First measeurements in search for keV-sterile neutrino in tritium beta-decay by Troitsk nu-mass experiment
Authors:
J. N. Abdurashitov,
A. I. Belesev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
P. V. Grigorieva,
G. A. Koroteev,
N. A. Likhovid,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
I. I. Tkachev,
S. V. Zadorozhny
Abstract:
We present the first measurements of tritium beta-decay spectrum in the electron energy range 16-18.6 keV. The goal is to find distortions which may correspond to the presence of a heavy sterile neutrinos. A possible contribution of this kind would manifest itself as a kink in the spectrum with a similar shape but with end point shifted by the value of a heavy neutrino mass. We set a new upper lim…
▽ More
We present the first measurements of tritium beta-decay spectrum in the electron energy range 16-18.6 keV. The goal is to find distortions which may correspond to the presence of a heavy sterile neutrinos. A possible contribution of this kind would manifest itself as a kink in the spectrum with a similar shape but with end point shifted by the value of a heavy neutrino mass. We set a new upper limits to the neutrino mixing matrix element U^2_{e4} which improve existing limits by a factor from 2 to 5 in the mass range 0.1-2 keV.
△ Less
Submitted 21 June, 2017; v1 submitted 31 March, 2017;
originally announced March 2017.
The role of electron scattering from registration detector in a MAC-E type spectrometer
Authors:
P. V. Grigorieva,
A. A. Nozik,
V. S. Pantuev,
A. K. Skasyrskaya
Abstract:
There is a proposal to search for a sterile neutrino in a few keV mass range by the "Troitsk nu-mass" facility. In order to estimate sterile neutrino mixing one needs to make precision spectrum measurements well below the endpoint using the existing electrostatic spectrometer with a magnetic adiabatic collimation, or MAC-E filter. The expected signature will be a kink in the electron energy spectr…
▽ More
There is a proposal to search for a sterile neutrino in a few keV mass range by the "Troitsk nu-mass" facility. In order to estimate sterile neutrino mixing one needs to make precision spectrum measurements well below the endpoint using the existing electrostatic spectrometer with a magnetic adiabatic collimation, or MAC-E filter. The expected signature will be a kink in the electron energy spectrum in tritium beta-decay. In this article we consider the systematic effect of electron backscattering on the detector used in the spectrometer. For this purpose we provide a set of Monte-Carlo simulation results of electron backscattering on a silicon detector with a thin golden window with realistic electric and magnetic fields in the spectrometer. We have found that the probability of such an effect reaches up to 20-30\%. The scattered electron could be reflected backwards to the detector by electrostatic field or by magnetic mirror. There is also a few percent probability to escape from the spectrometer through its entrance. A time delay between the scattering moment on the detector and the return of the reflected electron can reach a couple of microseconds in the Troitsk spectrometer. Such estimations are critical for the planning upgrades of the detector and the registration electronics.
△ Less
Submitted 19 November, 2015;
originally announced November 2015.