Destructive breakdown studies of irradiated LGADs at beam tests for the ATLAS HGTD
Authors:
L. A. Beresford,
D. E. Boumediene,
L. Castillo García,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
H. El Jarrari,
A. Eshkevarvakili,
C. Grieco,
S. Grinstein,
S. Guindon,
A. Howard,
G. Kramberger,
O. Kurdysh,
R. Mazini,
M. Missio,
M. Morenas,
O. Perrin,
V. Raskina,
G. Saito,
S. Trincaz-Duvoid
Abstract:
In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from…
▽ More
In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from various producers were tested in two test beam facilities, DESY (Hamburg) and CERN-SPS (Geneva), as part of ATLAS High Granularity Timing Detector (HGTD) beam tests. The samples were placed in the beam and kept under bias over a long period of time in order to reach a high number of particles crossing each sensor. Both beam tests lead to a similar conclusion, that these destructive events begin to occur when the average electric field in the sensor becomes larger than 12 Volts per micrometre.
△ Less
Submitted 14 July, 2023; v1 submitted 21 June, 2023;
originally announced June 2023.
-
Performance of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector
Authors:
C. Agapopoulou,
L. A. Beresford,
D. E. Boumediene,
L. Castillo García,
S. Conforti,
C. de la Taille,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
P. Dinaucourt,
A. Falou,
V. Gautam,
D. Gong,
C. Grieco,
S. Grinstein,
S. Guindon,
A. Howard,
O. Kurdysh,
E. Kuwertz,
C. Li,
N. Makovec,
B. Markovic,
G. Martin-Chassal,
R. Mazzini,
C. Milke,
M. Morenas
, et al. (12 additional authors not shown)
Abstract:
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (t…
▽ More
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (transimpedance and voltage) were implemented and tested. The ASIC was characterised both alone and as a module when connected to a 5$\times$5-pad array of LGAD sensors. In calibration measurements, the ASIC operating alone was found to satisfy the technical requirements for the project, with similar performances for both preamplifier types. In particular, the jitter was found to be 15$\pm$1~ps (35$\pm$1~ps) for an injected charge of 10~fC (4~fC). A degradation in performance was observed when the ASIC was connected to the LGAD array. This is attributed to digital couplings at the entrance of the preamplifiers. When the ASIC is connected to the LGAD array, the lowest detectable charge increased from 1.5~fC to 3.4~fC. As a consequence, the jitter increased for an injected charge of 4~fC. Despite this increase, ALTIROC1 still satisfies the maximum jitter specification (below 65~ps) for the HGTD project. This coupling issue also affects the time over threshold measurements and the time-walk correction can only be performed with transimpedance preamplifiers. Beam test measurements with a pion beam at CERN were also undertaken to evaluate the performance of the module. The best time resolution obtained using only ALTIROC TDC data was 46.3$\pm$0.7~ps for a restricted time of arrival range where the coupling issue is minimized. The residual time-walk contribution is equal to 23~ps and is the dominant electronic noise contribution to the time resolution at 15~fC.
△ Less
Submitted 25 July, 2023; v1 submitted 15 June, 2023;
originally announced June 2023.
-
Performance in beam tests of Carbon-enriched irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector
Authors:
S. Ali,
H. Arnold,
S. L. Auwens,
L. A. Beresford,
D. E. Boumediene,
A. M. Burger,
L. Cadamuro,
L. Castillo García,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
D. Dannheim,
V. Dao,
A. Gabrielli,
Y. El Ghazali,
H. El Jarrari,
V. Gautam,
S. Grinstein,
J. Guimarães da Costa,
S. Guindon,
X. Jia,
G. Kramberger,
Y. Liu,
K. Ma,
N. Makovec,
S. Manzoni
, et al. (12 additional authors not shown)
Abstract:
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation env…
▽ More
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation environment, LGADs have been optimized by adding carbon in the gain layer, thus reducing the acceptor removal rate after irradiation. Performances of several carbon-enriched LGAD sensors from different vendors, and irradiated with high fluences of 1.5 and 2.5 x 10^15 neq/cm2, have been measured in beam test campaigns during the years 2021 and 2022 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few um. Collected charge, time resolution and hit efficiency measurements are presented. In addition, the efficiency uniformity is also studied as a function of the position of the incident particle inside the sensor pad.
△ Less
Submitted 17 March, 2023; v1 submitted 14 March, 2023;
originally announced March 2023.
-
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
Authors:
S. Xiao,
S. Alderweireldt,
S. Ali,
C. Allaire,
C. Agapopoulou,
N. Atanov,
M. K. Ayoub,
G. Barone,
D. Benchekroun,
A. Buzatu,
D. Caforio,
L. Castillo García,
Y. Chan,
H. Chen,
V. Cindro,
L. Ciucu,
J. Barreiro Guimarães da Costa,
H. Cui,
F. Davó Miralles,
Y. Davydov,
G. d'Amen,
C. de la Taille,
R. Kiuchi,
Y. Fan,
A. Falou
, et al. (75 additional authors not shown)
Abstract:
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated wi…
▽ More
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
Authors:
X. Shi,
M. K. Ayoub,
J. Barreiro Guimarães da Costa,
H. Cui,
R. Kiuchi,
Y. Fan,
S. Han,
Y. Huang,
M. Jing,
Z. Liang,
B. Liu,
J. Liu,
F. Lyu,
B. Qi,
K. Ran,
L. Shan,
L. Shi,
Y. Tan,
K. Wu,
S. Xiao,
T. Yang,
Y. Yang,
C. Yu,
M. Zhao,
X. Zhuang
, et al. (52 additional authors not shown)
Abstract:
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the co…
▽ More
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
Authors:
X. Yang,
S. Alderweireldt,
N. Atanov,
M. K. Ayoub,
J. Barreiro Guimaraes da Costa,
L. Castillo Garcia,
H. Chen,
S. Christie,
V. Cindro,
H. Cui,
G. D'Amen,
Y. Davydov,
Y. Y. Fan,
Z. Galloway,
J. J. Ge,
C. Gee,
G. Giacomini,
E. L. Gkougkousis,
C. Grieco,
S. Grinstein,
J. Grosse-Knetter,
S. Guindon,
S. Han,
A. Howard,
Y. P. Huang
, et al. (54 additional authors not shown)
Abstract:
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising…
▽ More
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors
Authors:
C. Agapopoulou,
S. Blin,
A. Blot,
L. Castillo Garcia,
M. Chmeissani,
S. Conforti di Lorenzo,
C. de La Taille,
P. Dinaucourt,
A. Fallou,
J. Garcia Rodriguez,
V. Gkougkousis,
C. Grieco,
S. Grinstein,
S. Guindon,
N. Makovec,
G. Martin-Chassard,
G. Pellegrini,
A. Rummler,
S. Sacerdoti,
N. Seguin Moreau,
L. Serin,
A. Tricoli
Abstract:
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the perfo…
▽ More
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the performance of the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2$\times$2 LGAD array of 1.1$\times$1.1 mm$^2$ pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect that arises from the different response of the preamplifier for various injected charges can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.
△ Less
Submitted 7 July, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector
Authors:
C. Allaire,
J. Benitez,
M. Bomben,
G. Calderini,
M. Carulla,
E. Cavallaro,
A. Falou,
D. Flores,
P. Freeman,
Z. Galloway,
E. L. Gkougkousis,
H. Grabas,
S. Grinstein,
B. Gruey,
S. Guindon,
A. M. Henriques Correia,
S. Hidalgo,
A. Kastanas,
C. Labitan,
D. Lacour,
J. Lange,
F. Lanni,
B. Lenzi,
Z. Luce,
N. Makovec
, et al. (19 additional authors not shown)
Abstract:
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sen…
▽ More
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm^2 or 3x3 mm^2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in Autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few μm. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm^2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.
△ Less
Submitted 9 August, 2018; v1 submitted 2 April, 2018;
originally announced April 2018.