-
25-Fold Resolution Enhancement of X-ray Microscopy Using Multipixel Ghost Imaging
Authors:
O. Sefi,
A. Ben Yehuda,
Y. Klein,
S. Bloch,
H. Schwartz,
E. Cohen,
S. Shwartz
Abstract:
Hard x-ray imaging is indispensable across diverse fields owing to its high penetrability. However, the resolution of traditional x-ray imaging modalities, such as computed tomography (CT) systems, is constrained by factors including beam properties, the absence of optical components, and detection resolution. As a result, typical resolution in commercial imaging systems is limited to a few hundre…
▽ More
Hard x-ray imaging is indispensable across diverse fields owing to its high penetrability. However, the resolution of traditional x-ray imaging modalities, such as computed tomography (CT) systems, is constrained by factors including beam properties, the absence of optical components, and detection resolution. As a result, typical resolution in commercial imaging systems is limited to a few hundred microns. This study advances high-photon-energy imaging by extending the concept of computational ghost imaging to multipixel ghost imaging with x-rays. We demonstrate a remarkable enhancement in resolution from 500 microns to approximately 20 microns for an image spanning 0.9 by 1 cm^2, comprised of 400,000 pixels and involving only 1000 realizations. Furthermore, we present a high-resolution CT reconstruction using our method, revealing enhanced visibility and resolution. Our achievement is facilitated by an innovative x-ray lithography technique and the computed tiling of images captured by each detector pixel. Importantly, this method can be scaled up for larger images without sacrificing the short measurement time, thereby opening intriguing possibilities for noninvasive high-resolution imaging of small features that are invisible with the present modalities.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
-
FeynGame-2.1 -- Feynman diagrams made easy
Authors:
Robert Harlander,
Sven Yannick Klein,
Magnus Schaaf
Abstract:
FeynGame is an open-source software tool to draw Feynman diagrams, but also to get acquainted with their structure. This article reports on a number of new features which have been added to FeynGame since its first release. These include full support of LaTeX for the line and vertex labels, the possibility to automatically include momentum arrows, new graphical elements, and new pedagogical featur…
▽ More
FeynGame is an open-source software tool to draw Feynman diagrams, but also to get acquainted with their structure. This article reports on a number of new features which have been added to FeynGame since its first release. These include full support of LaTeX for the line and vertex labels, the possibility to automatically include momentum arrows, new graphical elements, and new pedagogical features. FeynGame is freely available as jar or MacOS app file from https://web.physik.rwth-aachen.de/user/harlander/software/feyngame, and as source code from https://gitlab.com/feyngame/FeynGame.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Monte Carlo Simulations for Ghost Imaging Based on Scattered Photons
Authors:
R. H. Shukrun,
Y. Klein.,
O. Sefi.,
Y. Fried.,
L. Epstein.,
S. Shwartz
Abstract:
X-ray based imaging modalities are widely used in research, industry, and in the medical field. Consequently, there is a strong motivation to improve their performances with respect to resolution, dose, and contrast. Ghost imaging (GI) is an imaging technique in which the images are reconstructed from measurements with a single-pixel detector using correlation between the detected intensities and…
▽ More
X-ray based imaging modalities are widely used in research, industry, and in the medical field. Consequently, there is a strong motivation to improve their performances with respect to resolution, dose, and contrast. Ghost imaging (GI) is an imaging technique in which the images are reconstructed from measurements with a single-pixel detector using correlation between the detected intensities and the intensity structures of the input beam. The method that has been recently extended to X-rays provides intriguing possibilities to overcome several fundamental challenges of X-ray imaging. However, understanding the potential of the method and designing X-ray GI systems pose challenges since in addition to geometric optic effects, radiation-matter interactions must be considered. Such considerations are fundamentally more complex than those at longer wavelengths as relativistic effects such as Compton scattering become significant. In this work we present a new method for designing and implementing GI systems using the particle transport code FLUKA, that rely on Monte Carlo (MC) sampling. This new approach enables comprehensive consideration of the radiation-matter interactions, facilitating successful planning of complex GI systems. As an example of an advanced imaging system, we simulate a high-resolution scattered photons GI technique.
△ Less
Submitted 29 June, 2023;
originally announced June 2023.
-
Synchrotron-based X-ray Fluorescence Ghost Imaging
Authors:
Mathieu Manni,
Adi Ben-Yehuda,
Yishay Klein,
Bratislav Lukic,
Andrew Kingston,
Alexander Rack,
Sharon Shwartz,
Nicola Viganò
Abstract:
X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the focusing constraints of the probing beam. Here, we demonstrate the realization of synchrotron-based XRF-GI: We present both an adapted experimental setup and its corre…
▽ More
X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the focusing constraints of the probing beam. Here, we demonstrate the realization of synchrotron-based XRF-GI: We present both an adapted experimental setup and its corresponding required computational technique to process the data. This extends the above-mentioned potential advantages of GI to synchrotron XRF imaging. In addition, it enables new strategies to improve resilience against drifts at all scales, and the study of previously inaccessible samples, such as liquids.
△ Less
Submitted 18 August, 2023; v1 submitted 28 June, 2023;
originally announced June 2023.
-
High-resolution computed tomography with scattered x-ray radiation and a single pixel detector
Authors:
A. Ben Yehuda,
O. Sefi,
Y. Klein,
R. H Shukrun,
H. Schwartz,
E. Cohen,
S. Shwartz
Abstract:
X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial x-ray modalities, an image is formed by measuring the x-rays that pass through the object of interest. However, despite the potential of scattered radiation to provide additional information about the object, it is often disregarded due to its inherent ten…
▽ More
X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial x-ray modalities, an image is formed by measuring the x-rays that pass through the object of interest. However, despite the potential of scattered radiation to provide additional information about the object, it is often disregarded due to its inherent tendency to cause blurring. Consequently, conventional imaging modalities do not measure or utilize these valuable data. In contrast, we propose and experimentally demonstrate a high-resolution technique for x-ray computed tomography (CT) that measures scattered radiation by exploiting computational ghost imaging (CGI). We show that our method can provide sub-200 μm resolution, exceeding the capabilities of most existing x-ray imaging modalities. Our research reveals a promising technique for incorporating scattered radiation data in CT scans to improve image resolution and minimize radiation exposure for patients. The findings of our study suggest that our technique could represent a significant advancement in the fields of medical and industrial imaging, with the potential to enhance the accuracy and safety of diagnostic imaging procedures.
△ Less
Submitted 21 May, 2023;
originally announced May 2023.
-
FEL stochastic spectroscopy revealing silicon bond softening dynamics
Authors:
Dario De Angelis,
Emiliano Principi,
Filippo Bencivenga,
Daniele Fausti,
Laura Foglia,
Yishay Klein,
Michele Manfredda,
Riccardo Mincigrucci,
Angela Montanaro,
Emanuele Pedersoli,
Jacopo Stefano Pelli Cresi,
Giovanni Perosa,
Kevin C. Prince,
Elia Razzoli,
Sharon Shwartz,
Alberto Simoncig,
Simone Spampinati,
Cristian Svetina,
Jakub Szlachetko,
Alok Tripathi,
Ivan A. Vartanyants,
Marco Zangrando,
Flavio Capotondi
Abstract:
Time-resolved X-ray Emission/Absorption Spectroscopy (Tr-XES/XAS) is an informative experimental tool sensitive to electronic dynamics in materials, widely exploited in diverse research fields. Typically, Tr-XES/XAS requires X-ray pulses with both a narrow bandwidth and sub-picosecond pulse duration, a combination that in principle finds its optimum with Fourier transform-limited pulses. In this w…
▽ More
Time-resolved X-ray Emission/Absorption Spectroscopy (Tr-XES/XAS) is an informative experimental tool sensitive to electronic dynamics in materials, widely exploited in diverse research fields. Typically, Tr-XES/XAS requires X-ray pulses with both a narrow bandwidth and sub-picosecond pulse duration, a combination that in principle finds its optimum with Fourier transform-limited pulses. In this work, we explore an alternative xperimental approach, capable of simultaneously retrieving information about unoccupied (XAS) and occupied (XES) states from the stochastic fluctuations of broadband extreme ultraviolet pulses of a free-electron laser. We used this method, in combination with singular value decomposition and Tikhonov regularization procedures, to determine the XAS/XES response from a crystalline silicon sample at the L2,3-edge, with an energy resolution of a few tens of meV. Finally, we combined this spectroscopic method with a pump-probe approach to measure structural and electronic dynamics of a silicon membrane. Tr-XAS/XES data obtained after photoexcitation with an optical laser pulse at 390 nm allowed us to observe perturbations of the band structure, which are compatible with the formation of the predicted precursor state of a non-thermal solid-liquid phase transition associated with a bond softening phenomenon.
△ Less
Submitted 9 May, 2023;
originally announced May 2023.
-
High energy-resolution transient ghost absorption spectroscopy
Authors:
Alok Kumar Tripathi,
Yishai Klein,
Edward Strizhevsky,
Flavio Capotondi,
Dario De Angelis,
Luca Giannessi,
Matteo Pancaldi,
Emanuele Pedersoli,
Kevin C. Prince,
Or Sefi,
Young Yong Kim,
Ivan A. Vartanyants,
Sharon Shwartz
Abstract:
We demonstrate the measurement of ultrafast dynamics using ghost spectroscopy and a pump-probe approach with an optical pump and a short-wavelength radiation probe. The ghost spectroscopy approach is used to overcome the challenge of the strong intensity and spectrum fluctuations at free-electron lasers and to provide high -spectral resolution, which enables the measurement of small energy shifts…
▽ More
We demonstrate the measurement of ultrafast dynamics using ghost spectroscopy and a pump-probe approach with an optical pump and a short-wavelength radiation probe. The ghost spectroscopy approach is used to overcome the challenge of the strong intensity and spectrum fluctuations at free-electron lasers and to provide high -spectral resolution, which enables the measurement of small energy shifts in the absorption spectrum. We exploit the high resolution to explore the dynamics of the charge carrier excitations and relaxations and their impact on the photoinduced structural changes in silicon by measuring the variation of the absorption spectrum of a Si(100) membrane near the silicon L2,3 edge and the accompanying edge shifts in response to the optical illumination.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
High-resolution absorption measurements with free-electron lasers using ghost spectroscopy
Authors:
Yishai Klein,
Edward Strizhevsky,
Flavio Capotondi,
Dario De Angelis,
Luca Giannessi,
Matteo Pancaldi,
Emanuele Pedersoli,
Giuseppe Penco,
Kevin C. Prince,
Or Sefi,
Young Yong Kim,
Ivan A. Vartanyants,
Sharon Shwartz
Abstract:
We demonstrate a simple and robust high-resolution ghost spectroscopy approach for x-ray and extreme ultraviolet absorption spectroscopy at free-electron laser sources. Our approach requires an on-line spectrometer before the sample and a downstream bucket detector. We use this method to measure the absorption spectrum of silicon, silicon carbide and silicon nitride membranes in the vicinity of th…
▽ More
We demonstrate a simple and robust high-resolution ghost spectroscopy approach for x-ray and extreme ultraviolet absorption spectroscopy at free-electron laser sources. Our approach requires an on-line spectrometer before the sample and a downstream bucket detector. We use this method to measure the absorption spectrum of silicon, silicon carbide and silicon nitride membranes in the vicinity of the silicon L2,3-edge. We show that ghost spectroscopy allows the high-resolution reconstruction of the sample spectral response using a coarse energy scan with self-amplified spontaneous emission radiation. For the conditions of our experiment the energy resolution of the ghost-spectroscopy reconstruction is higher than the energy resolution reached by scanning the energy range by narrow spectral bandwidth radiation produced by the seeded free-electron laser. When we set the photon energy resolution of the ghost spectroscopy to be equal to the resolution of the measurement with the seeded radiation, the measurement time with the ghost spectroscopy method is shorter than scanning the photon energy with seeded radiation. The exact conditions for which ghost spectroscopy can provide higher resolution at shorter times than measurement with narrow band scans depend on the details of the measurements and on the properties of the samples and should be addressed in future studies.
△ Less
Submitted 1 March, 2022;
originally announced March 2022.
-
Influence of the distribution of the properties of permanent magnets on the field homogeneity of magnet assemblies for mobile NMR
Authors:
Yannick Klein,
Leon Abelmann,
Han Gardeniers
Abstract:
We optimised the magnetic field homogeneity of two canonical designs for mobile microfluidic NMR applications: two parallel magnets with an air gap and a modified Halbach array. Along with the influence of the sample length, general design guidelines will be presented. For a fair comparison the sensitive length of the sample has been chosen to be the same as the gap size between the magnets to ens…
▽ More
We optimised the magnetic field homogeneity of two canonical designs for mobile microfluidic NMR applications: two parallel magnets with an air gap and a modified Halbach array. Along with the influence of the sample length, general design guidelines will be presented. For a fair comparison the sensitive length of the sample has been chosen to be the same as the gap size between the magnets to ensure enough space for the transmitting and receiving unit, as well as basic electric shimming components. Keeping the compactness of the final device in mind, a box with an edge length 5 times the gap size has been defined, in which the complete magnet configuration should fit. With the chosen boundary conditions, the simple parallel cuboid configuration reaches the best homogeneity without active shimming (0.5$\mathrm{B_{s}}$, 41 ppm), while the Pseudo-Halbach configuration has the highest field strength (0.9$\mathrm{B_{s}}$, 994 ppm), assuming perfect magnets. However, permanent magnet configurations suffer from imperfections, such as magnetisation, fabrication and positioning errors, which results in worse magnetic field homogeneities than expected from simulations using a fixed optimised parameter set. We present a sensitivity analysis for a magnetic cube and the results of studies of the variations in the magnetisation and angle of magnetisation of magnets purchased from different suppliers, composed of different materials and coatings, and of different sizes. We performed a detailed Monte Carlo simulation on the effect of the measured distribution of magnetic properties on the mentioned configurations. The cuboid design shows a mean homogeneity of 430 ppm (std dev. 350 ppm), the Pseudo-Halbach has a mean homogeneity of 1086 ppm (std dev. 8 ppm).
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Chemical element mapping by x-ray ghost fluorescence
Authors:
Y. Klein,
O. Sefi,
H. Schwartz,
S. Shwartz
Abstract:
Chemical element mapping is an imaging tool that provides essential information on composite materials and it is crucial for a broad range of fields ranging from fundamental science to numerous applications. Methods that exploit x-ray fluorescence are very advantageous and are widely used, but require focusing of the input beam and raster scanning of the sample. Thus the methods are slow and exhib…
▽ More
Chemical element mapping is an imaging tool that provides essential information on composite materials and it is crucial for a broad range of fields ranging from fundamental science to numerous applications. Methods that exploit x-ray fluorescence are very advantageous and are widely used, but require focusing of the input beam and raster scanning of the sample. Thus the methods are slow and exhibit limited resolution due to focusing challenges. We demonstrate a new focusing free x-ray fluorescence method based ghost imaging that overcomes those limitations. We combine our procedure with compressed sensing to reduce the measurement time and the exposure to radiation by more than 80%. Since our method does not require focusing, it opens the possibility for improving the resolution and image quality of chemical element maps with tabletop x-ray sources and for extending the applicability of x-ray fluorescence detection to new fields such as medical imaging and homeland security applications
△ Less
Submitted 15 February, 2021;
originally announced February 2021.
-
Trajectory Deflection of Spinning Magnetic Microparticles, the Magnus Effect at the Microscale
Authors:
M. Solsona,
H. Keizer,
H. de Boer,
Y. P. Klein,
W. Olthuis,
L. Abelmann,
A. van den Berg
Abstract:
The deflection due to the Magnus force of magnetic particles with a diameter of 80 micrometer dropping through fluids and rotating in a magnetic field was measured. With Reynolds number for this experiment around 1, we found trajectory deflections of the order of 1 degree, in agreement within measurement error with theory. This method holds promise for the sorting and analysis of the distribution…
▽ More
The deflection due to the Magnus force of magnetic particles with a diameter of 80 micrometer dropping through fluids and rotating in a magnetic field was measured. With Reynolds number for this experiment around 1, we found trajectory deflections of the order of 1 degree, in agreement within measurement error with theory. This method holds promise for the sorting and analysis of the distribution in magnetic moment and particle diameter of suspensions of microparticles, such as applied in catalysis, or objects loaded with magnetic particles.
△ Less
Submitted 29 April, 2020;
originally announced April 2020.
-
High-speed x-ray imaging with single-pixel detector
Authors:
O. Sefi,
Y. Klein,
E. Strizhevsky,
I. P. Dolbnya,
S. Shwartz
Abstract:
We demonstrate experimentally the ability to use a single pixel detector for two-dimensional high-speed and high-resolution x-ray imaging. We image the rotation of a spinning chopper at 100-kHz at spatial resolution of about 15 microns by using the computational ghost imaging approach. The technique we develop can be used for the imaging of high-speed periodic dynamics or periodically stimulated e…
▽ More
We demonstrate experimentally the ability to use a single pixel detector for two-dimensional high-speed and high-resolution x-ray imaging. We image the rotation of a spinning chopper at 100-kHz at spatial resolution of about 15 microns by using the computational ghost imaging approach. The technique we develop can be used for the imaging of high-speed periodic dynamics or periodically stimulated effects with a large field of view and at low dose.
△ Less
Submitted 20 April, 2020;
originally announced April 2020.
-
FeynGame
Authors:
R. V. Harlander,
S. Y. Klein,
M. Lipp
Abstract:
A java-based graphical tool for drawing Feynman diagrams is presented. It differs from similar existing tools in various respects. For example, it is based on models, consisting of particles (lines) and (optionally) vertices, each of which can be given their individual properties (line style, color, arrows, label, etc.). The diagrams can be exported in any standard image format, or as PDF. Aside f…
▽ More
A java-based graphical tool for drawing Feynman diagrams is presented. It differs from similar existing tools in various respects. For example, it is based on models, consisting of particles (lines) and (optionally) vertices, each of which can be given their individual properties (line style, color, arrows, label, etc.). The diagrams can be exported in any standard image format, or as PDF. Aside from its plain graphical aspect, the goal of FeynGame is also educative, as it can check a Feynman diagrams validity. This provides the basis to play games with diagrams, for example. Here we describe on such game where a given set of initial and final states must be connected through a Feynman diagram within a given interaction model.
△ Less
Submitted 28 February, 2020;
originally announced March 2020.