-
First observation of a nuclear $s$-state of $Ξ$ hypernucleus, $^{15}_Ξ{\rm C}$
Authors:
M. Yoshimoto,
J. K. Ahn,
B. Bassalleck,
H. Ekawa,
Y. Endo,
M. Fujita,
Y. Han,
T. Hashimoto,
S. H. Hayakawa,
K. Hicks,
K. Hoshino,
S. Hoshino,
S. H. Hwang,
Y. Ichikawa,
M. Ichikawa,
K. Imai,
Y. Ishikawa,
H. Kanauchi,
A. Kasagi,
S. H. Kim,
S. Kinbara,
P. M. Lin,
T. L. Ma,
K. Miwa,
A. T. Moe
, et al. (24 additional authors not shown)
Abstract:
Bound-systems of $Ξ^-$--$^{14}_{}{\rm N}$ are studied via $Ξ^-$ capture at rest followed by emission of a twin single-$Λ$ hypernucleus in the emulsion detectors. Two events forming extremely deep $Ξ^-$ bound states were obtained by analysis of a hybrid method in the E07 experiment at J-PARC and reanalysis of the E373 experiment at KEK-PS. The decay mode of one event was assigned as…
▽ More
Bound-systems of $Ξ^-$--$^{14}_{}{\rm N}$ are studied via $Ξ^-$ capture at rest followed by emission of a twin single-$Λ$ hypernucleus in the emulsion detectors. Two events forming extremely deep $Ξ^-$ bound states were obtained by analysis of a hybrid method in the E07 experiment at J-PARC and reanalysis of the E373 experiment at KEK-PS. The decay mode of one event was assigned as $Ξ^-+^{14}_{}{\rm N}\to^{5}_Λ{\rm He}$+$^{5}_Λ{\rm He}$+$^{4}_{}{\rm He}$+n. Since there are no excited states for daughter particles, the binding energy of the $Ξ^-$ hyperon, $B_{Ξ^-}$, in $^{14}_{}{\rm N}$ nucleus was uniquely determined to be 6.27 $\pm$ 0.27 MeV. Another $Ξ^-$--$^{14}_{}{\rm N}$ system via the decay $^{9}_Λ{\rm Be}$ + $^{5}_Λ{\rm He}$ + n brings a $B_{Ξ^-}$ value, 8.00 $\pm$ 0.77 MeV or 4.96 $\pm$ 0.77 MeV, where the two possible values of $B_{Ξ^-}$ correspond to the ground and the excited states of the daughter $^{9}_Λ{\rm Be}$ nucleus, respectively. Because the $B_{Ξ^-}$ values are larger than those of the previously reported events (KISO and IBUKI), which are both interpreted as the nuclear $1p$ state of the $Ξ^-$--$^{14}_{}{\rm N}$ system, these new events give the first indication of the nuclear $1s$ state of the $Ξ$ hypernucleus, $^{15}_Ξ{\rm C}$.
△ Less
Submitted 26 May, 2021; v1 submitted 15 March, 2021;
originally announced March 2021.
-
Data acquisition system in Run-0a for the J-PARC E16 experiment
Authors:
Tomonori Takahashi,
Kazuya Aoki,
Sakiko Ashikaga,
Wen-Chen Chang,
Eitaro Hamada,
Ryotaro Honda,
Masaya Ichikawa,
Masahiro Ikeno,
Shunsuke Kajikawa,
Koki Kanno,
Daisuke Kawama,
Takehito Kondo,
Che-Sheng Lin,
Chih-Hsun Lin,
Yuhei Morino,
Tomoki Murakami,
Wataru Nakai,
Satomi Nakasuga,
Megumi Naruki,
Yuki Obara,
Kyoichiro Ozawa,
Hiroyuki Sako,
Susumu Sato,
Hiroshi Sendai,
Kazuki Suzuki
, et al. (4 additional authors not shown)
Abstract:
J-PARC E16 is an experiment to examine the origin of hadron mass through a systematic measurement of spectral changes of vector mesons in nuclei. The measurement of $e^{+}e^{-}$ pairs from the decay of vector mesons will provide the information of the partial restoration of the chiral symmetry in a normal nuclear density. To resolve a pulse pile-up and achieve good discrimination of $e^{\pm}$ from…
▽ More
J-PARC E16 is an experiment to examine the origin of hadron mass through a systematic measurement of spectral changes of vector mesons in nuclei. The measurement of $e^{+}e^{-}$ pairs from the decay of vector mesons will provide the information of the partial restoration of the chiral symmetry in a normal nuclear density. To resolve a pulse pile-up and achieve good discrimination of $e^{\pm}$ from the background of a reaction rate of an order of 10 MHz, the data acquisition (DAQ) system uses waveform sampling chips of APV25 and DRS4. The trigger rate and data rate are expected to be 1 kHz and 130--330 MiB/s, respectively. The DAQ system for readout of APV25 and DRS4 were developed, where events were synchronized by common trigger and tag data. The first commissioning in beam, called Run-0a, was performed in June 2020 with about 1/4 of the designed setup. The DAQ worked with a trigger rate of 300 Hz in the Run-0a and the main bottleneck was a large data size of APV25. Further optimization of the DAQ system will improve the performance.
△ Less
Submitted 31 October, 2020;
originally announced November 2020.
-
Towards a novel laser-driven method of exotic nuclei extraction-acceleration for fundamental physics and technology
Authors:
Mamiko Nishiuchi,
Hironao Sakaki,
Katsuhisa Nishio,
Riccard Orlandi,
Hiroyuki Sako,
Tatiana. A. Pikuz,
Anatory Ya. Faenov,
Timur Zh. Esirkepov,
Alexander S. Pirozhkov,
Kenya Matsukawa,
Akito Sagisaka,
Koichi Ogura,
Masato Kanasaki,
Hiromitsu Kiriyama,
Yuji Fukuda,
Hiroyuki Koura,
Masaki Kando,
Tomoya Yamauchi,
Yukinobu Watanabe,
Sergei V. Bulanov,
Kiminori Kondo,
Kenichi Imai,
Shoji Nagamiya
Abstract:
The measurement of properties of exotic nuclei, essential for fundamental nuclear physics, now confronts a formidable challenge for contemporary radiofrequency accelerator technology. A promising option can be found in the combination of state-of-the-art high-intensity short pulse laser system and nuclear measurement techniques. We propose a novel Laser-driven Exotic Nuclei extraction-acceleration…
▽ More
The measurement of properties of exotic nuclei, essential for fundamental nuclear physics, now confronts a formidable challenge for contemporary radiofrequency accelerator technology. A promising option can be found in the combination of state-of-the-art high-intensity short pulse laser system and nuclear measurement techniques. We propose a novel Laser-driven Exotic Nuclei extraction-acceleration method (LENex): a femtosecond petawatt laser, irradiating a target bombarded by an external ion beam, extracts from the target and accelerates to few GeV highly-charged nuclear reaction products. Here a proof-of-principle experiment of LENex is presented: a few hundred-terawatt laser focused onto an aluminum foil, with a small amount of iron simulating nuclear reaction products, extracts almost fully stripped iron nuclei and accelerate them up to 0.9 GeV. Our experiments and numerical simulations show that short-lived, heavy exotic nuclei, with a much larger charge-to-mass ratio than in conventional technology, can be obtained in the form of an energetic, low-emittance, high-current beam.
△ Less
Submitted 24 February, 2014;
originally announced February 2014.