-
Cosmic ray susceptibility of the Terahertz Intensity Mapper detector arrays
Authors:
Lun-Jun Liu,
Reinier M. J. Janssen,
Bruce Bumble,
Elijah Kane,
Logan M. Foote,
Charles M. Bradford,
Steven Hailey-Dunsheath,
Shubh Agrawal,
James E. Aguirre,
Hrushi Athreya,
Justin S. Bracks,
Brockton S. Brendal,
Anthony J. Corso,
Jeffrey P. Filippini,
Jianyang Fu,
Christopher E. Groppi,
Dylan Joralmon,
Ryan P. Keenan,
Mikolaj Kowalik,
Ian N. Lowe,
Alex Manduca,
Daniel P. Marrone,
Philip D. Mauskopf,
Evan C. Mayer,
Rong Nie
, et al. (4 additional authors not shown)
Abstract:
We report on the effects of cosmic ray interactions with the Kinetic Inductance Detector (KID) based focal plane array for the Terahertz Intensity Mapper (TIM). TIM is a NASA-funded balloon-borne experiment designed to probe the peak of the star formation in the Universe. It employs two spectroscopic bands, each equipped with a focal plane of four $\sim\,$900-pixel, KID-based array chips. Measurem…
▽ More
We report on the effects of cosmic ray interactions with the Kinetic Inductance Detector (KID) based focal plane array for the Terahertz Intensity Mapper (TIM). TIM is a NASA-funded balloon-borne experiment designed to probe the peak of the star formation in the Universe. It employs two spectroscopic bands, each equipped with a focal plane of four $\sim\,$900-pixel, KID-based array chips. Measurements of an 864-pixel TIM array shows 791 resonators in a 0.5$\,$GHz bandwidth. We discuss challenges with resonator calibration caused by this high multiplexing density. We robustly identify the physical positions of 788 (99.6$\,$%) detectors using a custom LED-based identification scheme. Using this information we show that cosmic ray events occur at a rate of 2.1$\,\mathrm{events/min/cm^2}$ in our array. 66$\,$% of the events affect a single pixel, and another 33$\,$% affect $<\,$5 KIDs per event spread over a 0.66$\,\mathrm{cm^2}$ region (2 pixel pitches in radius). We observe a total cosmic ray dead fraction of 0.0011$\,$%, and predict that the maximum possible in-flight dead fraction is $\sim\,$0.165$\,$%, which demonstrates our design will be robust against these high-energy events.
△ Less
Submitted 24 July, 2024;
originally announced July 2024.
-
A 25-micron single photon sensitive kinetic inductance detector
Authors:
Peter K. Day,
Nicholas F. Cothard,
Christopher Albert,
Logan Foote,
Elijah Kane,
Byeong H. Eom,
Ritoban Basu Thakur,
Reinier M. J. Janssen,
Andrew Beyer,
Pierre Echternach,
Sven van Berkel,
Steven Hailey-Dunsheath,
Thomas R. Stevenson,
Shahab Dabironezare,
Jochem J. A. Baselmans,
Jason Glenn,
C. Matt Bradford,
Henry G. Leduc
Abstract:
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integ…
▽ More
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
△ Less
Submitted 14 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
High-sensitivity Kinetic Inductance Detector Arrays for the Probe Far-Infrared Mission for Astrophysics
Authors:
Logan Foote,
Chris Albert,
Jochem Baselmans,
Andrew Beyer,
Nicholas Cothard,
Peter Day,
Steven Hailey-Dunsheath,
Pierre Echternach,
Reinier Janssen,
Elijah Kane,
Henry Leduc,
Lun-Jun Liu,
Hien Nguyen,
Joanna Perido,
Jason Glenn,
Jonas Zmuidzinas,
Charles,
Bradford
Abstract:
Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utili…
▽ More
Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utilization of PRIMA's cold telescope requires far-IR detector arrays with per-pixel noise equivalent powers (NEPs) at or below 1 x 10-19 W/rtHz. We are developing low-volume Aluminum kinetic inductance detector (KID) arrays to reach these sensitivities. We will present on the development of our long-wavelength (210 um) array approach, with a focus on multitone measurements of our 1,008-pixel arrays. We measure an NEP below 1 x 10-19 W/rtHz for 73 percent of our pixels.
△ Less
Submitted 29 May, 2024; v1 submitted 3 November, 2023;
originally announced November 2023.
-
High-sensitivity transition-edge-sensed bolometers: improved speed and characterization with AC and DC bias
Authors:
Logan Foote,
Michael D. Audley,
Charles,
Bradford,
Gert de Lange,
Pierre Echternach,
Dale J. Fixsen,
Howard Hui,
Matthew Kenyon,
Hien Nguyen,
Roger O'Brient,
Elmer H. Sharp,
Johannes G. Staguhn,
Jan van der Kuur,
Jonas Zmuidzinas
Abstract:
We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a reduction in the detector time constant. However, we also measure an increase in the temperature-normalized thermal conductance (G), and a corresponding increase in the…
▽ More
We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a reduction in the detector time constant. However, we also measure an increase in the temperature-normalized thermal conductance (G), and a corresponding increase in the noise-equivalent power (NEP). We employ a new near-IR photon-noise technique using a near-IR laser to calibrate the frequency-domain multiplexed AC system and compare the results to a well-understood DC circuit. We measure an NEP white noise level of 0.8 aW/rtHz with a 1/f knee below 0.1 Hz and a time constant of 3.2 ms.
△ Less
Submitted 13 September, 2023;
originally announced September 2023.
-
Modelling small block aperture in an in-house developed GPU-accelerated Monte Carlo-based dose engine for pencil beam scanning proton therapy
Authors:
Hongying Feng,
Jason M. Holmes,
Sujay A. Vora,
Joshua B. Stoker,
Martin Bues,
William W. Wong,
Terence S. Sio,
Robert L. Foote,
Samir H. Patel,
Jiajian Shen,
Wei Liu
Abstract:
Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and Materials: A block aperture module was integrated into VPMC. VPMC was validated by an ope…
▽ More
Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and Materials: A block aperture module was integrated into VPMC. VPMC was validated by an opensource code, MCsquare, in eight water phantom simulations with 3cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45mm water equivalent thickness. VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 cc). Finally, 3 patients were selected for robust optimization with aperture blocks using VPMC. Results: In the water phantoms, 3D gamma passing rate (2%/2mm/10%) between VPMC and MCsquare were 99.71$\pm$0.23%. In the patient geometries, 3D gamma passing rates (3%/2mm/10%) between VPMC/MCsquare and RayStation MC were 97.79$\pm$2.21%/97.78$\pm$1.97%, respectively. The calculation time was greatly decreased from 112.45$\pm$114.08 seconds (MCsquare) to 8.20$\pm$6.42 seconds (VPMC), both having statistical uncertainties of about 0.5%. The robustly optimized plans met all the dose-volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 seconds. Conclusion: VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.
△ Less
Submitted 3 July, 2023;
originally announced July 2023.