image, overcoming the spatial resolution limit set by the numerical aperture of the objective lens. We describe the optical principles of the approach, demonstrate the successful reconstruction of simulated phantom data, and discuss aspects of the reconstruction. We believe this approach offers some potential benefits over conventional scanning X-ray ptychography in terms of acquisition speed, spatial bandwidth and radiation dose rate.
△ Less
Submitted 6 May, 2019;
originally announced May 2019.
-
X-ray coherent diffraction imaging with an objective lens: towards 3D mapping of thick polycrystals
Authors:
Anders Filsøe Pedersen,
Virginie Chamard,
Carsten Detlefs,
Tao Zhou,
Dina Carbone,
Henning Friis Poulsen
Abstract:
We report on a new x-ray imaging method, which combines the high spatial resolution of coherent diffraction imaging with the ability of dark field microscopy to map grains within thick polycrystalline specimens. An x-ray objective serves to isolate a grain and avoid overlap of diffraction spots. Iterative oversampling routines are used to reconstruct the shape and strain field within the grain fro…
▽ More
We report on a new x-ray imaging method, which combines the high spatial resolution of coherent diffraction imaging with the ability of dark field microscopy to map grains within thick polycrystalline specimens. An x-ray objective serves to isolate a grain and avoid overlap of diffraction spots. Iterative oversampling routines are used to reconstruct the shape and strain field within the grain from the far field intensity pattern. The limitation on resolution caused by the finite numerical aperture of the objective is overcome by the Fourier synthesis of several diffraction patterns. We demonstrate the method by an experimental study of a ~500 nm Pt grain for the two cases of a real and a virtual image plane. In the latter case the spatial resolution is 13 nm rms. Our results confirm that no information on the pupil function of the lens is required and that lens aberrations are not critical.
△ Less
Submitted 31 August, 2018;
originally announced October 2018.
-
X-ray Fourier ptychographic microscopy
Authors:
H. Simons,
H. F. Poulsen,
J. P. Guigay,
C. Detlefs
Abstract:
Following the recent developement of Fourier ptychographic microscopy (FPM) in the visible range by Zheng et al. (2013), we propose an adaptation for hard x-rays. FPM employs ptychographic reconstruction to merge a series of low-resolution, wide field of view images into a high-resolution image. In the x-ray range this opens the possibility to overcome the limited numerical aperture of existing x-…
▽ More
Following the recent developement of Fourier ptychographic microscopy (FPM) in the visible range by Zheng et al. (2013), we propose an adaptation for hard x-rays. FPM employs ptychographic reconstruction to merge a series of low-resolution, wide field of view images into a high-resolution image. In the x-ray range this opens the possibility to overcome the limited numerical aperture of existing x-ray lenses. Furthermore, digital wave front correction (DWC) may be used to charaterize and correct lens imperfections. Given the diffraction limit achievable with x-ray lenses (below 100 nm), x-ray Fourier ptychographic microscopy (XFPM) should be able to reach resolutions in the 10 nm range.
△ Less
Submitted 22 September, 2016;
originally announced September 2016.
-
Extended formalism for simulating compound refractive lens-based x-ray microscopes
Authors:
Hugh Simons,
Sonja Rosenlund Ahl,
Henning Friis Poulsen,
Carsten Detlefs
Abstract:
We present a comprehensive formalism for the simulation and optimisation of CRLs in both condensing and full-field imaging configurations. The approach extends ray transfer matrix analysis to account for x-ray attenuation by the lens material. Closed analytical expressions for critical imaging parameters such as numerical aperture, vignetting, chromatic aberration and focal length are provided for…
▽ More
We present a comprehensive formalism for the simulation and optimisation of CRLs in both condensing and full-field imaging configurations. The approach extends ray transfer matrix analysis to account for x-ray attenuation by the lens material. Closed analytical expressions for critical imaging parameters such as numerical aperture, vignetting, chromatic aberration and focal length are provided for both thin- and thick-lens imaging geometries.
△ Less
Submitted 8 February, 2016;
originally announced February 2016.
-
Full-field hard x-ray microscopy with interdigitated silicon lenses
Authors:
Hugh Simons,
Frederik Stöhr,
Jonas Michael-Lindhard,
Flemming Jensen,
Ole Hansen,
Carsten Detlefs,
Henning Friis Poulsen
Abstract:
Full-field x-ray microscopy using x-ray objectives has become a mainstay of the biological and materials sciences. However, the inefficiency of existing objectives at x-ray energies above 15 keV has limited the technique to weakly absorbing or two-dimensional (2D) samples. Here, we show that significant gains in numerical aperture and spatial resolution may be possible at hard x-ray energies by us…
▽ More
Full-field x-ray microscopy using x-ray objectives has become a mainstay of the biological and materials sciences. However, the inefficiency of existing objectives at x-ray energies above 15 keV has limited the technique to weakly absorbing or two-dimensional (2D) samples. Here, we show that significant gains in numerical aperture and spatial resolution may be possible at hard x-ray energies by using silicon-based optics comprising 'interdigitated' refractive silicon lenslets that alternate their focus between the horizontal and vertical directions. By capitalizing on the nano-manufacturing processes available to silicon, we show that it is possible to overcome the inherent inefficiencies of silicon-based optics and interdigitated geometries. As a proof-of-concept of Si-based interdigitated objectives, we demonstrate a prototype interdigitated lens with a resolution of ~255 nm at 17 keV.
△ Less
Submitted 22 June, 2015;
originally announced June 2015.
-
Crystallographic investigation of Au nanoparticles embedded in a SrTiO$_3$ thin film for plasmonics applications by means of synchrotron radiation
Authors:
Davide Pincini,
Claudio Mazzoli,
Hendrik Bernhardt,
Christian Katzer,
Frank Schimdl,
Ingo Uschmann,
Carsten Detlefs
Abstract:
Self-organized monocrystalline Au nanoparticles with potential applications in plasmonics are grown in a SrTiO$_3$ matrix by a novel two-step deposition process. The crystalline preferred orientation of these Au nanoparticles is investigated by synchrotron hard x-ray diffraction. Nanoparticles preferentially align with the (111) direction along the substrate normal (001), whereas two in-plane orie…
▽ More
Self-organized monocrystalline Au nanoparticles with potential applications in plasmonics are grown in a SrTiO$_3$ matrix by a novel two-step deposition process. The crystalline preferred orientation of these Au nanoparticles is investigated by synchrotron hard x-ray diffraction. Nanoparticles preferentially align with the (111) direction along the substrate normal (001), whereas two in-plane orientations are found with $[110]_{SrTiO_3} \: || \: [110]_{Au}$ and $[100]_{SrTiO_3} \: || \: [110]_{Au}$. Additionally, a smaller diffraction signal from nanoparticles with the (001) direction parallel to the substrate normal (001) is observed; once again, two in-plane orientations are found, with $[100]_{SrTiO_3} \: || \: [100]_{Au}$ and $[100]_{SrTiO_3} \: || \: [110]_{Au}$. The populations of the two in-plane orientations are found to depend on the thickness of the gold film deposited in the first step of the growth.
△ Less
Submitted 20 November, 2014;
originally announced November 2014.
-
X-ray diffraction microscopy based on refractive optics
Authors:
Thomas Roth,
Carsten Detlefs,
Irina Snigireva,
Anatoly Snigirev
Abstract:
We describe a diffraction microscopy technique based on refractive optics to study structural variations in crystals. The X-ray beam diffracted by a crystal was magnified by beryllium parabolic refractive lenses on a 2D X-ray camera. The microscopy setup was integrated into the 6-circle Huber diffractometer at the ESRF beamline ID06. Our setup allowed us to visualize structural imperfections with…
▽ More
We describe a diffraction microscopy technique based on refractive optics to study structural variations in crystals. The X-ray beam diffracted by a crystal was magnified by beryllium parabolic refractive lenses on a 2D X-ray camera. The microscopy setup was integrated into the 6-circle Huber diffractometer at the ESRF beamline ID06. Our setup allowed us to visualize structural imperfections with a resolution of approximately 1 micrometer. The configuration, however, can easily be adapted for sub-micrometer resolution.
△ Less
Submitted 24 November, 2014; v1 submitted 22 September, 2014;
originally announced September 2014.
-
A 31T split-pair pulsed magnet for single crystal x-ray diffraction at low temperature
Authors:
F. Duc,
X. Fabrèges,
T. Roth,
C. Detlefs,
P. Frings,
M. Nardone,
J. Billette,
M. Lesourd,
L. Zhang,
A. Zitouni,
P. Delescluse,
J. Béard,
J. P. Nicolin,
G. L. J. A. Rikken
Abstract:
We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K. The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. Using a 1.15MJ mobile generator, magnetic field pulses of 60 ms leng…
▽ More
We have developed a pulsed magnet system with panoramic access for synchrotron x-ray diffraction in magnetic fields up to 31T and at low temperature down to 1.5 K. The apparatus consists of a split-pair magnet, a liquid nitrogen bath to cool the pulsed coil, and a helium cryostat allowing sample temperatures from 1.5 up to 250 K. Using a 1.15MJ mobile generator, magnetic field pulses of 60 ms length were generated in the magnet, with a rise time of 16.5 ms and a repetition rate of 2 pulses/hour at 31 T. The setup was validated for single crystal diffraction on the ESRF beamline ID06.
△ Less
Submitted 4 March, 2014;
originally announced March 2014.
-
X-ray polarization: General formalism and polarization analysis
Authors:
C. Detlefs,
M. Sanchez del Rio,
C. Mazzoli
Abstract:
The polarization of x-rays plays an outstanding role in experimental techniques such as non-resonant magnetic x-ray scattering and resonant x-ray scattering of magnetic and multipolar order. Different instrumental methods applied to synchrotron light can transform its natural polarization into an arbitrary polarization state. Several synchrotron applications, in particular in the field of magnetic…
▽ More
The polarization of x-rays plays an outstanding role in experimental techniques such as non-resonant magnetic x-ray scattering and resonant x-ray scattering of magnetic and multipolar order. Different instrumental methods applied to synchrotron light can transform its natural polarization into an arbitrary polarization state. Several synchrotron applications, in particular in the field of magnetic and resonant scattering rely on the improvement in the signal/noise ratio or the deeper insight into the ordered state and the scattering process made possible through these polarization techniques. Here, we present the mathematical framework for the description of fully and partially polarized x-rays, with some applications such as linear x-ray polarization analysis for the determination of the scattered beam's polarization, and the Ge K-edge resonant scattering.
△ Less
Submitted 22 June, 2011;
originally announced June 2011.
-
A Photon Regeneration Experiment for Axionlike Particle Search using X-rays
Authors:
Remy Battesti,
Mathilde Fouché,
C. Detlefs,
T. Roth,
Paul Berceau,
F. Duc,
P. Frings,
G. L. J. A. Rikken,
Carlo Rizzo
Abstract:
In this letter we describe our novel photon regeneration experiment for the axionlike particle search using a x-ray beam with a photon energy of 50.2 keV and 90.7 keV, two superconducting magnets of 3 T, and a Ge detector with a high quantum efficiency. A counting rate of regenerated photons compatible with zero has been measured. The corresponding limits on the pseudoscalar axionlike particle-two…
▽ More
In this letter we describe our novel photon regeneration experiment for the axionlike particle search using a x-ray beam with a photon energy of 50.2 keV and 90.7 keV, two superconducting magnets of 3 T, and a Ge detector with a high quantum efficiency. A counting rate of regenerated photons compatible with zero has been measured. The corresponding limits on the pseudoscalar axionlike particle-two photon coupling constant is obtained as a function of the particle mass. Our setup widens the energy window of purely terrestrial experiments devoted to the axionlike particle search by coupling to two photons. It also opens a new domain of experimental investigation of photon propagation in magnetic fields.
△ Less
Submitted 3 December, 2010; v1 submitted 16 August, 2010;
originally announced August 2010.