ZynqMP-based board-management mezzanines for Serenity ATCA-blades
Authors:
T. Mehner,
L. E. Ardila-Perez,
M. N. Balzer,
O. Sander,
D. Tcherniakhovski,
M. Schleicher,
M. Fuchs,
G. Fedi,
G. Gimas,
G. M. Iles,
M. Pesaresi,
A. W. Rose,
T. Schuh
Abstract:
In the context of the CMS Phase-2 tracker back-end processing system, two mezzanines based on the Zynq Ultrascale+ Multi-Processor System-on-Chip (MPSoC) device have been developed to serve as centralized slow control and board management solution for the Serenity-family \textcolor{black}{Advanced Telecommunications Computing Architecture (ATCA)} blades.
This paper presents the developments of t…
▽ More
In the context of the CMS Phase-2 tracker back-end processing system, two mezzanines based on the Zynq Ultrascale+ Multi-Processor System-on-Chip (MPSoC) device have been developed to serve as centralized slow control and board management solution for the Serenity-family \textcolor{black}{Advanced Telecommunications Computing Architecture (ATCA)} blades.
This paper presents the developments of the MPSoC mezzanines to execute the Intelligent Platform Management Controller (IPMC) software in the real-time capable processors of the MPSoC. In coordination with the Shelf Manager, once full-power is enabled, a CentOS-based Linux distribution is executed in the application processors of the MPSoC, on which EMPButler and the Serenity Management Shell (SMASH) are running.
△ Less
Submitted 4 April, 2024;
originally announced April 2024.
-
Lessons learned while developing the Serenity-S1 ATCA card
Authors:
T. Mehner,
L. E. Ardila-Perez,
M. Balzer,
G. Fedi,
M. Fuchs,
A. Howard,
G. Iles,
M. Loutit,
S. Mansbridge,
F. Palla,
D. Parker,
M. Pesaresi,
A. Rose,
M. Saleh,
O. Sander,
M. Schleicher,
C. Strohman,
D. Tcherniakhovski,
T. Williams,
J. Zhao
Abstract:
The Serenity-S1 is a Xilinx Virtex Ultrascale+ based Advanced Telecommunications Computing Architecture (ATCA) processing blade that has been optimised for production. It incorporates many developments from the Serenity-A and Serenity-Z prototype cards and, where possible, adopts solutions being used across CERN. It also uses many new parts because commonly used parts have disappeared from the mar…
▽ More
The Serenity-S1 is a Xilinx Virtex Ultrascale+ based Advanced Telecommunications Computing Architecture (ATCA) processing blade that has been optimised for production. It incorporates many developments from the Serenity-A and Serenity-Z prototype cards and, where possible, adopts solutions being used across CERN. It also uses many new parts because commonly used parts have disappeared from the market during the semiconductor crisis, with only some returning.
Improvements to simplify manufacture, the performance of new components, some of the more difficult aspects of procurement, the performance of production-grade Samtec 25\,Gb/s optical firefly parts, and issues with the rack cooling infrastructure are discussed.
△ Less
Submitted 14 December, 2023; v1 submitted 3 November, 2023;
originally announced November 2023.
-
Design of a mobile neutron spectrometer for the Laboratori Nazionali del Gran Sasso (LNGS)
Authors:
Melih Solmaz,
Klaus Eitel,
Kathrin Valerius,
Matthias Balzer,
Alfredo Ferella,
Francesco Pompa,
Ulrich Pirling,
Denis Tcherniakhovski,
Uwe Oberlack,
Sascha Wüstling
Abstract:
Environmental neutrons are a source of background for rare event searches (e.g., dark matter direct detection and neutrinoless double beta decay experiments) taking place in deep underground laboratories. The overwhelming majority of these neutrons are produced in the cavern walls by means of intrinsic radioactivity of the rock and concrete. Their flux and spectrum depend on time and location. Pre…
▽ More
Environmental neutrons are a source of background for rare event searches (e.g., dark matter direct detection and neutrinoless double beta decay experiments) taking place in deep underground laboratories. The overwhelming majority of these neutrons are produced in the cavern walls by means of intrinsic radioactivity of the rock and concrete. Their flux and spectrum depend on time and location. Precise knowledge of this background is necessary to devise sufficient shielding and veto mechanisms, improving the sensitivity of the neutron-susceptible underground experiments. In this report, we present the design and the expected performance of a mobile neutron detector for the LNGS underground laboratory. The detector is based on capture-gated spectroscopy technique and comprises essentially a stack of plastic scintillator bars wrapped by gadolinium foils. The extensive simulation studies demonstrate that the detector will be capable of measuring ambient neutrons at low flux levels ($\sim$$10^{-6}\,\mathrm{n/cm^2/s}$) at LNGS, where the ambient gamma flux is by about 5 orders of magnitude larger.
△ Less
Submitted 7 November, 2023; v1 submitted 13 July, 2023;
originally announced July 2023.
-
Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger
, et al. (110 additional authors not shown)
Abstract:
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectromet…
▽ More
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $β$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $σ(m_ν^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Suppression of Penning discharges between the KATRIN spectrometers
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (129 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space b…
▽ More
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.
△ Less
Submitted 17 September, 2020; v1 submitted 21 November, 2019;
originally announced November 2019.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
Gamma-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (101 additional authors not shown)
Abstract:
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test th…
▽ More
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.
△ Less
Submitted 10 July, 2019; v1 submitted 1 March, 2019;
originally announced March 2019.
-
Searches for electron interactions induced by new physics in the EDELWEISS-III germanium bolometers
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
J. Gascon,
A. Giuliani,
M. Gros,
Y. Jin,
A. Juillard,
M. Kleifges,
V. Kozlov,
H. Kraus,
V. A. Kudryavtsev,
H. Le-Sueur,
R. Maisonobe,
S. Marnieros
, et al. (17 additional authors not shown)
Abstract:
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters…
▽ More
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on the electron lifetime decaying to invisibles, $τ> 1.2\times 10^{24}$ years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters $g_{ae}<1.1\times 10^{-11}$ and $g_{ae}\times g_{aN}^{\rm eff} < 3.5\times 10^{-17}$ at 90% C.L. in the massless limit. We also directly search for the absorption of bosonic dark matter particles that would constitute our local galactic halo. Limits are placed on the couplings of ALPs or hidden photon dark matter in the mass range $0.8 - 500$ keV/c$^2$. Prospects for searching for dark matter particles with masses down to 150 eV/c$^2$ using improved detectors are presented.
△ Less
Submitted 5 November, 2018; v1 submitted 7 August, 2018;
originally announced August 2018.
-
Performance of the EDELWEISS-III experiment for direct dark matter searches
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
T. de Boissière,
G. Bres,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Foerster,
N. Fourches,
G. Garde,
J. Gascon,
A. Giuliani,
M. Grollier
, et al. (38 additional authors not shown)
Abstract:
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used…
▽ More
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $β$- and $α$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $α$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $γ$-ray events has been demonstrated using $γ$-calibrations with $^{133}$Ba sources leading to a value of $R_{γ{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $γ$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.
△ Less
Submitted 4 June, 2017;
originally announced June 2017.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
Measurement of the cosmogenic activation of germanium detectors in EDELWEISS-III
Authors:
The EDELWEISS Collaboration,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
G. Heuermann,
Y. Jin,
A. Juillard
, et al. (24 additional authors not shown)
Abstract:
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for…
▽ More
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for $^{65}$Zn. These results are the most accurate for these isotopes. A lower limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also presented. They are compared to model predictions present in literature and to estimates calculated with the ACTIVIA code.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach
Authors:
EDELWEISS Collaboration,
L. Hehn,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
M. De Jésus,
L. Dumoulin,
K. Eitel,
N. Foerster,
J. Gascon,
A. Giuliani,
M. Gros,
G. Heuermann,
Y. Jin,
A. Juillard
, et al. (24 additional authors not shown)
Abstract:
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoi…
▽ More
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_χ\in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $γ$- and $β$-radiation, recoils from $^{206}$Pb and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on Boosted Decision Trees (BDT). For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90% C.L. exclusion limit set for WIMPs with $m_χ= 4\,\mathrm{GeV/}c^2$ is $1.6 \times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above $15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in good agreement.
△ Less
Submitted 20 September, 2016; v1 submitted 12 July, 2016;
originally announced July 2016.
-
Signals induced by charge-trapping in EDELWEISS FID detectors: analytical modeling and applications
Authors:
The EDELWEISS Collaboration,
Q. Arnaud,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Billard,
J. Blümer,
T. de Boissière,
A. Broniatowski,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
L. Dumoulin,
K. Eitel,
N. Foerster,
N. Fourches,
J. Gascon,
A. Giuliani,
M. Gros,
L. Hehn,
G. Heuermann,
M. De Jésus,
Y. Jin
, et al. (25 additional authors not shown)
Abstract:
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trapping significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID…
▽ More
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trapping significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID detectors based on the Shockley-Ramo theorem. It is used to demonstrate that veto electrodes, initially designed for the sole purpose of surface event rejection, can be used to provide a sensitivity to the depth of the energy deposits, characterize the trapping in the crystals, perform heat and ionization energy corrections and improve the ionization baseline resolutions. These procedures are applied successfully to actual data.
△ Less
Submitted 29 June, 2016; v1 submitted 26 June, 2016;
originally announced June 2016.
-
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
Authors:
EDELWEISS Collaboration,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
J. Blümer,
T. de Boissière,
G. Bres,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Foerster,
N. Fourches,
G. Garde,
J. Gascon
, et al. (42 additional authors not shown)
Abstract:
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear rec…
▽ More
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an illustration the number of observed events in the search for 5 (resp. 20) GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1 (resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times 10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a 41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints of WIMP signals from some recent experiments, thus confirming results obtained with different detection techniques.
△ Less
Submitted 9 May, 2016; v1 submitted 16 March, 2016;
originally announced March 2016.
-
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO$_4$ scintillating bolometers
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
A. Benoit,
L. Berge,
R. S. Boiko,
T. Bergmann,
J. Blumer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
F. A. Danevich,
T. de Boissiere,
R. Decourt,
M. De Jesus,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin
, et al. (69 additional authors not shown)
Abstract:
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very prom…
▽ More
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very promising for the recognition and rejection of background events. We present the LUMINEU concepts and the experimental results achieved aboveground and underground with large-mass natural and enriched crystals. The measured energy resolution, the $α/β$ discrimination power and the radioactive internal contamination are all within the specifications for the projected final LUMINEU sensitivity. Simulations and preliminary results confirm that the LUMINEU technology can reach zero background in the region of interest (around 3 MeV) with exposures of the order of hundreds kg$\times$years, setting the bases for a next generation $0\nu2β$ decay experiment capable to explore the inverted hierarchy region of the neutrino mass pattern.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Scintillating bolometers based on ZnMoO$_4$ and Zn$^{100}$MoO$_4$ crystals to search for 0$ν$2$β$ decay of $^{100}$Mo (LUMINEU project): first tests at the Modane Underground Laboratory
Authors:
D. V. Poda,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
R. S. Boiko,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
B. Censier,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
G. A. Cox,
F. A. Danevich,
T. de Boissière,
R. Decourt,
M. De Jesus
, et al. (69 additional authors not shown)
Abstract:
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed…
▽ More
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed and Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time by using the low-thermal-gradient Czochralski technique. One ZnMoO$_4$ scintillator and two samples (59 g and 63 g) cut from the enriched boule were tested aboveground at milli-Kelvin temperature as scintillating bolometers showing a high detection performance. The first results of the low background measurements with three ZnMoO$_4$ and two enriched detectors installed in the EDELWEISS set-up at the Modane Underground Laboratory (France) are presented.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
Focal-plane detector system for the KATRIN experiment
Authors:
J. F. Amsbaugh,
J. Barrett,
A. Beglarian,
T. Bergmann,
H. Bichsel,
L. I. Bodine,
J. Bonn,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
S. Chilingaryan,
T. J. Corona,
P. J. Doe,
J. A. Dunmore,
S. Enomoto,
J. Fischer,
J. A. Formaggio,
F. M. Fränkle,
D. Furse,
H. Gemmeke,
F. Glück,
F. Harms,
G. C. Harper,
J. Hartmann,
M. A. Howe
, et al. (26 additional authors not shown)
Abstract:
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electro…
▽ More
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
△ Less
Submitted 28 January, 2015; v1 submitted 10 April, 2014;
originally announced April 2014.
-
Background studies for the EDELWEISS dark matter experiment
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couedo,
P. Coulter,
G. A. Cox,
M. De Jesus,
J. Domange,
A. -A. Drilien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
M. Gros
, et al. (34 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present h…
▽ More
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of 1.0-3.1 events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events ($\le0.9$), surface betas ($\le0.3$), and muon-induced neutrons ($\le0.7$), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as 14-44 events/kg/day and 0.7-1.4 events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected rate of background events in the next phase of the experiment.
△ Less
Submitted 15 May, 2013;
originally announced May 2013.
-
Muon-induced background in the EDELWEISS dark matter search
Authors:
The EDELWEISS collaboration,
B. Schmidt,
E. Armengaud,
C. Augier,
A. Benoit,
L. Bergé,
T. Bergmann,
J. Blümer,
G. Bres,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
S. Collin,
P. Coulter,
G. A. Cox,
O. Crauste,
J. Domange,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
G. Garde,
J. Gascon
, et al. (33 additional authors not shown)
Abstract:
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $Φ_μ=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the…
▽ More
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $Φ_μ=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the determination of the angular dependent muon flux in LSM. The results are in good agreement with both MC simulations and earlier measurements. Synchronization of the muon-veto system with the phonon and ionization signals of the Ge detector array allowed identification of muon-induced events. Rates for all muon-induced events $Γ^μ=(0.172 \pm 0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $Γ^{μ-n} = 0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After vetoing, the remaining rate of accepted muon-induced neutrons in the EDELWEISS-II dark matter search was determined to be $Γ^{μ-n}_{\rm irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on these results, the muon-induced background expectation for an anticipated exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{μ-n}_{3000 kg\cdot d} < 0.6$ events.
△ Less
Submitted 28 February, 2013;
originally announced February 2013.
-
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
Authors:
EDELWEISS Collaboration,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couëdo,
P. Coulter,
G. A. Cox,
J. Domange,
A. A. Drillien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
J. Gironnet,
M. Gros
, et al. (30 additional authors not shown)
Abstract:
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed…
▽ More
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.
△ Less
Submitted 5 September, 2012; v1 submitted 7 July, 2012;
originally announced July 2012.