-
Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
Authors:
D. Bosnar,
L. Abbene,
C. Amsler,
F. Artibani,
M. Bazzi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
M. Makek,
S. Manti,
J. Marton
, et al. (17 additional authors not shown)
Abstract:
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present…
▽ More
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
Biophotons: A Hard Problem
Authors:
L. De Paolis,
R. Francini,
I. Davoli,
F. De Matteis,
A. Scordo,
A. Clozza,
M. Grandi,
E. Pace,
C. Curceanu,
P. Grigolini,
M. Benfatto
Abstract:
About a hundred years ago the Russian biologist A. Gurwitsch, based on his experiments with onion plants by measuring their growth rate, made the hypothesis that plants emitted a weak electromagnetic field which somehow influenced cell growth. This interesting observation remained fundamentally ignored by the scientific community and only in the 1950s the electromagnetic emission from some plants…
▽ More
About a hundred years ago the Russian biologist A. Gurwitsch, based on his experiments with onion plants by measuring their growth rate, made the hypothesis that plants emitted a weak electromagnetic field which somehow influenced cell growth. This interesting observation remained fundamentally ignored by the scientific community and only in the 1950s the electromagnetic emission from some plants was measured using a photomultiplier used in single counting mode. Later, in the 80s several groups in the world started some extensive work to understand the origin and role of this ultra-weak emission, hereby called biophotons, coming from living organisms. Biophotons are an endogenous very small production of photons in the visible energy range in and from cells and organism, and this emission is characteristic of alive organisms. Today there is no doubt that biophotons really exist, this emission has in fact been measured by many groups and on many different living organisms, from humans to bacteria. On the contrary, the origin of biophotons and whether organisms use them in some way to exchange information is not yet well known; no model proposed since now is really capable of reproducing and interpreting the great variety of experimental data coming from the many different living systems measured so far. In this brief review we present our experimental work on biophotons coming from germinating seeds, the main experimental results and some methods we are using to analyze the data in order to open the door for interpretative models of this phenomenon and clarifying its function in the regulation and communication between cells and living organisms. We also discuss some ideas on how to increase the signal-to-noise ratio of the measured signal to have new experimental possibilities that allow the measurement and the characterization of currently unmeasurable quantities.
△ Less
Submitted 30 January, 2024;
originally announced January 2024.
-
SIDDHARTA-2 apparatus for kaonic atoms research on the DA$Φ$NE collider
Authors:
F. Sirghi,
F. Sgaramella,
L. Abbene,
C. Amsler,
M. Bazzi,
G. Borghi,
D. Bosnar,
M. Bragadireanu,
A. Buttacavoli,
M. Carminati,
M. Cargnelli,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (19 additional authors not shown)
Abstract:
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA…
▽ More
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA$Φ$NE electron-positron collider, of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p$\rightarrow$1s X-ray transitions in kaonic deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic hydrogen 2p$\rightarrow$1s X-ray transitions, the present apparatus has been upgraded with innovative Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider. We present a comprehensive description of the SIDDHARTA-2 setup including the optimization of its various components during the commissioning phase of the collider.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
CdZnTe detectors tested at the DAΦNE collider for future kaonic atoms measurements
Authors:
A. Scordo,
L. Abbene,
F. Artibani,
M. Bazzi,
M. Bettelli,
D. Bosnar,
G. Borghi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
L. De Paolis,
G. Deda,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (20 additional authors not shown)
Abstract:
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam deli…
▽ More
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam delivered by the at-rest decay of the $φ$ meson. CdZnTe devices are ideal for detecting transitions toward both the upper and lower levels of intermediate-mass kaonic atoms, like kaonic carbon and aluminium, which have an important impact on the strangeness sector of nuclear physics. We present the results obtained in a set of preliminary tests conducted on DA$Φ$NE, in view of measurements foreseen in 2024, with the twofold aim to tune the timing window required to reject the extremely high electromagnetic background, and to quantify the readout electronics saturation effect due to the high rate, when placed close to the Interaction Region (IR). In the first test we used commercial devices and electronics, while for the second one both were customized at the IMEM-CNR of Parma and the University of Palermo. The results confirmed the possibility of finding and matching a proper timing window where to identify the signal events and proved better performances, in terms of energy resolution, of the custom system. In both cases, strong saturation effects were confirmed, accounting for a loss of almost 90\% of the events, which will be overcome by a dedicated shielding structure foreseen for the final experimental setup.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Detecting Iron Oxidation States in Liquids with the VOXES Bragg Spectrometer
Authors:
Simone Manti,
Marco Miliucci,
Alessandro Scordo,
Roberto Bedogni,
Alberto Clozza,
Mihail Iliescu,
Gabriel Moskal,
Kristian Piscicchia,
Alessio Porcelli,
Diana Sirghi,
Florin Sirghi,
Catalina Curceanu
Abstract:
Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, her…
▽ More
Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, here we present the MITIQO project, which aims to identify oxidation states of metals in edible liquids utilizing X-ray emission with Bragg spectroscopy. This is achieved using the VOXES crystal spectrometer, developed at INFN National Laboratories of Frascati (LNF), employing mosaic crystal (HAPG) in the Von Hamos configuration. This combination allow us to work with effective source sizes of up to a few millimeters and improves the typical low efficiency of Bragg spectroscopy, a crucial aspect when studying liquids with low metal concentration. Here we showcase the concept behind MITIQO, for a liquid solution containing oxidized iron. We performed several high-resolution emission spectra measurements, for the liquid and for different powdered samples containing oxidized and pure iron. By looking at the spectral features of the iron's K$β$ emission lineshape, we were able to obtain, for a liquid, a result consistent with the oxidized iron powders and successfully quantifying the effect of oxidation.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Novel Machine Learning and Differentiable Programming Techniques applied to the VIP-2 Underground Experiment
Authors:
F Napolitano,
M Bazzi,
M Bragadireanu,
M Cargnelli,
A Clozza,
L De Paolis,
R Del Grande,
C Fiorini,
C Guaraldo,
M Iliescu,
M Laubenstein,
S Manti,
J Marton,
M Miliucci,
K Piscicchia,
A Porcelli,
A Scordo,
F Sgaramella,
D Sirghi,
F Sirghi,
O Doce,
J Zmeskal,
C Curceanu
Abstract:
In this work, we present novel Machine Learning and Differentiable Programming enhanced calibration techniques used to improve the energy resolution of the Silicon Drift Detectors (SDDs) of the VIP-2 underground experiment at the Gran Sasso National Laboratory (LNGS). We achieve for the first time a Full Width at Half Maximum (FWHM) in VIP-2 below 180 eV at 8 keV, improving around 10 eV on the pre…
▽ More
In this work, we present novel Machine Learning and Differentiable Programming enhanced calibration techniques used to improve the energy resolution of the Silicon Drift Detectors (SDDs) of the VIP-2 underground experiment at the Gran Sasso National Laboratory (LNGS). We achieve for the first time a Full Width at Half Maximum (FWHM) in VIP-2 below 180 eV at 8 keV, improving around 10 eV on the previous state-of-the-art. SDDs energy resolution is a key parameter in the VIP-2 experiment, which is dedicated to searches for physics beyond the standard quantum theory, targeting Pauli Exclusion Principle (PEP) violating atomic transitions. Additionally, we show that this method can correct for potential miscalibrations, requiring less fine-tuning with respect to standard methods.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
Biophotons -- new experimental data and analysis
Authors:
M. Benfatto,
E. Pace,
I. Davoli,
Massimiliano Lucci,
R. Francini,
Fabio De Matteis,
Alessandro Scordo,
Alberto Clozza,
Maurizio Grandi,
C. Curceanu,
P. Grigolini
Abstract:
Biophotons are an ultra-weak emission of photons in the visible energy range from living matter. In this work, we study the emission from germinating seeds using an experimental technique designed to detect light of extremely small intensity. The emission from lentil seeds and single bean was analyzed during the whole germination process in terms of both the different spectral components through l…
▽ More
Biophotons are an ultra-weak emission of photons in the visible energy range from living matter. In this work, we study the emission from germinating seeds using an experimental technique designed to detect light of extremely small intensity. The emission from lentil seeds and single bean was analyzed during the whole germination process in terms of both the different spectral components through low pass filters and the different count distributions in the various stages of the germination process. Although the shape of the emission spectrum appears to be very similar in the two samples used in our experiment, our analysis is able to highlight the differences present in the two cases. In this way, it was possible to correlate the various types of emissions to the degree of development of the seed during germination.
△ Less
Submitted 16 May, 2023;
originally announced May 2023.
-
Measurements of high-n transitions in intermediate mass kaonic atoms by SIDDHARTA-2 at DA$\mathrmΦ$NE
Authors:
F. Sgaramella,
M. Tüchler,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
R. Del Grande,
L. De Paolis,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki
, et al. (16 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell…
▽ More
The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell with aluminium frames and Kapton walls, and are reported in this paper. These new kaonic atoms measurements add valuable input to the kaonic atoms transitions data base, which is used as a reference for theories and models of the low-energy strong interaction between antikaon and nuclei. Moreover, these results pave the way for future dedicated kaonic atoms measurements through the whole periodic table and to a new era for the antikaon-nuclei studies at low energy.
△ Less
Submitted 22 April, 2023;
originally announced April 2023.
-
New opportunities for kaonic atoms measurements from CdZnTe detectors
Authors:
L. Abbene,
M. Bettelli,
A. Buttacavoli,
F. Principato,
A. Zappettini,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton,
M. Miliucci
, et al. (20 additional authors not shown)
Abstract:
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an…
▽ More
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an $^{241}Am$ source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of $\simeq10^{5-6}$, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy
Authors:
A. Khreptak,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Carminati,
M. Cargnelli,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki,
H. Ohnishi,
K. Piscicchia,
Y. Sada
, et al. (14 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in…
▽ More
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.
△ Less
Submitted 31 August, 2022;
originally announced August 2022.
-
First tests of the full SIDDHARTA-2 experimental apparatus with a 4 He gaseous target
Authors:
A. Scordo,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
P. King,
P. Levi Sandri,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki
, et al. (16 additional authors not shown)
Abstract:
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger syst…
▽ More
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger system, was required. This run, performed in the period 04-26/05/2022 with a 4 He gaseous target, confirmed the 10^5 rejection factor obtained with a reduced version of the setup and different machine conditions in 2021. This important outcome motivated the filling of the target cell with deuterium and the starting of the measurement campaign of the kaonic deuterium 2p{\rightarrow}1s transition.
△ Less
Submitted 4 August, 2022;
originally announced August 2022.
-
The SIDDHARTA-2 calibration method for high precision kaonic atoms X-ray spectroscopy measurements
Authors:
F Sgaramella,
M Miliucci,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P King,
P Levi Sandri,
J Marton,
P Moskal,
F Napolitano,
S Niedźwiecki,
K Piscicchia,
A Scordo,
H Shi,
M Silarski
, et al. (7 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 c…
▽ More
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 collaboration are suitable for high precision kaonic atoms spectroscopy, thanks to their high energy and time resolutions combined with their radiation hardness. The energy response of each detector must be calibrated and monitored to keep the systematic error, due to processes such as gain fluctuations, at the level of 2-3 eV. This paper presents the SIDDHARTA-2 calibration method which was optimized during the preliminary phase of the experiment in the real background conditions of the DA$Φ$NE collider, which is a fundamental tool to guarantee the high precision spectroscopic performances of the system over long periods of data taking, as that required for the kaonic deuterium measurement.
△ Less
Submitted 28 January, 2022;
originally announced January 2022.
-
Kaonic Atoms at the DA$Φ$NE Collider with the SIDDHARTA-2 Experiment
Authors:
F Napolitano,
F Sgaramella,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
L Fabbietti,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P Levi Sandri,
J Marton,
M Miliucci,
P Moskal,
S Niedźwiecki,
K Piscicchia,
A Scordo,
H Shi,
D Sirghi
, et al. (7 additional authors not shown)
Abstract:
Kaonic atoms are a unique tool to explore quantum chromodynamics in the strangeness sector at low energy, with implications reaching neutron stars and dark matter. Precision X-ray spectroscopy can fully unlock the at-threshold isospin dependent antikaon-nucleon scattering lengths, via the atomic transitions to the fundamental level. While the SIDDHARTA experiment at the INFN-LNF DA$Φ$NE collider s…
▽ More
Kaonic atoms are a unique tool to explore quantum chromodynamics in the strangeness sector at low energy, with implications reaching neutron stars and dark matter. Precision X-ray spectroscopy can fully unlock the at-threshold isospin dependent antikaon-nucleon scattering lengths, via the atomic transitions to the fundamental level. While the SIDDHARTA experiment at the INFN-LNF DA$Φ$NE collider successfully measured kaonic hydrogen, its successor SIDDHARTA-2 is starting now its data taking campaign aiming to finally fully disentangle the isoscalar and isovector scattering lengths via the measurement of kaonic deuterium. An overview of the first experimental results from a preparatory run for the SIDDAHARTA-2 experiment is presented.
△ Less
Submitted 27 January, 2022;
originally announced January 2022.
-
A new kaonic helium measurement in gas by SIDDHARTINO at the DAΦNE collider
Authors:
D Sirghi,
F Sirghi,
F Sgaramella,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
L Fabbietti,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P Levi Sandri,
J Marton,
M Miliucci,
P Moskal,
F Napolitano,
S Niedźwiecki,
K Piscicchia,
A Scordo
, et al. (8 additional authors not shown)
Abstract:
The SIDDHARTINO experiment at the DAΦNE Collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the fundamental level, has successfully been concluded. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the f…
▽ More
The SIDDHARTINO experiment at the DAΦNE Collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the fundamental level, has successfully been concluded. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the fraction of kaons stopped inside the target, through measurements of kaonic helium transitions to the 2p level. The obtained shift and width values are ε_2p = E_exp-E_e.m = 0.2 {\pm} 2.5(stat) {\pm} 2(syst) eV and Γ_2p = 8 {\pm} 10 eV (stat), respectively. This new measurement of the shift, in particular, represents the most precise one for a gaseous target and is expected to contribute to a better understanding of the kaon-nuclei interaction at low energy.
△ Less
Submitted 24 January, 2022;
originally announced January 2022.
-
Silicon Drift Detectors spectroscopic response during the SIDDHARTA-2 Kaonic Helium run at the DAΦNE collider
Authors:
Marco Miliucci,
Massimiliano Bazzi,
Damir Bosnar,
Mario Bragadireanu,
Marco Carminati,
Michael Cargnelli,
Alberto Clozza,
Catalina Curceanu,
Griseld Deda,
Luca De Paolis,
Raffaele Del Grande,
Carlo Fiorini,
Carlo Guaraldo,
Mihail Iliescu,
Masahiko Iwasaki,
Pietro King,
Paolo Levi Sandri,
Johann Marton,
Paweł Moskal,
Fabrizio Napolitano,
Szymon Niedźwiecki,
Kristian Piscicchia,
Alessandro Scordo,
Francesco Sgaramella,
Hexi Shi
, et al. (8 additional authors not shown)
Abstract:
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high prec…
▽ More
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high precision light kaonic atoms spectroscopy measurements in the high background of the DAΦNE collider. This work presents the spectroscopic response of the SDDs system during the kaonic helium first exotic atoms run of SIDDHARTA-2, preliminary to the kaonic deuterium data taking campaign
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Reflection efficiency and spectra resolutions ray-tracing simulations for the VOXES HAPG crystal based Von Hamos spectrometer
Authors:
V. De Leo,
A. Scordo,
C. Curceanu,
M. Miliucci,
F. Sirghi
Abstract:
The VOXES collaboration at INFN National Laboratories of Frascati developed a prototype of a high resolution Von Hamos X-ray spectrometer using HAPG (Highly Annealed Pyrolytic Graphite) mosaic crystals. This technology allows the employment of extended isotropic sources and could find application in several physics fields. The capability of the spectrometer to reach energy precision and resolution…
▽ More
The VOXES collaboration at INFN National Laboratories of Frascati developed a prototype of a high resolution Von Hamos X-ray spectrometer using HAPG (Highly Annealed Pyrolytic Graphite) mosaic crystals. This technology allows the employment of extended isotropic sources and could find application in several physics fields. The capability of the spectrometer to reach energy precision and resolution below 1 and 10 eV, respectively, when used with wide sources have been already demonstrated. Recently, the response of this device, for a $ρ$ = 206.7 mm cylindrically bent HAPG crystal using $CuKα_{1,2}$ and $FeKα_{1,2}$ XRF lines, has been investigated in terms of reflection efficiency by a dedicated ray-tracing simulation. Details of the simulation procedure and the comparison with the experimental results are presented. This study is crucial in order to retrieve information on the spectrometer signal collection efficiency, especially in the energy range in which the standard calibration procedures cannot be applied.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Characterization of the SIDDHARTA-2 luminosity monitor
Authors:
M. Skurzok,
A. Scordo,
S. Niedzwiecki,
A. Baniahmad,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Carminati,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
P. Levi Sandri,
J. Marton,
M. Miliucci,
P. Moskal,
K. Piscicchia,
F. Sgaramella,
H. Shi
, et al. (7 additional authors not shown)
Abstract:
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and was installed in 2020 on the DAFNE $e^+e^-$ collider at LNF (Laboratori Nazionali di Frascati, INFN). The main goal of this system is to provide the~instantaneous and integrated luminosity of the DAFNE facility by measuri…
▽ More
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and was installed in 2020 on the DAFNE $e^+e^-$ collider at LNF (Laboratori Nazionali di Frascati, INFN). The main goal of this system is to provide the~instantaneous and integrated luminosity of the DAFNE facility by measuring the rate of $K^+K^-$ correlated pairs emitted by the phi meson decay. This task requires an accurate timing of the DAQ signals, as well as timing resolution below 1ns, in order to disentangle the $K^\pm$ signals from the background minimum ionizing particles (MIPs) produced during the $e^+e^-$ collisions at DAFNE. In this paper the luminosity monitor concept as well as its laboratory characterization and the first results inside DAFNE are presented.
△ Less
Submitted 15 October, 2020; v1 submitted 12 August, 2020;
originally announced August 2020.
-
VIP2 in LNGS - Testing the Pauli Exclusion Principle for electrons with high sensitivity
Authors:
J. Marton,
A. Pichler,
A. Amirkhani,
S. Bartalucci,
M. Bazzi,
S. Bertolucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
R. Del Grande,
L. De Paolis,
J. -P. Egger,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
E. Milotti,
M. Milucci,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
H. Shi,
D. Sirghi,
F. Sirghi
, et al. (3 additional authors not shown)
Abstract:
The VIP2 (VIolation of the Pauli Exclusion Principle) experiment at the Gran Sasso underground laboratory (LNGS) is searching for possible violations of standard quantum mechanics predictions in atoms at very high sensitivity. We investigate atomic transitions with precision X-ray spectroscopy in order to test the Pauli Exclusion Principle (PEP) and therefore the related spin-statistics theorem. W…
▽ More
The VIP2 (VIolation of the Pauli Exclusion Principle) experiment at the Gran Sasso underground laboratory (LNGS) is searching for possible violations of standard quantum mechanics predictions in atoms at very high sensitivity. We investigate atomic transitions with precision X-ray spectroscopy in order to test the Pauli Exclusion Principle (PEP) and therefore the related spin-statistics theorem. We will present our experimental method for the search for "anomalous" (i.e. Pauli-forbidden) X-ray transitions in copper atoms, produced by "new" electrons, which could have tiny probability to undergo Pauli-forbidden transition to the ground state already occupied by two electrons. We will describe the VIP2 experimental setup, which is taking data at LNGS presently. The goal of VIP2 is to test the PEP for electrons with unprecedented accuracy, down to a limit in the probability that PEP is violated at the level of 10$^{-31}$. We will present current experimental results and discuss implications of a possible violation.
△ Less
Submitted 21 March, 2019;
originally announced March 2019.
-
Development of a compact HAPG crystal Von Hamos X-ray spectrometer forextended and diffused sources
Authors:
A. Scordo,
C. Curceanu,
M. Miliucci,
F. Sirghi,
J. Zmeskal
Abstract:
Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements; however, this technique is limited to the measurement of photons producedfrom well collimated (tens of microns) or point-like sources and becomes quite inefficient for photonscoming from extended and diffused sources. The possibility to perform simultaneous measurementsof several e…
▽ More
Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements; however, this technique is limited to the measurement of photons producedfrom well collimated (tens of microns) or point-like sources and becomes quite inefficient for photonscoming from extended and diffused sources. The possibility to perform simultaneous measurementsof several energies is strongly demanded when low rate signals are expected and single angular scansrequire long exposure times. A prototype of a high resolution and high precision X-ray spectrometerworking also with extended isotropic sources, has been developed by the VOXES collaboration atINFN Laboratories of Frascati, using Highly Annealed Pyrolitic Graphite (HAPG) crystals in a semi- Von Hamos configuration, in which the position detector is rotated with respect to thestandard Von Hamos one, to increase the dynamic energy range. The aim is to deliver a cost effectivesystem having an energy resolution at the level of eV for X-ray energies from about 2 keV up to tensof keV, able to perform sub-eV precision measurements with non point-like sources. The proposedspectrometer has possible applications in several fields, going from fundamental physics to quantummechanics tests, synchrotron radiation and X-FEL applications, astronomy, medicine and industry.In particular, this technique is fundamental for a series of nuclear physics measurements like, forexample, the energies of the exotic atoms radiative transitions which allow to extract fundamentalparameters in the low energy QCD in the strangeness sector. In this work, the working principleof the spectrometer is presented, together with the tests and the results, in terms of resolution andsource, size obtained for Fe(K\alpha1,2), Cu(K\alpha1,2), Ni(Kβ), Zn(K\alpha1,2), Mo(K\alpha1,2) and Nb(Kβ)lines.
△ Less
Submitted 7 March, 2019;
originally announced March 2019.
-
Detector setup of the VIP2 Underground Experiment at LNGS
Authors:
J. Marton,
A. Pichler,
H. Shi,
E. Milotti,
S. Bartalucci,
M. Bazzi,
S. Bertolucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
J. -P. Egger,
H. Elnaggar,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
M. Miliucci,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
D. L. Sirghi,
F. Sirghi,
L. Sperandio
, et al. (3 additional authors not shown)
Abstract:
The VIP2 experiment tests the Pauli Exclusion Principle with high sensitivity, by searching for Pauli-forbidden atomic transitions from the 2p to the 1s shell in copper at about 8keV. The transition energy of Pauli-forbidden K X-rays is shifted by about 300 eV with respect to the normal allowed K line. This energy difference can be resolved using Silicon Drift Detectors. The data for this experime…
▽ More
The VIP2 experiment tests the Pauli Exclusion Principle with high sensitivity, by searching for Pauli-forbidden atomic transitions from the 2p to the 1s shell in copper at about 8keV. The transition energy of Pauli-forbidden K X-rays is shifted by about 300 eV with respect to the normal allowed K line. This energy difference can be resolved using Silicon Drift Detectors. The data for this experiment is taken in the Gran Sasso underground laboratory (LNGS), which provides shielding from cosmic radiation. An overview of the detection system of the VIP2 experiment will be given. This includes the Silicon Drift Detectors used as X-ray detectors which provide an energy resolution of around 150 eV at 6 keV and timing information for active shielding. Furthermore, the low maintenance requirement makes them excellent X-ray detectors for the use in an underground laboratory. The VIP2 setup will be discussed which consists of a high current target system and a passive as well as an active shielding system using plastic scintillators read out by Silicon Photomultipliers.
△ Less
Submitted 4 July, 2018;
originally announced July 2018.
-
Experimental search for the violation of Pauli Exclusion Principle
Authors:
H. Shi,
E. Milotti,
S. Bartalucci,
M. Bazzi,
S. Bertolucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
L. De Paolis,
S. Di Matteo,
J. -P. Egger,
H. Elnaggar,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
J. Marton,
M. Miliucci,
A. Pichler,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
D. L. Sirghi,
F. Sirghi,
L. Sperandio,
O. Vazquez Doce
, et al. (3 additional authors not shown)
Abstract:
The VIolation of Pauli exclusion principle -2 experiment, or VIP-2 experiment, at the Laboratori Nazionali del Gran Sasso searches for x-rays from copper atomic transition that are prohibited by the Pauli Exclusion Principle. Candidate direct violation events come from the transition of a $2p$ electron to the ground state that is already occupied by two electrons. From the first data taking campai…
▽ More
The VIolation of Pauli exclusion principle -2 experiment, or VIP-2 experiment, at the Laboratori Nazionali del Gran Sasso searches for x-rays from copper atomic transition that are prohibited by the Pauli Exclusion Principle. Candidate direct violation events come from the transition of a $2p$ electron to the ground state that is already occupied by two electrons. From the first data taking campaign in 2016 of VIP-2 experiment, we determined a best upper limit of 3.4 $\times$ 10$^{-29}$ for the probability that such a violation exists. Significant improvement in the control of the experimental systematics was also achieved, although not explicitly reflected in the improved upper limit. By introducing a simultaneous spectral fit of the signal and background data in the analysis, we succeeded in taking into account systematic errors that could not be evaluated previously in this type of measurements.
△ Less
Submitted 23 April, 2018; v1 submitted 12 April, 2018;
originally announced April 2018.
-
VOXES: a high precision X-ray spectrometer for diffused sources with HAPG crystals in the 2-20 keV range
Authors:
A. Scordo,
C. Curceanu,
M. Miliucci,
H. Shi,
F. Sirghi,
J. Zmeskal
Abstract:
Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements and has been widely used in several fields, going from fundamental physics to quantum mechanics tests, synchrotron radiation and X-FEL applications, astronomy, medicine and industry. However, this technique is limited to the measurement of photons produced from well collimated or po…
▽ More
Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements and has been widely used in several fields, going from fundamental physics to quantum mechanics tests, synchrotron radiation and X-FEL applications, astronomy, medicine and industry. However, this technique is limited to the measurement of photons produced from well collimated or point-like sources and becomes quite inefficient for photons coming from extended and diffused sources like those,for example, emitted in the exotic atoms radiative transitions. The VOXES project's goal is to realise a prototype of a high resolution and high precision X-ray spectrometer, using Highly Annealed Pyrolitic Graphite (HAPG) crystals in the Von Hamos configuration, working also for extended sources. The aim is to deliver a cost effective system having an energy resolution at the level of eV for X rays energies from about 2 keV up to tens of keV, able to perform sub-eV precision measurements with non point-like sources. In this paper, the working principle of VOXES, together with first results, are presented.
△ Less
Submitted 2 July, 2018; v1 submitted 19 January, 2018;
originally announced January 2018.
-
VIP2 at Gran Sasso - Test of the validity of the spin statistics theorem for electrons with X-ray spectroscopy
Authors:
J. Marton,
A. Pichler,
S. Bartalucci,
M. Bazzi,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
H. Shi,
D. Sirghi,
F. Sirghi,
L. Sperandio,
O. Vazquez-Doce
, et al. (2 additional authors not shown)
Abstract:
In the VIP2 (VIolation of the Pauli Exlusion Principle) experiment at the Gran Sasso underground laboratory (LNGS) we are searching for possible violations of standard quantum mechanics predictions. With high precision we investigate the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We will present our experimental method of searching for possible small violati…
▽ More
In the VIP2 (VIolation of the Pauli Exlusion Principle) experiment at the Gran Sasso underground laboratory (LNGS) we are searching for possible violations of standard quantum mechanics predictions. With high precision we investigate the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We will present our experimental method of searching for possible small violations of the Pauli Exclusion Principle for electrons, via the search for "anomalous" X-ray transitions in copper atoms, produced by "new" electrons (brought inside a copper bar by circulating current) which could have the probability to undergo Pauli-forbidden transition to the ground state (1 s level) already occupied by two electrons. We will describe the concept of the VIP2 experiment taking data at LNGS presently. The goal of VIP2 is to test the PEP for electrons with unprecedented accuracy, down to a limit in the probability that PEP is violated at the level of 10$^{-31}$. We will show preliminary experimental results obtained at LNGS and discuss implications of a possible violation.
△ Less
Submitted 3 November, 2017;
originally announced November 2017.
-
VOXES, a new high resolution X-ray spectrometer for low yield measurements with diffused sources
Authors:
A. Scordo,
H. Shi,
C. Curceanu,
M. Miliucci,
F. Sirghi,
J. Zmeskal
Abstract:
The VOXES project's goal is to realize the first prototype of a high resolution and high precision X-ray spectrometer for diffused sources, using Highly Annealed Pyrolitic Graphite (HAPG) crystals combined with precision position detectors. The aim is to deliver a cost effective and easy to handle system having an energy resolution at the level of few eV for X-ray energies from about 2 keV up to t…
▽ More
The VOXES project's goal is to realize the first prototype of a high resolution and high precision X-ray spectrometer for diffused sources, using Highly Annealed Pyrolitic Graphite (HAPG) crystals combined with precision position detectors. The aim is to deliver a cost effective and easy to handle system having an energy resolution at the level of few eV for X-ray energies from about 2 keV up to tens of keV. There are many applications of the proposed spectrometer, going from fundamental physics (precision measurements of exotic atoms at DA$Φ$NE collider and J-PARC, precision measurement of the $K^-$ mass solving the existing puzzle, quantum mechanics tests) to synchrotron radiation and applications (X-FEL), astronomy, medicine and industry. Here, the basic concept of such a spectrometer and the first results from a measurement of the characteristic Cu $K_{α1}$ and $K_{α2}$ X-ray lines are presented.
△ Less
Submitted 19 September, 2017;
originally announced September 2017.
-
Test of the Pauli Exclusion Principle in the VIP-2 underground experiment
Authors:
C. Curceanu,
H. Shi,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
L. De Paolis,
S. Di Matteo,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
J. Marton,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
D. L. Sirghi,
F. Sirghi,
L. Sperandio,
O. Vazquez Doce,
E. Widmann,
J. Zmeskal
Abstract:
The validity of the Pauli Exclusion Principle, a building block of Quantum Mechanics, is tested for electrons. The VIP (VIolation of Pauli exclusion principle) and its follow-up VIP-2 experiments at the Laboratori Nazionali del Gran Sasso search for x-rays from copper atomic transition that are prohibited by the Pauli Exclusion Principle. The candidate events, if they exist, originate from the tra…
▽ More
The validity of the Pauli Exclusion Principle, a building block of Quantum Mechanics, is tested for electrons. The VIP (VIolation of Pauli exclusion principle) and its follow-up VIP-2 experiments at the Laboratori Nazionali del Gran Sasso search for x-rays from copper atomic transition that are prohibited by the Pauli Exclusion Principle. The candidate events, if they exist, originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two electrons. The present limit on the probability for Pauli Exclusion Principle violation for electrons set by the VIP experiment is 4.7 $\times$ 10 $^{-29}$. We report a first result from the VIP-2 experiment improving on the VIP limit, that solidifies the final goal to achieve a two order of magnitude gain in the long run.
△ Less
Submitted 15 December, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
Underground test of quantum mechanics - the VIP2 experiment
Authors:
Johann Marton,
S. Bartalucci,
A. Bassi,
M. Bazzi,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
Catalina Curceanu,
L. De Paolis,
S. Di Matteo,
S. Donadi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
E. Milotti,
Andreas Pichler,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
H. Shi,
D. Sirghi F. Sirghi,
L. Sperandio
, et al. (3 additional authors not shown)
Abstract:
We are experimentally investigating possible violations of standard quantum mechanics predictions in the Gran Sasso underground laboratory in Italy. We test with high precision the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We present our method of searching for possible small violations of the Pauli Exclusion Principle (PEP) for electrons, through the searc…
▽ More
We are experimentally investigating possible violations of standard quantum mechanics predictions in the Gran Sasso underground laboratory in Italy. We test with high precision the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We present our method of searching for possible small violations of the Pauli Exclusion Principle (PEP) for electrons, through the search for anomalous X-ray transitions in copper atoms, produced by fresh electrons (brought inside the copper bar by circulating current) which can have the probability to undergo Pauli-forbidden transition to the 1 s level already occupied by two electrons and we describe the VIP2 (VIolation of PEP) experiment under data taking at the Gran Sasso underground laboratories. In this paper the new VIP2 setup installed in the Gran Sasso underground laboratory will be presented. The goal of VIP2 is to test the PEP for electrons with unprecedented accuracy, down to a limit in the probability that PEP is violated at the level of 10$^{-31}$. We show preliminary experimental results and discuss implications of a possible violation.
△ Less
Submitted 26 April, 2017; v1 submitted 29 March, 2017;
originally announced March 2017.
-
Underground tests of quantum mechanics. Whispers in the cosmic silence?
Authors:
C. Curceanu,
S. Bartalucci,
A. Bassi,
M. Bazzi,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
L. De Paolis,
S. Di Matteo,
S. Donadi,
J-P. Egger,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
J. Marton,
E. Milotti,
A. Pichler,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
H. Shi,
D. Sirghi,
F. Sirghi
, et al. (3 additional authors not shown)
Abstract:
By performing X-rays measurements in the "cosmic silence" of the underground laboratory of Gran Sasso, LNGS-INFN, we test a basic principle of quantum mechanics: the Pauli Exclusion Principle (PEP), for electrons. We present the achieved results of the VIP experiment and the ongoing VIP2 measurement aiming to gain two orders of magnitude improvement in testing PEP. We also use a similar experiment…
▽ More
By performing X-rays measurements in the "cosmic silence" of the underground laboratory of Gran Sasso, LNGS-INFN, we test a basic principle of quantum mechanics: the Pauli Exclusion Principle (PEP), for electrons. We present the achieved results of the VIP experiment and the ongoing VIP2 measurement aiming to gain two orders of magnitude improvement in testing PEP. We also use a similar experimental technique to search for radiation (X and gamma) predicted by continuous spontaneous localization models, which aim to solve the "measurement problem".
△ Less
Submitted 20 March, 2017;
originally announced March 2017.
-
VIP-2 at LNGS: An experiment on the validity of the Pauli Exclusion Principle for electrons
Authors:
J. Marton,
S. Bartalucci,
A. Bassi,
M. Bazzi,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
S. Donadi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
M. Laubenstein,
E. Milotti,
A. Pichler,
D. Pietreanu,
K. Piscicchia,
A. Scordo,
H. Shi,
D. Sirghi,
F. Sirghi
, et al. (4 additional authors not shown)
Abstract:
We are experimentally investigating possible violations of standard quantum mechanics predictions in the Gran Sasso underground laboratory in Italy. We test with high precision the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We present our method of searching for possible small violations of the Pauli Exclusion Principle (PEP) for electrons, through the searc…
▽ More
We are experimentally investigating possible violations of standard quantum mechanics predictions in the Gran Sasso underground laboratory in Italy. We test with high precision the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We present our method of searching for possible small violations of the Pauli Exclusion Principle (PEP) for electrons, through the search for anomalous X-ray transitions in copper atoms. These transitions are produced by new electrons (brought inside the copper bar by circulating current) which can have the possibility to undergo Pauli-forbidden transition to the 1s level already occupied by two electrons. We describe the VIP2 (VIolation of the Pauli Exclusion Principle) experimental data taking at the Gran Sasso underground laboratories. The goal of VIP2 is to test the PEP for electrons in agreement with the Messiah-Greenberg superselection rule with unprecedented accuracy, down to a limit in the probability that PEP is violated at the level of 10E-31. We show preliminary experimental results and discuss implications of a possible violation.
△ Less
Submitted 5 March, 2017;
originally announced March 2017.
-
Application of photon detectors in the VIP2 experiment to test the Pauli Exclusion Principle
Authors:
A. Pichler,
S. Bartalucci,
M. Bazzi,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. D'Uffizi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
J. Marton,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
E. Sbardella,
A. Scordo,
H. Shi
, et al. (6 additional authors not shown)
Abstract:
The Pauli Exclusion Principle (PEP) was introduced by the austrian physicist Wolfgang Pauli in 1925. Since then, several experiments have checked its validity. From 2006 until 2010, the VIP (VIolation of the Pauli Principle) experiment took data at the LNGS underground laboratory to test the PEP. This experiment looked for electronic 2p to 1s transitions in copper, where 2 electrons are in the 1s…
▽ More
The Pauli Exclusion Principle (PEP) was introduced by the austrian physicist Wolfgang Pauli in 1925. Since then, several experiments have checked its validity. From 2006 until 2010, the VIP (VIolation of the Pauli Principle) experiment took data at the LNGS underground laboratory to test the PEP. This experiment looked for electronic 2p to 1s transitions in copper, where 2 electrons are in the 1s state before the transition happens. These transitions violate the PEP. The lack of detection of X-ray photons coming from these transitions resulted in a preliminary upper limit for the violation of the PEP of $4.7 \times 10^{-29}$. Currently, the successor experiment VIP2 is under preparation. The main improvements are, on one side, the use of Silicon Drift Detectors (SDDs) as X-ray photon detectors. On the other side an active shielding is implemented, which consists of plastic scintillator bars read by Silicon Photomultipliers (SiPMs). The employment of these detectors will improve the upper limit for the violation of the PEP by around 2 orders of magnitude.
△ Less
Submitted 2 February, 2016;
originally announced February 2016.
-
VIP 2: Experimental tests of the Pauli Exclusion Principle for electrons
Authors:
A. Pichler,
S. Bartalucci,
M. Bazzi,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. D'Uffizi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
J. Marton,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
E. Sbardella,
A. Scordo,
H. Shi
, et al. (6 additional authors not shown)
Abstract:
The Pauli Exclusion Principle (PEP) was famously discovered in 1925 by the austrian physicist Wolfgang Pauli. Since then, it underwent several experimental tests. Starting in 2006, the VIP (Violation of the Pauli Principle) experiment looked for 2p to 1s X-ray transitions in copper, where 2 electrons are present in the 1s state before the transition happens. These transitions violate the PEP, and…
▽ More
The Pauli Exclusion Principle (PEP) was famously discovered in 1925 by the austrian physicist Wolfgang Pauli. Since then, it underwent several experimental tests. Starting in 2006, the VIP (Violation of the Pauli Principle) experiment looked for 2p to 1s X-ray transitions in copper, where 2 electrons are present in the 1s state before the transition happens. These transitions violate the PEP, and the lack of detection of the corresponding X-ray photons lead to a preliminary upper limit for the violation of the PEP of 4.7 * 10^(-29). The follow-up experiment VIP 2 is currently in the testing phase and will be transported to its final destination, the underground laboratory of Gran Sasso in Italy, in autumn 2015. Several improvements compared to its predecessor like the use of new X-ray detectors and active shielding from background gives rise to a goal for the improvement of the upper limit of the probability for the violation of the Pauli Exclusion Principle of 2 orders of magnitude.
△ Less
Submitted 2 February, 2016;
originally announced February 2016.
-
Spontaneously emitted X-rays: an experimental signature of the dynamical reduction models
Authors:
C. Curceanu,
S. Bartalucci,
A. Bassi,
M. Bazzi,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
L. De Paolis,
S. Di Matteo,
S. Donadi,
A. DUffizi,
J-P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
J. Marton,
E. Milotti,
A. Pichler,
D. Pietreanu,
K. Piscicchia,
T . Ponta,
E. Sbardella
, et al. (7 additional authors not shown)
Abstract:
We present the idea of searching for X-rays as a signature of the mechanism inducing the spontaneous collapse of the wave function. Such a signal is predicted by the continuous spontaneous localization theories, which are solving the "measurement problem" by modifying the Schrodinger equation. We will show some encouraging preliminary results and discuss future plans and strategy.
We present the idea of searching for X-rays as a signature of the mechanism inducing the spontaneous collapse of the wave function. Such a signal is predicted by the continuous spontaneous localization theories, which are solving the "measurement problem" by modifying the Schrodinger equation. We will show some encouraging preliminary results and discuss future plans and strategy.
△ Less
Submitted 25 January, 2016;
originally announced January 2016.
-
Searches for the Violation of Pauli Exclusion Principle at LNGS in VIP(-2) experiment
Authors:
H Shi,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. d'Uffizi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
J. Marton,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. L. Sirghi
, et al. (5 additional authors not shown)
Abstract:
The VIP (Violation of Pauli exclusion principle) experiment and its follow-up experiment VIP-2 at the Laboratori Nazionali del Gran Sasso (LNGS) search for X-rays from Cu atomic states that are prohibited by the Pauli Exclusion Principle (PEP). The candidate events, if they exist, will originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two elect…
▽ More
The VIP (Violation of Pauli exclusion principle) experiment and its follow-up experiment VIP-2 at the Laboratori Nazionali del Gran Sasso (LNGS) search for X-rays from Cu atomic states that are prohibited by the Pauli Exclusion Principle (PEP). The candidate events, if they exist, will originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two electrons. The present limit on the probability for PEP violation for electron is 4.7 $\times10^{-29}$ set by the VIP experiment. With upgraded detectors for high precision X-ray spectroscopy, the VIP-2 experiment will improve the sensitivity by two orders of magnitude.
△ Less
Submitted 21 January, 2016;
originally announced January 2016.
-
Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser
Authors:
L. Gruber,
S. E. Brunner,
C. Curceanu,
J. Marton,
A. Romero Vidal,
A. Scordo,
K. Suzuki,
O. Vazquez Doce
Abstract:
We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few…
▽ More
We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context, the influence of after-pulsing, cross-talk and dark-noise on the recovery process can be studied.
△ Less
Submitted 23 October, 2015;
originally announced October 2015.
-
VIP 2: Experimental tests of the Pauli Exclusion Principle for electrons
Authors:
A. Pichler,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. D`Uffizi,
J. P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
J. Marton,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
E. Sbardella,
A. Scordo,
H. Shi,
D. Sirghi
, et al. (5 additional authors not shown)
Abstract:
Many experiments investigated the violation of the Pauli Exclusion Principle (PEP) since its discovery in 1925. The VIP (VIolation of the Pauli Principle) experiment tested the PEP by measuring the probability for an external electron to be captured and undergo a 2p to 1s transition during its cascading process, where the 1s state is already occupied by two electrons. This transition is forbidden…
▽ More
Many experiments investigated the violation of the Pauli Exclusion Principle (PEP) since its discovery in 1925. The VIP (VIolation of the Pauli Principle) experiment tested the PEP by measuring the probability for an external electron to be captured and undergo a 2p to 1s transition during its cascading process, where the 1s state is already occupied by two electrons. This transition is forbidden by the Pauli Exclusion Principle. The VIP experiment resulted in a preliminary upper limit for the probability of the violation of the PEP of 4.7 x 10^{-29}. Currently a setup for the follow-up experiment VIP 2 is under preparation. The goal of this experiment is to improve the upper limit for the violation of the PEP by two orders of magnitude, by different improvements like enhanced energy resolution of the X-ray detectors and by implementing an active shielding. Here we report currently ongoing performance tests of the new parts of the setup.
△ Less
Submitted 12 May, 2015;
originally announced May 2015.
-
High sensitivity tests of the Pauli Exclusion Principle with VIP2
Authors:
J. Marton,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
C. Curceanu,
A. Clozza,
S. Di Matteo,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
E. Milotti,
A. Pichler,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
A. Scordo,
H. Shi,
D. L. Sirghi,
F. Sirghi,
L. Sperandio,
O. Vazquez Doce
, et al. (2 additional authors not shown)
Abstract:
The Pauli Exclusion Principle is one of the most fundamental rules of nature and represents a pillar of modern physics. According to many observations the Pauli Exclusion Principle must be extremely well fulfilled. Nevertheless, numerous experimental investigations were performed to search for a small violation of this principle. The VIP experiment at the Gran Sasso underground laboratory searched…
▽ More
The Pauli Exclusion Principle is one of the most fundamental rules of nature and represents a pillar of modern physics. According to many observations the Pauli Exclusion Principle must be extremely well fulfilled. Nevertheless, numerous experimental investigations were performed to search for a small violation of this principle. The VIP experiment at the Gran Sasso underground laboratory searched for Pauli-forbidden X-ray transitions in copper atoms using the Ramberg-Snow method and obtained the best limit so far. The follow-up experiment VIP2 is designed to reach even higher sensitivity. It aims to improve the limit by VIP by orders of magnitude. The experimental method, comparison of different PEP tests based on different assumptions and the developments for VIP2 are presented.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
Measurement of the strong interaction induced shift and width of the 1s state of kaonic deuterium at J-PARC
Authors:
J. Zmeskal,
M. Sato,
S. Ajimura,
M. Bazzi,
G. Beer,
C. Berucci,
H. Bhang,
D. Bosnar,
M. Bragadireanu,
P. Buehler,
L. Busso,
M. Cargnelli,
S. Choi,
A. Clozza,
C. Curceanu,
A. D'uffizi,
S. Enomoto,
L. Fabbietti,
D. Faso,
C. Fiorini,
H. Fujioka,
F. Ghio,
R. Golser,
C. Guaraldo,
T. Hashimoto
, et al. (52 additional authors not shown)
Abstract:
The antikaon-nucleon interaction close to threshold provides crucial information on the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. In this context the importance of kaonic deuterium X-ray spectroscopy has been well recognized, but no experimental results have yet been obtained due to the difficulty of the measurement. We propose to measure the shift and…
▽ More
The antikaon-nucleon interaction close to threshold provides crucial information on the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. In this context the importance of kaonic deuterium X-ray spectroscopy has been well recognized, but no experimental results have yet been obtained due to the difficulty of the measurement. We propose to measure the shift and width of the kaonic deuterium 1s state with an accuracy of 60 eV and 140 eV respectively at J-PARC. These results together with the kaonic hydrogen data (KpX at KEK, DEAR and SIDDHARTA at DAFNE) will then permit the determination of values of both the isospin I=0 and I=1 antikaon-nucleon scattering lengths and will provide the most stringent constraints on the antikaon-nucleon interaction, promising a breakthrough. Refined Monte Carlo studies were performed, including the investigation of background suppression factors for the described setup. These studies have demonstrated the feasibility of determining the shift and width of the kaonic deuterium atom 1s state with the desired accuracy of 60 eV and 140 eV.
△ Less
Submitted 22 January, 2015;
originally announced January 2015.
-
Beyond quantum mechanics? Hunting the 'impossible' atoms (Pauli Exclusion Principle violation and spontaneous collapse of the wave function at test)
Authors:
K. Piscicchia,
C. Curceanu,
S. Bartalucci,
A. Bassi,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
L. De Paolis,
S. Di Matteo,
S. Donadi,
A. d'Uffizi,
J-P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
J. Marton,
E. Milotti,
D. Pietreanu,
T. Ponta,
E. Sbardella,
A. Scordo,
H. Shi
, et al. (5 additional authors not shown)
Abstract:
The development of mathematically complete and consistent models solving the so-called "measurement problem", strongly renewed the interest of the scientific community for the foundations of quantum mechanics, among these the Dynamical Reduction Models posses the unique characteristic to be experimentally testable. In the first part of the paper an upper limit on the reduction rate parameter of su…
▽ More
The development of mathematically complete and consistent models solving the so-called "measurement problem", strongly renewed the interest of the scientific community for the foundations of quantum mechanics, among these the Dynamical Reduction Models posses the unique characteristic to be experimentally testable. In the first part of the paper an upper limit on the reduction rate parameter of such models will be obtained, based on the analysis of the X-ray spectrum emitted by an isolated slab of germanium and measured by the IGEX experiment.
The second part of the paper is devoted to present the results of the VIP (Violation of the Pauli exclusion principle) experiment and to describe its recent upgrade. The VIP experiment established a limit on the probability that the Pauli Exclusion Principle (PEP) is violated by electrons, using the very clean method of searching for PEP forbidden atomic transitions in copper.
△ Less
Submitted 19 January, 2015;
originally announced January 2015.
-
Testing the Pauli Exclusion Principle for electrons at LNGS
Authors:
H. Shi,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
A. M. Bragadireanu,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
S. Di Matteo,
A. d'Uffizi,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
J. Marton,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Piscicchia,
T. Ponta,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. L. Sirghi
, et al. (5 additional authors not shown)
Abstract:
High-precision experiments have been done to test the Pauli exclusion principle (PEP) for electrons by searching for anomalous $K$-series X-rays from a Cu target supplied with electric current. With the highest sensitivity, the VIP (VIolation of Pauli Exclusion Principle) experiment set an upper limit at the level of $10^{-29}$ for the probability that an external electron captured by a Cu atom ca…
▽ More
High-precision experiments have been done to test the Pauli exclusion principle (PEP) for electrons by searching for anomalous $K$-series X-rays from a Cu target supplied with electric current. With the highest sensitivity, the VIP (VIolation of Pauli Exclusion Principle) experiment set an upper limit at the level of $10^{-29}$ for the probability that an external electron captured by a Cu atom can make the transition from the 2$p$ state to a 1$s$ state already occupied by two electrons. In a follow-up experiment at Gran Sasso, we aim to increase the sensitivity by two orders of magnitude. We show proofs that the proposed improvement factor is realistic based on the results from recent performance tests of the detectors we did at Laboratori Nazionali di Frascati (LNF).
△ Less
Submitted 7 May, 2014;
originally announced May 2014.
-
A GEM-based Time Projection Chamber for the AMADEUS experiment
Authors:
M. Poli Lener,
M. Bazzi,
G. Corradi,
C. Curceanu,
A. D'Uffizi,
C. Paglia,
E. Sbardella,
A. Scordo,
D. Tagnani,
A. Romero Vidal,
J. Zmeskal
Abstract:
In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primar…
▽ More
In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primary vertex and the secondary particles tracking. A 10x10 cm2 prototype with a drift gap up to 15 cm was realized and succesfully tested at the π M1 beam facility of the Paul Scherrer Institut (PSI) with low momentum hadrons. The measurements of the detector efficiency and spatial resolution have been performed. The results as a function of the gas gain, drift field, front-end electronic threshold and particle momentum are reported and discussed.
△ Less
Submitted 23 April, 2013;
originally announced April 2013.
-
Testing the Pauli Exclusion Principle for Electrons
Authors:
J. Marton,
S. Bartalucci,
S. Bertolucci,
C. Berucci,
M. Bragadireanu,
M. Cargnelli,
C. Curceanu,
S. Di Matteo,
J. -P. Egger,
C. Guaraldo,
M. Iliescu,
T. Ishiwatari,
M. Laubenstein,
E. Milotti,
D. Pietreanu,
K. Pisciccia,
T. Ponta,
A. Romero-Vidal,
A. Scordo,
D. L. Sirghi,
F. Sirghi,
L. Sperandio,
O. Vazquez Doce,
E. Widmann,
J. Zmeskal
Abstract:
One of the fundamental rules of nature and a pillar in the foundation of quantum theory and thus of modern physics is represented by the Pauli Exclusion Principle. We know that this principle is extremely well fulfilled due to many observations. Numerous experiments were performed to search for tiny violation of this rule in various systems. The experiment VIP at the Gran Sasso underground laborat…
▽ More
One of the fundamental rules of nature and a pillar in the foundation of quantum theory and thus of modern physics is represented by the Pauli Exclusion Principle. We know that this principle is extremely well fulfilled due to many observations. Numerous experiments were performed to search for tiny violation of this rule in various systems. The experiment VIP at the Gran Sasso underground laboratory is searching for possible small violations of the Pauli Exclusion Principle for electrons leading to forbidden X-ray transitions in copper atoms. VIP is aiming at a test of the Pauli Exclusion Principle for electrons with high accuracy, down to the level of 10$^{-29}$ - 10$^{-30}$, thus improving the previous limit by 3-4 orders of magnitude. The experimental method, results obtained so far and new developments within VIP2 (follow-up experiment at Gran Sasso, in preparation) to further increase the precision by 2 orders of magnitude will be presented.
△ Less
Submitted 6 May, 2013; v1 submitted 28 February, 2013;
originally announced February 2013.
-
Performances of a GEM-based Time Projection Chamber prototype for the AMADEUS experiment
Authors:
M. Poli Lener,
M. Bazzi,
G. Corradi,
C. Curceanu,
A. D'Uffizi,
C. Paglia,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. Tagnani,
J. Zmeskal
Abstract:
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potent…
▽ More
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potential to improve TPC performances when used as amplification device. In this paper we present the R&D activity on a new GEM-based TPC detector built as a prototype for the inner part for AMADEUS, a new experimental proposal at the DAFNE collider at Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. In order to evaluate the GEM-TPC performances, a 10x10 cm2 prototype with a drift gap up to 15 cm has been realized. The detector was tested at the pM1 beam facility of the Paul Scherrer Institut (PSI) with low momentum pions and protons, without magnetic field. Drift properties of argonisobutane gas mixtures are measured and compared withMagboltz prediction. Detection efficiency and spatial resolution as a function of a large number of parameters, such as the gas gain, the drift field, the front-end electronic threshold and particle momentum, are illustrated and discussed. Particle identification capability and the measurement of the energy resolution in isobutane-based gas mixture are also reported.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Characterization of a scintillating fibers read by MPPC detectors trigger prototype for the AMADEUS experiment
Authors:
A. Scordo,
M. Bazzi,
C. Berucci,
C. Curceanu,
A. D'Uffizi,
K. Piscicchia,
M. Poli Lener,
A. Romero Vidal,
E. Sbardella,
O. Vazquez Doce
Abstract:
Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors ar…
▽ More
Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors are planned to be used to trigger on charged kaon pairs. In order to investigate the detection efficiency of such a system, a prototype setup consisting of 32, 1 mm diameter scintillating fibers, arranged in two double layers of 16 fibers each, and read out by 64 MPPCs with an ad-hoc built readout electronics, was tested at the piM-1 line of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection efficiency and the trigger capability were measured on a beam containing protons, electrons, muons and pions with a momentum of 440 MeV/c. The measured average efficiency for protons for a double layer of scintillating fibers (96.9 +/-1.2%) represents a guarantee of the good performance of this system as a trigger for the AMADEUS experiment.
△ Less
Submitted 7 May, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.
-
The K1.8BR spectrometer system at J-PARC
Authors:
Keizo Agari,
Shuhei Ajimura,
George Beer,
Hyoungchan Bhang,
Mario Bragadireanu,
Paul Buehler,
Luigi Busso,
Michael Cargnelli,
Seonho Choi,
Catalina Curceanu,
Shun Enomoto,
Diego Faso,
Hiroyuki Fujioka,
Yuya Fujiwara,
Tomokazu Fukuda,
Carlo Guaraldo,
Tadashi Hashimoto,
Ryugo S. Hayano,
Toshihiko Hiraiwa,
Erina Hirose,
Masaharu Ieiri,
Masami Iio,
Mihai Iliescu,
Kentaro Inoue,
Yosuke Ishiguro
, et al. (60 additional authors not shown)
Abstract:
A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from th…
▽ More
A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.
△ Less
Submitted 21 November, 2012; v1 submitted 1 June, 2012;
originally announced June 2012.