-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
Design and Development of a Novel Soft and Inflatable Tactile Sensing Balloon for Early Diagnosis of Colorectal Cancer Polyps
Authors:
Ozdemir Can Kara,
Han Soul Kim,
Jiaqi Xue,
Tarunraj G. Mohanraj,
Yuki Hirata,
Naruhiko Ikoma,
Farshid Alambeigi
Abstract:
In this paper, with the goal of addressing the high early-detection miss rate of colorectal cancer (CRC) polyps during a colonoscopy procedure, we propose the design and fabrication of a unique inflatable vision-based tactile sensing balloon (VTSB). The proposed soft VTSB can readily be integrated with the existing colonoscopes and provide a radiation-free, safe, and high-resolution textural mappi…
▽ More
In this paper, with the goal of addressing the high early-detection miss rate of colorectal cancer (CRC) polyps during a colonoscopy procedure, we propose the design and fabrication of a unique inflatable vision-based tactile sensing balloon (VTSB). The proposed soft VTSB can readily be integrated with the existing colonoscopes and provide a radiation-free, safe, and high-resolution textural mapping and morphology characterization of CRC polyps. The performance of the proposed VTSB has been thoroughly characterized and evaluated on four different types of additively manufactured CRC polyp phantoms with three different stiffness levels. Additionally, we integrated the VTSB with a colonoscope and successfully performed a simulated colonoscopic procedure inside a tube with a few CRC polyp phantoms attached to its internal surface.
△ Less
Submitted 18 September, 2023;
originally announced September 2023.
-
Status and performance of the AMoRE-I experiment on neutrinoless double beta decay
Authors:
H. B. Kim,
D. H. Ha,
E. J. Jeon,
J. A. Jeon,
H. S. Jo,
C. S. Kang,
W. G. Kang,
H. S. Kim,
S. C. Kim,
S. G. Kim,
S. K. Kim,
S. R. Kim,
W. T. Kim,
Y. D. Kim,
Y. H. Kim,
D. H. Kwon,
E. S. Lee,
H. J. Lee,
H. S. Lee,
J. S. Lee,
M. H. Lee,
S. W. Lee,
Y. C. Lee,
D. S. Leonard,
H. S. Lim
, et al. (10 additional authors not shown)
Abstract:
AMoRE is an international project to search for the neutrinoless double beta decay of $^{100}$Mo using a detection technology consisting of magnetic microcalorimeters (MMCs) and molybdenum-based scintillating crystals. Data collection has begun for the current AMORE-I phase of the project, an upgrade from the previous pilot phase. AMoRE-I employs thirteen $^\mathrm{48depl.}$Ca$^{100}$MoO$_4$ cryst…
▽ More
AMoRE is an international project to search for the neutrinoless double beta decay of $^{100}$Mo using a detection technology consisting of magnetic microcalorimeters (MMCs) and molybdenum-based scintillating crystals. Data collection has begun for the current AMORE-I phase of the project, an upgrade from the previous pilot phase. AMoRE-I employs thirteen $^\mathrm{48depl.}$Ca$^{100}$MoO$_4$ crystals and five Li$_2$$^{100}$MoO$_4$ crystals for a total crystal mass of 6.2 kg. Each detector module contains a scintillating crystal with two MMC channels for heat and light detection. We report the present status of the experiment and the performance of the detector modules.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
Monte Carlo calculation of organ and effective dose rates from ground contaminated by Am 241: Results of an international intercomparison exercise
Authors:
J Eakins,
C Huet,
H Brkić,
K Capello,
L Desorgher,
L Epstein,
J G Hunt,
H S Kim,
D Krstic,
Y-K Lee,
M Manohari,
D Nikezic,
R H Shukrun,
D. Souza-Santos,
K. Tymińska
Abstract:
An intercomparison exercise is described that examines Monte Carlo modelling of anthropomorphic voxel phantoms in an idealized ground-contamination photon exposure scenario. Thirteen participants calculated and submitted organ and effective dose rates for comparison against a set of verified reference solutions. The effective dose rates are shown to agree with the reference value to within reasona…
▽ More
An intercomparison exercise is described that examines Monte Carlo modelling of anthropomorphic voxel phantoms in an idealized ground-contamination photon exposure scenario. Thirteen participants calculated and submitted organ and effective dose rates for comparison against a set of verified reference solutions. The effective dose rates are shown to agree with the reference value to within reasonable statistical uncertainties in five of the cases, though in only one of those was similar agreement also demonstrated in the evaluation of all requested organ dose rates. Orders-of-magnitude differences in doses are seen for some of the other participants, both internally within their own dataset and also relative to the reference solutions. Following limited feedback and suggestions from the organizer, up to two sets of revised solutions were resubmitted by some of the participants; these generally exhibited improved agreement, though not always. The overall observations and conclusions from this intercomparison exercise are summarized and discussed.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
Monte Carlo calculation of the organ equivalent dose and effective dose due to immersion in a 16N beta source in air using the ICRP Reference Phantoms
Authors:
Jose M. Gomez-Ros,
Montserrat Moraleda,
Pedro Arce,
Duc-Ky Bui,
Thi-My-Linh Dang,
Laurent Desorgher,
Han Sung Kim,
Dragana Krstic,
Michal Kuc,
Ngoc-Thiem Le,
Yi-Kang Lee,
Ngoc-Quynh Nguyen,
Dragoslav Nikezic,
Katarzyna Tyminska,
Tomas Vrba
Abstract:
This work summarises the results of a comparison organized by EURADOS focused on the usage of the ICRP Reference Computational Phantoms. This activity aimed to provide training for the implementation of voxel phantoms in Monte Carlo radiation transport codes and the calculation of the dose equivalent in organs and the effective dose. This particular case describes a scenario of immersion in a 16N…
▽ More
This work summarises the results of a comparison organized by EURADOS focused on the usage of the ICRP Reference Computational Phantoms. This activity aimed to provide training for the implementation of voxel phantoms in Monte Carlo radiation transport codes and the calculation of the dose equivalent in organs and the effective dose. This particular case describes a scenario of immersion in a 16N beta source distributed in the air of a room with concrete walls where the phantom is located. Seven participants took part in the comparison of results using GEANT4, TRIPOLI-4 and MCNP family codes, and there was detected a general problem when calculating the dose to skeletal tissue and the remainder tissue. After a process of feedback with the participants the errors were corrected and the final results reached an agreement of +/-5%.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
Alpha backgrounds in the AMoRE-Pilot experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
S. H. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. Gezhaev,
V. D. Grigoryeva,
V. Gurentsov,
D. H. Ha,
C. Ha,
E. J. Ha,
I. Hahn,
E. J. Jeon
, et al. (81 additional authors not shown)
Abstract:
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit…
▽ More
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.
△ Less
Submitted 5 December, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Deep neural network Grad-Shafranov solver constrained with measured magnetic signals
Authors:
Semin Joung,
Jaewook Kim,
Sehyun Kwak,
J. G. Bak,
S. G. Lee,
H. S. Han,
H. S. Kim,
Geunho Lee,
Daeho Kwon,
Y. -c. Ghim
Abstract:
A neural network solving Grad-Shafranov equation constrained with measured magnetic signals to reconstruct magnetic equilibria in real time is developed. Database created to optimize the neural network's free parameters contain off-line EFIT results as the output of the network from $1,118$ KSTAR experimental discharges of two different campaigns. Input data to the network constitute magnetic sign…
▽ More
A neural network solving Grad-Shafranov equation constrained with measured magnetic signals to reconstruct magnetic equilibria in real time is developed. Database created to optimize the neural network's free parameters contain off-line EFIT results as the output of the network from $1,118$ KSTAR experimental discharges of two different campaigns. Input data to the network constitute magnetic signals measured by a Rogowski coil (plasma current), magnetic pick-up coils (normal and tangential components of magnetic fields) and flux loops (poloidal magnetic fluxes). The developed neural networks fully reconstruct not only the poloidal flux function $ψ\left( R, Z\right)$ but also the toroidal current density function $j_φ\left( R, Z\right)$ with the off-line EFIT quality. To preserve robustness of the networks against a few missing input data, an imputation scheme is utilized to eliminate the required additional training sets with large number of possible combinations of the missing inputs.
△ Less
Submitted 7 November, 2019;
originally announced November 2019.
-
Experimental and Theoretical Realization of Zenneck Wave-based Non-Radiative, Non-Coupled Wireless Power Transmission
Authors:
Sai Kiran Oruganti,
Jagannath Malik,
Jongwon Lee,
Dipra Paul,
Woojin Park,
Bonyoung Lee,
Seoktae Seo,
Hak Sun Kim,
Franklin Bien,
Thomas Thundat
Abstract:
A decade ago, non-radiative wireless power transmission re-emerged as a promising alternative to deliver electrical power to devices where a physical wiring proved to be unfeasible. However, existing approaches are neither scalable nor efficient when multiple devices are involved, as they are restricted by factors like coupling and external environments. Zenneck waves are excited at interfaces, li…
▽ More
A decade ago, non-radiative wireless power transmission re-emerged as a promising alternative to deliver electrical power to devices where a physical wiring proved to be unfeasible. However, existing approaches are neither scalable nor efficient when multiple devices are involved, as they are restricted by factors like coupling and external environments. Zenneck waves are excited at interfaces, like surface plasmons and have the potential to deliver electrical power to devices placed on a conducting surface. Here, we demonstrate, efficient and long range delivery of electrical power by exciting nonradiative waves over metal surfaces to multiple loads. Our modeling and simulation using Maxwells equation with proper boundary conditions shows Zenneck type behavior for the excited waves and are in excellent agreement with experimental results. In conclusion, we physically realize a radically different power transfer system, based on a wave, whose existence has been fiercely debated for over a century.
△ Less
Submitted 21 January, 2019;
originally announced March 2019.
-
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
D. M. Chernyak,
J. S. Choe,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. D. Grigoryeva,
V. I. Gurentsov,
O. Gylova,
C. Ha,
D. H. Ha
, et al. (84 additional authors not shown)
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-de…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.
△ Less
Submitted 7 May, 2019; v1 submitted 22 March, 2019;
originally announced March 2019.
-
Top-down fabrication of high-uniformity nanodiamonds by self-assembled block copolymer masks
Authors:
Jiabao Zheng,
Benjamin Lienhard,
Gregory Doerk,
Mircea Cotlet,
Eric Bersin,
Harrison Sejoon Kim,
Young-Chul Byun,
Chang-Yong Nam,
Jiyoung Kim,
Charles T. Black,
Dirk Englund
Abstract:
Nanodiamonds hosting colour centres are a promising material platform for various quantum technologies. The fabrication of non-aggregated and uniformly-sized nanodiamonds with systematic integration of single quantum emitters has so far been lacking. Here, we present a top-down fabrication method to produce 30.0$\pm$5.4 nm uniformly-sized single-crystal nanodiamonds by block copolymer self-assembl…
▽ More
Nanodiamonds hosting colour centres are a promising material platform for various quantum technologies. The fabrication of non-aggregated and uniformly-sized nanodiamonds with systematic integration of single quantum emitters has so far been lacking. Here, we present a top-down fabrication method to produce 30.0$\pm$5.4 nm uniformly-sized single-crystal nanodiamonds by block copolymer self-assembled nanomask patterning together with directional and isotropic reactive ion etching. We show detected emission from bright single nitrogen vacancy centres hosted in the fabricated nanodiamonds. The lithographically precise patterning of large areas of diamond by self-assembled masks and their release into uniformly sized nanodiamonds open up new possibilities for quantum information processing and sensing.
△ Less
Submitted 21 December, 2018;
originally announced December 2018.
-
Bayesian with Gaussian process based missing input imputation scheme for reconstructing magnetic equilibria in real time
Authors:
Semin Joung,
Jaewook Kim,
Sehyun Kwak,
Kyeo-reh Park,
S. H. Hahn,
H. S. Han,
H. S. Kim,
J. G. Bak,
S. G. Lee,
Y. -c. Ghim
Abstract:
A Bayesian with GP(Gaussian Process)-based numerical method to impute a few missing magnetic signals caused by impaired magnetic probes during tokamak operations is developed such that the real-time reconstruction of magnetic equilibria, whose performance strongly depends on the measured magnetic signals and their intactness, are affected minimally. Likelihood of the Bayesian model constructed wit…
▽ More
A Bayesian with GP(Gaussian Process)-based numerical method to impute a few missing magnetic signals caused by impaired magnetic probes during tokamak operations is developed such that the real-time reconstruction of magnetic equilibria, whose performance strongly depends on the measured magnetic signals and their intactness, are affected minimally. Likelihood of the Bayesian model constructed with the Maxwell's equations, specifically Gauss's law of magnetism and Ampère's law, results in infinite number of solutions if two or more magnetic signals are missing. This undesirable characteristic of the Bayesian model is remediated by coupling the model with the Gaussian process. Our proposed numerical method infers the missing magnetic signals correctly in less than $1$\:msec suitable for real-time reconstruction of magnetic equilibria during tokamak operations. The method can also be used for a neural network that reconstructs magnetic equilibria trained with a complete set of magnetic signals. Without our proposed imputation method, such a neural network would become useless if missing signals are not tolerable by the network.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
Stretching-induced conductance variations as fingerprints of contact configurations in single-molecule junctions
Authors:
Yong-Hoon Kim,
Hu Sung Kim,
Juho Lee,
Makusu Tsutsui,
Tomoji Kawai
Abstract:
Molecule-electrode contact atomic structures are a critical factor that characterizes molecular devices, but their precise understanding and control still remain elusive. Based on combined first-principles calculations and single-molecule break junction experiments, we herein establish that the conductance of alkanedithiolate junctions can both increase and decrease with mechanical stretching and…
▽ More
Molecule-electrode contact atomic structures are a critical factor that characterizes molecular devices, but their precise understanding and control still remain elusive. Based on combined first-principles calculations and single-molecule break junction experiments, we herein establish that the conductance of alkanedithiolate junctions can both increase and decrease with mechanical stretching and the specific trend is determined by the S-Au linkage coordination number (CN) or the molecule-electrode contact atomic structure. Specifically, we find that the mechanical pulling results in the conductance increase for the junctions based on S-Au CN two and CN three contacts, while the conductance is minimally affected by stretching for junctions with the CN one contact and decreases upon the formation of Au monoatomic chains. Detailed analysis unravels the mechanisms involving the competition between the stretching-induced upshift of the highest occupied molecular orbital-related states toward the Fermi level of electrodes and the deterioration of molecule-electrode electronic couplings in different contact CN cases. Moreover, we experimentally find a higher chance to observe the conductance enhancement mode under a faster elongation speed, which is explained by ab initio molecular dynamics simulations that reveal an important role of thermal fluctuations in aiding deformations of contacts into low-coordination configurations that include monoatomic Au chains. Pointing out the insufficiency in previous notions of associating peak values in conductance histograms with specific contact atomic structures, this work resolves the controversy on the origins of ubiquitous multiple conductance peaks in S-Au-based single-molecule junctions.
△ Less
Submitted 24 May, 2017;
originally announced May 2017.
-
Sterile neutrino search at NEOS Experiment
Authors:
Y. J. Ko,
B. R. Kim,
J. Y. Kim,
B. Y. Han,
C. H. Jang,
E. J. Jeon,
K. K. Joo,
H. J. Kim,
H. S. Kim,
Y. D. Kim,
Jaison Lee,
J. Y. Lee,
M. H. Lee,
Y. M. Oh,
H. K. Park,
H. S. Park,
K. S. Park,
K. M. Seo,
Kim Siyeon,
G. M. Sun
Abstract:
An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of abou…
▽ More
An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of about 22. The shape of the antineutrino energy spectrum obtained from eight-month data-taking period is compared with a hypothesis of oscillations due to active-sterile antineutrino mixing. It is found to be consistent with no oscillation. An excess around 5 MeV prompt energy range is observed as seen in existing longer baseline experiments. The parameter space of $\sin^{2}2θ_{14}$ down below 0.1 for $Δm^{2}_{41}$ ranging from 0.2 eV$^{2}$ to 2.3 eV$^{2}$ and the optimum point for the previously reported reactor antineutrino anomaly are excluded with a confidence level higher than 90%.
△ Less
Submitted 21 March, 2017; v1 submitted 17 October, 2016;
originally announced October 2016.
-
Measurement of Fast Neutron Rate for NEOS Experiment
Authors:
Y. J. Ko,
J. Y. Kim,
B. Y. Han,
C. H. Jang,
E. J. Jeon,
K. K. Joo,
B. R. Kim,
H. J. Kim,
H. S. Kim,
Y. D. Kim,
Jaison Lee,
J. Y. Lee,
M. H. Lee,
Y. M. Oh,
H. K. Park,
H. S. Park,
K. S. Park,
K. M. Seo,
Kim Siyeon,
G. M. Sun
Abstract:
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day fo…
▽ More
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day for both periods. The fast neutron rate is also measured at an overground site with a negligible overburden and is found to be ~100 times higher than that at the NEOS experiment site.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
Spectral Measurement of the Electron Antineutrino Oscillation Amplitude and Frequency using 500 Live Days of RENO Data
Authors:
S. H. Seo,
W. Q. Choi,
H. Seo,
J. H. Choi,
Y. Choi,
H. I. Jang,
J. S. Jang,
K. K. Joo,
B. R. Kim,
H. S. Kim,
J. Y. Kim,
S. B. Kim,
S. Y. Kim,
W. Kim,
E. Kwon,
D. H. Lee,
Y. C. Lee,
I. T. Lim,
M. Y. Pac,
I. G. Park,
J. S. Park,
R. G. Park,
Y. G. Seon,
C. D. Shin,
J. H. Yang
, et al. (3 additional authors not shown)
Abstract:
The Reactor Experiment for Neutrino Oscillation (RENO) has been taking electron antineutrino ($\overlineν_{e}$) data from the reactors in Yonggwang, Korea, using two identical detectors since August 2011. Using roughly 500 live days of data through January 2013 we observe 290,775 (31,514) reactor $\overlineν_{e}$ candidate events with 2.8 (4.9)% background in the near (far) detector. The observed…
▽ More
The Reactor Experiment for Neutrino Oscillation (RENO) has been taking electron antineutrino ($\overlineν_{e}$) data from the reactors in Yonggwang, Korea, using two identical detectors since August 2011. Using roughly 500 live days of data through January 2013 we observe 290,775 (31,514) reactor $\overlineν_{e}$ candidate events with 2.8 (4.9)% background in the near (far) detector. The observed visible positron spectra from the reactor $\overlineν_{e}$ events in both detectors show discrepancy around 5 MeV with regard to the prediction from the current reactor $\overlineν_{e}$ model. Based on a far-to-near ratio measurement using the spectral and rate information we have obtained $\sin^2 2 θ_{13} = 0.082 \pm 0.009({\rm stat.}) \pm 0.006({\rm syst.})$ and $|Δm_{ee}^2| =[2.62_{-0.23}^{+0.21}({\rm stat.})_{-0.13}^{+0.12}({\rm syst.})]\times 10^{-3}$eV$^2$.
△ Less
Submitted 16 May, 2018; v1 submitted 14 October, 2016;
originally announced October 2016.
-
In-Situ Measurement of Relative Attenuation Length of Gadolinium-Loaded Liquid Scintillator Using Source Data at RENO Experiment
Authors:
H. S. Kim,
S. Y. Kim,
J. H. Choi,
W. Q. Choi,
Y. Choi,
H. I. Jang,
J. S. Jang,
K. K. Joo,
B. R. Kim,
J. Y. Kim,
S. B. Kim,
W. Kim,
E. Kwon,
D. H. Lee,
I. T. Lim,
M. Y. Pac,
I. G. Park,
J. S. Park,
R. G. Park,
H. Seo,
S. H. Seo,
Y. G. Seon,
C. D. Shin,
I. S. Yeo,
I. Yu
Abstract:
We present in situ measurements of the relative attenuation length of the gadolinium loaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by 50% in about four years since the commissioning of the detectors.
We present in situ measurements of the relative attenuation length of the gadolinium loaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by 50% in about four years since the commissioning of the detectors.
△ Less
Submitted 22 May, 2023; v1 submitted 29 September, 2016;
originally announced September 2016.
-
Validation of cross sections for Monte Carlo simulation of the photoelectric effect
Authors:
Min Cheol Han,
Han Sung Kim,
Maria Grazia Pia,
Tullio Basaglia,
Matej Batic,
Gabriela Hoff,
Chan Hyeong Kim,
Paolo Saracco
Abstract:
Several total and partial photoionization cross section calculations, based on both theoretical and empirical approaches, are quantitatively evaluated with statistical analyses using a large collection of experimental data retrieved from the literature to identify the state of the art for modeling the photoelectric effect in Monte Carlo particle transport. Some of the examined cross section models…
▽ More
Several total and partial photoionization cross section calculations, based on both theoretical and empirical approaches, are quantitatively evaluated with statistical analyses using a large collection of experimental data retrieved from the literature to identify the state of the art for modeling the photoelectric effect in Monte Carlo particle transport. Some of the examined cross section models are available in general purpose Monte Carlo systems, while others have been implemented and subjected to validation tests for the first time to estimate whether they could improve the accuracy of particle transport codes. The validation process identifies Scofield's 1973 non-relativistic calculations, tabulated in the Evaluated Photon Data Library(EPDL), as the one best reproducing experimental measurements of total cross sections. Specialized total cross section models, some of which derive from more recent calculations, do not provide significant improvements. Scofield's non-relativistic calculations are not surpassed regarding the compatibility with experiment of K and L shell photoionization cross sections either, although in a few test cases Ebel's parameterization produces more accurate results close to absorption edges. Modifications to Biggs and Lighthill's parameterization implemented in Geant4 significantly reduce the accuracy of total cross sections at low energies with respect to its original formulation. The scarcity of suitable experimental data hinders a similar extensive analysis for the simulation of the photoelectron angular distribution, which is limited to a qualitative appraisal.
△ Less
Submitted 25 January, 2016;
originally announced January 2016.
-
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
W. Ahmed,
W. Ahmed,
P. Altieri,
R. Aly,
C. Asawatangtrakuldee,
A. Ashfaq,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
P. Barria,
L. Benussi,
V. Bhopatkar,
S. Bianco,
J. Bos,
O. Bouhali,
S. Braibant,
S. Buontempo
, et al. (113 additional authors not shown)
Abstract:
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi…
▽ More
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.
△ Less
Submitted 8 December, 2014; v1 submitted 30 November, 2014;
originally announced December 2014.
-
Geant4 and beyond: recent progress in precision physics modeling
Authors:
Matej Batic,
Marcia Begalli,
Min Cheol Han,
Steffen Hauf,
Gabriela Hoff,
Chan Hyeong Kim,
Han Sung Kim,
Sung Hun Kim,
Markus Kuster,
Maria Grazia Pia,
Paolo Saracco,
Georg Weidenspointner
Abstract:
This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation…
▽ More
This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented.
△ Less
Submitted 22 July, 2014;
originally announced July 2014.
-
Physics Methods for the Simulation of Photoionisation
Authors:
Tullio Basaglia,
Matej Batic,
Min Cheol Han,
Gabriela Hoff,
Chan Hyeong Kim,
Han Sung Kim,
Maria Grazia Pia,
Paolo Saracco
Abstract:
Several physics methods for the simulation of the photoelectric effect are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. They include theoretical and empirical calculations of total and partial cross sections, and calculations of the photoelectron angular distribution. Some of these models are currently implemented in general purpos…
▽ More
Several physics methods for the simulation of the photoelectric effect are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. They include theoretical and empirical calculations of total and partial cross sections, and calculations of the photoelectron angular distribution. Some of these models are currently implemented in general purpose Monte Carlo systems; some have been implemented and evaluated for possible use in Monte Carlo particle transport for the first time in this study.
△ Less
Submitted 20 November, 2013;
originally announced November 2013.
-
Slow Control Systems of the Reactor Experiment for Neutrino Oscillation
Authors:
J. H. Choi,
H. I. Jang,
W. Q. Choi,
Y. Choi,
J. S. Jang,
E. J. Jeon,
K. K. Joo,
B. R. Kim,
H. S. Kim,
J. Y. Kim,
S. B. Kim,
S. Y. Kim,
W. Kim,
Y. D. Kim,
Y. J. Ko,
J. K. Lee,
I. T. Lim,
M. Y. Pac,
I. G. Park,
J. S. Park,
R. G. Park,
H. K. Seo,
C. D. Shin,
K. Siyeon,
I. S. Yeo
, et al. (1 additional authors not shown)
Abstract:
The RENO experiment has been in operation since August 2011 to measure reactor antineutrino disappearance using identical near and far detectors. For accurate measurements of neutrino mixing parameters and efficient data taking, it is crucial to monitor and control the detector in real time. Environmental conditions also need to be monitored for stable operation of detectors as well as for safety…
▽ More
The RENO experiment has been in operation since August 2011 to measure reactor antineutrino disappearance using identical near and far detectors. For accurate measurements of neutrino mixing parameters and efficient data taking, it is crucial to monitor and control the detector in real time. Environmental conditions also need to be monitored for stable operation of detectors as well as for safety reasons. In this article, we report the design, hardware, operation, and performance of the slow control system.
△ Less
Submitted 9 December, 2015; v1 submitted 2 July, 2013;
originally announced July 2013.
-
Time and Amplitude of Afterpulse Measured with a Large Size Photomultiplier Tube
Authors:
K. J. Ma,
W. G. Kang,
J. K. Ahn,
S. Choi,
Y. Choi,
M. J. Hwang,
J. S. Jang,
E. J. Jeon,
K. K. Joo,
H. S. Kim,
J. Y. Kim,
S. B. Kim,
S. H. Kim,
W. Kim,
Y. D. Kim,
J. Lee,
I. T. Lim,
Y. D. OH,
M. Y. Pac,
C. W. Park,
I. G. Park,
K. S. Park,
S. S. Stepanyan,
I. Yu
Abstract:
We have studied the afterpulse of a hemispherical photomultiplier tube for an upcoming reactor neutrino experiment. The timing, the amplitude, and the rate of the afterpulse for a 10 inch photomultiplier tube were measured with a 400 MHz FADC up to 16 \ms time window after the initial signal generated by an LED light pulse. The time and amplitude correlation of the afterpulse shows several disti…
▽ More
We have studied the afterpulse of a hemispherical photomultiplier tube for an upcoming reactor neutrino experiment. The timing, the amplitude, and the rate of the afterpulse for a 10 inch photomultiplier tube were measured with a 400 MHz FADC up to 16 \ms time window after the initial signal generated by an LED light pulse. The time and amplitude correlation of the afterpulse shows several distinctive groups. We describe the dependencies of the afterpulse on the applied high voltage and the amplitude of the main light pulse. The present data could shed light upon the general mechanism of the afterpulse.
△ Less
Submitted 29 November, 2009;
originally announced November 2009.
-
On the origin of the optical nonlinearity of a gallium-silica interface
Authors:
P. Petropoulos,
H. S. Kim,
D. J. Richardson,
V. A. Fedotov,
N. I. Zheludev
Abstract:
Simultaneous measurements of the intensity and phase of a probe wave reflected from an interface between silica and elemental alpha-gallium reveal its very strong optical nonlinearity, affecting both these parameters of the reflected wave. The data corroborate with a non-thermal mechanism of optical response which assumes appearance of a homogeneous highly metallic layer, only a few nanometer th…
▽ More
Simultaneous measurements of the intensity and phase of a probe wave reflected from an interface between silica and elemental alpha-gallium reveal its very strong optical nonlinearity, affecting both these parameters of the reflected wave. The data corroborate with a non-thermal mechanism of optical response which assumes appearance of a homogeneous highly metallic layer, only a few nanometer thick, between the silica and bulk alpha-gallium.
△ Less
Submitted 11 January, 2001;
originally announced January 2001.