New Limits on Double Electron Capture of $^{40}$Ca and $^{180}$W
Authors:
G. Angloher,
M. Bauer,
P. Bauer,
I. Bavykina,
A. Bento,
C. Bucci,
L. Canonica,
C. Ciemniak,
X. Defay,
G. Deuter,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
P. Huff,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
J. Loebell
, et al. (31 additional authors not shown)
Abstract:
We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Dependin…
▽ More
We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these values improve the currently best limits by a factor of $\sim$1.4-30.
△ Less
Submitted 18 August, 2016; v1 submitted 28 April, 2016;
originally announced April 2016.
-
Results on low mass WIMPs using an upgraded CRESST-II detector
Authors:
CRESST Collaboration,
G. Angloher,
A. Bento,
C. Bucci,
L. Canonica,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
P. Huff,
J. Jochum,
M. Kiefer,
C. Kister,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
J. Loebell,
A. Münster,
F. Petricca,
W. Potzel,
F. Pröbst,
F. Reindl,
S. Roth
, et al. (20 additional authors not shown)
Abstract:
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module efficiently vetoes low energy backgrounds induced by $α$-decays on inner surfaces of the detector. With an exposure of \unit[29.35]{kg live days} collected in 2013 we set…
▽ More
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module efficiently vetoes low energy backgrounds induced by $α$-decays on inner surfaces of the detector. With an exposure of \unit[29.35]{kg live days} collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering which probes a new region of parameter space for WIMP masses below \unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A possible excess over background discussed for the previous CRESST-II phase 1 (from 2009 to 2011) is not confirmed.
△ Less
Submitted 22 January, 2015; v1 submitted 11 July, 2014;
originally announced July 2014.
-
Interpretation of Light-Quenching Factor Measurements
Authors:
I. Bavykina,
P. Christ,
P. Huff,
J. Ninkovic,
F. Proebst,
W. Seidel,
L. Stodolsky
Abstract:
We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a saturation phenomenon in which the light output is simply proportional to track length, independent of the ion and its energy. This observation is in accord with the high dE/dx limit of Birks' law. It suggest…
▽ More
We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a saturation phenomenon in which the light output is simply proportional to track length, independent of the ion and its energy. This observation is in accord with the high dE/dx limit of Birks' law. It suggests a simple model for the intrinsic resolution of light detectors for low energy ions, which we briefly discuss.
△ Less
Submitted 5 July, 2007;