(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–10 of 10 results for author: Ferrini, M

Searching in archive physics. Search in all archives.
.
  1. arXiv:2209.02020  [pdf, other

    physics.ins-det hep-ex

    Searching for an eco-friendly gas mixture for the ALICE Resistive Plate Chambers

    Authors: Luca Quaglia, R. Cardarelli, B. Liberti, E. Pastori, G. Proto, G. Aielli, P. Camarri, A. Di Ciacco, L. Di Stante, R. Santonico, G. Alberghi, D. Boscherini, A. Bruni, L. Massa, A. Polini, M. Romano, L. Benussi, S. Bianco, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo M. Ferrini, G. Saviano, M. Abbrescia, L. Congedo , et al. (25 additional authors not shown)

    Abstract: The ALICE RPCs are operated with a mixture of 89.7% $C_{2}H_{2}F_{4}$, 10% i-$C_{4}H_{10}$ and 0.3% $SF_{6}$. $C_{2}H_{2}F_{4}$ and $SF_{6}$ are fluorinated greenhouse gases with a high Global Warming Potential (GWP). New European Union regulations have imposed a progressive phase-down of the production and usage of F-gases, aiming to cut down their emission by two thirds in 2030 with respect to 2… ▽ More

    Submitted 5 September, 2022; originally announced September 2022.

    Comments: Proceedings of the LHCp 2022 conference

  2. arXiv:1605.08172  [pdf

    physics.ins-det hep-ex

    Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    Authors: M. Abbrescia, P. Van Auwegem, L. Benussi, S. Bianco, S. Cauwenbergh, M. Ferrini, S. Muhammad, L. Passamonti, D. Pierluigi, D. Piccolo, F. Primavera, A. Russo, G. Saviano, M. Tytgat

    Abstract: The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of ef… ▽ More

    Submitted 26 May, 2016; originally announced May 2016.

    Comments: 7 pages, 7 figures. arXiv admin note: text overlap with arXiv:1505.01648

  3. arXiv:1605.01691  [pdf, ps, other

    physics.ins-det hep-ex

    Eco-friendly gas mixtures for Resistive Plate Chambers based on Tetrafluoropropene and Helium

    Authors: M. Abbrescia, L. Benussi, S. Bianco, M. Ferrini, S. Muhammad, L. Passamonti, D. Pierluigi, D. Piccolo, F. Primavera, A. Russo, G. Saviano

    Abstract: Due to the recent restrictions deriving from the application of the Kyoto protocol, the main components of the gas mixtures presently used in the Resistive Plate Chambers systems of the LHC experiments will be most probably phased out of production in the coming years. Identifying possible replacements with the adequate characteristics requires an intense R&D, which was recently started, also in c… ▽ More

    Submitted 4 May, 2016; originally announced May 2016.

    Comments: 9 pages, 6 figures, 1 table

  4. arXiv:1512.08621  [pdf, ps, other

    physics.ins-det

    Characterization of the GEM foil materials

    Authors: L. Benussi, S. Bianco, G. Saviano, S. Muhammad, D. Piccolo, G. Raffone, M. Caponero, L. Passamonti, D. Pierluigi, A. Russo, F. Primavera, S. Cerbelli, A. Lalli, M. Valente, M. Ferrini, B. Teissandier, M. Taborelli, M. Parvis, S. Grassini, J. Tirilló, F. Sarasini, A. V. Franchi

    Abstract: Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the detector's foil can possibly change its mechanical and electrical properties and, in such a way, the detector performance can be affected. To understand this phenomenon, a model is developed with COMSOL M… ▽ More

    Submitted 29 December, 2015; originally announced December 2015.

    Comments: Four pages, eight figures, presented by S. Muhammad at the MPGD2015, Trieste, Italy

    Report number: INFN-15-12/LNF

  5. arXiv:1512.08542  [pdf, ps, other

    physics.ins-det

    Candidate eco-friendly gas mixtures for MPGDs

    Authors: L. Benussi, S. Bianco, G. Saviano, S. Muhammad, D. Piccolo, F. Primavera, M. Ferrini, M. Parvis, S. Grassing, S. Colafranceschi, J. Kjøbro, A. Sharma, D. Yang, G. Chen, Y. Ban, Q. Li

    Abstract: Modern gas detectors for detection of particles require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This review studies properties of potential eco-friendly gas candidate replacements.

    Submitted 28 December, 2015; originally announced December 2015.

    Comments: Four pages, four figures, presented by Giovanna Saviano at MPGD2015, Trieste, Italy

    Report number: INFN-15-11

  6. arXiv:1505.01648  [pdf, ps, other

    physics.ins-det hep-ex

    A study of HFO-1234ze (1,3,3,3-Tetrafluoropropene) as an eco-friendly replacement in RPC detectors

    Authors: L. Benussi, S. Bianco, M. Ferrini, L. Passamonti, D. Pierluigi, D. Piccolo, A. Russo, G. Saviano

    Abstract: The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This report shows results of studies on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze.

    Submitted 7 May, 2015; originally announced May 2015.

    Comments: 15 pages, 20 figures

    Report number: INFN report INFN-14-14/LNF

  7. arXiv:1412.0228  [pdf, other

    physics.ins-det

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, W. Ahmed, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo , et al. (113 additional authors not shown)

    Abstract: Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midηいーた\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi… ▽ More

    Submitted 8 December, 2014; v1 submitted 30 November, 2014; originally announced December 2014.

    Comments: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference added

  8. arXiv:1302.5225   

    physics.ins-det hep-ex

    Study of gas contaminants and interaction with materials in RPC closed loop system

    Authors: S. Colafranceschi, R. Aurilio, L. Benussi, S. Bianco, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, M. Ferrini, T. Greci, G. Saviano, C. Vendittozzi, M. Abbrescia, C. Calabria, A. Colaleo, G. Iaselli, M. Maggi, S. Nuzzo, G. Pugliese, P. Verwilligen, A. Sharma

    Abstract: Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminan… ▽ More

    Submitted 22 March, 2013; v1 submitted 21 February, 2013; originally announced February 2013.

    Comments: This paper has been withdrawn by the authors. revised version of already uploaded paper [1210.1819]

  9. arXiv:1210.1819  [pdf, ps, other

    physics.ins-det hep-ex

    A study of gas contaminants and interaction with materials in RPC closed loop systems

    Authors: S. Colafranceschi, R. Aurilio, L. Benussi, S. Bianco, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, M. Ferrini, T. Greci, G. Saviano, C. Vendittozzi, M. Abbrescia, C. Calabria, A. Colaleo, G. Iaselli, M. Maggi, S. Nuzzo, G. Pugliese, P. Verwilligen, A. Sharma

    Abstract: Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contami… ▽ More

    Submitted 5 October, 2012; originally announced October 2012.

  10. arXiv:1012.5511  [pdf, ps, other

    physics.ins-det hep-ex

    Study of gas purifiers for the CMS RPC detector

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, F. Felli, M. Ferrini, M. Giardoni, T. Greci, A. Paolozzi, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, G. Saviano, S. Buontempo, A. Cimmino, M. de Gruttola, F Fabozzi d A. O. M. Iorio, L. Lista, P. Paolucci, P. Baesso, G. Belli, D. Pagano, S. P. Ratti, A. Vicini , et al. (4 additional authors not shown)

    Abstract: The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clar… ▽ More

    Submitted 26 December, 2010; originally announced December 2010.