-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Track-based alignment for the BESIII CGEM detector in the cosmic-ray test
Authors:
A. Q. Guo,
L. H. Wu,
L. L. Wang,
R. E. Mitchell,
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Y. Dong,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta
, et al. (27 additional authors not shown)
Abstract:
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical tri…
▽ More
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.
△ Less
Submitted 14 December, 2022; v1 submitted 2 November, 2022;
originally announced November 2022.
-
MPGDs for tracking and Muon detection at future high energy physics colliders
Authors:
K. Black,
A. Colaleo,
C. Aimè,
M. Alviggi,
C. Aruta,
M. Bianco,
I. Balossino,
G. Bencivenni,
M. Bertani,
A. Braghieri,
V. Cafaro,
S. Calzaferri,
M. T. Camerlingo,
V. Canale,
G. Cibinetto,
M. Corbetta,
V. D'Amico,
E. De Lucia,
M. Della Pietra,
C. Di Donato,
R. Di Nardo,
D. Domenici,
F. Errico,
P. Everaerts,
F. Fallavollita
, et al. (39 additional authors not shown)
Abstract:
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high backgro…
▽ More
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high background environments are required in order to accomplish the physics program. MPGDs offer a diversity of technologies that allow them to meet the required performance challenges at future facilities thanks to the specific advantages that each technology provides. MPGDs allow stable operation, with environmentally friendly gas mixtures, at very high background particle flux with high detection efficiency and excellent spatial resolution. These features make MPGD one of the primary choices as precise muon tracking and trigger system in general-purpose detectors at future HEP colliders. In addition, the low material budget and the flexibility of the base material make MPGDs suitable for the development of very light, full cylindrical fine tracking inner trackers at lepton colliders. On-going R&Ds aim at pushing the detector performance at the limits of each technology. We are working in continuing to consolidate the construction and stable operation of large-size detectors, able to cope with large particle fluxes. In this white paper, we describe some of the most prominent MPGD technologies, their performance measurements, the challenges faced in the most recent applications, and the areas of improvement towards efficient tracking and Muon detection at future high energy physics colliders.
△ Less
Submitted 12 March, 2022;
originally announced March 2022.
-
A Cylindrical GEM Inner Tracker for the BESIII Experiment: from Construction to Electronic Noise Studies
Authors:
Stefano Gramigna
Abstract:
This thesis reports the various phases of the life cycle of a cylindrical GEM detector, developed within the context of the CGEM-IT project. This represents the Italian proposal for the upgrade of the BESIII inner tracker, which has been suffering from aging phenomena due to the high luminosity. The construction of the detector at Frascati National Laboratories and the early phases of its commissi…
▽ More
This thesis reports the various phases of the life cycle of a cylindrical GEM detector, developed within the context of the CGEM-IT project. This represents the Italian proposal for the upgrade of the BESIII inner tracker, which has been suffering from aging phenomena due to the high luminosity. The construction of the detector at Frascati National Laboratories and the early phases of its commissioning at IHEP are described in detail. In the last two chapters, noise studies on data collected using a CGEM detector with a full readout chain near the BEPC-II interaction point will be presented, starting from the quality assurance tests of the on-detector electronics. The measurements are realized exploiting the different operative phases of the BEPC-II storage ring and aim to provide an estimate of the noise level variation due to the surrounding environment.
△ Less
Submitted 24 February, 2022;
originally announced February 2022.
-
The CGEM-IT readout chain
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
R. Bugalho,
A. Calcaterra,
S. Cerioni,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
A. Di Francesco,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
S. Garbolino,
I. Garzia,
M. Gatta
, et al. (22 additional authors not shown)
Abstract:
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output b…
▽ More
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.
△ Less
Submitted 17 August, 2021; v1 submitted 19 May, 2021;
originally announced May 2021.
-
PARSIFAL: a toolkit for triple-GEM parametrized simulation
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
S. Cerioni,
W. Cheng,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta,
G. Giraudo,
S. Gramigna
, et al. (16 additional authors not shown)
Abstract:
PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic f…
▽ More
PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic field, if present, and GEM amplification to provide the dependable triple-GEM detector response. In the design and optimization stages of this kind of detectors, simulations play an important role. Accurate and robust software programs, such as GARFIELD++, can simulate the transport of electrons and ions in a gas medium and their interaction with the electric field, but they are CPU-time consuming. The necessity to reduce the processing time while maintaining the precision of a full simulation is the main driver of this work. For a given set of geometrical and electrical settings, GARFIELD++ is run once-and-for-all to provide the input parameters for PARSIFAL. Once PARSIFAL is initialized and run, it produces the detector output, including the signal induction and the output of the electronics. The results of the analysis of the simulated data obtained with PARSIFAL are compared with the results of the experimental data collected during a testbeam: some tuning factors are applied to the simulation to improve the agreement. This paper describes the structure of the code and the methodology used to match the output to the experimental data.
△ Less
Submitted 7 June, 2023; v1 submitted 9 May, 2020;
originally announced May 2020.
-
Time performance of a triple-GEM detector at high rate
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
A. Calcaterra,
S. Cerioni,
W. Cheng,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
A. Denig,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
B. Garillon,
I. Garzia,
M. Gatta,
G. Giraudo
, et al. (23 additional authors not shown)
Abstract:
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier a…
▽ More
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.
△ Less
Submitted 10 April, 2020;
originally announced April 2020.
-
A fast and parametric digitization for triple-GEM detectors
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferrioli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (26 additional authors not shown)
Abstract:
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the…
▽ More
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.