(Translated by https://www.hiragana.jp/)
Search | arXiv e-print repository
Skip to main content

Showing 1–49 of 49 results for author: Giboni, K

Searching in archive physics. Search in all archives.
.
  1. arXiv:2403.06220  [pdf, other

    hep-ex physics.ins-det

    Detecting Neutrinos from Supernova Bursts in PandaX-4T

    Authors: Binyu Pang, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Chen Cheng, Zhaokan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Chencheng Han, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Junting Huang, Zhou Huang, Ruquan Hou , et al. (71 additional authors not shown)

    Abstract: Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict… ▽ More

    Submitted 10 March, 2024; originally announced March 2024.

    Comments: 9 pages,6 figures

  2. arXiv:2403.04239  [pdf, other

    physics.ins-det hep-ex

    Signal Response Model in PandaX-4T

    Authors: Yunyang Luo, Zihao Bo, Shibo Zhang, Abdusalam Abdukerim, Chen Cheng, Wei Chen, Xun Chen, Yunhua Chen, Zhaokan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Chencheng Han, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Zhou Huang , et al. (66 additional authors not shown)

    Abstract: PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as ga… ▽ More

    Submitted 14 June, 2024; v1 submitted 7 March, 2024; originally announced March 2024.

  3. arXiv:2312.11072  [pdf, other

    hep-ex physics.ins-det

    Waveform Simulation in PandaX-4T

    Authors: Jiafu Li, Abdusalam Abdukerim, Chen Cheng, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Zhaokan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Chencheng Han, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Zhou Huang, Ruquan Hou , et al. (66 additional authors not shown)

    Abstract: Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considera… ▽ More

    Submitted 21 May, 2024; v1 submitted 18 December, 2023; originally announced December 2023.

    Journal ref: Chin. Phys. C 48, no.7,073001 (2024)

  4. arXiv:2206.06087  [pdf, other

    hep-ex physics.ins-det

    Neutron-induced nuclear recoil background in the PandaX-4T experiment

    Authors: Zhou Huang, Guofang Shen, Qiuhong Wang, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Yunshan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Chencheng Han, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang , et al. (55 additional authors not shown)

    Abstract: Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also u… ▽ More

    Submitted 29 July, 2022; v1 submitted 13 June, 2022; originally announced June 2022.

    Comments: 14 pages, 14 figures, 6 tables

  5. arXiv:2204.11175  [pdf, other

    hep-ex physics.data-an physics.ins-det

    Study of background from accidental coincidence signals in the PandaX-II experiment

    Authors: PandaX-II Collaboration, :, Abdusalam Abdukerim, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Di Huang, Yan Huang, Yanlin Huang, Zhou Huang, Xiangdong Ji, Yonglin Ju, Shuaijie Li , et al. (42 additional authors not shown)

    Abstract: The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of th… ▽ More

    Submitted 1 July, 2022; v1 submitted 23 April, 2022; originally announced April 2022.

    Comments: 20 pages, 12 figures in main text and 5 figures in the appendix. Accepted by Chinese Physics C

  6. arXiv:2112.08957  [pdf, other

    hep-ex physics.ins-det

    A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

    Authors: Xiangyi Cui, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Yunshan Cheng, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Zhou Huang, Ruquan Hou, Xiangdong Ji, Yonglin Ju , et al. (54 additional authors not shown)

    Abstract: We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enha… ▽ More

    Submitted 11 April, 2022; v1 submitted 16 December, 2021; originally announced December 2021.

    Comments: 8 pages, 5 figures, 1 table. New constraints adopted a CRDM energy cutoff at 0.2 GeV, and some uncertainties from the cosmic ray propagation model and dark matter density are studied

  7. arXiv:2112.02892  [pdf, other

    physics.ins-det hep-ex

    Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

    Authors: Zhicheng Qian, Lin Si, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Yunshan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Zhou Huang, Ruquan Hou , et al. (54 additional authors not shown)

    Abstract: PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low backgro… ▽ More

    Submitted 23 April, 2022; v1 submitted 6 December, 2021; originally announced December 2021.

    Comments: 19 pages, 7 figures, 12 tables

  8. arXiv:2111.01492  [pdf, other

    physics.ins-det hep-ex

    Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

    Authors: Zhou Huang, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Yunshan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Ruquan Hou, Xiangdong Ji, Yonglin Ju , et al. (54 additional authors not shown)

    Abstract: The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's… ▽ More

    Submitted 3 December, 2021; v1 submitted 2 November, 2021; originally announced November 2021.

    Journal ref: 2022 JINST 17 P01008

  9. arXiv:2107.13438  [pdf, other

    hep-ex physics.ins-det

    Dark Matter Search Results from the PandaX-4T Commissioning Run

    Authors: Yue Meng, Zhou Wang, Yi Tao, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Yunshan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Zhou Huang , et al. (54 additional authors not shown)

    Abstract: We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to… ▽ More

    Submitted 17 December, 2021; v1 submitted 28 July, 2021; originally announced July 2021.

    Comments: proof draft as PRL

  10. On the Electrode Configurations in a Large Single Phase Liquid Xenon Detector for Dark Matter Searches

    Authors: P. Juyal, K. L. Giboni, X. Ji, J. Liu

    Abstract: In the near future there will be the request for very large liquid Xenon (LXe) detectors for Dark Matter (DM) searches in the 50-ton range. To avoid an impractically long, single drift space of a dual-phase detector, it seems beneficial to use the single-phase technique. Since electrons then can drift in any direction, we can segment the homogeneous medium and thus avoid an excessive maximum drift… ▽ More

    Submitted 16 July, 2021; originally announced July 2021.

  11. Screener3D: a Gaseous Time Projection Chamber for Ultra-low Radioactive Material Screening

    Authors: Haiyan Du, Chengbo Du, Karl Giboni, Ke Han, Shengming He, Liqiang Liu, Yue Meng, Shaobo Wang, Tao Zhang, Li Zhao, Jifang Zhou

    Abstract: In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We propose to develop a gaseous time projection chamber (TPC) with a Micromegas readout for radio screening. The TPC records three-dimensional trajectories of charged p… ▽ More

    Submitted 23 December, 2021; v1 submitted 13 July, 2021; originally announced July 2021.

    Journal ref: Nuclear Science and Techniques(2021)

  12. arXiv:2106.08380  [pdf, other

    physics.ins-det hep-ex

    Horizontal Position Reconstruction in PandaX-II

    Authors: Dan Zhang, Andi Tan, Abdusalam Abdukerim, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Shengming He, Di Huang, Yan Huang, Yanlin Huang, Zhou Huang, Xiangdong Ji, Yonglin Ju , et al. (47 additional authors not shown)

    Abstract: Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid… ▽ More

    Submitted 7 October, 2021; v1 submitted 15 June, 2021; originally announced June 2021.

    Comments: 18 pages, 11 figures

  13. arXiv:2102.09158  [pdf, other

    physics.ins-det hep-ex

    Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector

    Authors: Binbin Yan, Abdusalam Abdukerim, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Di Huang, Peiyao Huang, Yan Huang, Yanlin Huang, Zhou Huang, Xiangdong Ji, Yonglin Ju, Shuaijie Li , et al. (41 additional authors not shown)

    Abstract: We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with injected tritiated methane or $^{220}$Rn source, and with $^{241}$Am-Be neutron source, within an energy range from $1-25$ keV (ER) and $4-80$ keV (NR), under the… ▽ More

    Submitted 18 February, 2021; originally announced February 2021.

    Comments: 12 pages, 7 figures

  14. The Cryogenics and Xenon handling system for the PandaX-4T Experiment

    Authors: Li Zhao, Xiangyi Cui, Wenbo Ma, Yingjie Fan, Karl Giboni, Tao Zhang, Jianglai Liu, Xiangdong Ji

    Abstract: PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large detector. In this paper, the results on the commission of the cryogenics and gas handling system are reported. The maximum cooling power of ~ 580 W at 178 K with… ▽ More

    Submitted 18 December, 2020; originally announced December 2020.

    Comments: 15 pages, 11 figures

  15. arXiv:2006.09311  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

    Authors: Wenbo Ma, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Shengming He, Di Huang, Yan Huang, Yanlin Huang, Zhou Huang, Xiangdong Ji, Yonglin Ju , et al. (43 additional authors not shown)

    Abstract: We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $αあるふぁ$, $βべーた$, and $γがんま$ particles wit… ▽ More

    Submitted 4 January, 2021; v1 submitted 16 June, 2020; originally announced June 2020.

    Comments: 14 pages, 8 figures. published in JINST

    Journal ref: JINST 15 P12038 (2020)

  16. arXiv:1910.13160  [pdf, other

    physics.ins-det

    On Proportional Scintillation in Very Large LXe Detectors

    Authors: P. Juyal, K. L. Giboni, X. Ji, J. Liu

    Abstract: The charge read out of a LXe detector via Proportional Scintillation in the liquid phase was first realized by the Waseda group 40 years ago, but at that time the technical challenges were overwhelming. Although the tests were successful, this method was finally discarded and eventually nearly forgotten. For present day large LXe Dark Matter detectors, this approach was not even considered. Instea… ▽ More

    Submitted 29 October, 2019; originally announced October 2019.

  17. arXiv:1909.09698  [pdf, other

    physics.ins-det

    A LN$_2$ Based Cooling System for a Next Generation Liquid Xenon Dark Matter Detector

    Authors: K. L. Giboni, P. Juyal, E. Aprile, Y. Zhang, J. Naganoma

    Abstract: In recent years cooling technology for Liquid Xenon (LXe) detectors has advanced driven by the development of Dark Matter (DM) detectors with target mass in the 100 - 1,000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg (50 t) range requiring more than 1 kW of cooling power. Most of the prior cooling methods become impractical at this level. For cooling a 50 t… ▽ More

    Submitted 20 September, 2019; originally announced September 2019.

    Comments: 18 pages, 7 figures

  18. arXiv:1907.00545  [pdf, other

    hep-ex nucl-ex physics.ins-det

    An Improved Evaluation of the Neutron Background in the PandaX-II Experiment

    Authors: Qiuhong Wang, Abdusalam Abdukerim, Wei Chen, Xun Chen, Yunhua Chen, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Lisheng Geng, Karl Giboni, Franco Giuliani, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Di Huang, Yan Huang, Yanlin Huang, Zhou Huang, Peng Ji, Xiangdong Ji, Yonglin Ju, Yihui Lai, Kun Liang , et al. (38 additional authors not shown)

    Abstract: In dark matter direct detection experiments, neutron is a serious source of background, which can mimic the dark matter-nucleus scattering signals. In this paper, we present an improved evaluation of the neutron background in the PandaX-II dark matter experiment by a novel approach. Instead of fully relying on the Monte Carlo simulation, the overall neutron background is determined from the neutro… ▽ More

    Submitted 24 July, 2019; v1 submitted 1 July, 2019; originally announced July 2019.

    Comments: 9 pages, 9 figures, 7 tables; version2 accepted by Sci. China Phys. Mech. Astron

  19. arXiv:1906.11457  [pdf, other

    hep-ex nucl-ex physics.ins-det

    Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector

    Authors: Kaixiang Ni, Yihui Lai, Abdusalam Abdukerim, Wei Chen, Xun Chen, Yunhua Chen, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Lisheng Geng, Karl Giboni, Franco Giuliani, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Di Huang, Yan Huang, Yanlin Huang, Zhou Huang, Peng Ji, Xiangdong Ji, Yonglin Ju, Kun Liang , et al. (38 additional authors not shown)

    Abstract: We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg… ▽ More

    Submitted 27 June, 2019; originally announced June 2019.

    Comments: Submitted to Chinese Physics C

  20. arXiv:1903.03979  [pdf, ps, other

    physics.ins-det hep-ex

    Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

    Authors: J Galan, X Chen, H Du, C Fu, K Giboni, F Giuliani, K Han, B Jiang, X Ji, H Lin, Y Lin, J Liu, K Ni, X Ren, S Wang, S Wu, C Xie, Y Yang, D Zhang, T Zhang, L Zhao, S Aune, Y Bedfer, E Berthoumieux, D Calvet , et al. (42 additional authors not shown)

    Abstract: The PandaX-III experiment plans to search for neutrinoless double beta decay (0$νにゅーβべーたβべーた$) of $^{136}$Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous Time Projection Chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to the software side of the experiment. As software tool we use REST, a f… ▽ More

    Submitted 22 July, 2019; v1 submitted 10 March, 2019; originally announced March 2019.

    Comments: 40 pages, 15 figures. Prepared for submission to Journal of Physics G

  21. Dark matter direct search sensitivity of the PandaX-4T experiment

    Authors: Hongguang Zhang, Abdusalam Abdukerim, Xun Chen, Yunhua Chen, Xiangyi Cui, Binbin Dong, Deqing Fang, Changbo Fu, Karl Giboni, Franco Giuliani, Linhui Gu, Xuyuan Guo, Zhifan Guo, Ke Han, Changda He, Shengming He, Di Huang, Xingtao Huang, Zhou Huang, Peng Ji, Xiangdong Ji, Yonglin Ju, Shaoli Li, Yao Li, Heng Lin , et al. (35 additional authors not shown)

    Abstract: The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulation study of the expected background in this experiment. In a 2.8-ton fiducial mass and the signal region between 1 to 10 keV electron equivalent energy, the total electron recoil background is found to be 4.9x10^{-5} /(… ▽ More

    Submitted 7 June, 2018; v1 submitted 6 June, 2018; originally announced June 2018.

    Comments: 11 pages, 13 figures

  22. arXiv:1708.07051  [pdf, other

    astro-ph.IM astro-ph.CO hep-ex physics.ins-det

    The XENON1T Dark Matter Experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, B. Antunes, F. Arneodo, M. Balata, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso , et al. (120 additional authors not shown)

    Abstract: The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomu… ▽ More

    Submitted 23 August, 2017; originally announced August 2017.

    Comments: 22 pages, 25 figures

  23. arXiv:1708.06917  [pdf, other

    astro-ph.CO hep-ex hep-ph physics.ins-det

    Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment

    Authors: PandaX-II Collaboration, :, Xiangyi Cui, Abdusalam Abdukerim, Wei Chen, Xun Chen, Yunhua Chen, Binbin Dong, Deqing Fang, Changbo Fu, Karl Giboni, Franco Giuliani, Linhui Gu, Yikun Gu, Xuyuan Guo, Zhifan Guo, Ke Han, Changda He, Di Huang, Shengming He, Xingtao Huang, Zhou Huang, Xiangdong Ji, Yonglin Ju, Shaoli Li , et al. (33 additional authors not shown)

    Abstract: We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were… ▽ More

    Submitted 21 September, 2017; v1 submitted 23 August, 2017; originally announced August 2017.

    Comments: Supplementary materials at https://pandax.sjtu.edu.cn/articles/2nd/supplemental.pdf version 2 as accepted by PRL

    Journal ref: Phys. Rev. Lett. 119, 181302 (2017)

  24. arXiv:1610.08883  [pdf, other

    physics.ins-det hep-ex nucl-ex

    PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

    Authors: Xun Chen, Changbo Fu, Javier Galan, Karl Giboni, Franco Giuliani, Linghui Gu, Ke Han, Xiangdong Ji, Heng Lin, Jianglai Liu, Kaixiang Ni, Hiroki Kusano, Xiangxiang Ren, Shaobo Wang, Yong Yang, Dan Zhang, Tao Zhang, Li Zhao, Xiangming Sun, Shouyang Hu, Siyu Jian, Xinglong Li, Xiaomei Li, Hao Liang, Huanqiao Zhang , et al. (45 additional authors not shown)

    Abstract: Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment… ▽ More

    Submitted 27 October, 2016; v1 submitted 27 October, 2016; originally announced October 2016.

  25. arXiv:1607.07400  [pdf, other

    hep-ex physics.ins-det

    Dark Matter Results from First 98.7-day Data of PandaX-II Experiment

    Authors: PandaX-II Collaboration, :, Andi Tan, Mengjiao Xiao, Xiangyi Cui, Xun Chen, Yunhua Chen, Deqing Fang, Changbo Fu, Karl Giboni, Franco Giuliani, Haowei Gong, Shouyang Hu, Xingtao Huang, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Xiaomei Li, Xinglong Li, Hao Liang, Qing Lin, Huaxuan Liu, Jianglai Liu, Wolfgang Lorenzon , et al. (29 additional authors not shown)

    Abstract: We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit… ▽ More

    Submitted 22 August, 2016; v1 submitted 25 July, 2016; originally announced July 2016.

    Comments: version accepted by PRL, 12 pages, 5+11 figures (including supplementary materials), 4 tables

    Journal ref: Phys. Rev. Lett. 117, 121303 (2016)

  26. arXiv:1602.06563  [pdf, other

    hep-ex physics.ins-det

    Dark Matter Search Results from the Commissioning Run of PandaX-II

    Authors: PandaX Collaboration, Andi Tan, Xiang Xiao, Xiangyi Cui, Xun Chen, Yunhua Chen, Deqing Fang, Changbo Fu, Karl Giboni, Franco Giuliani, Haowei Gong, Shouyang Hu, Xingtao Huang, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Xiaomei Li, Xinglong Li, Hao Liang, Qing Lin, Huaxuan Liu, Jianglai Liu, Wolfgang Lorenzon, Yugang Ma , et al. (29 additional authors not shown)

    Abstract: We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independ… ▽ More

    Submitted 5 June, 2016; v1 submitted 21 February, 2016; originally announced February 2016.

    Comments: 7 pages, 6 figures, v2 as accepted by PRD

    Journal ref: Phys. Rev. D 93, 122009 (2016)

  27. arXiv:1511.06223  [pdf, other

    physics.ins-det hep-ex

    Performance of Photosensors in the PandaX-I Experiment

    Authors: Shaoli Li, Xun Chen, Karl L. Giboni, Guodong Guo, Xiangdong Ji, Qing Lin, Jianglai Liu, Yajun Mao, Kaixuan Ni, Xiangxiang Ren, Andi Tan, Mengjiao Xiao, Xiaopeng Zhou

    Abstract: We report the long term performance of the photosensors, 143 one-inch R8520-406 and 37 three-inch R11410-MOD photomultipliers from Hamamatsu, in the first phase of the PandaX dual-phase xenon dark matter experiment. This is the first time that a significant number of R11410 photomultiplier tubes were operated in liquid xenon for an extended period, providing important guidance to the future large… ▽ More

    Submitted 29 January, 2016; v1 submitted 18 November, 2015; originally announced November 2015.

    Comments: v3 as accepted by JINST with modifications based on reviewers' comments

  28. arXiv:1505.00771  [pdf, other

    hep-ex astro-ph.IM physics.ins-det

    Low-mass dark matter search results from full exposure of PandaX-I experiment

    Authors: PandaX Collaboration, Xiang Xiao, Xun Chen, Andi Tan, Yunhua Chen, Xiangyi Cui, Deqing Fang, Changbo Fu, Karl L. Giboni, Haowei Gong, Guodong Guo, Ming He, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Qing Lin, Huaxuan Liu, Jianglai Liu, Xiang Liu, Wolfgang Lorenzon, Yugang Ma, Yajun Mao, Kaixuan Ni, Kirill Pushkin , et al. (21 additional authors not shown)

    Abstract: We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass o… ▽ More

    Submitted 20 August, 2015; v1 submitted 4 May, 2015; originally announced May 2015.

    Comments: v3 as accepted by PRD. Minor update in the text in response to referee comments. Separating Fig. 11(a) and (b) into Fig. 11 and Fig. 12. Legend tweak in Fig. 9(b) and 9(c) as suggested by referee, as well as a missing legend for CRESST-II legend in Fig. 12 (now Fig. 13). Same version as submitted to PRD

    Journal ref: Phys. Rev. D 92, 052004 (2015)

  29. arXiv:1408.5114  [pdf, other

    hep-ex astro-ph.IM physics.ins-det

    First dark matter search results from the PandaX-I experiment

    Authors: PandaX Collaboration, Mengjiao Xiao, Xiang Xiao, Li Zhao, Xiguang Cao, Xun Chen, Yunhua Chen, Xiangyi Cui, Deqing Fang, Changbo Fu, Karl L. Giboni, Haowei Gong, Guodong Guo, Jie Hu, Xingtao Huang, Xiangdong Ji, Yonglin Ju, Siao Lei, Shaoli Li, Qing Lin, Huaxuan Liu, Jianglai Liu, Xiang Liu, Wolfgang Lorenzon, Yugang Ma , et al. (22 additional authors not shown)

    Abstract: We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positi… ▽ More

    Submitted 4 September, 2014; v1 submitted 21 August, 2014; originally announced August 2014.

    Comments: 7 pages, 6 figures, final version as appeared in the journal publication

    Journal ref: Xiao M J, Xiao X, Zhao L, et al. First dark matter search results from the PandaX-I experiment. Sci China-Phys Mech Astron, 2014, 57(11): 2024-2030

  30. arXiv:1405.2882  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    PandaX: A Liquid Xenon Dark Matter Experiment at CJPL

    Authors: X. G. Cao, X. Chen, Y. H. Chen, X. Y. Cui, D. Q. Fang, C. B. Fu, K. L. Giboni, H. W. Gong, G. D. Guo, M. He, J. Hu, X. T. Huang, X. D. Ji, Y. L. Ju, S. L. Li, Q. Lin, H. X. Liu, J. L. Liu, X. Liu, W. Lorenzon, Y. G. Ma, Y. J. Mao, K. X. Ni, K. Pushkin, X. X. Ren , et al. (25 additional authors not shown)

    Abstract: PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time proj… ▽ More

    Submitted 12 May, 2014; originally announced May 2014.

    Comments: 28 pages, 23 figures

  31. arXiv:1311.1088  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Observation and applications of single-electron charge signals in the XENON100 experiment

    Authors: E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella , et al. (55 additional authors not shown)

    Abstract: The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector… ▽ More

    Submitted 28 January, 2014; v1 submitted 5 November, 2013; originally announced November 2013.

    Comments: 16 pages, 8 figures. Accepted for publication in Journal of Physics G: Nuclear and Particle Physics

    Journal ref: E Aprile et al. [XENON100 Collaboration], J. Phys. G: Nucl. Part. Phys. 41 (2014) 035201

  32. arXiv:1306.2303  [pdf, other

    astro-ph.IM physics.ins-det

    The neutron background of the XENON100 dark matter experiment

    Authors: E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, A. Brown, E. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella, W. Fulgione , et al. (52 additional authors not shown)

    Abstract: The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($αあるふぁ$,n) and spontaneous fission re… ▽ More

    Submitted 2 September, 2013; v1 submitted 10 June, 2013; originally announced June 2013.

  33. arXiv:1211.0836  [pdf, other

    astro-ph.IM physics.ins-det

    The distributed Slow Control System of the XENON100 Experiment

    Authors: E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, A. Behrens, P. Beltrame, K. Bokeloh, E. Brown, G. M. Bruno, R. Budnik, M. Le Calloch, J. M. Cardoso, W. -T. Chen, B. Choi, H. Contreras, J. -P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella, W. Fulgione, F. Gao, M. Garbini , et al. (50 additional authors not shown)

    Abstract: The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature… ▽ More

    Submitted 5 November, 2012; originally announced November 2012.

    Comments: 12 pages, 4 figures

  34. arXiv:1209.3658  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon

    Authors: E. Aprile, R. Budnik, B. Choi, H. A. Contreras, K. -L. Giboni, L. W. Goetzke, J. E. Koglin, R. F. Lang, K. E. Lim, A. J. Melgarejo Fernandez, R. Persiani, G. Plante, A. Rizzo

    Abstract: We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs γがんま rays and the energy of the Compton-scattered γがんま rays was measured with a high-purity germanium (HPGe) detector placed at di… ▽ More

    Submitted 17 September, 2012; originally announced September 2012.

    Comments: 14 pages, 8 figures

  35. arXiv:1208.2001  [pdf, ps, other

    physics.ins-det hep-ex

    Performance of a cryogenic system prototype for the XENON1T Detector

    Authors: Elena Aprile, Ran Budnik, Bin Choi, Hugo Contreras, Karl Giboni, Luke Goetzke, Rafael Lang, Kyungeun Lim, Antonio melgarejo, Petr Shagin

    Abstract: We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas… ▽ More

    Submitted 29 August, 2012; v1 submitted 9 August, 2012; originally announced August 2012.

  36. arXiv:1207.5988  [pdf, other

    astro-ph.CO hep-ex hep-ph physics.ins-det

    Dark Matter Results from 225 Live Days of XENON100 Data

    Authors: XENON100 Collaboration, E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, E. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, D. Cline, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella , et al. (53 additional authors not shown)

    Abstract: We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence… ▽ More

    Submitted 20 March, 2013; v1 submitted 25 July, 2012; originally announced July 2012.

    Comments: 6 pages, 5 figures. Matches version accepted by PRL. Includes limits up to 10 TeV/c^2, published as supplementary material: http://prl.aps.org/supplemental/PRL/v109/i18/e181301 Please cite high mass limits as "Phys. Rev. Lett. 109, 181301 (2012), online supplementary material."

    Journal ref: Phys. Rev. Lett. 109, 181301 (2012)

  37. arXiv:1207.5432  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Measurement of the Quantum Efficiency of Hamamatsu R8520 Photomultipliers at Liquid Xenon Temperature

    Authors: E. Aprile, M. Beck, K. Bokeloh, R. Budnik, B. Choi, H. A. Contreras, K. -L. Giboni, L. W. Goetzke, R. F. Lang, K. E. Lim, A. J. Melgarejo Fernandez, G. Plante, A. Rizzo, P. Shagin, C. Weinheimer

    Abstract: Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to liquid xenon are being used to efficiently detect the 178 nm scintillation light in a variety of liquid xenon based particle detectors. Good knowledge of the performance of these photomultipliers under cryogenic conditions is needed to properly characterize these detectors. Here, we report on measurements of the quantum e… ▽ More

    Submitted 23 July, 2012; originally announced July 2012.

  38. arXiv:1207.5100  [pdf

    astro-ph.IM hep-ex physics.ins-det

    The Cryogenic System for the Panda-X Dark Matter Search Experiment

    Authors: Zhao Li, Karl Ludwig Giboni, Haowei Gong, Xiangdong Ji, Andy Tan

    Abstract: Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The first modestly-sized module will soon be installed in the China JinPing Deep Underground Laboratory in Sichuan province, P.R. China. The cryogenics system is designed to handle much larger detectors, even the final version in the ton scale. Special attention has been paid to the reliability, serviceability, and adaptabil… ▽ More

    Submitted 21 July, 2012; originally announced July 2012.

    Comments: 10 pages, 5 figures

  39. arXiv:1207.3458  [pdf, other

    astro-ph.IM physics.ins-det

    Analysis of the XENON100 Dark Matter Search Data

    Authors: The XENON100 Collaboration, E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, A. Behrens, P. Beltrame, K. Bokeloh, E. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, D. B. Cline, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella, W. Fulgione, F. Gao , et al. (49 additional authors not shown)

    Abstract: The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have… ▽ More

    Submitted 14 October, 2013; v1 submitted 14 July, 2012; originally announced July 2012.

    Comments: 18 pages, 17 figures, information for the 224.6 live days run included

    Journal ref: Astropart. Phys. 54 (2014) 11-24

  40. arXiv:1109.4270  [pdf, other

    astro-ph.IM physics.ins-det

    Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project

    Authors: V. Hannen, E. Aprile, F. Arneodo, L. Baudis, M. Beck, K. Bokeloh, A. D. Ferella, K. Giboni, R. F. Lang, O. Lebeda, H. -W. Ortjohann, M. Schumann, A. Spalek, D. Venos, C. Weinheimer

    Abstract: The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been inves… ▽ More

    Submitted 6 October, 2011; v1 submitted 20 September, 2011; originally announced September 2011.

    Comments: 11 pages, 7 figures, submitted to Journal of Instrumentation

    Journal ref: 2011 JINST 6 P10013

  41. Material screening and selection for XENON100

    Authors: XENON100 Collaboration, E. Aprile, K. Arisaka, F. Arneodo, A. Askin, L. Baudis, A. Behrens, K. Bokeloh, E. Brown, J. M. R. Cardoso, B. Choi, D. Cline, S. Fattori, A. D. Ferella, K. L. Giboni, A. Kish, C. W. Lam, J. Lamblin, R. F. Lang, K. E. Lim, J. A. M. Lopes, T. Marrodan Undagoitia, Y. Mei, A. J. Melgarejo Fernandez, K. Ni , et al. (16 additional authors not shown)

    Abstract: Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This Dark Matter search experiment is operated underground at Laboratori Nazionali del Gran Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors (HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been applied for a few low mass… ▽ More

    Submitted 22 June, 2011; v1 submitted 30 March, 2011; originally announced March 2011.

    Comments: 8 pages, 1 figure

    Journal ref: Astropart.Phys.35:43-49,2011

  42. arXiv:1103.0986  [pdf, other

    physics.ins-det hep-ex

    Xenon Recirculation-Purification with a Heat Exchanger

    Authors: K. L. Giboni, E. Aprile, B. Choi, T. Haruyama, R. F. Lang, K. E. Lim, A. J. Melgarejo, G. Plante

    Abstract: Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through a high-temperature getter. This challenges the traditional way of cooling these large detectors, since in a thermally well insulated detector, most of the cool… ▽ More

    Submitted 4 March, 2011; originally announced March 2011.

    Comments: 10 pages, 3 figures

    Journal ref: JINST 6 P03002 (2011)

  43. arXiv:0810.0274  [pdf, ps, other

    astro-ph physics.ins-det

    New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV

    Authors: E. Aprile, L. Baudis, B. Choi, K. L. Giboni, K. E. Lim, A. Manalaysay, M. E. Monzani, G. Plante, R. Santorelli, M. Yamashita

    Abstract: Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitiv… ▽ More

    Submitted 16 May, 2010; v1 submitted 1 October, 2008; originally announced October 2008.

    Comments: 8 pages, 8 figures

    Journal ref: Phys.Rev.C79:045807,2009

  44. arXiv:0807.0459  [pdf, other

    astro-ph physics.ins-det

    The scintillation and ionization yield of liquid xenon for nuclear recoils

    Authors: P. Sorensen, A. Manzur, C. E. Dahl, J. Angle, E. Aprile, F. Arneodo, L. Baudis, A. Bernstein, A. Bolozdynya, P. Brusov, L. C. C. Coelho, L. DeViveiros, A. D. Ferella, L. M. P. Fernandes, S. Fiorucci, R. J. Gaitskell, K. L. Giboni, R. Gomez, R. Hasty, L. Kastens, J. Kwong, J. A. M. Lopes, N. Madden, A. Manalaysay, D. N. McKinsey , et al. (12 additional authors not shown)

    Abstract: XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relati… ▽ More

    Submitted 30 December, 2008; v1 submitted 3 July, 2008; originally announced July 2008.

    Comments: 8 pages, 9 figures. To be published in Nucl. Instrum. Methods A

    Journal ref: Nucl.Instrum.Meth.A601:339-346,2009

  45. Compton Imaging of MeV Gamma-Rays with the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)

    Authors: E. Aprile, A. Curioni, K. L. Giboni, M. Kobayashi, U. G. Oberlack, S. Zhang

    Abstract: The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is the first realization of a liquid xenon time projection chamber for Compton imaging of MeV gamma-ray sources in astrophysics. By measuring the energy deposit and the three spatial coordinates of individual gamma-ray scattering points, the location of the source in the sky is inferred with Compton kinematics reconstruction. The angular res… ▽ More

    Submitted 2 May, 2008; originally announced May 2008.

    Comments: 22 pages, 20 figures, submitted to NIM A

    Journal ref: Nucl.Instrum.Meth.A593:414-425,2008

  46. arXiv:physics/0702142  [pdf

    physics.ins-det physics.atom-ph

    Secondary Scintillation Yield in Pure Xenon

    Authors: C. M. B. Monteiro, L. M. P. Fernandes, J. A. M. Lopes, L. C. C. Coelho, J. F. C. A. Veloso, J. M. F. dos Santos, K. Giboni, E. Aprile

    Abstract: The xenon secondary scintillation yield was studied as a function of the electric field in the scintillation region, in a gas proportional scintillation counter operated at room temperature. A large area avalanche photodiode was used for the readout of the VUV secondary scintillation produced in the gas, together with the 5.9 keV x-rays directly absorbed in the photodiode. The latter was used as… ▽ More

    Submitted 16 February, 2007; originally announced February 2007.

    Comments: 11 pages, 3 figures, submitted to JINST

    Journal ref: JINST 2 P05001 (2007)

  47. arXiv:physics/0702078  [pdf, ps, other

    physics.ins-det astro-ph

    A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign

    Authors: A. Curioni, E. Aprile, T. Doke, K. L. Giboni, M. Kobayashi, U. G. Oberlack

    Abstract: LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time projection chamber. One of the most relevant figures of merit for a Compton telescope is the detection efficiency for \g-rays, which depends on diverse contributions such as detector geometry and passive materials, trigger efficiency, dead time, etc.… ▽ More

    Submitted 9 February, 2007; v1 submitted 9 February, 2007; originally announced February 2007.

    Comments: 20 pages, 15 figures; submitted to NIMA

    Journal ref: Nucl.Instrum.Meth.A576:350-361,2007

  48. arXiv:physics/0608034  [pdf, ps, other

    physics.ins-det astro-ph nucl-ex

    Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon

    Authors: K. Ni, E. Aprile, K. L. Giboni, P. Majewski, M. Yamashita

    Abstract: Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a me… ▽ More

    Submitted 4 August, 2006; v1 submitted 3 August, 2006; originally announced August 2006.

    Journal ref: JINST1:P09004,2006

  49. arXiv:physics/0502071  [pdf, ps, other

    physics.ins-det astro-ph nucl-ex

    Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber

    Authors: K. Ni, E. Aprile, D. Day, K. L. Giboni, J. A. M. Lopes, P. Majewski, M. Yamashita

    Abstract: Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric fiel… ▽ More

    Submitted 14 February, 2005; originally announced February 2005.

    Comments: 13 pages, 8 figures

    Journal ref: Nucl.Instrum.Meth. A551 (2005) 356-363