-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging
Authors:
Kurt G Schilling,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Lucio Frydman,
Yohan van de Looij,
David Hike,
Jeff F Dunn
, et al. (31 additional authors not shown)
Abstract:
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contras…
▽ More
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contrasts for improved microstructure and connectivity characterization. Another major advantage is direct comparison with histological data as a crucial methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging, but ultimately affect what questions can be answered using the data. This work represents 'Part 2' of a series of recommendations and considerations for preclinical dMRI, where we focus on best practices for dMRI of ex vivo tissue. We first describe the value that ex vivo imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We then give guidelines for ex vivo protocols, including tissue preparation, imaging sequences and data processing including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available ex vivo dMRI datasets and dedicated software packages. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist, and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 7 February, 2023; v1 submitted 27 September, 2022;
originally announced September 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 -- In vivo small-animal imaging
Authors:
Ileana O Jelescu,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, anal…
▽ More
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the data. This work aims to serve as a reference, presenting selected recommendations and guidelines from the diffusion community, on best practices for preclinical dMRI of in vivo animals. In each section, we also highlight areas for which no guidelines exist (and why), and where future work should focus. We first describe the value that small animal imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss how they are appropriate for different studies. We then give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, imaging sequences and data processing, including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available preclinical dMRI datasets and software packages, to promote responsible and reproducible research. An overarching goal herein is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 21 April, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
Modelling an equivalent b-value in diffusion-weighted steady-state free precession
Authors:
Benjamin C. Tendler,
Sean Foxley,
Michiel Cottaar,
Saad Jbabdi,
Karla Miller
Abstract:
Purpose: Diffusion-weighted steady-state free precession (DW-SSFP) is shown to provide a means to probe non-Gaussian diffusion through manipulation of the flip angle. A framework is presented to define an effective b-value in DW-SSFP. Theory: The DW-SSFP signal is a summation of coherence pathways with different b-values. The relative contribution of each pathway is dictated by the flip angle. Thi…
▽ More
Purpose: Diffusion-weighted steady-state free precession (DW-SSFP) is shown to provide a means to probe non-Gaussian diffusion through manipulation of the flip angle. A framework is presented to define an effective b-value in DW-SSFP. Theory: The DW-SSFP signal is a summation of coherence pathways with different b-values. The relative contribution of each pathway is dictated by the flip angle. This leads to an apparent diffusion coefficient (ADC) estimate that depends on the flip angle in non-Gaussian diffusion regimes. By acquiring DW-SSFP data at multiple flip angles and modelling the variation in ADC for a given form of non-Gaussianity, the ADC can be estimated at a well-defined effective b-value. Methods: A gamma distribution is used to model non-Gaussian diffusion, embedded in the Buxton signal model for DW-SSFP. Monte-Carlo simulations of non-Gaussian diffusion in DW-SSFP and diffusion-weighted spin-echo (DW-SE) sequences are used to verify the proposed framework. Dependence of ADC on flip angle in DW-SSFP is verified with experimental measurements in a whole, human post-mortem brain. Results: Monte-Carlo simulations reveal excellent agreement between ADCs estimated with DW-SE and the proposed framework. Experimental ADC estimates vary as a function of flip angle over the corpus callosum of the postmortem brain, estimating the mean and standard deviation of the gamma distribution as $1.50\cdot 10^{-4} mm^2/s$ and $2.10\cdot 10^{-4} mm^2/s$. Conclusion: DW-SSFP can be used to investigate non-Gaussian diffusion by varying the flip angle. By fitting a model of non-Gaussian diffusion, the ADC in DW-SSFP can be estimated at an effective b-value, comparable to more conventional diffusion sequences.
△ Less
Submitted 4 November, 2019;
originally announced November 2019.