Study of gas contaminants and interaction with materials in RPC closed loop system
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminan…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 22 March, 2013; v1 submitted 21 February, 2013;
originally announced February 2013.
-
A study of gas contaminants and interaction with materials in RPC closed loop systems
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contami…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 5 October, 2012;
originally announced October 2012.
-
Study of gas purifiers for the CMS RPC detector
Authors:
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. L. Fabbri,
F. Felli,
M. Ferrini,
M. Giardoni,
T. Greci,
A. Paolozzi,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
S. Buontempo,
A. Cimmino,
M. de Gruttola,
F Fabozzi d A. O. M. Iorio,
L. Lista,
P. Paolucci,
P. Baesso,
G. Belli,
D. Pagano,
S. P. Ratti,
A. Vicini
, et al. (4 additional authors not shown)
Abstract:
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clar…
▽ More
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.
△ Less
Submitted 26 December, 2010;
originally announced December 2010.