-
Two-neutrino double electron capture of $^{124}$Xe in the first LUX-ZEPLIN exposure
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
J. W. Bargemann,
E. E. Barillier,
K. Beattie,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer,
C. A. J. Brew
, et al. (180 additional authors not shown)
Abstract:
The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double electron capture (2$ν$2EC), utilizing a $1.39\,\mathrm{kg} \times \mathrm{yr}$ isotopic exposure from the first LZ science run. A half-life of…
▽ More
The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double electron capture (2$ν$2EC), utilizing a $1.39\,\mathrm{kg} \times \mathrm{yr}$ isotopic exposure from the first LZ science run. A half-life of $T_{1/2}^{2\nu2\mathrm{EC}} = (1.09 \pm 0.14_{\text{stat}} \pm 0.05_{\text{sys}}) \times 10^{22}\,\mathrm{yr}$ is observed with a statistical significance of $8.3\,σ$, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the $1.4\,σ$ level.
△ Less
Submitted 30 August, 2024;
originally announced August 2024.
-
The MUSE Beamline Calorimeter
Authors:
W. Lin,
T. Rostomyan,
R. Gilman,
S. Strauch,
C. Meier,
C. Nestler,
M. Ali,
H. Atac,
J. C. Bernauer,
W. J. Briscoe,
A. Christopher Ndukwe,
E. W. Cline,
K. Deiters,
S. Dogra,
E. J. Downie,
Z. Duan,
I. P. Fernando,
A. Flannery,
D. Ghosal,
A. Golossanov,
J. Guo,
N. S. Ifat,
Y. Ilieva,
M. Kohl,
I. Lavrukhin
, et al. (18 additional authors not shown)
Abstract:
The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measuremen…
▽ More
The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron-proton and muon-proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. In this article we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.
△ Less
Submitted 23 August, 2024;
originally announced August 2024.
-
The Design, Implementation, and Performance of the LZ Calibration Systems
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (179 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e…
▽ More
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.
△ Less
Submitted 5 September, 2024; v1 submitted 2 May, 2024;
originally announced June 2024.
-
The Data Acquisition System of the LZ Dark Matter Detector: FADR
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (191 additional authors not shown)
Abstract:
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.…
▽ More
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis.
The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition.
The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.
△ Less
Submitted 16 August, 2024; v1 submitted 23 May, 2024;
originally announced May 2024.
-
Blinding for precision scattering experiments: The MUSE approach as a case study
Authors:
J. C. Bernauer,
E. W. Cline,
H. Atac,
W. J. Briscoe,
A. Christopher Ndukwe,
E. J. Downie,
I. P. Fernando,
T. Gautam,
R. Gilman,
R. Goldin,
M. Kohl,
I. Lavrukhin,
W. Lin,
W. Lorenzon,
P. Mohanmurthy,
S. J. Nazeer,
M. Nicol,
T. Patel,
A. Prosnyakov,
R. D. Ransome,
R. Ratvasky,
H. Reid,
P. E. Reimer,
G. Ron,
T. Rostomyan
, et al. (5 additional authors not shown)
Abstract:
Human bias is capable of changing the analysis of measured data sufficiently to alter the results of an experiment. It is incumbent upon modern experiments, especially those investigating quantities considered contentious in the broader community, to blind their analysis in an effort to minimize bias. The choice of a blinding model is experiment specific, but should also aim to prevent accidental…
▽ More
Human bias is capable of changing the analysis of measured data sufficiently to alter the results of an experiment. It is incumbent upon modern experiments, especially those investigating quantities considered contentious in the broader community, to blind their analysis in an effort to minimize bias. The choice of a blinding model is experiment specific, but should also aim to prevent accidental release of results before an analysis is finalized. In this paper, we discuss common threats to an unbiased analysis, as well as common quantities that can be blinded in different types of nuclear physics experiments. We use the Muon Scattering Experiment as an example, and detail the blinding scheme used therein.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Two-Photon EXchange -- TPEX
Authors:
R. Alarcon,
R. Beck,
J. C. Bernauer,
M. Broering,
E. Cline,
B. Dongwi,
I. Fernando,
M. Finger,
M. Finger Jr.,
I. Friščić,
T. Gautam,
D. K. Hasell,
O. Hen,
J. Holmes,
T. Horn,
E. Ihloff,
R. Johnston,
J. Kelsey,
M. Kohl,
T. Kutz,
I. Lavrukhin,
S. Lee,
W. Lorenzon,
F. Maas,
H. Merkel
, et al. (12 additional authors not shown)
Abstract:
We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of…
▽ More
We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of $2.12\times10^{35}$~cm$^{-2}\cdot$s$^{-1}\cdot$sr$^{-1}$ ($\sim200$ times the luminosity achieved by OLYMPUS). A commissioning run at 2 GeV followed by measurements at 3 GeV would provide new data up to $Q^2=4.6$~(GeV/$c$)$^2$ (twice the range of current measurements). Lead tungstate calorimeters would be used to detect the scattered leptons at polar angles of $30^\circ$, $50^\circ$, $70^\circ$, $90^\circ$, and $110^\circ$. The measurements could be scheduled to not interfere with the operation of PETRA. We present rate estimates and simulations for the planned measurements including background considerations. Initial measurements at the DESY test beam facility using prototype lead tungstate calorimeters in 2019, 2021, and 2022 were made to check the Monte Carlo simulations and the performance of the calorimeters. These tests also investigated different readout schemes (triggered and streaming). Various upgrades are possible to shorten the running time and to make higher beam energies and thus greater $Q^2$ ranges accessible.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
J. Bang,
J. W. Bargemann,
A. Baxter,
K. Beattie,
P. Beltrame,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger,
B. Boxer
, et al. (178 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet…
▽ More
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.
△ Less
Submitted 17 July, 2023; v1 submitted 30 November, 2022;
originally announced November 2022.
-
Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector
Authors:
C. S. Amarasinghe,
R. Coronel,
D. Q. Huang,
Y. Liu,
M. Arthurs,
S. Steinfeld,
R. Gaitskell,
W. Lorenzon
Abstract:
Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below $0.3$ keV$_\text{NR}$ via the asymmetric emission of $γ$ rays during nuclear de-excitation. The fea…
▽ More
Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below $0.3$ keV$_\text{NR}$ via the asymmetric emission of $γ$ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Further, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.
△ Less
Submitted 7 November, 2022;
originally announced November 2022.
-
Feasibility Study to use Neutron Capture for an Ultra-low Energy Nuclear-recoil Calibration in Liquid Xenon
Authors:
C. S. Amarasinghe,
R. Coronel,
D. Q. Huang,
Y. Liu,
M. Arthurs,
S. Steinfeld,
R. Gaitskell,
W. Lorenzon
Abstract:
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. The measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted $γ$…
▽ More
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. The measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted $γ$ cascades can provide the nuclei with up to $0.3$ keV$_\text{nr}$ of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.
△ Less
Submitted 18 October, 2022; v1 submitted 6 April, 2022;
originally announced April 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment
Authors:
E. Cline,
W. Lin,
P. Roy,
P. E. Reimer,
K. E. Mesick,
A. Akmal,
A. Alie,
H. Atac,
A. Atencio,
C. Ayerbe Gayoso,
N. Benmouna,
F. Benmokhtar,
J. C. Bernauer,
W. J. Briscoe,
J. Campbell,
D. Cohen,
E. O. Cohen,
C. Collicott,
K. Deiters,
S. Dogra,
E. Downie,
I. P. Fernando,
A. Flannery,
T. Gautam,
D. Ghosal
, et al. (35 additional authors not shown)
Abstract:
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the prope…
▽ More
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $π$/$μ$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $π$, $μ$, and $e$ scattering.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber
Authors:
R. Linehan,
R. L. Mannino,
A. Fan,
C. M. Ignarra,
S. Luitz,
K. Skarpaas,
T. A. Shutt,
D. S. Akerib,
S. K. Alsum,
T. J. Anderson,
H. M. Araújo,
M. Arthurs,
H. Auyeung,
A. J. Bailey,
T. P. Biesiadzinski,
M. Breidenbach,
J. J. Cherwinka,
R. A. Conley,
J. Genovesi,
M. G. D. Gilchriese,
A. Glaenzer,
T. G. Gonda,
K. Hanzel,
M. D. Hoff,
W. Ji
, et al. (24 additional authors not shown)
Abstract:
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of th…
▽ More
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.
△ Less
Submitted 11 June, 2021;
originally announced June 2021.
-
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe
Authors:
The LUX-ZEPLIN,
Collaboration,
:,
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araujo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert
, et al. (172 additional authors not shown)
Abstract:
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t…
▽ More
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of $^{134}$Xe, for which xenon detectors enriched in $^{136}$Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7$\times$10$^{24}$ years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7$\times$10$^{23}$ years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3$\times$10$^{24}$ years at 90% CL.
△ Less
Submitted 22 November, 2021; v1 submitted 26 April, 2021;
originally announced April 2021.
-
Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
Authors:
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger
, et al. (162 additional authors not shown)
Abstract:
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt…
▽ More
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Performance Study of Charcoal-based Radon Reduction Systems for Ultraclean Rare Event Detectors
Authors:
M. Arthurs,
D. Q. Huang,
C. Amarasinghe,
E. Miller,
W. Lorenzon
Abstract:
The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. $^{222}$Rn produces a particularly problematic background in the physics region of interest by the ``naked'' beta decay of its $^{214}$Pb daughter nucleus. While charcoal-based adsorption traps are expecte…
▽ More
The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. $^{222}$Rn produces a particularly problematic background in the physics region of interest by the ``naked'' beta decay of its $^{214}$Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current {ton-scale} detectors at slow flow rates $(0.5-2\;SLPM)$, radon reduction in the entire circulation loop at high flow rates $\mathcal{O}({100s\;SLPM})$ is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. We find that even for perfect radon traps, circulation speeds of $2,000\;SLPM$ are needed to reduce radon concentration in a 10\,ton detector by 90\%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about $190\,K$, this requirement relaxes drastically.
△ Less
Submitted 6 June, 2021; v1 submitted 13 September, 2020;
originally announced September 2020.
-
Timing Detectors with SiPM read-out for the MUSE Experiment at PSI
Authors:
Tigran Rostomyan,
Ethan Cline,
Ievgen Lavrukhin,
Hamza Atac,
Ariella Atencio,
Jan C. Bernauer,
William J. Briscoe,
Dan Cohen,
Erez O. Cohen,
Cristina Collicott,
Konrad Deiters,
Shraddha Dogra,
Evangeline Downie,
Werner Erni,
Ishara P. Fernando,
Anne Flannery,
Thir Gautam,
Debdeep Ghosal,
Ronald Gilman,
Alexander Golossanov,
Jack Hirschman,
Minjung Kim,
Michael Kohl,
Bernd Krusche,
Lin Li
, et al. (18 additional authors not shown)
Abstract:
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of…
▽ More
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of the scattering target, counts the beam flux and precisely times beam particles both to identify species and provide a starting time for time-of-flight measurements. The Beam Monitor, downstream of the scattering target, counts the unscattered beam flux, helps identify background in scattering events, and precisely times beam particles for time-of-flight measurements. The Beam Focus Monitor, mounted on the target ladder under the liquid hydrogen target inside the target vacuum chamber, is used in dedicated runs to sample the beam spot at three points near the target center, where the beam should be focused.
△ Less
Submitted 15 October, 2020; v1 submitted 23 July, 2020;
originally announced July 2020.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
The LUX-ZEPLIN Collaboration,
:,
D. S. Akerib,
C. W. Akerlof,
A. Alqahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
D. Bauer,
A. Baxter,
J. Bensinger,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
K. E. Boast
, et al. (173 additional authors not shown)
Abstract:
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par…
▽ More
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.
△ Less
Submitted 23 June, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
A Liquid Hydrogen Target for the MUSE Experiment at PSI
Authors:
P. Roy,
S. Corsetti,
M. Dimond,
M. Kim,
L. Le Pottier,
W. Lorenzon,
R. Raymond,
H. Reid,
N. Steinberg,
N. Wuerfel,
K. Deiters,
W. J. Briscoe,
A. Golossanov,
T. Rostomyan
Abstract:
A 280 ml liquid hydrogen target has been constructed and tested for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon-proton and elastic electron-proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. Th…
▽ More
A 280 ml liquid hydrogen target has been constructed and tested for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon-proton and elastic electron-proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target cell wall is made of $120\,μ$m-thick Kapton, while the beam entrance and exit windows are made of $125\,μ$m-thick aluminized Kapton. The side exit windows are made of Mylar laminated on aramid fabric with an areal density of $368\,$g/m$^2$. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This suggests a density stability at the $0.02\,$% level, which is about a factor of ten better than required.
△ Less
Submitted 5 July, 2019;
originally announced July 2019.
-
Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
A. Baxter,
E. P. Bernard,
A. Biekert,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
M. C. Carmona-Benitez,
M. Cascella
, et al. (142 additional authors not shown)
Abstract:
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with…
▽ More
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ $γ$-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of $1.9\pm0.4$~$γ~$cm$^{-2}$s$^{-1}$. The resulting activity in the walls of the cavern can be characterised as $220\pm60$~Bq/kg of $^{40}$K, $29\pm15$~Bq/kg of $^{238}$U, and $13\pm3$~Bq/kg of $^{232}$Th.
△ Less
Submitted 14 November, 2019; v1 submitted 3 April, 2019;
originally announced April 2019.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
Study of radon reduction in gases for rare event search experiments
Authors:
K. Pushkin,
C. Akerlof,
D. Anbajagane,
J. Armstrong,
M. Arthurs,
J. Bringewatt,
T. Edberg,
C. Hall,
M. Lei,
R. Raymond,
M. Reh,
D. Saini,
A. Sander,
J. Schaefer,
D. Seymour,
N. Swanson,
Y. Wang,
W. Lorenzon
Abstract:
The noble elements, argon and xenon, are frequently employed as the target and event detector for weakly interacting particles such as neutrinos and Dark Matter. For such rare processes, background radiation must be carefully minimized. Radon provides one of the most significant contaminants since it is an inevitable product of trace amounts of natural uranium. To design a purification system for…
▽ More
The noble elements, argon and xenon, are frequently employed as the target and event detector for weakly interacting particles such as neutrinos and Dark Matter. For such rare processes, background radiation must be carefully minimized. Radon provides one of the most significant contaminants since it is an inevitable product of trace amounts of natural uranium. To design a purification system for reducing such contamination, the adsorption characteristics of radon in nitrogen, argon, and xenon carrier gases on various types of charcoals with different adsorbing properties and intrinsic radioactive purities have been studied in the temperature range of 190-295 K at flow rates of 0.5 and 2 standard liters per minute. Essential performance parameters for the various charcoals include the average breakthrough times ($τ$), dynamic adsorption coefficients (k$_a$) and the number of theoretical stages (n). It is shown that the k$_a$-values for radon in nitrogen, argon, and xenon increase as the temperature of the charcoal traps decreases, and that they are significantly larger in nitrogen and argon than in xenon gas due to adsorption saturation effects. It is found that, unlike in xenon, the dynamic adsorption coefficients for radon in nitrogen and argon strictly obey the Arrhenius law. The experimental results strongly indicate that nitric acid etched Saratech is the best candidate among all used charcoal brands. It allows reducing total radon concentration in the LZ liquid Xe detector to meet the ultimate goal in the search for Dark Matter.
△ Less
Submitted 29 June, 2018; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
H. M. Araújo,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
D. Bauer,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
B. Carlson
, et al. (153 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up…
▽ More
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector.
For a 1000~live day run using a 5.6~tonne fiducial mass, LZ is projected to exclude at 90\% confidence level spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$~cm$^{2}$ for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5σ$ discovery potential is projected reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.3 \times 10^{-43}$~cm$^{2}$ ($7.1 \times 10^{-42}$~cm$^{2}$) for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
△ Less
Submitted 2 December, 2019; v1 submitted 16 February, 2018;
originally announced February 2018.
-
Spin tracking of polarized protons in the Main Injector at Fermilab
Authors:
M. Xiao,
W. Lorenzon,
C. Aldred
Abstract:
The Main Injector (MI) at Fermilab currently produces high-intensity beams of protons at energies of 120 GeV for a variety of physics experiments. Acceleration of polarized protons in the MI would provide opportunities for a rich spin physics program at Fermilab. To achieve polarized proton beams in the Fermilab accelerator complex, detailed spin tracking simulations with realistic parameters base…
▽ More
The Main Injector (MI) at Fermilab currently produces high-intensity beams of protons at energies of 120 GeV for a variety of physics experiments. Acceleration of polarized protons in the MI would provide opportunities for a rich spin physics program at Fermilab. To achieve polarized proton beams in the Fermilab accelerator complex, detailed spin tracking simulations with realistic parameters based on the existing facility are required. This report presents studies at the MI using a single 4-twist Siberian snake to determine the depolarizing spin resonances for the relevant synchrotrons. Results will be presented first for a perfect MI lattice, followed by a lattice that includes the real MI imperfections, such as the measured magnet field errors and quadrupole misalignments. The tolerances of each of these factors in maintaining polarization in the Main Injector will be discussed.
△ Less
Submitted 27 December, 2017;
originally announced December 2017.
-
Technical Design Report for the Paul Scherrer Institute Experiment R-12-01.1: Studying the Proton "Radius" Puzzle with μp Elastic Scattering
Authors:
R. Gilman,
E. J. Downie,
G. Ron,
S. Strauch,
A. Afanasev,
A. Akmal,
J. Arrington,
H. Atac,
C. Ayerbe-Gayoso,
F. Benmokhtar,
N. Benmouna,
J. Bernauer,
A. Blomberg,
W. J. Briscoe,
D. Cioffi,
E. Cline,
D. Cohen,
E. O. Cohen,
C. Collicott,
K. Deiters,
J. Diefenbach,
B. Dongwi,
D. Ghosal,
A. Golossanov,
R. Gothe
, et al. (34 additional authors not shown)
Abstract:
The difference in proton radii measured with $μp$ atoms and with $ep$ atoms and scattering remains an unexplained puzzle. The PSI MUSE proposal is to measure $μp$ and $e p$ scattering in the same experiment at the same time. The experiment will determine cross sections, two-photon effects, form factors, and radii independently for the two reactions, and will allow $μp$ and $ep$ results to be compa…
▽ More
The difference in proton radii measured with $μp$ atoms and with $ep$ atoms and scattering remains an unexplained puzzle. The PSI MUSE proposal is to measure $μp$ and $e p$ scattering in the same experiment at the same time. The experiment will determine cross sections, two-photon effects, form factors, and radii independently for the two reactions, and will allow $μp$ and $ep$ results to be compared with reduced systematic uncertainties. These data should provide the best test of lepton universality in a scattering experiment to date, about an order of magnitude improvement over previous tests. Measuring scattering with both particle polarities will allow a test of two-photon exchange at the sub-percent level, about a factor of four improvement on uncertainties and over an order of magnitude more data points than previous low momentum transfer determinations, and similar to the current generation of higher momentum transfer electron experiments. The experiment has the potential to demonstrate whether the $μp$ and $ep$ interactions are consistent or different, and whether any difference results from novel physics or two-photon exchange. The uncertainties are such that if the discrepancy is real it should be confirmed with $\approx$5$σ$ significance, similar to that already established between the regular and muonic hydrogen Lamb shift.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
The SeaQuest Spectrometer at Fermilab
Authors:
SeaQuest Collaboration,
C. A. Aidala,
J. R. Arrington,
C. Ayuso,
B. M. Bowen,
M. L. Bowen,
K. L. Bowling,
A. W. Brown,
C. N. Brown,
R. Byrd,
R. E. Carlisle,
T. Chang,
W. -C. Chang,
A. Chen,
J. -Y. Chen,
D. C. Christian,
X. Chu,
B. P. Dannowitz,
M. Daugherity,
M. Diefenthaler,
J. Dove,
C. Durandet,
L. El Fassi,
E. Erdos,
D. M. Fox
, et al. (73 additional authors not shown)
Abstract:
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets…
▽ More
The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.
△ Less
Submitted 9 February, 2019; v1 submitted 29 June, 2017;
originally announced June 2017.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light
Authors:
Jonathan Haefner,
Alissa Neff,
Maris Arthurs,
Elizabeth Batista,
Daniel Morton,
Matt Okunawo,
Kirill Pushkin,
Aaron Sander,
Scott Stephenson,
Yuhan Wang,
Wolfgang Lorenzon
Abstract:
Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner…
▽ More
Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner detector walls without significant loss in reflectance to reduce dead volumes around active noble liquids, outgassing, and potential backgrounds. We report on the experimental results to measure the dependence of the reflectance on thickness of two PTFE samples at wavelengths near 178 nm. No change in reflectance was observed as the thickness of a cylindrically shaped PTFE vessel immersed in liquid xenon was varied between 1 mm and 9.5 mm.
△ Less
Submitted 27 March, 2017; v1 submitted 4 August, 2016;
originally announced August 2016.
-
Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
Authors:
PandaX-II Collaboration,
:,
Andi Tan,
Mengjiao Xiao,
Xiangyi Cui,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Haowei Gong,
Shouyang Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Xiaomei Li,
Xinglong Li,
Hao Liang,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Wolfgang Lorenzon
, et al. (29 additional authors not shown)
Abstract:
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit…
▽ More
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.
△ Less
Submitted 22 August, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Dark Matter Search Results from the Commissioning Run of PandaX-II
Authors:
PandaX Collaboration,
Andi Tan,
Xiang Xiao,
Xiangyi Cui,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Haowei Gong,
Shouyang Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Xiaomei Li,
Xinglong Li,
Hao Liang,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Wolfgang Lorenzon,
Yugang Ma
, et al. (29 additional authors not shown)
Abstract:
We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independ…
▽ More
We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.
△ Less
Submitted 5 June, 2016; v1 submitted 21 February, 2016;
originally announced February 2016.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
MiX: A Position Sensitive Dual-Phase Liquid Xenon Detector
Authors:
S. Stephenson,
J. Haefner,
Q. Lin,
K. Ni,
K. Pushkin,
R. Raymond,
M. Schubnell,
N. Shutty,
G. Tarlé,
C. Weaverdyck,
W. Lorenzon
Abstract:
The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of particle interactions in liquid xenon across a large energy range in an effort to probe aspects of radiation detection in liquid xenon. We report the design and per…
▽ More
The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of particle interactions in liquid xenon across a large energy range in an effort to probe aspects of radiation detection in liquid xenon. We report the design and performance of a small 3D position sensitive dual-phase liquid xenon time projection chamber with high light yield ($L_y^{122}=15.2 $pe/keV at zero field), long electron lifetime ($τ> 200 μ$s), and excellent energy resolution ($σ/E = 1\%$ for 1,333 keV gamma rays in a drift field of 200 V/cm). Liquid xenon time projection chambers with such high energy resolution may find applications not only in dark matter direct detection searches, but also in neutrinoless double beta decay experiments and other applications.
△ Less
Submitted 26 October, 2015; v1 submitted 5 July, 2015;
originally announced July 2015.
-
Low-mass dark matter search results from full exposure of PandaX-I experiment
Authors:
PandaX Collaboration,
Xiang Xiao,
Xun Chen,
Andi Tan,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl L. Giboni,
Haowei Gong,
Guodong Guo,
Ming He,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Xiang Liu,
Wolfgang Lorenzon,
Yugang Ma,
Yajun Mao,
Kaixuan Ni,
Kirill Pushkin
, et al. (21 additional authors not shown)
Abstract:
We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass o…
▽ More
We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.
△ Less
Submitted 20 August, 2015; v1 submitted 4 May, 2015;
originally announced May 2015.
-
First dark matter search results from the PandaX-I experiment
Authors:
PandaX Collaboration,
Mengjiao Xiao,
Xiang Xiao,
Li Zhao,
Xiguang Cao,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl L. Giboni,
Haowei Gong,
Guodong Guo,
Jie Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Xiang Liu,
Wolfgang Lorenzon,
Yugang Ma
, et al. (22 additional authors not shown)
Abstract:
We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positi…
▽ More
We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.
△ Less
Submitted 4 September, 2014; v1 submitted 21 August, 2014;
originally announced August 2014.
-
PandaX: A Liquid Xenon Dark Matter Experiment at CJPL
Authors:
X. G. Cao,
X. Chen,
Y. H. Chen,
X. Y. Cui,
D. Q. Fang,
C. B. Fu,
K. L. Giboni,
H. W. Gong,
G. D. Guo,
M. He,
J. Hu,
X. T. Huang,
X. D. Ji,
Y. L. Ju,
S. L. Li,
Q. Lin,
H. X. Liu,
J. L. Liu,
X. Liu,
W. Lorenzon,
Y. G. Ma,
Y. J. Mao,
K. X. Ni,
K. Pushkin,
X. X. Ren
, et al. (25 additional authors not shown)
Abstract:
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time proj…
▽ More
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.
△ Less
Submitted 12 May, 2014;
originally announced May 2014.
-
High Resolution Gamma Ray Detection in a Dual Phase Xenon Time Projection Chamber
Authors:
Qing Lin,
Yuehuan Wei,
Jie Bao,
Jie Hu,
Xinran Li,
Wolfgang Lorenzon,
Kaixuan Ni,
Michael Schubnell,
Mengjiao Xiao,
Xiang Xiao
Abstract:
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The position resolution is 2 mm in the center of detector, limited by the hole size of the mesh at the proportional scintillation region. An energy resolution of 1.6%…
▽ More
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The position resolution is 2 mm in the center of detector, limited by the hole size of the mesh at the proportional scintillation region. An energy resolution of 1.6%(σ /E) for 662 keV gamma rays is achieved by combining the ionization and scintillation signals at a drift field of 0.5 kV/cm. This represents the best energy resolution achieved among liquid xenon detectors. The energy resolution is only slightly dependent on drift field. Better than 2% energy resolution (σ /E) for 662 keV gamma rays can be achieved for drift fields between 100 V/cm and 2 kV/cm. With high position and energy resolutions, a dual phase XeTPC has also potential applications in surveys for neutrinoless double-beta decay and in gamma ray imaging.
△ Less
Submitted 3 December, 2013; v1 submitted 22 September, 2013;
originally announced September 2013.
-
One 4-Twist Helix Snake to Maintain Polarization in 8-120 GeV Proton Rings
Authors:
F. Antoulinakis,
E. A. Ljungman,
A. Tai,
C. A. Aidala,
E. D. Courant,
A. D. Krisch,
W. Lorenzon,
P. D. Myers,
R. S. Raymond,
D. W. Sivers,
M. A. Leonova,
Y. S. Derbenev,
V. S. Morozov,
A. M. Kondratenko
Abstract:
Solenoid Siberian snakes have successfully maintained polarization in particle rings below 1 GeV, but never in multi-GeV rings because the Lorentz contraction of a solenoid's integral B dl would require impractically long high-field solenoids. High energy rings, such as Brookhaven's 255 GeV Relativistic Heavy Ion Collider (RHIC), use only odd multiples of pairs of transverse B-field Siberian snake…
▽ More
Solenoid Siberian snakes have successfully maintained polarization in particle rings below 1 GeV, but never in multi-GeV rings because the Lorentz contraction of a solenoid's integral B dl would require impractically long high-field solenoids. High energy rings, such as Brookhaven's 255 GeV Relativistic Heavy Ion Collider (RHIC), use only odd multiples of pairs of transverse B-field Siberian snakes directly opposite each other. When it became impractical to use a pair of Siberian Snakes in Fermilab's 120 GeV Main Injector, we searched for a new type of single Siberian snake, which should overcome all depolarizing resonances in the 8.9 - 120 GeV range. We found that one snake made of one 4-twist helix and 2 short dipoles could maintain the polarization. This snake design might also be used at other rings, such as Japan's 30 GeV J-PARC, the 12 - 24 GeV NICA proton-deuteron collider at JINR-Dubna, and perhaps RHIC's injector, the 25 GeV AGS.
△ Less
Submitted 4 September, 2013;
originally announced September 2013.
-
Project X: Physics Opportunities
Authors:
Andreas S. Kronfeld,
Robert S. Tschirhart,
Usama Al-Binni,
Wolfgang Altmannshofer,
Charles Ankenbrandt,
Kaladi Babu,
Sunanda Banerjee,
Matthew Bass,
Brian Batell,
David V. Baxter,
Zurab Berezhiani,
Marc Bergevin,
Robert Bernstein,
Sudeb Bhattacharya,
Mary Bishai,
Thomas Blum,
S. Alex Bogacz,
Stephen J. Brice,
Joachim Brod,
Alan Bross,
Michael Buchoff,
Thomas W. Burgess,
Marcela Carena,
Luis A. Castellanos,
Subhasis Chattopadhyay
, et al. (111 additional authors not shown)
Abstract:
Part 2 of "Project X: Accelerator Reference Design, Physics Opportunities, Broader Impacts". In this Part, we outline the particle-physics program that can be achieved with Project X, a staged superconducting linac for intensity-frontier particle physics. Topics include neutrino physics, kaon physics, muon physics, electric dipole moments, neutron-antineutron oscillations, new light particles, had…
▽ More
Part 2 of "Project X: Accelerator Reference Design, Physics Opportunities, Broader Impacts". In this Part, we outline the particle-physics program that can be achieved with Project X, a staged superconducting linac for intensity-frontier particle physics. Topics include neutrino physics, kaon physics, muon physics, electric dipole moments, neutron-antineutron oscillations, new light particles, hadron structure, hadron spectroscopy, and lattice-QCD calculations. Part 1 is available as arXiv:1306.5022 [physics.acc-ph] and Part 3 is available as arXiv:1306.5024 [physics.acc-ph].
△ Less
Submitted 1 October, 2016; v1 submitted 20 June, 2013;
originally announced June 2013.
-
Updated Report Acceleration of Polarized Protons to 120-150 GeV/c at Fermilab
Authors:
E. D. Courant,
A. D. Krisch,
M. A. Leonova,
A. M. T. Lin,
J. Liu,
W. Lorenzon,
D. A. Nees,
R. S. Raymond,
D. W. Sivers,
V. K. Wong,
I. Kourbanis,
Ya. S. Derbenev,
V. S. Morozov,
D. G. Crabb,
P. E. Reimer,
J. R. O'Fallon,
G. Fidecaro,
M. Fidecaro,
F. Hinterberger,
S. M. Troshin,
M. N. Ukhanov,
A. M. Kondratenko,
W. T. H. van Oers
Abstract:
The SPIN@FERMI collaboration has updated its 1991-95 Reports on the acceleration of polarized protons in Fermilab's Main Injector, which was commissioned by Fermilab. This Updated Report summarizes some updated Physics Goals for a 120-150 GeV/c polarized proton beam. It also contains an updated discussion of the Modifications and Hardware needed for a polarized beam in the Main Injector, along wit…
▽ More
The SPIN@FERMI collaboration has updated its 1991-95 Reports on the acceleration of polarized protons in Fermilab's Main Injector, which was commissioned by Fermilab. This Updated Report summarizes some updated Physics Goals for a 120-150 GeV/c polarized proton beam. It also contains an updated discussion of the Modifications and Hardware needed for a polarized beam in the Main Injector, along with an updated Schedule and Budget.
△ Less
Submitted 12 October, 2011;
originally announced October 2011.
-
Beam Polarization at the ILC: the Physics Impact and the Accelerator Solutions
Authors:
B. Aurand,
I. Bailey,
C. Bartels,
A. Brachmann,
J. Clarke,
A. Hartin,
J. Hauptman,
C. Helebrant,
S. Hesselbach,
D. Kafer,
J. List,
W. Lorenzon,
I. Marchesini,
K. Monig,
K. C. Moffeit,
G. Moortgat-Pick,
S. Riemann,
A. Schalicke,
P. Schuler,
P. Starovoitov,
A. Ushakov,
U. Velte,
J. Wittschen,
M. Woods
Abstract:
In this contribution accelerator solutions for polarized beams and their impact on physics measurements are discussed. Focus are physics requirements for precision polarimetry near the interaction point and their realization with polarized sources. Based on the ILC baseline programme as described in the Reference Design Report (RDR), recent developments are discussed and evaluated taking into ac…
▽ More
In this contribution accelerator solutions for polarized beams and their impact on physics measurements are discussed. Focus are physics requirements for precision polarimetry near the interaction point and their realization with polarized sources. Based on the ILC baseline programme as described in the Reference Design Report (RDR), recent developments are discussed and evaluated taking into account physics runs at beam energies between 100 GeV and 250 GeV, as well as calibration runs on the Z-pole and options as the 1TeV upgrade and GigaZ.
△ Less
Submitted 17 March, 2009;
originally announced March 2009.
-
The Longitudinal Polarimeter at HERA
Authors:
M. Beckmann,
A. Borissov,
S. Brauksiepe,
F. Burkart,
H. Fischer,
J. Franz,
F. H. Heinsius,
K. Konigsmann,
W. Lorenzon,
F. M. Menden,
A. Most,
S. Rudnitsky,
C. Schill,
J. Seibert,
A. Simon
Abstract:
The design, construction and operation of a Compton back-scattering laser polarimeter at the HERA storage ring at DESY are described. The device measures the longitudinal polarization of the electron beam between the spin rotators at the HERMES experiment with a fractional systematic uncertainty of 1.6%. A measurement of the beam polarization to an absolute statistical precision of 0.01 requires…
▽ More
The design, construction and operation of a Compton back-scattering laser polarimeter at the HERA storage ring at DESY are described. The device measures the longitudinal polarization of the electron beam between the spin rotators at the HERMES experiment with a fractional systematic uncertainty of 1.6%. A measurement of the beam polarization to an absolute statistical precision of 0.01 requires typically one minute when the device is operated in the multi-photon mode. The polarimeter also measures the polarization of each individual electron bunch to an absolute statistical precision of 0.06 in approximately five minutes. It was found that colliding and non-colliding bunches can have substantially different polarizations. This information is important to the collider experiments H1 and ZEUS for their future longitudinally polarized electron program because those experiments use the colliding bunches only.
△ Less
Submitted 13 September, 2000;
originally announced September 2000.