-
Studies of Cherenkov Photon Production in PbF$_2$ Crystals using Proton Beams at Fermilab
Authors:
Thomas Anderson,
Alberto Belloni,
Grace Cummings,
Sarah Eno,
Nora Fischer,
Liang Guan,
Yuxiang Guo,
Robert Hirosky,
James Hirschauer,
Yihui Lai,
Daniel Levin,
Hui-Chi Lin,
Mekhala Paranjpe,
Jianming Qian,
Bing Zhou,
Junjie Zhu,
Ren-Yuan Zhu
Abstract:
Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precisi…
▽ More
Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. We focus on using PbF2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Loss of Axial Symmetry in Hypersonic Flows over Conical Shapes
Authors:
Irmak T. Karpuzcu,
Deborah A. Levin
Abstract:
The assumption of axial symmetry for hypersonic flows over conically shaped geometries is ubiquitous in both experiments and numerical simulations. Yet depending on the free stream conditions, many of these flows are unsteady and their transition from laminar to turbulent is a three-dimensional phenomena. Combining triple deck theory/linear stability analysis with the kinetic direct simulation Mon…
▽ More
The assumption of axial symmetry for hypersonic flows over conically shaped geometries is ubiquitous in both experiments and numerical simulations. Yet depending on the free stream conditions, many of these flows are unsteady and their transition from laminar to turbulent is a three-dimensional phenomena. Combining triple deck theory/linear stability analysis with the kinetic direct simulation Monte Carlo method we analyze the azimuthal eigenmodes of flows over single and double-cone configurations. For Mach 16 flows we find that the strongest amplification rate occurs for the non-axisymmetric azimuthal wavenumber of n = 1. This occurs in regions quite close to the tip of the cone due to the proximity of the conical shock to the viscous shear layer where non-axisymmetric modes are amplified through linear mechanisms. Comparison of triple deck linear stability predictions shows that in addition to the azimuthal wavenumber, both the temporal content and amplification rate of these non-axisymmetric disturbances agree well with the time accurate DSMC flowfield. In addition to the loss of axial symmetry observed at the conical shock, the effect of axial symmetry assumptions on the more complex shock-shock and shock-boundary layer interactions of a flow over a double cone are considered. The results for the separation region show that axisymmetric and three dimensional simulations differ in almost all of the main flow structures. Three dimensional flowfields result in a smaller separation bubble with weaker shocks and three dimensional effects were manifest in the variation in surface parameters in the azimuthal direction as well. Interestingly, the DSMC simulations show that the loss of axial symmetry in the separation region, begins near the cone tip.
△ Less
Submitted 9 July, 2024;
originally announced July 2024.
-
On linear stability of supersonic flow over a short compression corner at large ramp angles
Authors:
Irmak T. Karpuzcu,
Vassilis Theofilis,
Deborah A. Levin
Abstract:
Linear stability of supersonic flow over a short compression corner with ramp angles 30 and 42 is investigated using Direct Simulation Monte Carlo (DSMC) and Linear Stability Theory (LST) at Mach number 3, Reynolds number 11,200 and low Knudsen number, O(10$^{-4}$). The two-dimensional base flows feature nonzero velocity slip and temperature jump and were found to be steady and laminar at both ram…
▽ More
Linear stability of supersonic flow over a short compression corner with ramp angles 30 and 42 is investigated using Direct Simulation Monte Carlo (DSMC) and Linear Stability Theory (LST) at Mach number 3, Reynolds number 11,200 and low Knudsen number, O(10$^{-4}$). The two-dimensional base flows feature nonzero velocity slip and temperature jump and were found to be steady and laminar at both ramp angles. Modal analysis revealed a previously unknown traveling three-dimensional global mode, the amplitude functions of which peak at the leading-edge and separation shocks and extend within the shear layer of the large laminar separation bubble formed on the short compression corner. This mode is linearly unstable at the higher ramp angle and stable at the lower one, while the known stationary three-dimensional global mode which peaks at the laminar separation is also present in the spectrum, but is (strongly) damped at both ramp angles. Three-dimensional DSMC simulations have fully confirmed the LST results, underlined (again) the significance of modeling the shock contribution in linear stability analyses of high-speed flow, and predicted the nonlinear evolution of the flow up to the generation of lambda vortices on the ramp, for the first time in the context of kinetic theory simulations.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
An Open-Cell Environmental Transmission Electron Microscopy Technique for In Situ Characterization of Samples in Aqueous Liquid Solutions
Authors:
Barnaby D. A. Levin,
Diane Haiber,
Qianlang Liu,
Peter A. Crozier
Abstract:
The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically chal…
▽ More
The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.
△ Less
Submitted 18 August, 2023;
originally announced August 2023.
-
Kinetic Simulation of Ion Thruster Plume Neutralization in a Vacuum Chamber
Authors:
Keita Nishii,
Deborah Levin
Abstract:
The electrical environment of a ground vacuum testing chamber creates facility effects for gridded ion thrusters. For example, it is well known that the plume from the thruster generates current paths that are very different from what occurs in space, and the neutralization of this plume is also different. For reasons such as this, it is important to clarify how the experimental testing environmen…
▽ More
The electrical environment of a ground vacuum testing chamber creates facility effects for gridded ion thrusters. For example, it is well known that the plume from the thruster generates current paths that are very different from what occurs in space, and the neutralization of this plume is also different. For reasons such as this, it is important to clarify how the experimental testing environment affects plasma flows, but understanding this effect solely through ground experiments is difficult. To that end, this study utilizes particle-in-cell and direct simulation Monte Carlo methods to simulate xenon beam ions and electrons emitted from a neutralizer. First, we compare simulations conducted within the chamber to those conducted in space, demonstrating that grounded chamber walls increase the electric potential and electron temperature. Next, we investigate the impact of the neutralizer's position and the background pressure on the plume in the vacuum chamber. We find that as the neutralizer position moves closer to the location of maximum potential, more electrons are extracted, resulting in increased neutralization of the plume. We also observe that high background pressure generates slow charge-exchange ions, creating ion sheaths on the side walls that alter ion current paths. Finally, we discuss how the potential at the thruster and neutralizer exits affects the plume. The relative potential of the neutralizer to the vacuum chamber wall is observed to significantly influence the behavior of the electrons, thereby altering the degree of plume neutralization. These findings are shown to be consistent with experimental results in the literature and demonstrate the promise of high-performance simulation.
△ Less
Submitted 29 June, 2023;
originally announced June 2023.
-
Photophoretic Light-flyers with Germanium Coatings as Selective Absorbers
Authors:
Zhipeng Lu,
Gulzhan Aldan,
Danielle Levin,
Matthew F. Campbell,
Igor Bargatin
Abstract:
The goal of ultrathin lightweight photophoretic flyers, or light-flyers for short, is to levitate continuously in Earth's upper atmosphere using only sunlight for propulsive power. We previously reported light-flyers that levitated by utilizing differences in thermal accommodation coefficient (TAC) between the top and bottom of a thin film, made possible by coating their lower surfaces with carbon…
▽ More
The goal of ultrathin lightweight photophoretic flyers, or light-flyers for short, is to levitate continuously in Earth's upper atmosphere using only sunlight for propulsive power. We previously reported light-flyers that levitated by utilizing differences in thermal accommodation coefficient (TAC) between the top and bottom of a thin film, made possible by coating their lower surfaces with carbon nanotubes (CNTs). Such designs, though successful, were limited due to their high thermal emissivity (>0.5), which prevented them from achieving high temperatures and resulted in their transferring relatively low amounts of momentum to the surrounding gas. To address this issue, we have developed light-flyers with undoped germanium layers that selectively absorb nearly 80% of visible light but are mostly transparent in the thermal infrared, with an average thermal emissivity of <0.1. Our experiments show that germanium-coated light-flyers could levitate at up to 43% lower light irradiances than mylar-CNT disks with identical sizes. In addition, we simulated our experiments using a combined first-principles-empirical model, allowing us to predict that our 2-cm-diameter disk-shaped germanium-coated light-flyers can levitate in the mesosphere (altitudes 68-78 km) under the natural sunlight (1.36 kW/m2). Similar ultrathin selective-absorber coatings can also be applied to three-dimensional light-flyers shaped like solar balloons, allowing them to carry significant payloads and thereby revolutionize long-term atmospheric exploration of Earth or Mars.
△ Less
Submitted 30 May, 2023;
originally announced May 2023.
-
A Prototype Scintillator Real-Time Beam Monitor for Ultra-high Dose Rate Radiotherapy
Authors:
Daniel S. Levin,
Peter S. Friedman,
Claudio Ferretti,
Nicholas Ristow,
Monica Tecchio,
Dale W. Litzenberg,
Vladimir Bashkirov,
Reinhard Schulte
Abstract:
FLASH Radiotherapy (RT) is a potentially new cancer radiotherapy technique where an entire therapeutic dose is delivered in about 0.1 s and at ~1000 times higher dose rate than in conventional RT. For clinical trials to be conducted safely, precise and fast beam monitoring that can generate an out-of-tolerance beam interrupt is required. A FLASH Beam Scintillator Monitor (FBSM) is being developed…
▽ More
FLASH Radiotherapy (RT) is a potentially new cancer radiotherapy technique where an entire therapeutic dose is delivered in about 0.1 s and at ~1000 times higher dose rate than in conventional RT. For clinical trials to be conducted safely, precise and fast beam monitoring that can generate an out-of-tolerance beam interrupt is required. A FLASH Beam Scintillator Monitor (FBSM) is being developed based in part on a novel proprietary inorganic hybrid scintillator material. The FBSM provides large area coverage, low mass profile, linear response over a broad dynamic range, radiation tolerance, and real-time analysis IEC-compliant fast beam-interrupt signal. This paper includes the design concept and test results from a prototype device in radiation beams that include heavy ions, FLASH level dose per pulse electron beams, anda hospital radiotherapy clinic with electron beams. Results include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The scintillator showed a small -0.02%/kGy signal decrease after a 212 kGy cumulative dose resulting from continuous exposure for 15 minutes at a FLASH compatible dose rate of 234 Gy/s. These tests established the linear response of the FBSM with respect to dose per pulse. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile. At 20 kfps or 50 microsec/frame, the real-time FPGA based computation and analysis of beam position, beam shape, and beam dose takes < 1 microsec.
△ Less
Submitted 8 March, 2024; v1 submitted 24 May, 2023;
originally announced May 2023.
-
Three-Dimensional Kinetic Simulation of an Ion Thruster Plume with Carbon Backsputtering in a Vacuum Chamber
Authors:
Keita Nishii,
Deborah A. Levin
Abstract:
Gridded ion thrusters are tested in ground vacuum chambers to verify their performance when deployed in space. However, the presence of high background pressure and conductive walls in the chamber leads to facility effects that increase uncertainty in the performance of the thruster in space. To address this issue, this study utilizes a fully kinetic simulation to investigate the facility effects…
▽ More
Gridded ion thrusters are tested in ground vacuum chambers to verify their performance when deployed in space. However, the presence of high background pressure and conductive walls in the chamber leads to facility effects that increase uncertainty in the performance of the thruster in space. To address this issue, this study utilizes a fully kinetic simulation to investigate the facility effects on the thruster plume. The in-chamber condition shows a downstream neutral particle density 100 times larger than the in-space case due to ion neutralization at the wall and limited vacuum pump capability, resulting in a significant difference in the density and distribution of charge-exchange ions. The flux, energy, and angle of charge-exchange ions incident on the chamber wall are found to be altered by the electron sheath, which can only be simulated by the fully kinetic approach, as opposed to the conventionally used quasi-neutral Boltzmann approach. We also examine the effect of backsputtering, another important facility effect, and find that it does not necessarily require a fully kinetic simulation as the incident flux and energy of the sampled charge-exchange ion are negligibly small. Finally, we demonstrate that the carbon deposition rate on the thruster is significantly influenced by the angular dependence of the sputtered carbon, with a nearly 50% effect.
△ Less
Submitted 16 March, 2023; v1 submitted 13 March, 2023;
originally announced March 2023.
-
A High Performance Scintillator Ion Beam Monitor
Authors:
Daniel S Levin,
Peter S. Friedman,
Tom Ginter,
Claudio Ferretti,
Alexander Kaipainen,
Nicholas Ristow
Abstract:
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without breaking vacuum. Scintillators are: 1) a semicrystalline polymer material (PM) film, 1-200 microns thick; 2) A 100-400 micron thick opaque wafer consisting of a h…
▽ More
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without breaking vacuum. Scintillators are: 1) a semicrystalline polymer material (PM) film, 1-200 microns thick; 2) A 100-400 micron thick opaque wafer consisting of a hybrid of inorganic-polymer (HM) plastic matrix. The SIBM was demonstrated at the Facility of Rare Isotope Beams (FRIB, East Lansing, MI) real-time beam profile and rate analysis spanning more than five orders of magnitude including visualization of single ion signals. It may replace FRIB reference detectors: Faraday cup, silicon strips and a micro-channel plate.
△ Less
Submitted 31 August, 2022;
originally announced August 2022.
-
Excitation of electrostatic solitary waves and surface waves in ion beam neutralization process
Authors:
Nakul Nuwal,
Igor D. Kaganovich,
Deborah A. Levin
Abstract:
Unusually long electrostatic solitary waves (ESWs) are discovered in 2D and 3D Particle-in-Cell studies of the process of ion beam neutralization by electron emission from filaments. These ESWs are long because trapped and untrapped electron density perturbations nearly compensate each other. Surface waves were discovered in the process of neutralization but were only observed in 3D simulations. T…
▽ More
Unusually long electrostatic solitary waves (ESWs) are discovered in 2D and 3D Particle-in-Cell studies of the process of ion beam neutralization by electron emission from filaments. These ESWs are long because trapped and untrapped electron density perturbations nearly compensate each other. Surface waves were discovered in the process of neutralization but were only observed in 3D simulations. This is because the phase velocity of surface waves in a 2D geometry is higher than in 3D giving the high-energy electrons generated upstream near the electron source enough energy to excite such waves only in 3D cylindrical beams.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Kinetic modeling of three-dimensional electrostatic-solitary and surface waves in beam neutralization
Authors:
Nakul Nuwal,
Deborah A. Levin,
Igor D. Kaganovich
Abstract:
This work studies the fundamental plasma processes involved in the neutralization of an ion beam's space-charge by electrons emitted by a filament using Particle-in-Cell simulations. While filament neutralization is economical, previous experiments have shown that a variety of waves become excited in this process that limit the space-charge neutralization. In this work, the formation and movement…
▽ More
This work studies the fundamental plasma processes involved in the neutralization of an ion beam's space-charge by electrons emitted by a filament using Particle-in-Cell simulations. While filament neutralization is economical, previous experiments have shown that a variety of waves become excited in this process that limit the space-charge neutralization. In this work, the formation and movement of electrostatic solitary waves(ESWs), which have low dissipation rates, are characterized for 2D planar and 3D cylindrical beams and are observed to generate waves that survive for a long time and slow the process of beam neutralization. Further, through a 1D Bernstein-Greene-Kruskal (BGK) analysis, we find that the non-Maxwellian nature of the beam electrons gives rise to large-sized ESWs that are not predicted by theory which assumes that the electrons may be described by a Maxwellian distribution. Our PIC simulations are sufficiently sensitive to be able to resolve important three-dimensional effects in a 3D cylindrical geometry that lead to the excitation of Trivelpiece-Gould surface waves due to high-energy electrons present at the beginning of neutralization.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Linear stability analysis of hypersonic boundary layers computed by a kinetic approach: A semi-infinite flat plate at Mach 4.5 and 9
Authors:
Angelos Klothakis,
Helio Quintanilha Jr,
Saurabh S. Sawant,
Eftychios Protopapadakis,
Vassilis Theofilis,
Deborah A. Levin
Abstract:
Linear stability analysis is performed using a combination of two-dimensional Direct Simulation Monte Carlo (DSMC) method for the computation of the basic state and solution of the pertinent eigenvalue problem, as applied to the canonical boundary layer on a semi-infinite flat plate. Three different gases are monitored, namely nitrogen, argon and air, the latter as a mixture of 79\% Nitrogen and 2…
▽ More
Linear stability analysis is performed using a combination of two-dimensional Direct Simulation Monte Carlo (DSMC) method for the computation of the basic state and solution of the pertinent eigenvalue problem, as applied to the canonical boundary layer on a semi-infinite flat plate. Three different gases are monitored, namely nitrogen, argon and air, the latter as a mixture of 79\% Nitrogen and 21\% Oxygen at a range of free-stream Mach numbers corresponding to flight at an altitude of 55km. A neural network has been utilised to predict and smooth the raw DSMC data; the steady laminar profiles obtained are in very good agreement with those computed by (self-similar) boundary layer theory, under isothermal or adiabatic wall conditions, subject to the appropriate slip corrections computed in the DSMC method.
The leading eigenmode results pertaining to the unsmoothed DSMC profiles are compared against those of the classic boundary layer theory. Small quantitative, but no significant qualitative differences between the results of the two classes of steady base flows have been found at all parameters examined. The frequencies of the leading eigenmodes at all conditions examined are practically identical, while perturbations corresponding to the DSMC profiles are found to be systematically more damped than their counterparts arising in the boundary layer at the conditions examined, when the correct velocity slip and temperature jump boundary conditions are imposed in the base flow profiles; by contrast, when the classic no-slip boundary conditions are used, less damped/more unstable profiles are obtained, which would lead the flow to earlier transition. On the other hand, the DSMC profiles smoothed by the neural network are marginally more stable than their unsmoothed counterparts.
△ Less
Submitted 26 April, 2021;
originally announced April 2021.
-
Kinetic modelling of three-dimensional shock/laminar separation bubble instabilities in hypersonic flows over a double wedge
Authors:
Saurabh S. Sawant,
Vassilios Theofilis,
Deborah A. Levin
Abstract:
Linear global instability of the three-dimensional (3-D), spanwise-homogeneous laminar separation bubble (LSB) induced by shock-wave/boundary-layer interaction (SBLI) in a Mach 7 flow of nitrogen over a $30^{\circ}-55^{\circ}$ double wedge is studied. At these conditions corresponding to a freestream unit Reynolds number, $Re_1=5.2\times 10^{4}$ m$^{-1}$, the flow exhibits rarefaction effects and…
▽ More
Linear global instability of the three-dimensional (3-D), spanwise-homogeneous laminar separation bubble (LSB) induced by shock-wave/boundary-layer interaction (SBLI) in a Mach 7 flow of nitrogen over a $30^{\circ}-55^{\circ}$ double wedge is studied. At these conditions corresponding to a freestream unit Reynolds number, $Re_1=5.2\times 10^{4}$ m$^{-1}$, the flow exhibits rarefaction effects and comparable shock-thicknesses to the size of the boundary-layer at separation. This, in turn, requires the use of the high-fidelity Direct Simulation Monte Carlo (DSMC) method to accurately resolve unsteady flow features.
We show for the first time that the LSB sustains self-excited, small-amplitude, 3-D perturbations that lead to spanwise-periodic flow structures not only in and downstream of the separated region, as seen in a multitude of experiments and numerical simulations, but also in the internal structure of the separation and detached shock layers. The spanwise-periodicity length and growth rate of the structures in the two zones are found to be identical. It is shown that the linear global instability leads to low-frequency unsteadiness of the triple point formed by the intersection of separation and detached shocks, corresponding to a Strouhal number of $St\sim0.02$. Linear superposition of the spanwise-homogeneous base flow and the leading 3-D flow eigenmode provides further evidence of the strong coupling between linear instability in the LSB and the shock layer.
△ Less
Submitted 22 January, 2021;
originally announced January 2021.
-
Linear Instability of Shock-Dominated Laminar Hypersonic Separated Flows
Authors:
Saurabh S. Sawant,
Ozgur Tumuklu,
Vassilis Theofilis,
Deborah A. Levin
Abstract:
The self-excited spanwise homogeneous perturbations arising in shock-wave/boundary-layer interaction (SWBLI) system formed in a hypersonic flow of molecular nitrogen over a double wedge are investigated using the kinetic Direct Simulation Monte Carlo (DSMC) method. The flow has transitional Knudsen and unit Reynolds numbers of 3.4 x 10$^{-3}$ and 5.2 x 10$^4$ m$^{-1}$, respectively. Strong thermal…
▽ More
The self-excited spanwise homogeneous perturbations arising in shock-wave/boundary-layer interaction (SWBLI) system formed in a hypersonic flow of molecular nitrogen over a double wedge are investigated using the kinetic Direct Simulation Monte Carlo (DSMC) method. The flow has transitional Knudsen and unit Reynolds numbers of 3.4 x 10$^{-3}$ and 5.2 x 10$^4$ m$^{-1}$, respectively. Strong thermal nonequilibrium exists downstream of the Mach 7 detached (bow) shock generated due to the upper wedge surface. A linear instability mechanism is expected to make the pre-computed 2-D base flow potentially unstable under spanwise perturbations. The specific intent is to assess the growth rates of unstable modes, the wavelength, location, and origin of spanwise periodic flow structures, and the characteristic frequencies present in this interaction.
△ Less
Submitted 10 January, 2021;
originally announced January 2021.
-
Analytical Prediction of Low-Frequency Fluctuations Inside a One-Dimensional Shock
Authors:
Saurabh S. Sawant,
Deborah A. Levin,
Vassilios Theofilis
Abstract:
Linear instability of high-speed boundary layers is routinely examined assuming quiescent edge conditions, without reference to the internal structure of shocks or to instabilities potentially generated in them. Our recent work has shown that the kinetically modeled internal nonequilibrium zone of straight shocks away from solid boundaries exhibits low-frequency molecular fluctuations. The presenc…
▽ More
Linear instability of high-speed boundary layers is routinely examined assuming quiescent edge conditions, without reference to the internal structure of shocks or to instabilities potentially generated in them. Our recent work has shown that the kinetically modeled internal nonequilibrium zone of straight shocks away from solid boundaries exhibits low-frequency molecular fluctuations. The presence of the dominant low frequencies observed using the Direct Simulation Monte Carlo (DSMC) method has been explained as a consequence of the well-known bimodal probability density function (PDF) of the energy of particles inside a shock. Here, PDFs of particle energies are derived in the upstream and downstream equilibrium regions, as well as inside shocks, and it is shown for the first time that they have the form of the non-central chi-squared (NCCS) distributions. A linear correlation is proposed to relate the change in the shape of the analytical PDFs as a function of Mach number, within the range $3 \le M \le 10$, with the DSMC-derived average characteristic low-frequency of shocks, as computed in our earlier work. At a given Mach number $M=7.2$, varying the input translational temperature in the range $89 \le T_{tr,1}/(K) \le 1420$, it is shown that the variation in DSMC-derived low-frequencies is correlated with the change in most-probable-speed inside shocks at the location of maximum bulk velocity gradient. Using the proposed linear functions, average low-frequencies are estimated within the examined ranges of Mach number and input temperature and a semi-empirical relationship is derived to predict low-frequency oscillations in shocks. Our model can be used to provide realistic physics-based boundary conditions in receptivity and linear stability analysis studies of laminar-turbulent transition in high-speed flows.
△ Less
Submitted 3 January, 2021;
originally announced January 2021.
-
A Kinetic Approach to Studying Low-Frequency Molecular Fluctuations in a One-Dimensional Shock
Authors:
Saurabh S. Sawant,
Deborah A. Levin,
Vassilios Theofilis
Abstract:
Low-frequency molecular fluctuations in the translational nonequilibrium zone of one-dimensional strong shock waves are characterised for the first time in a kinetic collisional framework in the Mach number range $2\le M\le 10$. Our analysis draws upon the well-known bimodal nature of the probability density function (PDF) of gas particles in the shock, as opposed to their Maxwellian distribution…
▽ More
Low-frequency molecular fluctuations in the translational nonequilibrium zone of one-dimensional strong shock waves are characterised for the first time in a kinetic collisional framework in the Mach number range $2\le M\le 10$. Our analysis draws upon the well-known bimodal nature of the probability density function (PDF) of gas particles in the shock, as opposed to their Maxwellian distribution in the freestream, the latter exhibiting an order of magnitude higher dominant frequencies than the former. Inside the (finite-thickness) shock region, the strong correlation between perturbations in the bimodal PDF and fluctuations in the normal stress suggests introducing a novel two-bin model to describe the reduced-order dynamics of a large number of collision interactions of gas particles. Our model correctly predicts the order-of-magnitude difference in fluctuation frequencies in the shock versus those in the freestream and is consistent with the small-amplitude fluctuations obtained from the highly resolved Direct Simulation Monte Carlo (DSMC) computations of the same configuration. The variation of low-frequency fluctuations with changes in the conditions upstream of the shock revealed that these fluctuations can be described by a Strouhal number, based on the bulk velocity upstream of the shock and the shock-thickness based on the maximum density-gradient inside the shock, that remains practically independent of Mach number in the range examined. Our results are expected to have far-reaching implications for boundary conditions employed in the vicinity of shocks in the framework of flow instability and laminar-turbulent transition studies of flows containing both unsteady and nominally stationary shocks.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
Electron Backscattered Diffraction using a New Monolithic Direct Detector: High Resolution and Fast Acquisition
Authors:
Fulin Wang,
McLean P. Echlin,
Aidan A. Taylor,
Jungho Shin,
Benjamin Bammes,
Barnaby D. A. Levin,
Marc De Graef,
Tresa M. Pollock,
Daniel S. Gianola
Abstract:
A monolithic active pixel sensor based direct detector that is optimized for the primary beam energies in scanning electron microscopes is implemented for electron back-scattered diffraction (EBSD) applications. The high detection efficiency of the detector and its large array of pixels allow sensitive and accurate detection of Kikuchi bands arising from primary electron beam excitation energies o…
▽ More
A monolithic active pixel sensor based direct detector that is optimized for the primary beam energies in scanning electron microscopes is implemented for electron back-scattered diffraction (EBSD) applications. The high detection efficiency of the detector and its large array of pixels allow sensitive and accurate detection of Kikuchi bands arising from primary electron beam excitation energies of 4 keV to 28 keV, with the optimal contrast occurring in the range of 8-16 keV. The diffraction pattern acquisition speed is substantially improved via a sparse sampling mode, resulting from the acquisition of a reduced number of pixels on the detector. Standard inpainting algorithms are implemented to effectively estimate the information in the skipped regions in the acquired diffraction pattern. For EBSD mapping, a speed as high as 5988 scan points per second is demonstrated, with a tolerable fraction of indexed points and accuracy. The collective capabilities spanning from high angular resolution EBSD pattern to high speed pattern acquisition are achieved on the same detector, facilitating simultaneous detection modalities that enable a multitude of advanced EBSD applications, including lattice strain mapping, structural refinement, low-dose characterization, 3D-EBSD and dynamic in situ EBSD.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Tracking the Picoscale Spatial Motion of Atomic Columns During Dynamic Structural Change
Authors:
Barnaby D. A. Levin,
Ethan L. Lawrence,
Peter A. Crozier
Abstract:
In many materials systems, such as catalytic nanoparticles, the ability to characterize dynamic atomic structural changes is important for developing a more fundamental understanding of functionality. Recent developments in direct electron detection now allow image series to be acquired at frame rates on the order of 1000 frames per second in bright-field transmission electron microscopy (BF TEM),…
▽ More
In many materials systems, such as catalytic nanoparticles, the ability to characterize dynamic atomic structural changes is important for developing a more fundamental understanding of functionality. Recent developments in direct electron detection now allow image series to be acquired at frame rates on the order of 1000 frames per second in bright-field transmission electron microscopy (BF TEM), which could potentially allow dynamic changes in the atomic structure of individual nanoparticles to be characterized with millisecond temporal resolution in favourable cases. However, extracting such data from TEM image series requires the development of computational methods that can be applied to very large datasets and are robust in the presence of noise and in the non-ideal imaging conditions of some types of environmental TEM experiments. Here, we present a two-dimensional Gaussian fitting algorithm to track the position and intensities of atomic columns in temporally resolved BF TEM image series. We have tested our algorithm on experimental image series of Ce atomic columns near the surface of a ceria (CeO2) nanoparticle with electron beam doses of ~125-5000 e-Å-2 per frame. The accuracy of the algorithm for locating atomic column positions is compared to that of the more traditional centroid fitting technique, and the accuracy of intensity measurements is evaluated as a function of dose per frame. The code developed here, and the methodology used to explore the errors and limitations of the measurements, could be applied more broadly to any temporally resolved TEM image series to track dynamic atomic column motion.
△ Less
Submitted 27 March, 2020; v1 submitted 16 September, 2019;
originally announced September 2019.
-
Nanopatterned electron beams for temporal coherence and deterministic phase control of x-ray free-electron lasers
Authors:
W. S. Graves,
S. L. Y. Chang,
D. Dwyer,
P. Fromme,
M. Holl,
B. D. A. Levin,
L. E. Malin,
J. L. Vincent,
J. C. H. Spence,
E. A. Nanni,
R. K. Li,
X. Shen,
S. Weathersby,
A. Sandhu
Abstract:
We demonstrate the ability to create electron beams with high-contrast, nanometer-scale density modulations as a first step toward developing full control of the phase fronts of an x-ray free-electron laser. The nanopatterned electron beams are produced by diffracting electrons through thin single-crystal silicon membranes that are lithographically patterned to different thicknesses. For transform…
▽ More
We demonstrate the ability to create electron beams with high-contrast, nanometer-scale density modulations as a first step toward developing full control of the phase fronts of an x-ray free-electron laser. The nanopatterned electron beams are produced by diffracting electrons through thin single-crystal silicon membranes that are lithographically patterned to different thicknesses. For transform-limited x-ray production the desired pattern is a series of regularly spaced lines (i.e. a grating) that generate uniformly spaced nanobunches of electrons, however nearly any pattern can be etched in the silicon, such as frequency-chirps or multiple patterns of different colors or line spacings. When these patterns are transferred from the spatial to the temporal dimension by accelerator electromagnetic optics they will control the phase fronts of coherent x-rays, giving unprecedented deterministic control over the phase of ultrashort x-ray pulses. In short, this method allows the time-structure for a fully coherent x-ray beam to be generated from a pattern written on a semiconductor wafer by lithography.
△ Less
Submitted 4 June, 2019;
originally announced June 2019.
-
Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode
Authors:
A. Mulski,
Y. Benhammou,
J. W. Chapman,
A. Das,
E. Etzion,
C. Ferretti,
P. S. Friedman,
R. P. Johnson,
D. S. Levin,
N. Kamp,
H. Ochoa,
M. Raviv-Moshe,
N. Ristow
Abstract:
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and her…
▽ More
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and hermetically sealed gaseous tracking detector with high rate ( > 100 KHz/cm^2 ) capability. The devices reported here were fabricated as 16 x 16 pixel arrays of 2 mm edge-to-edge, 1 mm deep hexagonal cells embedded in a thin, 1.4 mm glass-ceramic wafer. Cell walls are metalized cathodes, connected to high voltage bus lines through conductive vias. Anodes are small, 457 micron diameter metal discs screen printed on the upper substrate. The detectors are filled with an operating gas to near 1 atm and then closed with a shut-off valve. They have been operated in both avalanche mode and gas discharge devices, producing mV to volt level signals with about 1 to 3 ns rise times. Operation in discharge mode is enabled by high impedance quench resistors on the high voltage bus at each pixel site. Results indicate that each individual pixel behaves as an isolated detection unit with high single pixel intrinsic efficiency to both beta's from radioactive sources and to cosmic ray muons. Continuous avalanche mode operation over several days at hit rates over 300 KHz/cm^2 with no gas flow have been observed. Measurements of pixel isolation, timing response, efficiency, hit rate and rate stability are reported.
△ Less
Submitted 24 October, 2018;
originally announced October 2018.
-
Performance of a First Microhexcavity Plasma Panel Detector with Muons
Authors:
Alexis Mulski,
Yan Benhamou,
Erez Etzion,
Claudio Ferretti,
Peter S. Friedman,
Daniel S. Levin,
Meny Raviv Moshe,
David Reikher,
Nicholas Ristow
Abstract:
The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an independent detection unit. The response of the detector to ionizing radiation was investigated using low-energy radioactive $ β$ sources and cosmic ray muons. Efficiency…
▽ More
The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an independent detection unit. The response of the detector to ionizing radiation was investigated using low-energy radioactive $ β$ sources and cosmic ray muons. Efficiency measurements were conducted with cosmic ray muons in conjunction with a scintillator hodoscope. The rate response and signals obtained from the microhexcavity detector filled with Penning gas mixture at atmospheric pressure are herein described. The relative pixel efficiency, after allowing for ion-pair formation in the gas volume, is 96.8 $ \pm $ 4.4$ \% $ for operation of the detector above an applied high voltage of 1000 V.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Microhexcavity Plasma Panel Detectors
Authors:
Alexis Mulski,
Daniel S. Levin,
Yan Benhamou,
John W. Chapman,
Achintya Das,
Erez Etzion,
Claudio Ferretti,
Peter S. Friedman,
Meny Raviv-Moshe,
David Reikher,
Nicholas Ristow
Abstract:
Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydr…
▽ More
Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydrocarbon gas mixtures. The newest variant of these closed-architecture detectors is known as the Microhexcavity plasma panel detector ($μ$Hex) consisting of 2 mm wide, regular close-packed hexagonal pixels each with a circular thick-film anode. The fabrication, staging, and operation of these detectors is described. Initial tests with the $μ$Hex detectors operated in Geiger mode yield Volt-level signals in the presence of ionizing radiation. The spontaneous discharge rate in the absence of a source is roughly 3-4 orders of magnitude lower compared to the rates measured using low energy betas.
△ Less
Submitted 18 September, 2017; v1 submitted 13 September, 2017;
originally announced September 2017.
-
Dependence of effective spectrum width of synchrotron radiation on particle energy
Authors:
V. G. Bagrov,
D. M. Gitman,
A. D. Levin,
A. S. Loginov,
A. D. Saprykin
Abstract:
For an exact quantitative description of spectral properties in the theory of synchrotron radiation, the concept of effective spectral width is introduced. In the classical theory, numeric calculations of effective spectral width (using an effective width not exceeding 100 harmonics) for polarization components of synchrotron radiation are carried out. The dependence of the effective spectral widt…
▽ More
For an exact quantitative description of spectral properties in the theory of synchrotron radiation, the concept of effective spectral width is introduced. In the classical theory, numeric calculations of effective spectral width (using an effective width not exceeding 100 harmonics) for polarization components of synchrotron radiation are carried out. The dependence of the effective spectral width and initial harmonic on the energy of a radiating particle is established.
△ Less
Submitted 5 April, 2017; v1 submitted 7 March, 2017;
originally announced March 2017.
-
Nanomaterial datasets to advance tomography in scanning transmission electron microscopy
Authors:
Barnaby D. A. Levin,
Elliot Padgett,
Chien-Chun Chen,
M. C. Scott,
Rui Xu,
Wolfgang Theis,
Yi Jiang,
Yongsoo Yang,
Colin Ophus,
Haitao Zhang,
Don-Hyung Ha,
Deli Wang,
Yingchao Yu,
Hector D. Abruna,
Richard D. Robinson,
Peter Ercius,
Lena F. Kourkoutis,
Jianwei Miao,
David A. Muller,
Robert Hovden
Abstract:
Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in ord…
▽ More
Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co2P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.
△ Less
Submitted 9 June, 2016;
originally announced June 2016.
-
First results with a microcavity plasma panel detector
Authors:
R. Ball,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
M. Davies,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
B. Zhou
Abstract:
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles fro…
▽ More
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3 to 4 orders of magnitude lower than the rate with the cell illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.
△ Less
Submitted 3 December, 2014; v1 submitted 24 July, 2014;
originally announced July 2014.
-
Development of a plasma panel radiation detector
Authors:
R. Ball,
J. R. Beene,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
R. Wetzel,
B. Zhou,
T. Anderson,
K. McKinny,
E. H. Bentefour
Abstract:
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were t…
▽ More
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were tested with cosmic ray muons, beta rays and gamma rays, protons and thermal neutrons. The results demonstrated rise times and time resolution of a few nanoseconds, as well as sub-millimeter spatial resolution compatible with the pixel pitch.
△ Less
Submitted 14 June, 2014; v1 submitted 13 March, 2014;
originally announced March 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Plasma panel-based radiation detectors
Authors:
Peter Friedman,
Robert Ball,
James Beene,
Yan Benhammou,
Meny Ben-Moshe,
Hassan Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Daniel Levin,
Yiftah Silver,
Robert Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates…
▽ More
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (<50-mm RMS) and low cost. In this paper, we report on prototype PPS experimental results in detecting betas, protons, and cosmic muons, and we extrapolate on the PPS potential for applications including the detection of alphas, heavy ions at low-to-medium energy, thermal neutrons, and X-rays.
△ Less
Submitted 10 May, 2013;
originally announced May 2013.
-
Plasma Panel Sensors for Particle and Beam Detection
Authors:
Peter S. Friedman,
Robert Ball,
James R. Beene,
Yan Benhammou,
E. H. Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Daniel S. Levin,
Meny Ben-Moshe,
Yiftah Silver,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials…
▽ More
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials such as glass substrates, metal electrodes and mostly inert gas mixtures. We are developing the technology to fabricate these devices with very low mass and small thickness, using gas gaps of at least a few hundred micrometers. Our tests with these devices demonstrate a spatial resolution of about 1 mm. We intend to make PPS devices with much smaller cells and the potential for much finer position resolutions. Our PPS tests also show response times of several nanoseconds. We report here our results in detecting betas, cosmic-ray muons, and our first proton beam tests.
△ Less
Submitted 22 November, 2012;
originally announced November 2012.
-
Studies on fast triggering and high precision tracking with Resistive Plate Chambers
Authors:
G. Aielli,
B. Bilki,
R. Ball,
J. W. Chapman,
R. Cardarelli,
T. Dai,
E. Diehl,
J. Dubbert,
C. Ferretti,
H. Feng,
K. Francis,
L. Guan,
L. Han,
S. Hou,
D. Levin,
B. Li,
L. Liu,
L. Paolozzi,
J. Repond,
J. Roloff,
R. Santonico,
H. Y. Song,
X. L. Wang,
Y. Wu,
L. Xia
, et al. (5 additional authors not shown)
Abstract:
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering…
▽ More
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 um using charge information and 287 um using timing information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.
△ Less
Submitted 24 October, 2012;
originally announced October 2012.
-
Development of a plasma panel radiation detector: recent progress and key issues
Authors:
Yiftah Silver,
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben-Moshe,
J. W. Chapman,
Tiesheng Dai,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Peter S. Friedman,
Daniel S. Levin,
S. Ritt,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pi…
▽ More
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.
△ Less
Submitted 30 May, 2012;
originally announced May 2012.
-
The Detection of Ionizing Radiation by Plasma Panel Sensors: Cosmic Muons, Ion Beams and Cancer Therapy
Authors:
Peter S. Friedman,
Robert Ball,
J. W. Chapman,
Claudio Ferretti,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
Nir Guttman,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
△ Less
Submitted 3 April, 2012;
originally announced April 2012.
-
Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running
Authors:
N. Amram,
R. Ball,
Y. Benhammou,
M. Ben Moshe,
T. Dai,
E. B. Diehl,
J. Dubbert,
E. Etzion,
C. Ferretti,
J. Gregory,
S. Haider,
J. Hindes,
D. S. Levin,
R. Thun,
A. Wilson,
C. Weaverdyck,
Y. Wu,
H. Yang,
B. Zhou,
S. Zimmermann
Abstract:
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT function…
▽ More
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.
△ Less
Submitted 7 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Progress in the Development of Plasma Panel Radiation Detectors
Authors:
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben Moshe,
J. Wehrley Chapman,
Tiesheng Dai,
Erez Etzion,
Peter S. Friedman,
Daniel S. Levin,
Yiftah Silver,
Guy Sherman,
Robert L. Varner Jr.,
Curtis Weaverdyck,
Steve White,
J. Yu,
Bing Zhou
Abstract:
Plasma Display Panels (PDP), the underlying engine of panel plasma television displays, are being investigated for their utility as radiation detectors called Plasma Panel Sensors (PPS). The PPS a novel variant of a micropattern radiation detector, is intended to be a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We r…
▽ More
Plasma Display Panels (PDP), the underlying engine of panel plasma television displays, are being investigated for their utility as radiation detectors called Plasma Panel Sensors (PPS). The PPS a novel variant of a micropattern radiation detector, is intended to be a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We report on the PPS development effort, including recent laboratory measurements.
△ Less
Submitted 30 December, 2010;
originally announced January 2011.
-
Large-Area Plasma-Panel Radiation Detectors for Nuclear Medicine Imaging to Homeland Security and the Super Large Hadron Collider
Authors:
Peter S. Friedman,
Robert Ball,
J. Wehrley Chapman,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.
A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.
△ Less
Submitted 3 July, 2010;
originally announced July 2010.
-
Plasma Panel Detectors for MIP Detection for the SLHC and a Test Chamber Design
Authors:
Robert Ball,
John W. Chapman,
Erez Etzion,
Peter S. Friedman,
Daniel S. Levin,
Meny Ben Moshe,
Curtis Weaverdyck,
Bing Zhou
Abstract:
Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma tele…
▽ More
Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays. The design and production of PDPs is supported by four decades of industrial development. Emerging from this television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally an array of micro-Geiger plasma discharge cells operating in a non-ageing, hermetically sealed gas mixture . We report on the PPS development program, including design of a PPS Test Cell.
△ Less
Submitted 3 July, 2010;
originally announced July 2010.