Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
Improving the Robustness of the Advanced LIGO Detectors to Earthquakes
Authors:
Eyal Schwartz,
A Pele,
J Warner,
B Lantz,
J Betzwieser,
K L Dooley,
S Biscans,
M Coughlin,
N Mukund,
R Abbott,
C Adams,
R X Adhikari,
A Ananyeva,
S Appert,
K Arai,
J S Areeda,
Y Asali,
S M Aston,
C Austin,
A M Baer,
M Ball,
S W Ballmer,
S Banagiri,
D Barker,
L Barsotti
, et al. (174 additional authors not shown)
Abstract:
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differenti…
▽ More
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differential motion of the interferometer arms with respect to one another, resulting in a reduction of DARM signal at frequencies below 100\,mHz. Our method greatly improved the interferometers' capability to remain operational during earthquakes, with ground velocities up to 3.9\,$μ\mbox{m/s}$ rms in the beam direction, setting a new record for both detectors. This sets a milestone in seismic controls of the Advanced LIGO detectors' ability to manage high ground motion induced by earthquakes, opening a path for further robust operation in other extreme environmental conditions.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Accretion-induced spin-wandering effects on the neutron star in Scorpius X-1: Implications for continuous gravitational wave searches
Authors:
Arunava Mukherjee,
Chris Messenger,
Keith Riles
Abstract:
The LIGO's discovery of binary black hole mergers has opened up a new era of transient gravitational wave astronomy. The potential detection of gravitational radiation from another class of astronomical objects, rapidly spinning non-axisymmetric neutron stars, would constitute a new area of gravitational wave astronomy. Scorpius X-1 (Sco X-1) is one of the most promising sources of continuous grav…
▽ More
The LIGO's discovery of binary black hole mergers has opened up a new era of transient gravitational wave astronomy. The potential detection of gravitational radiation from another class of astronomical objects, rapidly spinning non-axisymmetric neutron stars, would constitute a new area of gravitational wave astronomy. Scorpius X-1 (Sco X-1) is one of the most promising sources of continuous gravitational radiation to be detected with present-generation ground-based gravitational wave detectors, such as Advanced LIGO and Advanced Virgo. As the sensitivity of these detectors improve in the coming years, so will power of the search algorithms being used to find gravitational wave signals. Those searches will still require integation over nearly year long observational spans to detect the incredibly weak signals from rotating neutron stars. For low mass X-ray binaries such as Sco X-1 this difficult task is compounded by neutron star "spin wandering" caused by stochastic accretion fluctuations. In this paper, we analyze X-ray data from the RXTE satellite to infer the fluctuating torque on the neutron star in Sco X-1. We then perform a large-scale simulation to quantify the statistical properties of spin-wandering effects on the gravitational wave signal frequency and phase evolution. We find that there are a broad range of expected maximum levels of frequency wandering corresponding to maximum drifts of between 0.3-50 μHz/sec over a year at 99% confidence. These results can be cast in terms of the maximum allowed length of a coherent signal model neglecting spin-wandering effects as ranging between 5-80 days. This study is designed to guide the development and evaluation of Sco X-1 search algorithms.
△ Less
Submitted 17 October, 2017;
originally announced October 2017.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
High-precision Absolute Coordinate Measurement using Frequency Scanned Interferometry
Authors:
Tianxiang Chen,
Haijun Yang,
Keith Riles,
Cheng Li
Abstract:
In this paper, we report high-precision absolute position measurement performed with frequency scanned interferometry (FSI). We reported previously on measurement of absolute distance with FSI [1]. Absolute position is determined by several related absolute distances measured simultaneously. The achieved precision of 2-dimensional measurements is better than 1 micron, and in 3-dimensional measurem…
▽ More
In this paper, we report high-precision absolute position measurement performed with frequency scanned interferometry (FSI). We reported previously on measurement of absolute distance with FSI [1]. Absolute position is determined by several related absolute distances measured simultaneously. The achieved precision of 2-dimensional measurements is better than 1 micron, and in 3-dimensional measurements, the precision on X and Y is confirmed to be below 1 micron, while the confirmed precision on Z is about 2 microns, where the confirmation is limited by the lower precision of the moving stage in Z direction.
△ Less
Submitted 6 December, 2013; v1 submitted 26 March, 2013;
originally announced March 2013.
-
Frequency Scanned Interferometry for ILC Tracker Alignment
Authors:
Hai-Jun Yang,
Tianxiang Chen,
Keith Riles
Abstract:
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. High-finesse Fabry-Perot interferometers were used to determine frequency changes during scanning. A dual-laser scanning technique was used to cancel d…
▽ More
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. High-finesse Fabry-Perot interferometers were used to determine frequency changes during scanning. A dual-laser scanning technique was used to cancel drift errors to improve the absolute distance measurement precision. A new dual-channel FSI demonstration system is also presented which is an interim stage toward practical application of multi-channel distance measurement. Under realistic conditions, a precision of 0.3 microns was achieved for an absolute distance of 0.57 meters. A possible optical alignment system for a silicon tracker is also presented.
△ Less
Submitted 12 September, 2011;
originally announced September 2011.
-
Gravitational-wave Astronomy: Opening a New Window on the Universe for Students, Educators and the Public
Authors:
M. Cavaglia,
M. Hendry,
D. Ingram,
S. Milde,
D. Reitze,
K. Riles,
B. Schutz,
A. L. Stuver,
T. Summerscales,
J. Thacker,
C. V. Torres,
D. Ugolini,
M. Vallisneri,
A. Zermeno
Abstract:
The nascent field of gravitational-wave astronomy offers many opportunities for effective and inspirational astronomy outreach. Gravitational waves, the "ripples in space-time" predicted by Einstein's theory of General Relativity, are produced by some of the most energetic and dramatic phenomena in the cosmos, including black holes, neutron stars and supernovae. The detection of gravitational wa…
▽ More
The nascent field of gravitational-wave astronomy offers many opportunities for effective and inspirational astronomy outreach. Gravitational waves, the "ripples in space-time" predicted by Einstein's theory of General Relativity, are produced by some of the most energetic and dramatic phenomena in the cosmos, including black holes, neutron stars and supernovae. The detection of gravitational waves will help to address a number of fundamental questions in physics, from the evolution of stars and galaxies to the origin of dark energy and the nature of space-time itself. Moreover, the cutting-edge technology developed to search for gravitational waves is pushing back the frontiers of many fields, from lasers and materials science to high performance computing, and thus provides a powerful showcase for the attractions and challenges of a career in science and engineering. For several years a worldwide network of ground-based laser interferometric gravitational-wave detectors has been fully operational, including the two LIGO detectors in the United States. These detectors are already among the most sensitive scientific instruments on the planet and in the next few years their sensitivity will achieve further significant improvement. Those developments promise to open an exciting new window on the Universe, heralding the arrival of gravitational-wave astronomy as a revolutionary, new observational field. In this paper we describe the extensive program of public outreach activities already undertaken by the LIGO Scientific Collaboration, and a number of special events which we are planning for IYA2009.
△ Less
Submitted 23 June, 2008;
originally announced June 2008.
-
High-precision Absolute Distance Measurement using Dual-Laser Frequency Scanned Interferometry Under Realistic Conditions
Authors:
Hai-Jun Yang,
Keith Riles
Abstract:
In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry-Perot interferometers were used to determine frequency changes during…
▽ More
In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry-Perot interferometers were used to determine frequency changes during scanning. Dual lasers with oppositely scanning directions, combined with a multi-distance-measurement technique previously reported, were used to cancel drift errors and to suppress vibration effects and interference fringe uncertainties. Under realistic conditions, a precision about 0.2 microns was achieved for a distance of 0.41 meters.
△ Less
Submitted 21 September, 2006;
originally announced September 2006.
-
Impact of Tracker Design on Higgs and Slepton Measurements
Authors:
Hai-Jun Yang,
Keith Riles
Abstract:
We have studied the impact of charged track resolution on Higgs mass and production cross section measurement in the process $e^+e^- \to Z^0 H, Z^0 \to \ell^+\ell^-, H \to X$ for Higgs masses between 120 and 160 GeV, and on smuon mass measurement using smuon pair production for three different mass pairs, assuming the International Linear Collider(ILC) is operated at 500 GeV center of mass energ…
▽ More
We have studied the impact of charged track resolution on Higgs mass and production cross section measurement in the process $e^+e^- \to Z^0 H, Z^0 \to \ell^+\ell^-, H \to X$ for Higgs masses between 120 and 160 GeV, and on smuon mass measurement using smuon pair production for three different mass pairs, assuming the International Linear Collider(ILC) is operated at 500 GeV center of mass energies (CME) with integrated luminosities of 500 $fb^{-1}$. The effect of initial state radiation (ISR), beamstrahlung and beam energy spread on Higgs and smuon mass measurement are also estimated. Using fast Monte Carlo simulations of the 2001 North American baseline detector designs (LD and SD), we find that the ISR and beamstrahlung have significant impact on Higgs and smuon mass measurement; Charged track momentum resolution affect Higgs mass significantly with better track performance yielding better Higgs mass resolution and precision for the track momentum resolution improvement up to a factor of about 5; Track momentum resolution has little effect on the measurement precision of the Higgsstrahlung cross section, the branching ratio of $H \to C\bar{C}$, the smuon and neutralino masses; Beam energy spread better than about 0.2% has little effect on Higgs, smuon and neutralino masses; The SD detector provides a more accurate measurement than the LD of the Higgs mass.
△ Less
Submitted 27 June, 2005;
originally announced June 2005.
-
Frequency Scanned Interferometry for ILC Tracker Alignment
Authors:
Hai-Jun Yang,
Sven Nybery,
Keith Riles
Abstract:
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer was used to determine frequency changes during scanning. Two mul…
▽ More
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer was used to determine frequency changes during scanning. Two multiple-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, measurement precision of about 50 nm was achieved for absolute distances ranging from 0.1 meters to 0.7 meters by using the first multiple-distance-measurement technique. The second analysis technique has the capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with amplitude as small as a few nanometers, without a priori knowledge. A possible optical alignment system for a silicon tracker is also presented.
△ Less
Submitted 27 June, 2005;
originally announced June 2005.
-
High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry
Authors:
Hai-Jun Yang,
Jason Deibel,
Sven Nyberg,
Keith Riles
Abstract:
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Tw…
▽ More
In this paper, we report high-precision absolute distance and vibration measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multiple-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, measurement precision of $\sim$ 50 nm was achieved for absolute distances ranging from 0.1 meters to 0.7 meters by using the first multiple-distance-measurement technique. The second analysis technique has the capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with amplitude as small as a few nanometers, without a priori knowledge.
△ Less
Submitted 25 November, 2004; v1 submitted 21 September, 2004;
originally announced September 2004.