Frequency and Amplitude Optimizations for Magnetic Particle Spectroscopy Applications
Authors:
Vinit Kumar Chugh,
Arturo di Girolamo,
Venkatramana D. Krishna,
Kai Wu,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
Nowadays, there is a growing interest in the field of magnetic particle spectroscopy (MPS)-based bioassays. MPS monitors the dynamic magnetic response of surface-functionalized magnetic nanoparticles (MNPs) upon excitation by an alternating magnetic field (AMF) to detect various target analytes. This technology has flourished in the past decade due to its low cost, low background magnetic noise in…
▽ More
Nowadays, there is a growing interest in the field of magnetic particle spectroscopy (MPS)-based bioassays. MPS monitors the dynamic magnetic response of surface-functionalized magnetic nanoparticles (MNPs) upon excitation by an alternating magnetic field (AMF) to detect various target analytes. This technology has flourished in the past decade due to its low cost, low background magnetic noise interference from biomatrix, and fast response time. A large number of MPS variants have been reported by different groups around the world, with applications ranging from disease diagnosis to foodborne pathogen detection, and virus detection. However, there is an urgent need for guidance on how to optimize the sensitivity of MPS detection by choosing different types of MNPs, AMF modalities, and MPS assay strategies (i.e., volume- and surface-based assays). In this work, we systematically study the effect of AMF frequencies and amplitudes on the responses of single- and multi-core MNPs under two extreme conditions, namely, the bound and unbound states. Our results show that some modalities such as dual-frequency MPS utilizing multicore MNPs are more suitable for surface-based bioassay applications, whereas, single-frequency MPS systems using single- or multi-core MNPs are better suited for volumetric bioassay applications. Furthermore, the bioassay sensitivities for these modalities can be further improved by careful selection of AMF frequencies and amplitudes.
△ Less
Submitted 10 November, 2022;
originally announced November 2022.
-
5-Minute Magnetic Particle Spectroscopy (MPS)-based Bioassay: Towards Ultra-fast, Convenient, and Large-scale Disease Diagnosis
Authors:
Kai Wu,
Vinit Kumar Chugh,
Venkatramana D. Krishna,
Yongqiang Andrew Wang,
Timothy D. Gordon,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
In this work, we report a 5-minute magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface functionalized magnetic nanoparticles (MNPs) are incubated with target analytes at 37 °C with agitation for 3 minutes and the MPS reading is then taken at the 5th minute. We have proved the feasibility of 5-minute ultra-fast detection of SARS-CoV-2 spike protein with a detectio…
▽ More
In this work, we report a 5-minute magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface functionalized magnetic nanoparticles (MNPs) are incubated with target analytes at 37 °C with agitation for 3 minutes and the MPS reading is then taken at the 5th minute. We have proved the feasibility of 5-minute ultra-fast detection of SARS-CoV-2 spike protein with a detection limit below 5 nM (0.2 pmole). Our proposed 5-minute bioassay strategy may be applied to reduce assay time for other liquid phase, volumetric biosensors such as nuclear magnetic resonance (NMR), quantum dots (QD), fluorescent biosensors, etc.
△ Less
Submitted 25 September, 2022;
originally announced October 2022.
-
One-step, Wash-free, Nanoparticle Clustering-based Magnetic Particle Spectroscopy (MPS) Bioassay Method for Detection of SARS-CoV-2 Spike and Nucleocapsid Proteins in Liquid Phase
Authors:
Kai Wu,
Vinit Kumar Chugh,
Venkatramana D. Krishna,
Arturo di Girolamo,
Yongqiang Andrew Wang,
Renata Saha,
Shuang Liang,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround t…
▽ More
With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround time that may worsen the disease surveillance and pandemic control. In sight of this situation, a rapid, one-step, easy-to-use, and high accuracy diagnostic platform will be valuable for future epidemic control especially for regions with scarce medical resources. Herein, we report a magnetic particle spectroscopy (MPS) platform for detection of SARS-CoV-2 biomarkers: spike and nucleocapsid proteins.
△ Less
Submitted 1 August, 2021;
originally announced August 2021.
-
Magnetic Particle Spectroscopy (MPS) with One-stage Lock-in Implementation for Magnetic Bioassays with Improved Sensitivities
Authors:
Vinit Kumar Chugh,
Kai Wu,
Venkatramana D. Krishna,
Arturo di Girolamo,
Robert P. Bloom,
Yongqiang Andrew Wang,
Renata Saha,
Shuang Liang,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
In recent years, magnetic particle spectroscopy (MPS) has become a highly sensitive and versatile sensing technique for quantitative bioassays. It relies on the dynamic magnetic responses of magnetic nanoparticles (MNPs) for the detection of target analytes in liquid phase. There are many research studies reporting the application of MPS for detecting a variety of analytes including viruses, toxin…
▽ More
In recent years, magnetic particle spectroscopy (MPS) has become a highly sensitive and versatile sensing technique for quantitative bioassays. It relies on the dynamic magnetic responses of magnetic nanoparticles (MNPs) for the detection of target analytes in liquid phase. There are many research studies reporting the application of MPS for detecting a variety of analytes including viruses, toxins, and nucleic acids, etc. Herein, we report a modified version of MPS platform with the addition of a one-stage lock-in design to remove the feedthrough signals induced by external driving magnetic fields, thus capturing only MNP responses for improved system sensitivity. This one-stage lock-in MPS system is able to detect as low as 781 ng multi-core Nanomag50 iron oxide MNPs (micromod Partikeltechnologie GmbH) and 78 ng single-core SHB30 iron oxide MNPs (Ocean NanoTech). In addition, using a streptavidin-biotin binding system as a proof-of-concept, we show that these single-core SHB30 MNPs can be used for Brownian relaxation-based bioassays while the multi-core Nanomag50 cannot be used. The effects of MNP amount on the concentration dependent response profiles for detecting streptavidin was also investigated. Results show that by using lower concentration/amount of MNPs, concentration-response curves shift to lower concentration/amount of target analytes. This lower concentrationresponse indicates the possibility of improved bioassay sensitivities by using lower amounts of MNPs.
△ Less
Submitted 26 May, 2021;
originally announced May 2021.
-
Portable Magnetic Particle Spectrometer (MPS) for Future Rapid and Wash-free Bioassays
Authors:
Kai Wu,
Vinit Kumar Chugh,
Arturo di Girolamo,
Jinming Liu,
Renata Saha,
Diqing Su,
Venkatramana D. Krishna,
Abilash Nair,
Will Davies,
Andrew Yongqiang Wang,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
Nowadays, there is an increasing demand for more accessible routine diagnostics for patients with respect to high accuracy, ease of use, and low cost. However, the quantitative and high accuracy bioassays in large hospitals and laboratories usually require trained technicians and equipment that is both bulky and expensive. In addition, the multi-step bioassays and long turnaround time could severe…
▽ More
Nowadays, there is an increasing demand for more accessible routine diagnostics for patients with respect to high accuracy, ease of use, and low cost. However, the quantitative and high accuracy bioassays in large hospitals and laboratories usually require trained technicians and equipment that is both bulky and expensive. In addition, the multi-step bioassays and long turnaround time could severely affect the disease surveillance and control especially in pandemics such as influenza and COVID-19. In view of this, a portable, quantitative bioassay device will be valuable in regions with scarce medical resources and help relieve burden on local healthcare systems. Herein, we introduce the MagiCoil diagnostic device, an inexpensive, portable, quantitative and rapid bioassay platform based on magnetic particle spectrometer (MPS) technique. MPS detects the dynamic magnetic responses of magnetic nanoparticles (MNPs) and uses the harmonics from oscillating MNPs as metrics for sensitive and quantitative bioassays. This device does not require trained technicians to operate and employs a fully automatic, one-step, wash-free assay with user friendly smartphone interface. Using a streptavidin-biotin binding system as a model, we show that the detection limit of the current portable device for streptavidin is 64 nM (equal to 5.12 pmole). In addition, this MPS technique is very versatile and allows for the detection of different diseases just by changing the surface modifications on MNPs.
△ Less
Submitted 19 November, 2020;
originally announced November 2020.
-
Magnetic Immunoassays: A Review of Virus and Pathogen Detection Before and Amidst the Coronavirus Disease-19 (COVID-19)
Authors:
Kai Wu,
Renata Saha,
Diqing Su,
Venkatramana D. Krishna,
Jinming Liu,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), is a threat to the global healthcare system and economic security. As of July 2020, no specific drugs or vaccines are yet available for COVID-19, fast and accurate diagnosis for SARS-CoV-2 is essential in slowing down the spread of COVID-19 and for efficient implementation of c…
▽ More
The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), is a threat to the global healthcare system and economic security. As of July 2020, no specific drugs or vaccines are yet available for COVID-19, fast and accurate diagnosis for SARS-CoV-2 is essential in slowing down the spread of COVID-19 and for efficient implementation of control and containment strategies. Magnetic immunoassay is a novel and emerging topic representing the frontiers of current biosensing and magnetics areas. The past decade has seen rapid growth in applying magnetic tools for biological and biomedical applications. Recent advances in magnetic materials and nanotechnologies have transformed current diagnostic methods to nanoscale and pushed the detection limit to early stage disease diagnosis. Herein, this review covers the literatures of magnetic immunoassay platforms for virus and pathogen detections, before COVID-19. We reviewed the popular magnetic immunoassay platforms including magnetoresistance (MR) sensors, magnetic particle spectroscopy (MPS), and nuclear magnetic resonance (NMR). Magnetic Point-of-Care (POC) diagnostic kits are also reviewed aiming at developing plug-and-play diagnostics to manage the SARS-CoV-2 outbreak as well as preventing future epidemics. In addition, other platforms that use magnetic materials as auxiliary tools for enhanced pathogen and virus detections are also covered. The goal of this review is to inform the researchers of diagnostic and surveillance platforms for SARS-CoV-2 and their performances.
△ Less
Submitted 9 July, 2020;
originally announced July 2020.
-
Detection of Influenza A Virus Nucleoprotein Through the Self-Assembly of Nanoparticles in Magnetic Particle Spectroscopy-Based Bioassays: A Method for Rapid, Sensitive, and Wash-free Magnetic Immunoassays
Authors:
Kai Wu,
Jinming Liu,
Renata Saha,
Diqing Su,
Venkatramana D. Krishna,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
Magnetic nanoparticles (MNPs) with proper surface functionalization have been extensively applied as labels for magnetic immunoassays, carriers for controlled drug/gene delivery, tracers and contrasts for magnetic imaging, etc. Here, we introduce a new biosensing scheme based on magnetic particle spectroscopy (MPS) and the self-assembly of MNPs to quantitatively detect H1N1 nucleoprotein molecules…
▽ More
Magnetic nanoparticles (MNPs) with proper surface functionalization have been extensively applied as labels for magnetic immunoassays, carriers for controlled drug/gene delivery, tracers and contrasts for magnetic imaging, etc. Here, we introduce a new biosensing scheme based on magnetic particle spectroscopy (MPS) and the self-assembly of MNPs to quantitatively detect H1N1 nucleoprotein molecules. MPS monitors the harmonics of oscillating MNPs as a metric for the freedom of rotational motion, thus indicating the bound states of MNPs. These harmonics can be readily collected from nanogram quantities of iron oxide nanoparticles within 10 s. H1N1 nucleoprotein molecule hosts multiple different epitopes that forms binding sites for many IgG polyclonal antibodies. Anchoring IgG polyclonal antibodies onto MNPs triggers the cross-linking between MNPs and H1N1 nucleoprotein molecules, thereby forming MNP self-assemblies. Using MPS and the self-assembly of MNPs, we achieved the sensitivity of 44 nM (442 pmole) for detecting H1N1 nucleoprotein. In addition, the morphologies and the hydrodynamic sizes of the MNP self-assemblies are characterized to verify the MPS results. Different MNP self-assembly models such as classical cluster, open ring tetramer, chain model as well as multimers (from dimer to pentamer) are proposed in this paper. Herein, we claim the feasibility of using MPS and the self-assembly of MNPs as a new biosensing scheme for detecting ultralow concentrations of target biomolecules, which can be employed as rapid, sensitive, and wash-free magnetic immunoassays.
△ Less
Submitted 12 July, 2019;
originally announced July 2019.