Low noise optimization of an electron beam current transformer for conventional radiotherapy up to ultra high dose rate irradiations
Authors:
Chloe Lahaye,
Jean-Marc Fontbonne,
Samuel Salvador
Abstract:
Ultra high dose rate electron beams also known as FLASH radiotherapy is becoming of importance in several preclinial cancer treatment studies. However, due to the dose rate used during the irradiation sessions, no real time dose monitoring device exists to date. In this work, we present the development of a beam current transformer (BCT), from the choice of the ferromagnetic component and the real…
▽ More
Ultra high dose rate electron beams also known as FLASH radiotherapy is becoming of importance in several preclinial cancer treatment studies. However, due to the dose rate used during the irradiation sessions, no real time dose monitoring device exists to date. In this work, we present the development of a beam current transformer (BCT), from the choice of the ferromagnetic component and the realisation of the shielding to the design of a front-end electronics based on a trans-impedance circuit in order to perform a low noise optimization of the detector. The BCT prototype is able to monitor a beam current range from 1.2~\textmu A to 200~mA with a rise time constant better than 20~ns and a droop rate of the signal below 0.05\%$\cdot$\textmu s$^{-1}$. Preliminary in-situ measurements are also presented. The goal is to combine the BCT system which measure in real time the beam current, to an ionisation chamber monitoring the beam shape and position in order to provide a reliable dose monitoring system.
△ Less
Submitted 18 August, 2022; v1 submitted 13 June, 2022;
originally announced June 2022.
-
OuroborosBEM: A fast multi-GPU microscopic Monte Carlo simulation for gaseous detectors and charged particle dynamics
Authors:
G. Quéméner,
S. Salvador
Abstract:
The design of gaseous detectors for accelerator, particle and nuclear physics requires simulations relying on multi-physics aspects. In fact, these simulations deal with the dynamics of a large number of charged particles interacting in a gaseous medium immersed in the electric field generated by a more or less complex assembly of electrodes and dielectric materials. We report here on a homemade s…
▽ More
The design of gaseous detectors for accelerator, particle and nuclear physics requires simulations relying on multi-physics aspects. In fact, these simulations deal with the dynamics of a large number of charged particles interacting in a gaseous medium immersed in the electric field generated by a more or less complex assembly of electrodes and dielectric materials. We report here on a homemade software, called OUROBOROSBEM, able to tackle the different features involved in such simulations. After solving the electrostatic problem for which a solver based on the boundary element method (BEM) has been implemented, particles are tracked and will microscopically interact with the gas medium. Dynamical effects have been included such as the electron-ion recombination process, the charging-up of the dielectric materials and other space charge effects that might alter the detector performances. These were made possible thanks to the nVidia CUDA language specifically optimised to run on Graphical Processor Units (GPUs) to minimize the computing times. Comparisons of the results obtained for parallel plate avalanche counters and GEM detectors to literature data on swarm parameters fully validate the performances of OUROBOROSBEM. Moreover, we were able to precisely reproduce the measured gains of single and double GEM detectors as a function of the applied voltage.
△ Less
Submitted 3 January, 2022; v1 submitted 18 October, 2021;
originally announced October 2021.
-
Geant4 Systematic Study of the FRACAS Apparatus for Hadrontherapy Cross Section Measurements
Authors:
Edgar Barlerin,
Samuel Salvador,
Marc Labalme
Abstract:
In this work, we report on systematic Monte Carlo (MC) studies for the FRACAS apparatus, a large acceptance mass spectrometer that will be used to measure the fragmentation cross sections of $^{12}$C ions for hadrontherapy. The apparatus placed, in a 100 mbar reaction chamber, will be made of a beam monitor, trackers surrounding a magnet and a Time-Of-Flight (TOF) wall. In order to determine the r…
▽ More
In this work, we report on systematic Monte Carlo (MC) studies for the FRACAS apparatus, a large acceptance mass spectrometer that will be used to measure the fragmentation cross sections of $^{12}$C ions for hadrontherapy. The apparatus placed, in a 100 mbar reaction chamber, will be made of a beam monitor, trackers surrounding a magnet and a Time-Of-Flight (TOF) wall. In order to determine the required performances of the trackers, Geant4 simulations of the whole system and in-house developed algorithms were used. While keeping the beam monitor and TOF-wall positions fixed, the effects of the tracker positions and spatial resolutions on the trajectory reconstruction and mass identification efficiencies have been extracted. An optimal configuration was found where the upstream trackers should be located 6 cm away from the target and spaced 4 cm apart whereas their spatial resolutions should be close to 100 $μ$m. The positions of the downstream trackers will have to be changed according to the beam energy to preserve high identification efficiencies. Their spatial resolutions, even though of a lesser importance compared to the upstream trackers, should be around 1 mm or better. In this optimal configuration, an overall fragment identification efficiency above 90% has been obtained for beam energies ranging from 100 to 400 MeV/nucleon.
△ Less
Submitted 16 December, 2020; v1 submitted 17 September, 2020;
originally announced September 2020.
-
Timing performances of a Time-of-Flight detection system for the FRACAS large acceptance mass spectrometer
Authors:
S. Salvador,
E. Barlerin,
J. Perronnel,
C. Vandamme
Abstract:
In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF system is composed of a Parallel Plate Avalanche Counter and scintillating detectors to create so-called $Δ$E---TOF maps used in the fragment charge identification…
▽ More
In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF system is composed of a Parallel Plate Avalanche Counter and scintillating detectors to create so-called $Δ$E---TOF maps used in the fragment charge identification process. From tests with an alpha source and a $^{12}$C beam experiment, we measured a coincidence resolving time for the apparatus below 300 ps. Those results should lead in the final design to the identification of all the fragments produced by the interaction of $^{12}$C ions with thin targets for energies up to 400 MeV/nucleon.
△ Less
Submitted 12 February, 2020; v1 submitted 27 November, 2019;
originally announced November 2019.
-
Measurement of ion and electron drift velocity and electronic attachment in air for ionization chambers
Authors:
Guillaume Boissonnat,
Jean-Marc Fontbonne,
Jean Colin,
Aurelien Remadi,
Samuel Salvador
Abstract:
Air-ionization chambers have been used in radiotherapy and particle therapy for decades. However, fundamental parameters in action in the detector responses are sparsely studied. In this work we aimed to measure the electronic attachment, electrons and ions mobilities of an ionization chamber (IC) in air. The main idea is to extract these from the actual response of the IC to a single ionizing par…
▽ More
Air-ionization chambers have been used in radiotherapy and particle therapy for decades. However, fundamental parameters in action in the detector responses are sparsely studied. In this work we aimed to measure the electronic attachment, electrons and ions mobilities of an ionization chamber (IC) in air. The main idea is to extract these from the actual response of the IC to a single ionizing particle in order to insure that they were measured in the same condition they are to be used while neglecting undesired phenomena: recombination and space charge effect. The non-standard signal shape analysis performed here were also confronted to a more standard drift chamber measurements using time-of-flight. It was found that both detectors displayed compatible results concerning positive and negative ions drift velocities where literature data is well spread out. In the same time, electron attachment measurements sit in the middle of known measurements while electron drift velocities seemed to show an offset compared to the well known and modeled data.
△ Less
Submitted 13 September, 2016;
originally announced September 2016.
-
Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL
Authors:
G. Boissonnat,
J. -M. Fontbonne,
E. Balanzat,
F. Boumard,
B. Carniol,
A. Cassimi,
J. Colin,
D. Cussol,
D. Etasse,
C. Fontbonne,
A. -M. Frelin,
J. Hommet,
J. Peronnel,
S. Salvador
Abstract:
Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sa…
▽ More
Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one s own sample analysis to state of the art dosimetric references.
△ Less
Submitted 15 September, 2016; v1 submitted 22 July, 2016;
originally announced July 2016.
-
Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy
Authors:
J. Dudouet,
D. Juliani,
J. C. Ang elique,
B. Braunn,
J. Colin,
D. Cussol,
Ch. Finck,
J. M. Fontbonne,
H. Gu erin,
P. Henriquet,
J. Krimmer,
M. Labalme,
M. Rousseau,
M. G. Saint-Laurent,
S. Salvador
Abstract:
During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double…
▽ More
During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double di ffential carbon fragmentation cross sections are being measured in the energy range used in hadrontherapy (40 to 400 MeV/u). Therefore, new measurements are performed to determine the double di ffential cross section of carbon on di erent thin targets. This work describes the experimental results of an experiment performed on May 2011 at GANIL. The double di ffential cross sections and the angular distributions of secondary fragments produced in the 12C fragmentation at 95 MeV/u on thin targets (C, CH2, Al, Al2O3, Ti and PMMA) have been measured. The experimental setup will be precisely described, the systematic error study will be explained and all the experimental data will be presented.
△ Less
Submitted 3 June, 2013;
originally announced June 2013.