Spin-Energy Entanglement of a Time-Focused Neutron
Authors:
J. C. Leiner,
S. J. Kuhn,
S. McKay,
J. K. Jochum,
F. Li,
A. A. M. Irfan,
F. Funama,
D. Mettus,
L. Beddrich,
C. Franz,
J. Shen,
S. R. Parnell,
R. M. Dalgliesh,
M. Loyd,
N. Geerits,
G. Ortiz,
C. Pfleiderer,
R. Pynn
Abstract:
Intra-particle entanglement of individual particles such as neutrons could enable a new class of scattering probes that are sensitive to entanglement in quantum systems and materials. In this work, we present experimental results demonstrating quantum contextuality as a result of entanglement between the spin and energy modes (i.e., degrees of freedom) of single neutrons in a beam using a pair of…
▽ More
Intra-particle entanglement of individual particles such as neutrons could enable a new class of scattering probes that are sensitive to entanglement in quantum systems and materials. In this work, we present experimental results demonstrating quantum contextuality as a result of entanglement between the spin and energy modes (i.e., degrees of freedom) of single neutrons in a beam using a pair of resonant radio-frequency neutron spin flippers in the MIEZE configuration (Modulated IntEnsity with Zero Effort). We verified the mode-entanglement by measuring a Clauser-Horne-Shimony-Holt (CHSH) contextuality witness $S$ defined in the spin and energy subsystems, observing a clear breach of the classical bound of $|S| \leq 2$, obtaining $S = 2.40 \pm 0.02$. These entangled beams could enable novel approaches for directly probing dynamics and entanglement in quantum materials whose low-energy excitation scales match those of the incident entangled neutron.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
Comparison of time-of-flight with MIEZE spectroscopy of H$_2$O: Necessity to go beyond the spin-echo approximation
Authors:
L. Beddrich,
P. Bender,
L. Spitz,
A. Wendl,
C. Franz,
S. Busch,
C. Pfleiderer,
O. Soltwedel,
J. K. Jochum
Abstract:
Here, we discuss the comparability of data acquisitioned with the Modulation of IntEnsity with Zero Effort data, a neutron spin-echo (NSE) technique to neutron Time-of-Flight (ToF) spectroscopy data. As a NSE technique MIEZE records the intermediate scattering function $\mathcal{I}(Q, τ)$ making it necessary to perform a Fourier transform to directly compare it to $S(Q, E)$, measured by ToF spectr…
▽ More
Here, we discuss the comparability of data acquisitioned with the Modulation of IntEnsity with Zero Effort data, a neutron spin-echo (NSE) technique to neutron Time-of-Flight (ToF) spectroscopy data. As a NSE technique MIEZE records the intermediate scattering function $\mathcal{I}(Q, τ)$ making it necessary to perform a Fourier transform to directly compare it to $S(Q, E)$, measured by ToF spectroscopy. Transforming either data set into the complementary parameter space requires detailed knowledge of detector efficiency, instrumental resolution, and background. We discuss these aspects by comparing measurements on pure water performed on the spectrometers RESEDA and TOFTOF under the same experimental conditions. Additionally, we discuss the data evaluation of spin-echo data beyond the SE approximation, which limits these techniques to small energy transfers.
△ Less
Submitted 11 December, 2023;
originally announced December 2023.
-
Optimization strategies and artefacts of time-involved small angle neutron scattering experiments
Authors:
Denis Mettus,
Alfonso Chacon,
Andreas Bauer,
Sebastian Mühlbauer,
Christian Pfleiderer
Abstract:
Kinetic small-angle neutron scattering provides access to the microscopic properties of mesoscale systems under slow, periodic perturbations. By interlocking the phases of neutron pulse, sample modulation, and detector signal, so-called Time-Involved Small Angle Neutron scattering Experiments (TISANE) allow to exploit the neutron velocity spread and record data without major sacrifice in intensity…
▽ More
Kinetic small-angle neutron scattering provides access to the microscopic properties of mesoscale systems under slow, periodic perturbations. By interlocking the phases of neutron pulse, sample modulation, and detector signal, so-called Time-Involved Small Angle Neutron scattering Experiments (TISANE) allow to exploit the neutron velocity spread and record data without major sacrifice in intensity at time-scales down to micro-seconds. We review the optimization strategies of TISANE that arise from specific aspects of the process of data acquisition and data analysis starting from the basic principles of operation. Typical artefacts of data recorded in TISANE due to the choice of time-binning and neutron chopper pulse width are illustrated by virtue of the response of the skyrmion lattice in MnSi under periodic changes of the direction of the magnetic field stabilizing the skyrmion lattice.
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
MIASANS at the longitudinal neutron resonant spin-echo spectrometer RESEDA
Authors:
J. C. Leiner,
C. Franz,
J. K. Jochum,
C. Pfleiderer
Abstract:
The RESEDA (Resonant Spin-Echo for Diverse Applications) instrument has been optimized for neutron scattering measurements of quasi-elastic and inelastic processes over a wide parameter range. One spectrometer arm of RESEDA is configured for the MIEZE (Modulation of Intensity with Zero Effort) technique, where the measured signal is an oscillation in neutron intensity over time prepared by two pre…
▽ More
The RESEDA (Resonant Spin-Echo for Diverse Applications) instrument has been optimized for neutron scattering measurements of quasi-elastic and inelastic processes over a wide parameter range. One spectrometer arm of RESEDA is configured for the MIEZE (Modulation of Intensity with Zero Effort) technique, where the measured signal is an oscillation in neutron intensity over time prepared by two precisely tuned radio-frequency (RF) flippers. With MIEZE, all spin-manipulations are performed before the beam reaches the sample, and thus the signal from sample scattering is not disrupted by any depolarizing conditions there (i.e. magnetic materials and fields). The MIEZE spectrometer is being further optimized for the requirements of small angle neutron scattering (MIASANS), a versatile combination of the spatial and dynamical resolving power of both techniques. We present the current status of (i) the newly installed superconducting solenoids as part of the RF flippers to significantly extend the dynamic range (ii) the development and installation of a new detector on a translation stage within a new larger SANS-type vacuum vessel for flexibility with angular coverage and resolution, and (iii) the efforts to reduce background.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
Small-angle neutron scattering of long-wavelength magnetic modulations in reduced sample dimensions
Authors:
Grace L. Causer,
Alfonso Chacon,
André Heinemann,
Christian Pfleiderer
Abstract:
Magnetic small-angle neutron scattering (SANS) is ideally suited to provide direct, reciprocal-space information of long-wavelength magnetic modulations, such as helicoids, solitons, merons, or skyrmions. SANS of such structures in thin films or micro-structured bulk materials is strongly limited by the tiny scattering volume vis a vis the prohibitively large background scattering by the substrate…
▽ More
Magnetic small-angle neutron scattering (SANS) is ideally suited to provide direct, reciprocal-space information of long-wavelength magnetic modulations, such as helicoids, solitons, merons, or skyrmions. SANS of such structures in thin films or micro-structured bulk materials is strongly limited by the tiny scattering volume vis a vis the prohibitively large background scattering by the substrate and support structures. Considering near-surface scattering closely above the critical angle of reflection, where unwanted signal contributions due to substrate or support structures becomes very small, we establish equivalent scattering patterns of the helical, conical, skyrmion lattice, and fluctuation-disordered phases in a polished bulk sample of MnSi between conventional transmission and near-surface SANS geometries. This motivates the prediction of a complete repository of scattering patterns expected for thin films in the near-surface SANS geometry for each orientation of the magnetic order with respect to the scattering plane.
△ Less
Submitted 11 November, 2022;
originally announced November 2022.
-
Extending MIEZE spectroscopy towards thermal wavelengths
Authors:
Johanna K. Jochum,
Christian Franz,
Thomas Keller,
Christian Pfleiderer
Abstract:
We propose a Modulation of intensity with zero effort (MIEZE) set-up for high-resolution neutron spectroscopy at momentum transfers up to 3Å$^{-1}$,energy transfers up to ~ 20 meV, and an energy resolution in the $μ$eV-range using both thermal and cold neutrons. MIEZE has two prominent advantages compared to classical neutron spin-echo. The first one is the possibility to investigate spin-depolari…
▽ More
We propose a Modulation of intensity with zero effort (MIEZE) set-up for high-resolution neutron spectroscopy at momentum transfers up to 3Å$^{-1}$,energy transfers up to ~ 20 meV, and an energy resolution in the $μ$eV-range using both thermal and cold neutrons. MIEZE has two prominent advantages compared to classical neutron spin-echo. The first one is the possibility to investigate spin-depolarizing samples or samples in strong magnetic fields without loss of signal amplitude and intensity. This allows for the study of spin fluctuations in ferromagnets, and facilitates the study of samples with strong spin-incoherent scattering. The second advantage is that multi-analyzer setups can be implemented with comparatively small effort. The use of thermal neutrons increases the range of validity of the spin-echo approximation towards shorter spin-echo times. In turn, the thermal MIEZE option for greater ranges (TIGER) closes the gap between classical neutron spin-echo spectroscopy and conventional high-resolution neutron spectroscopy techniques such as triple-axis, time-of-flight, and back-scattering. To illustrate the feasibility of TIGER we present the details of an implementation at the beamline RESEDA at FRM II by means of an additional velocity selector, polarizer and analyzer.
△ Less
Submitted 18 November, 2022; v1 submitted 19 July, 2022;
originally announced July 2022.
-
Optically excited spin dynamics of thermally metastable skyrmions in Fe$_{0.75}$Co$_{0.25}$Si
Authors:
Jantje Kalin,
Sibylle Sievers,
Heiko Füser,
Hans Werner Schumacher,
Felipe García-Sánchez,
Andreas Bauer,
Christian Pfleiderer,
Mark Bieler
Abstract:
We investigate the microwave spin excitations of the cubic chiral magnet Fe$_{0.75}$Co$_{0.25}$Si as driven by the thermal modulation of magnetic interactions via laser heating and probed by time-resolved measurements of the magneto-optical Kerr effect. Focusing on the topologically nontrivial skyrmion lattice state, the dynamic properties in thermodynamic equilibrium are compared with those of a…
▽ More
We investigate the microwave spin excitations of the cubic chiral magnet Fe$_{0.75}$Co$_{0.25}$Si as driven by the thermal modulation of magnetic interactions via laser heating and probed by time-resolved measurements of the magneto-optical Kerr effect. Focusing on the topologically nontrivial skyrmion lattice state, the dynamic properties in thermodynamic equilibrium are compared with those of a metastable state prepared by means of rapid field cooling. In both cases, we find precessional and exponential contributions to the dynamic response, characteristic of a breathing mode and energy dissipation, respectively. When taking into account the universal scaling as a function of temperature, the precession frequencies in the equilibrium and metastable skyrmion state are in excellent quantitative agreement. This finding highlights that skyrmion states far from thermal equilibrium promise great flexibility, for instance with respect to temperature and field scales, both for possible microwave applications and the study of fundamental properties.
△ Less
Submitted 29 June, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
MIEZE Neutron Spin-Echo Spectroscopy of Strongly Correlated Electron Systems
Authors:
Christian Franz,
Steffen Säubert,
Andreas Wendl,
Franz X. Haslbeck,
Olaf Soltwedel,
Johanna K. Jochum,
Leonie Spitz,
Jonas Kindervater,
Andreas Bauer,
Peter Böni,
Christian Pfleiderer
Abstract:
Recent progress in neutron spin-echo spectroscopy by means of longitudinal Modulation of IntEnsity with Zero Effort (MIEZE) is reviewed. Key technical characteristics are summarized which highlight that the parameter range accessible in momentum and energy, as well as its limitations, are extremely well understood and controlled. Typical experimental data comprising quasi-elastic and inelastic sca…
▽ More
Recent progress in neutron spin-echo spectroscopy by means of longitudinal Modulation of IntEnsity with Zero Effort (MIEZE) is reviewed. Key technical characteristics are summarized which highlight that the parameter range accessible in momentum and energy, as well as its limitations, are extremely well understood and controlled. Typical experimental data comprising quasi-elastic and inelastic scattering are presented, featuring magneto-elastic coupling and crystal field excitations in Ho2Ti2O7, the skyrmion lattice to paramagnetic transition under applied magnetic field in MnSi, ferromagnetic criticality and spin waves in Fe. In addition bench marking studies of the molecular dynamics in H2O are reported. Taken together, the advantages of MIEZE spectroscopy in studies at small and intermediate momentum transfers comprise an exceptionally wide dynamic range of over seven orders of magnitude, the capability to perform straight forward studies on depolarizing samples or under depolarizing sample environments, as well as on incoherently scattering materials.
△ Less
Submitted 3 April, 2021;
originally announced April 2021.
-
The longitudinal neutron resonant spin echo spectrometer RESEDA
Authors:
Christian Franz,
Olaf Soltwedel,
Christian Fuchs,
Steffen Säubert,
Franz Haslbeck,
Andreas Wendl,
Johanna K. Jochum,
Peter Böni,
Christian Pfleiderer
Abstract:
The instrumental layout and technical realisation of the neutron resonant spin echo (NRSE) spectrometer RESEDA at the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching, Germany, is presented. RESEDA is based on a longitudinal field configuration, boosting both dynamic range and maximum resolution of the spectrometer compared to the conventional transverse layout. The resonant neutron spin echo techni…
▽ More
The instrumental layout and technical realisation of the neutron resonant spin echo (NRSE) spectrometer RESEDA at the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching, Germany, is presented. RESEDA is based on a longitudinal field configuration, boosting both dynamic range and maximum resolution of the spectrometer compared to the conventional transverse layout. The resonant neutron spin echo technique enables the realisation of two complementary implementations: A longitudinal NRSE (LNRSE) option comparable to the classical neutron spin echo (NSE) method for highest energy resolution and large momentum transfers as well as a Modulation of Intensity with Zero Effort (MIEZE) option for depolarising samples or sample environments such as high magnetic fields, and strong incoherent scattering samples. With their outstanding dynamic range, exceeding nominally seven orders of magnitude, both options cover new fields for ultra-high resolution neutron spectroscopy in hard and soft condensed matter systems. In this paper the concept of RESEDA as well as the technical realisation along with reference measurements are reported.
△ Less
Submitted 23 March, 2021;
originally announced March 2021.
-
Optimized signal deduction procedure for the MIEZE spectroscopy technique
Authors:
J. K. Jochum,
L. Spitz,
C. Franz,
A. Wendl,
J. C. Leiner,
C. Pfleiderer,
O. Soltwedel
Abstract:
We report a method to determine the phase and amplitude of sinusoidally modulated event rates, binned into four bins per oscillation, based on data generated at the resonant neutron spin-echo spectrometer RESEDA. The presented algorithm relies on a reconstruction of the unknown parameters. It omits a calculation intensive fitting procedure and avoids contrast reduction due to averaging effects. It…
▽ More
We report a method to determine the phase and amplitude of sinusoidally modulated event rates, binned into four bins per oscillation, based on data generated at the resonant neutron spin-echo spectrometer RESEDA. The presented algorithm relies on a reconstruction of the unknown parameters. It omits a calculation intensive fitting procedure and avoids contrast reduction due to averaging effects. It allows the current data acquisition bottleneck at RESEDA to be relaxed by a factor of four and thus increases the potential time resolution of the detector by the same factor. We explain the approach in detail and compare it to the established fitting procedures of time series having four and 16 time bins per oscillation. In addition we present the empirical estimates of the errors of the three methods and compare them to each other. We show that the reconstruction is unbiased, asymptotic, and efficient for estimating the phase. Reconstructing the contrast increases the error bars by roughly 10% as compared to fitting 16 time binned oscillations. Finally, we give heuristic, analytical equations to estimate the error for phase and contrast as a function of their initial values and counting statistics.
△ Less
Submitted 19 July, 2022; v1 submitted 11 March, 2021;
originally announced March 2021.
-
Oscillatory magnetic fields for neutron resonance spin-echo spectroscopy
Authors:
J. K. Jochum,
A. Hecht,
O. Soltwedel,
C. Fuchs,
J. Frank,
E. Faulhaber,
J. C. Leiner,
C. Pfleiderer,
C. Franz
Abstract:
The generation of high frequency oscillatory magnetic fields represents a fundamental component underlying the successful implementation of neutron resonant spin-echo spectrometers, a class of instrumentation critical for the high-resolution extraction of dynamical excitations (structural and magnetic) in materials. In this paper, the setup of the resonant circuits at the longitudinal resonant spi…
▽ More
The generation of high frequency oscillatory magnetic fields represents a fundamental component underlying the successful implementation of neutron resonant spin-echo spectrometers, a class of instrumentation critical for the high-resolution extraction of dynamical excitations (structural and magnetic) in materials. In this paper, the setup of the resonant circuits at the longitudinal resonant spin-echo spectrometer RESEDA is described in comprehensive technical detail. We demonstrate that these circuits are capable of functioning at frequencies up to 3.6 MHz and over a broad bandwidth down to 35 kHz using a combination of signal generators, amplifiers, impedance matching transformers, and a carefully designed cascade of tunable capacitors and customized coils.
△ Less
Submitted 27 November, 2020; v1 submitted 8 October, 2020;
originally announced October 2020.
-
The multi-purpose three-axis spectrometer (TAS) MIRA at FRM II
Authors:
R. Georgii,
T. Weber,
M. Skoulatos,
M. Janoschek,
S. Mühlbauer,
C. Pfleiderer,
P. Böni
Abstract:
The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another a…
▽ More
The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another advantage of MIRA is the modular assembly allowing for instrumental adaption to the needs of the experiment within a few hours. The development of new methods such as the spin-echo technique MIEZE is another important application at MIRA. Scientific topics include the investigation of complex inter-metallic alloys and spectroscopy on incommensurate magnetic structures.
△ Less
Submitted 2 October, 2017;
originally announced October 2017.
-
RESPECT: Neutron Resonance Spin-Echo Spectrometer for Extreme Studies
Authors:
Robert Georgii,
Jonas Kindervater,
Christian Pfleiderer,
Peter Böni
Abstract:
We propose the design of a Resonance SPin-echo spECtrometer for exTreme studies, RESPECT, that is ideally suited for the exploration of non-dispersive processes such as diffusion, crystallization, slow dynamics, tunneling processes, crystal electric field excitations, and spin fluctuations. It is a variant of the conventional neutron spin-echo technique (NSE) by i) replacing the long precession co…
▽ More
We propose the design of a Resonance SPin-echo spECtrometer for exTreme studies, RESPECT, that is ideally suited for the exploration of non-dispersive processes such as diffusion, crystallization, slow dynamics, tunneling processes, crystal electric field excitations, and spin fluctuations. It is a variant of the conventional neutron spin-echo technique (NSE) by i) replacing the long precession coils by pairs of longitudinal neutron spin-echo coils combined with RF-spin flippers and ii) by stabilizing the neutron polarization with small longitudinal guide fields that can in addition be used as field subtraction coils thus allowing to adjust the field integrals over a range of 8 orders of magnitude. Therefore, the dynamic range of RESPECT can in principle be varied over 8 orders of magnitude in time, if neutrons with the required energy are made available. Similarly as for existing NSE-spectrometers, spin echo times of up to approximately 1 microsecond can be reached if the divergence and the correction elements are properly adjusted. Thanks to the optional use of neutron guides and the fact that the currents for the correction coils are much smaller than in standard NSE, intensity gains of at least one order of magnitude are expected , making the concept of RESPECT also competitive for operation at medium flux neutron sources. RESPECT can also be operated in a MIEZE configuration allowing the investigation of relaxation processes in depolarizing environments as they occur when magnetic fields are applied at the sample position, i.e. for the investigation of the dynamics of flux lines in superconductors, magnetic fluctuations in ferromagnetic materials, and samples containing hydrogen.
△ Less
Submitted 2 August, 2016;
originally announced August 2016.
-
Ultra-high vacuum compatible induction-heated rod casting furnace
Authors:
Andreas Bauer,
Andreas Neubauer,
Wolfgang Münzer,
Alexander Regnat,
Georg Benka,
Martin Meven,
Björn Pedersen,
Christian Pfleiderer
Abstract:
We report the design of a radio-frequency induction-heated rod casting furnace that permits the preparation of polycrystalline ingots of intermetallic compounds under ultra-high vacuum compatible conditions. The central part of the system is a bespoke water-cooled Hukin crucible supporting a casting mold. Depending on the choice of mold, typical rods have a diameter between 6 mm and 10 mm and a le…
▽ More
We report the design of a radio-frequency induction-heated rod casting furnace that permits the preparation of polycrystalline ingots of intermetallic compounds under ultra-high vacuum compatible conditions. The central part of the system is a bespoke water-cooled Hukin crucible supporting a casting mold. Depending on the choice of mold, typical rods have a diameter between 6 mm and 10 mm and a length up to 90 mm, suitable for single-crystal growth by means of float-zoning. The setup is all-metal sealed and may be baked out. We find that the resulting ultra-high vacuum represents an important precondition for processing compounds with high vapor pressures under a high-purity argon atmosphere up to 3 bar. Using the rod casting furnace, we succeeded to prepare large high-quality single crystals of two half-Heusler compounds, namely the itinerant antiferromagnet CuMnSb and the half-metallic ferromagnet NiMnSb.
△ Less
Submitted 1 July, 2016;
originally announced July 2016.
-
Versatile module for experiments with focussing neutron guides
Authors:
T. Adams,
G. Brandl,
A. Chacon,
J. N. Wagner,
M. Rahn,
S. Mühlbauer,
R. Georgii,
C. Pfleiderer,
P. Böni
Abstract:
We report the development of a versatile module that permits fast and reliable use of focussing neutron guides under varying scattering angles. A simple procedure for setting up the module and neutron guides is illustrated by typical intensity patterns to highlight operational aspects as well as typical parasitic artefacts. Combining a high-precision alignment table with separate housings for the…
▽ More
We report the development of a versatile module that permits fast and reliable use of focussing neutron guides under varying scattering angles. A simple procedure for setting up the module and neutron guides is illustrated by typical intensity patterns to highlight operational aspects as well as typical parasitic artefacts. Combining a high-precision alignment table with separate housings for the neutron guides on kinematic mounts, the change-over between neutron guides with different focussing characteristics requires no readjustments of the experimental set-up. Exploiting substantial gain factors, we demonstrate the performance of this versatile neutron scattering module in a study of the effects of uniaxial stress on the domain populations in the transverse spin density wave phase of single crystal Cr.
△ Less
Submitted 2 December, 2014;
originally announced December 2014.
-
Neutron spin echo spectroscopy under 17T magnetic field at RESEDA
Authors:
J. Kindervater,
N. Martin,
W. Häußler,
M. Krautloher,
C. Fuchs,
S. Mühlbauer,
J. A. Lim,
E. Blackburn,
P. Böni,
C. Pfleiderer
Abstract:
We report proof-of-principle measurements at the neutron resonance spin echo spectrometer RESEDA (MLZ) under large magnetic fields by means of Modulation of IntEnsity with Zero Effort (MIEZE). Our study demonstrates the feasibility of applying strong magnetic fields up to 17\,T at the sample while maintaining unchanged sub-$μ$eV resolution. We find that the MIEZE-spin-echo resolution curve remains…
▽ More
We report proof-of-principle measurements at the neutron resonance spin echo spectrometer RESEDA (MLZ) under large magnetic fields by means of Modulation of IntEnsity with Zero Effort (MIEZE). Our study demonstrates the feasibility of applying strong magnetic fields up to 17\,T at the sample while maintaining unchanged sub-$μ$eV resolution. We find that the MIEZE-spin-echo resolution curve remains essentially unchanged as a function of magnetic field up to the highest fields available, promising access to high fields without need for additional fine-tuning of the instrument. This sets the stage for the experimental investigation of subtle field dependent phenomena, such as magnetic field-driven phase transitions in hard and soft condensed matter physics.
△ Less
Submitted 2 June, 2014;
originally announced June 2014.
-
Optical floating zone growth of high-quality Cu2MnAl single crystals
Authors:
Andreas Neubauer,
Florian Jonietz,
Martin Meven,
Robert Georgii,
Georg Brandl,
Gunther Behr,
Peter Böni,
Christian Pfleiderer
Abstract:
We report the growth of large single-crystals of Cu2MnAl, a ferromagnetic Heusler compound suitable for polarizing neutron monochromators, by means of optical floating zone under ultra-high vacuum compatible conditions. Unlike Bridgman or Czochralsky grown Cu2MnAl, our floating zone grown single-crystals show highly reproducible magnetic properties and an excellent crystal quality with a narrow an…
▽ More
We report the growth of large single-crystals of Cu2MnAl, a ferromagnetic Heusler compound suitable for polarizing neutron monochromators, by means of optical floating zone under ultra-high vacuum compatible conditions. Unlike Bridgman or Czochralsky grown Cu2MnAl, our floating zone grown single-crystals show highly reproducible magnetic properties and an excellent crystal quality with a narrow and homogeneous mosaic spread as examined by neutron diffraction. An investigation of the polarizing properties in neutron scattering suggests a high polarization efficiency, limited by the relatively small sample dimensions studied. Our study identifies optical floating zone under ultra-high vacuum compatible conditions as a highly reproducible method to grow high-quality single-crystals of Cu2MnAl.
△ Less
Submitted 11 July, 2012;
originally announced July 2012.
-
Turn-key module for neutron scattering with sub-micro-eV resolution
Authors:
Robert Georgii,
Georg Brandl,
Nikolas Arend,
Wolfgang Häußler,
Alexander Tischendorf,
Christian Pfleiderer,
Peter Böni,
Jyotsana Lal
Abstract:
We report the development of a compact turn-key module that boosts the resolution in quasi-elastic neutron scattering by several orders of magnitude down to the low sub-micro-eV range. It is based on a pair of neutron resonance spin flippers that generate a well defined temporal intensity modulation, also known as MIEZE (Modulation of IntEnsity by Zero Effort). The module may be used under versati…
▽ More
We report the development of a compact turn-key module that boosts the resolution in quasi-elastic neutron scattering by several orders of magnitude down to the low sub-micro-eV range. It is based on a pair of neutron resonance spin flippers that generate a well defined temporal intensity modulation, also known as MIEZE (Modulation of IntEnsity by Zero Effort). The module may be used under versatile conditions, in particular in applied magnetic fields and for depolarising and incoherently scattering samples. We demonstrate the power of MIEZE in studies of the helimagnetic order in MnSi under applied magnetic fields.
△ Less
Submitted 21 February, 2011;
originally announced February 2011.