-
Detection of carbon monoxide using a polarization-multiplexed erbium dual-comb fiber laser
Authors:
P. E. Collin Aldia,
Jiayang Chen,
Jonas K. C. Ballentin,
Lukas W. Perner,
O. H. Heckl
Abstract:
We present a compact, reliable, and robust free-running all-polarization-maintaining erbium (Er) single-cavity dual-comb laser generated via polarization multiplexing with gain sharing. Polarization multiplexing exploits the fast and slow axes of the fiber, while modelocking is achieved through a nonlinear amplifying loop mirror scheme using readily available components. The laser operates at a re…
▽ More
We present a compact, reliable, and robust free-running all-polarization-maintaining erbium (Er) single-cavity dual-comb laser generated via polarization multiplexing with gain sharing. Polarization multiplexing exploits the fast and slow axes of the fiber, while modelocking is achieved through a nonlinear amplifying loop mirror scheme using readily available components. The laser operates at a repetition rate of around 74.74 MHz with a tuning capability in the difference in repetition rates from 500 Hz to 200 kHz. This tunability makes the system more flexible for dual-comb spectroscopy experiments. Consequently, using this laser, we demonstrated a proof-of-principle dual-comb spectroscopy of carbon monoxide (CO), operating without any active stabilization.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Fast Gain Dynamics in Interband Cascade Lasers
Authors:
Florian Pilat,
Andreas Windischhofer,
Maximilian Beiser,
Vito F. Pecile,
Elizaveta Gangrskaia,
Audrius Pugžlys,
Robert Weih,
Johannes Koeth,
Andrius Baltuška,
Oliver H. Heckl,
Benedikt Schwarz
Abstract:
Interband Cascade Lasers (ICL) have matured into a versatile technological platform in the mid-infrared spectral domain. To broaden their applicability even further, ongoing research pursues the emission of ultrashort pulses. The most promising approach is passive mode-locking with a fast saturable absorber. However, despite vast attempts no passive mode-locked ICL has been demonstrated up to date…
▽ More
Interband Cascade Lasers (ICL) have matured into a versatile technological platform in the mid-infrared spectral domain. To broaden their applicability even further, ongoing research pursues the emission of ultrashort pulses. The most promising approach is passive mode-locking with a fast saturable absorber. However, despite vast attempts no passive mode-locked ICL has been demonstrated up to date. In this study we perform pump-probe measurements on the ICL gain and show that its dynamics are mainly ($\sim$70%) governed by a fast recovery time of 2 ps. Our findings explain why passive mode-locking has not succeeded so far, shedding a new light on ICL dynamics as we propose strategies to overcome the current limitations.
△ Less
Submitted 16 May, 2024;
originally announced May 2024.
-
Low Phase Noise, Record-High Power Optical Parametric Oscillator Tunable from 2.7-4.7 μm for Metrology Applications
Authors:
Vito F. Pecile,
Michael Leskowschek,
Norbert Modsching,
Valentin J. Wittwer,
Thomas Südmeyer,
Oliver H. Heckl
Abstract:
Within the domain of optical frequency comb systems operating in the mid-infrared, extensive exploration has been undertaken regarding critical parameters such as stabilization, coherence, or spectral tunability. Despite this, certain essential parameters remain inadequately addressed, particularly concerning the light source prerequisites for advanced spectroscopy techniques operating in the 3-5…
▽ More
Within the domain of optical frequency comb systems operating in the mid-infrared, extensive exploration has been undertaken regarding critical parameters such as stabilization, coherence, or spectral tunability. Despite this, certain essential parameters remain inadequately addressed, particularly concerning the light source prerequisites for advanced spectroscopy techniques operating in the 3-5 $μ$m spectral region. Specifically, the necessity for high simultaneous stability of average power, spectral shape, and temporal properties, alongside requirements for excellent beam quality and high powers of several Watts, emerges for applications like cavity-enhanced Doppler-free saturation spectroscopy. Existing systems fall short of meeting these rigorous criteria. This study delves into the metrology aspects of an optical parametric oscillator system, with a particular emphasis on its suitability for powerhungry metrology applications. Notably, the highest average power reported in the 3-5 $μ$m region, reaching 10.3W for the idler output at 3.1 $μ$m, is achieved. Additionally, new aspects, like the analysis of idler phase noise and beam quality and the onset of higher order modes are discussed. These findings represent a significant advancement towards the realization of highly-stable, metrologygrade frequency combs in the mid-infrared, thereby facilitating precision spectroscopy techniques previously constrained by light source average powers and quality limitations.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
Theory of angular momentum transfer from light to molecules
Authors:
Mikhail Maslov,
Georgios M. Koutentakis,
Mateja Hrast,
Oliver H. Heckl,
Mikhail Lemeshko
Abstract:
We present a theory describing interaction of structured light, such as light carrying orbital angular momentum, with molecules. The light-matter interaction Hamiltonian we derive is expressed through couplings between spherical gradients of the electric field and the (transition) multipole moments of a particle of any non-trivial rotation point group. Our model can therefore accommodate for an ar…
▽ More
We present a theory describing interaction of structured light, such as light carrying orbital angular momentum, with molecules. The light-matter interaction Hamiltonian we derive is expressed through couplings between spherical gradients of the electric field and the (transition) multipole moments of a particle of any non-trivial rotation point group. Our model can therefore accommodate for an arbitrary complexity of the molecular and electric field structure, and can be straightforwardly extended to atoms or nanostructures. Applying this framework to ro-vibrational spectroscopy of molecules, we uncover the general mechanism of angular momentum exchange between the spin and orbital angular momenta of light, molecular rotation and its center-of-mass motion. We show that the non-zero vorticity of Laguerre-Gaussian beams can strongly enhance certain ro-vibrational transitions that are considered forbidden in the case of non-helical light. We discuss the experimental requirements for the observation of these forbidden transitions in state-of-the-art spatially-resolved spectroscopy measurements.
△ Less
Submitted 22 April, 2024; v1 submitted 29 September, 2023;
originally announced October 2023.
-
Simultaneous Measurement of Mid-Infrared Refractive Indices in Thin-Film Heterostructures: Methodology and Results for GaAs/AlGaAs
Authors:
Lukas W. Perner,
Gar-Wing Truong,
David Follman,
Maximilian Prinz,
Georg Winkler,
Stephan Puchegger,
Garrett D. Cole,
Oliver H. Heckl
Abstract:
We present our results for simultaneous measurement of the refractive indices of gallium arsenide (GaAs) and aluminum gallium arsenide (Al$_\mathrm{x}$Ga$_\mathrm{1-x}$As) from $2.0$ to $7.1\,\mathrm{μm}$ ($5000$ to $1400\,\mathrm{cm^{-1}}$). We obtain these values from a monocrystalline superlattice Bragg mirror of excellent purity (background doping $\leq 1 \times 10^{-14}\,\mathrm{cm^{-3}}$), g…
▽ More
We present our results for simultaneous measurement of the refractive indices of gallium arsenide (GaAs) and aluminum gallium arsenide (Al$_\mathrm{x}$Ga$_\mathrm{1-x}$As) from $2.0$ to $7.1\,\mathrm{μm}$ ($5000$ to $1400\,\mathrm{cm^{-1}}$). We obtain these values from a monocrystalline superlattice Bragg mirror of excellent purity (background doping $\leq 1 \times 10^{-14}\,\mathrm{cm^{-3}}$), grown via molecular beam epitaxy. To recover the refractive indices over such a broad wavelength range, we fit a dispersion model for each material. In a novel combination of well-established methods, we measure both a photometrically accurate transmittance spectrum of the Bragg mirror via Fourier-transform infrared spectrometry and the individual physical layer thicknesses of the structure via scanning electron microscopy. To infer the uncertainty of the refractive index values, we estimate relevant measurement uncertainties and propagate them via a Monte-Carlo method. This highly-adaptable approach conclusively yields propagated relative uncertainties on the order of $10^{-4}$ over the measured spectral range for both GaAs and Al$_{0.929}$Ga$_{0.071}$As. The fitted model can also approximate the refractive index for MBE-grown Al$_\mathrm{x}$Ga$_\mathrm{1-x}$As for $0\leq x \leq 1$. Both these updated values and the measurement approach will be essential in the design, fabrication, and characterization of next-generation active and passive optical devices in a spectral region that is of high interest in many fields, e.g., laser design and cavity-enhanced spectroscopy in the mid-infrared spectral region.
△ Less
Submitted 16 May, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
Precise Measurement of Refractive Indices in Thin Film Heterostructures
Authors:
Lukas W. Perner,
Gar-Wing Truong,
David Follman,
Maximilian Prinz,
Georg Winkler,
Stephan Puchegger,
Garrett D. Cole,
Oliver H. Heckl
Abstract:
We present a robust, precise, and accurate method to simultaneously measure the refractive indices of two transparent materials within an interference coating. This is achieved by measuring both a photometrically accurate transmittance spectrum and the as-grown individual layer thicknesses of a thin-film multilayer structure. These measurements are used for a TMM-based curve-fitting routine which…
▽ More
We present a robust, precise, and accurate method to simultaneously measure the refractive indices of two transparent materials within an interference coating. This is achieved by measuring both a photometrically accurate transmittance spectrum and the as-grown individual layer thicknesses of a thin-film multilayer structure. These measurements are used for a TMM-based curve-fitting routine which extracts the refractive indices and their measurement uncertainties via a Monte-Carlo-type error propagation. We demonstrate the performance of this approach by experimentally measuring the refractive indices of both, GaAs and Al$_{0.929}$Ga$_{0.071}$As, as present in an epitaxial distributed Bragg reflector. A variety of devices can be used to obtain the transmittance spectrum (e.g., FTIR, grating-based spectrophotometer) and layer thicknesses (e.g., SEM, TEM, AFM), the discussed approach is readily adaptable to virtually any wavelength region and many transparent material combinations of interest. The subsequent model-fitting approach yields refractive index values with $10^{-4}$-level uncertainty for both materials.
△ Less
Submitted 18 January, 2023;
originally announced January 2023.
-
Mid-infrared supermirrors with finesse exceeding 400 000
Authors:
G. -W. Truong,
L. W. Perner,
D. M. Bailey,
G. Winkler,
S. B. Cataño-Lopez,
V. J. Wittwer,
T. Sudmeyer,
C. Nguyen,
D. Follman,
A. J. Fleisher,
O. H. Heckl,
G. D. Cole
Abstract:
For trace gas sensing and precision spectroscopy, optical cavities incorporating low-loss mirrors are indispensable for path length and optical intensity enhancement. Optical interference coatings in the visible and near-infrared (NIR) spectral regions have achieved total optical losses below 2 parts per million (ppm), enabling a cavity finesse in excess of 1 million. However, such advancements ha…
▽ More
For trace gas sensing and precision spectroscopy, optical cavities incorporating low-loss mirrors are indispensable for path length and optical intensity enhancement. Optical interference coatings in the visible and near-infrared (NIR) spectral regions have achieved total optical losses below 2 parts per million (ppm), enabling a cavity finesse in excess of 1 million. However, such advancements have been lacking in the mid-infrared (MIR), despite substantial scientific interest. Here, we demonstrate a significant breakthrough in high-performance MIR mirrors, reporting substrate-transferred single-crystal interference coatings capable of cavity finesse values from 200 000 to 400 000 near 4.5 um, with excess optical losses (scatter and absorption) below 5 ppm. In a first proof-of-concept demonstration, we achieve the lowest noise-equivalent absorption in a linear cavity ring-down spectrometer normalized by cavity length. This substantial improvement in performance will unlock a rich variety of MIR applications for atmospheric transport and environmental sciences, detection of fugitive emissions, process gas monitoring, breath-gas analysis, and verification of biogenic fuels and plastics.
△ Less
Submitted 31 July, 2023; v1 submitted 14 September, 2022;
originally announced September 2022.
-
Simple approach for extending the ambiguity-free-range of dual-comb ranging
Authors:
Jakob Fellinger,
Georg Winkler,
P. E. Collin Aldia,
Aline S. Mayer,
Valentina Shumakova,
Lukas W. Perner,
Vito F. Pecile,
Tadeusz Martynkien,
Pawel Mergo,
Grzegorz Sobo,
Oliver H. Heckl
Abstract:
Dual-comb (DC) ranging is an established method for high-precision and high-accuracy distance measurements. It is, however, restricted by an inherent length ambiguity and the requirement for complex control loops for comb stabilization. Here, we present a simple approach for expanding the ambiguity-free measurement length of dual-comb ranging by exploiting the intrinsic intensity modulation of a s…
▽ More
Dual-comb (DC) ranging is an established method for high-precision and high-accuracy distance measurements. It is, however, restricted by an inherent length ambiguity and the requirement for complex control loops for comb stabilization. Here, we present a simple approach for expanding the ambiguity-free measurement length of dual-comb ranging by exploiting the intrinsic intensity modulation of a single-cavity dualcolor DC for simultaneous time-of-flight a nd D C distance measurements. This measurement approach enables the measurement of distances up to several hundred km with the precision and accuracy of a dualcomb interferometric setup while providing a high data acquisition rate (~2 kHz) and requiring only the repetition rate of one of the combs to be stabilized.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Compact, all-PM fiber integrated and alignment-free ultrafast Yb:fiber NALM laser with sub-femtosecond timing jitter
Authors:
Yuxuan Ma,
Sarper H. Salman,
Chen Li,
Christoph Mahnke,
Yi Hua,
Stefan Droste,
Jakob Fellinger,
Aline S. Mayer,
Oliver H. Heckl,
Christoph M. Heyl,
Ingmar Hartl
Abstract:
We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design paramet…
▽ More
We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design parameters were determined by numerically simulating the pulse evolution in the oscillator and by analyzing their impact on the laser performance. Experimentally, we achieved an 88 fs compressed pulse duration with sub-fs timing jitter at 54 MHz repetition rate and 51 mW of output power with 5.5 * 10-5 [20 Hz, 1 MHz] integrated relative intensity noise (RIN). Furthermore, we demonstrate tight phase-locking of the laser's carrier-envelope offset frequency (fceo) to a stable radio frequency (RF) reference and of one frequency comb tooth to a stable optical reference at 291 THz.
△ Less
Submitted 8 January, 2021;
originally announced January 2021.
-
Mid-infrared monocrystalline interference coatings with excess optical loss below 10 ppm
Authors:
G. Winkler,
L. W. Perner,
G. -W. Truong,
G. Zhao,
D. Bachmann,
A. S. Mayer,
J. Fellinger,
D. Follman,
P. Heu,
C. Deutsch,
D. M. Bailey,
H. Peelaers,
S. Puchegger,
A. J. Fleisher,
G. D. Cole,
O. H. Heckl
Abstract:
We present high-reflectivity substrate-transferred single-crystal GaAs/AlGaAs interference coatings at a center wavelength of 4.54 um with record-low excess optical loss below 10 parts per million. These high-performance mirrors are realized via a novel microfabrication process that differs significantly from the production of amorphous multilayers generated via physical vapor deposition processes…
▽ More
We present high-reflectivity substrate-transferred single-crystal GaAs/AlGaAs interference coatings at a center wavelength of 4.54 um with record-low excess optical loss below 10 parts per million. These high-performance mirrors are realized via a novel microfabrication process that differs significantly from the production of amorphous multilayers generated via physical vapor deposition processes. This new process enables reduced scatter loss due to the low surface and interfacial roughness, while low background doping in epitaxial growth ensures strongly reduced absorption. We report on a suite of optical measurements, including cavity ring-down, transmittance spectroscopy, and direct absorption tests to reveal the optical losses for a set of prototype mirrors. In the course of these measurements, we observe a unique polarization-orientation-dependent loss mechanism which we attribute to elastic anisotropy of these strained epitaxial multilayers. A future increase in layer count and a corresponding reduction of transmittance will enable optical resonators with a finesse in excess of 100 000 in the mid-infrared spectral region, allowing for advances in high resolution spectroscopy, narrow-linewidth laser stabilization, and ultrasensitive measurements of various light-matter interactions.
△ Less
Submitted 10 September, 2020;
originally announced September 2020.
-
Flexible all-PM NALM Yb:fiber laser design for frequency comb applications: operation regimes and their noise properties
Authors:
Aline S. Mayer,
Wilfrid Grosinger,
Jakob Fellinger,
Georg Winkler,
Lukas W. Perner,
Stefan Droste,
Sarper H. Salman,
Chen Li,
Christoph M. Heyl,
Ingmar Hartl,
Oliver H. Heckl
Abstract:
We present a flexible all-polarization-maintaining (PM) mode-locked ytterbium (Yb):fiber laser based on a nonlinear amplifying loop mirror (NALM). In addition to providing detailed design considerations, we discuss the different operation regimes accessible by this versatile laser architecture and experimentally analyze five representative mode-locking states. These five states were obtained in a…
▽ More
We present a flexible all-polarization-maintaining (PM) mode-locked ytterbium (Yb):fiber laser based on a nonlinear amplifying loop mirror (NALM). In addition to providing detailed design considerations, we discuss the different operation regimes accessible by this versatile laser architecture and experimentally analyze five representative mode-locking states. These five states were obtained in a 78-MHz configuration at different intracavity group delay dispersion (GDD) values ranging from anomalous (-0.035 ps$^2$) to normal (+0.015 ps$^2$). We put a particular focus on the characterization of the intensity noise as well as the free-running linewidth of the carrier-envelope-offset (CEO) frequency as a function of the different operation regimes. We observe that operation points far from the spontaneous emission peak of Yb (~1030 nm) and close to zero intracavity dispersion can be found, where the influence of pump noise is strongly suppressed. For such an operation point, we show that a CEO linewidth of less than 10-kHz at 1 s integration can be obtained without any active stabilization.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Tunable dual-comb from an all-polarization-maintaining single-cavity dual-color Yb:fiber laser
Authors:
Jakob Fellinger,
Aline S. Mayer,
Georg Winkler,
Wilfrid Grosinger,
Gar-Wing Truong,
Stefan Droste,
Chen Li,
Christoph M. Heyl,
Ingmar Hartl,
Oliver H. Heckl
Abstract:
We demonstrate dual-comb generation from an all-polarization-maintaining dual-color ytterbium (Yb) fiber laser. Two pulse trains with center wavelengths at 1030 nm and 1060 nm respectively are generated within the same laser cavity with a repetition rate around 77 MHz. Dual-color operation is induced using a tunable mechanical spectral filter, which cuts the gain spectrum into two spectral regions…
▽ More
We demonstrate dual-comb generation from an all-polarization-maintaining dual-color ytterbium (Yb) fiber laser. Two pulse trains with center wavelengths at 1030 nm and 1060 nm respectively are generated within the same laser cavity with a repetition rate around 77 MHz. Dual-color operation is induced using a tunable mechanical spectral filter, which cuts the gain spectrum into two spectral regions that can be independently mode-locked. Spectral overlap of the two pulse trains is achieved outside the laser cavity by amplifying the 1030-nm pulses and broadening them in a nonlinear fiber. Spatially overlapping the two arms on a simple photodiode then generates a down-converted radio frequency comb. The difference in repetition rates between the two pulse trains and hence the line spacing of the down-converted comb can easily be tuned in this setup. This feature allows for a flexible adjustment of the tradeoff between non-aliasing bandwidth vs. measurement time in spectroscopy applications. Furthermore, we show that by fine-tuning the center-wavelengths of the two pulse trains, we are able to shift the down-converted frequency comb along the radio-frequency axis. The usability of this dual-comb setup is demonstrated by measuring the transmission of two different etalons while the laser is completely free-running.
△ Less
Submitted 7 June, 2019;
originally announced June 2019.
-
Phase-stabilized 100 mW frequency comb near 10 μm
Authors:
Kana Iwakuni,
Gil Porat,
Thinh Q. Bui,
Bryce J. Bjork,
Stephen B. Schoun,
Oliver H. Heckl,
Martin E. Fermann,
Jun Ye
Abstract:
Long-wavelength mid-infrared frequency combs with high power and flexible tunability are highly desired for molecular spectroscopy, including investigation of large molecules such as C60. We present a high power, phase-stabilized frequency comb near 10 μm, generated by a synchronously-pumped, singly-resonant optical parametric oscillator (OPO) based on AgGaSe2. The OPO can be continuously tuned fr…
▽ More
Long-wavelength mid-infrared frequency combs with high power and flexible tunability are highly desired for molecular spectroscopy, including investigation of large molecules such as C60. We present a high power, phase-stabilized frequency comb near 10 μm, generated by a synchronously-pumped, singly-resonant optical parametric oscillator (OPO) based on AgGaSe2. The OPO can be continuously tuned from 8.4 to 9.5 μm, with a maximum average idler power of 100 mW at the center wavelength of 8.5 μm. Both the repetition rate (frep) and the carrier-envelop offset frequency (fceo) of the idler wave are phase-locked to microwave signals referenced to a Cs clock. We describe the detailed design and construction of the frequency comb, and discuss potential applications for precise and sensitive direct frequency comb spectroscopy.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
OD + CO -> D + CO2 Branching Kinetics Probed with Time-Resolved Frequency Comb Spectroscopy
Authors:
Thinh Q. Bui,
Bryce J. Bjork,
P. Bryan Changala,
Oliver H. Heckl,
Ben Spaun,
Jun Ye
Abstract:
Time-resolved direct frequency comb spectroscopy (TRFCS) was used to study the kinetics of the deuterated analogue of the OH+CO->H+CO2 reaction, which is important for atmospheric and combustion chemistry. Complementing our recent work on quantifying the formation rate of the transient trans-DOCO radical, we report measurements of the kinetics of the activated product channel, D+CO2, at room tempe…
▽ More
Time-resolved direct frequency comb spectroscopy (TRFCS) was used to study the kinetics of the deuterated analogue of the OH+CO->H+CO2 reaction, which is important for atmospheric and combustion chemistry. Complementing our recent work on quantifying the formation rate of the transient trans-DOCO radical, we report measurements of the kinetics of the activated product channel, D+CO2, at room temperature. Simultaneous measurements of the time-dependence of OD and CO2 concentrations allowed us to directly determine the formation rate, branching yield, and dependence on pressure and bath gas of the activated product. Together with the trans-DOCO formation rate, these new measurements provide absolute yields of branching channels for both products of OD+CO in the low-pressure limit.
△ Less
Submitted 3 January, 2017;
originally announced January 2017.
-
Three Photon Absorption in Optical Parametric Oscillators Based on OP-GaAs
Authors:
Oliver H. Heckl,
Bryce J. Bjork,
Georg Winkler,
P. Bryan Changala,
Ben Spaun,
1 Gil Porat,
Thinh Q. Bui,
Kevin F. Lee,
Jie Jiang,
Martin Fermann,
Peter G. Schunemann,
Jun Ye
Abstract:
We report on the first singly-resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 $μ$m within ~3 dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synch…
▽ More
We report on the first singly-resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 $μ$m within ~3 dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synchronously pumped OPO based on OP-GaAs. We discovered strong three photon absorption with a coefficient of 0.35 ${\pm}$ 0.06 cm${^3}$/GW${^2}$ for our OP-GaAs sample, which limits the output power of these OPOs as mid-IR light sources. We present a detailed study of the three photon loss on the performance of both the SR and DR-OPOs, and compare them to those without this loss mechanism.
△ Less
Submitted 2 September, 2016;
originally announced September 2016.
-
Direct Frequency Comb Measurement of OD + CO -> DOCO Kinetics
Authors:
Bryce J. Bjork,
Thinh Q. Bui,
Oliver H. Heckl,
P. Bryan Changala,
Ben Spaun,
Paula Heu,
David Follman,
Christoph Deutsch,
Garrett D. Cole,
Markus Aspelmeyer,
Mitchio Okumura,
Jun Ye
Abstract:
The kinetics of the OH + CO reaction, fundamental to both atmospheric and combustion chemistry, are complex due to the formation of the HOCO intermediate. Despite extensive studies on this reaction, HOCO has not been observed at thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we…
▽ More
The kinetics of the OH + CO reaction, fundamental to both atmospheric and combustion chemistry, are complex due to the formation of the HOCO intermediate. Despite extensive studies on this reaction, HOCO has not been observed at thermal reaction conditions. Exploiting the sensitive, broadband, and high-resolution capabilities of time-resolved cavity-enhanced direct frequency comb spectroscopy, we observe OD + CO reaction kinetics with the detection of stabilized trans-DOCO, the deuterated analogue of trans-HOCO, and its yield. By simultaneously measuring the time-dependent concentrations of both trans-DOCO and OD species, we observe unambiguous low-pressure termolecular dependence on the reaction rate coefficients for both N2 and CO bath gases. These results confirm the HOCO formation mechanism and quantify its yield.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
High-performance near- and mid-infrared crystalline coatings
Authors:
Garrett D. Cole,
Wei Zhang,
Bryce J. Bjork,
David Follman,
Paula Heu,
Christoph Deutsch,
Lindsay Sonderhouse,
John Robinson,
Chris Franz,
Alexei Alexandrovski,
Mark Notcutt,
Oliver H. Heckl,
Jun Ye,
Markus Aspelmeyer
Abstract:
Substrate-transferred crystalline coatings have recently emerged as a groundbreaking new concept in optical interference coatings. Building upon our initial demonstration of this technology, we have now realized significant improvements in the limiting optical performance of these novel single-crystal $GaAs/Al_{x}Ga_{1-x}As$ multilayers. In the near-infrared (NIR), for coating center wavelengths s…
▽ More
Substrate-transferred crystalline coatings have recently emerged as a groundbreaking new concept in optical interference coatings. Building upon our initial demonstration of this technology, we have now realized significant improvements in the limiting optical performance of these novel single-crystal $GaAs/Al_{x}Ga_{1-x}As$ multilayers. In the near-infrared (NIR), for coating center wavelengths spanning 1064 to 1560 nm, we have reduced the excess optical losses (scatter + absorption) to levels as low as 3 parts per million, enabling the realization of a cavity finesse exceeding $3\times 10^{5}$ at the telecom-relevant wavelength range near 1550 nm. Moreover, we demonstrate the direct measurement of sub-ppm optical absorption at 1064 nm. Concurrently, we investigate the mid-IR (MIR) properties of these coatings and observe exceptional performance for first attempts in this important wavelength region. Specifically, we verify excess losses at the hundred ppm level for wavelengths of 3300 and 3700 nm. Taken together, our NIR optical losses are now fully competitive with ion beam sputtered multilayer coatings, while our first prototype MIR optics have already reached state-of-the-art performance levels for reflectors covering this portion of the fingerprint region for optical gas sensing. Mirrors fabricated with our crystalline coating technique exhibit the lowest mechanical loss, and thus the lowest Brownian noise, the highest thermal conductivity, and, potentially, the widest spectral coverage of any "supermirror" technology in a single material platform. Looking ahead, we see a bright future for crystalline coatings in applications requiring the ultimate levels of optical, thermal, and optomechanical performance
△ Less
Submitted 22 March, 2016;
originally announced April 2016.
-
Continuous probe of cold complex molecules with infrared frequency comb spectroscopy
Authors:
Ben Spaun,
P. Bryan Changala,
David Patterson,
Bryce J. Bjork,
Oliver H. Heckl,
John M. Doyle,
Jun Ye
Abstract:
Cavity-enhanced frequency comb spectroscopy for molecule detection in the mid-infrared powerfully combines high resolution, high sensitivity, and broad spectral coverage. However, this technique, and essentially all spectroscopic methods, is limited in application to relatively small, simple molecules. Here we integrate comb spectroscopy with continuous, cold samples of molecules produced via buff…
▽ More
Cavity-enhanced frequency comb spectroscopy for molecule detection in the mid-infrared powerfully combines high resolution, high sensitivity, and broad spectral coverage. However, this technique, and essentially all spectroscopic methods, is limited in application to relatively small, simple molecules. Here we integrate comb spectroscopy with continuous, cold samples of molecules produced via buffer gas cooling, thus enabling the study of significantly more complex molecules. We report simultaneous gains in resolution, sensitivity, and bandwidth and demonstrate this combined capability with the first rotationally resolved direct absorption spectra in the CH stretch region of several complex molecules. These include nitromethane (CH$_3$NO$_2$), a model system that presents challenging questions to the understanding of large amplitude vibrational motion, as well as several large organic molecules with fundamental spectroscopic and astrochemical relevance, including naphthalene (C$_{10}$H$_8$), adamantane (C$_{10}$H$_{16}$), and hexamethylenetetramine (C$_{6}$N$_4$H$_{12}$). This general spectroscopic tool has the potential to significantly impact the field of molecular spectroscopy, simultaneously improving efficiency, spectral resolution, and specificity by orders of magnitude. This realization could open up new molecular species and new kinetics for precise investigations, including the study of complex molecules, weakly bound clusters, and cold chemistry.
△ Less
Submitted 28 January, 2016;
originally announced January 2016.