-
A prototype detector for the CRESST-III low-mass dark matter search
Authors:
R. Strauss,
G. Angloher,
P. Bauer,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
R. Hampf,
D. Hauff,
M. Kiefer,
J. -C. Lanfranchi,
A. Langenkämper,
E. Mondragon,
A. Münster,
C. Oppenheimer,
F. Petricca,
W. Potzel,
F. Pröbst,
F. Reindl,
J. Rothe,
S. Schönert,
W. Seidel,
H. Steiger,
L. Stodolsky,
A. Tanzke
, et al. (6 additional authors not shown)
Abstract:
The CRESST-III experiment which is dedicated to low-mass dark matter search uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors. Background discrimination is achieved by exploiting the scintillating light signal of CaWO$_4$ and by a novel active detector holder presented in this paper. In a test setup above ground, a nuclear-recoil energy threshold of…
▽ More
The CRESST-III experiment which is dedicated to low-mass dark matter search uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors. Background discrimination is achieved by exploiting the scintillating light signal of CaWO$_4$ and by a novel active detector holder presented in this paper. In a test setup above ground, a nuclear-recoil energy threshold of $E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which corresponds to an estimated threshold of $\sim$50eV when being operated in the low-noise CRESST cryostat. This is the lowest threshold reported for direct dark matter searches. For CRESST-III phase 1, ten such detector modules were installed in the cryostat which have the potential to improve significantly the sensitivity to scatterings of dark matter particles with masses down to $\sim$0.1GeV/c$^2$.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Performance of a CRESST-II Detector Module with True $4π$-veto
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. C. Lanfranchi,
A. Langenkämper,
J. Loebell,
M. Mancuso,
A. Münster,
C. Pagliarone,
F. Petricca,
W. Potzel,
F. Pröbst
, et al. (20 additional authors not shown)
Abstract:
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this detector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the fram…
▽ More
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this detector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the framework of the CRESST-II experiment, we developed and successfully tested a novel detector design addressing both challenges. Using a large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber, the signal height recorded in the light channel is improved by a factor 2.5 compared to conventional CRESTT-II detector modules. In combination with a large carrier crystal, a true $4π$ veto system is established which allows to tag external background sources.
△ Less
Submitted 4 August, 2017;
originally announced August 2017.
-
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
A. Langenkämper J. Loebell,
M. Mancuso,
E. Mondragon,
A. Münster,
L. Oberauer,
C. Pagliarone,
F. Petricca,
W. Potzel
, et al. (22 additional authors not shown)
Abstract:
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $ν$-cleus e…
▽ More
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the $ν$-cleus experiment has achieved an energy threshold of $E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous results and independent of the type of particle interaction. The result presented here is obtained in a setup above ground without significant shielding against ambient and cosmogenic radiation. Although operated in a high-background environment, the detector probes a new range of light-mass dark matter particles previously not accessible by direct searches. We report the first limit on the spin-independent dark matter particle-nucleon cross section for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
△ Less
Submitted 18 September, 2017; v1 submitted 20 July, 2017;
originally announced July 2017.
-
Low-Temperature Relative Reflectivity Measurements of Reflective and Scintillating Foils used in Rare Event Searches
Authors:
A. Langenkämper,
A. Ulrich,
X. Defay,
F. v. Feilitzsch,
J. -C. Lanfranchi,
E. Mondragón,
A. Münster,
C. Oppenheimer,
W. Potzel,
S. Roth,
S. Schönert,
H. Steiger,
H. H. Trinh Thi,
S. Wawoczny,
M. Willers,
A. Zöller
Abstract:
In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO$_4$ crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the…
▽ More
In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO$_4$ crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO$_4$ target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay ($0νββ$). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no significant change in the reflectivity with temperature for all foils studied.
△ Less
Submitted 20 December, 2017; v1 submitted 21 March, 2017;
originally announced March 2017.
-
Description of CRESST-II data
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
C. Kistner,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
J. Loebell,
M. Mancuso,
A. Münster,
C. Pagliarone,
F. Petricca,
W. Potzel,
F. Pröbst
, et al. (25 additional authors not shown)
Abstract:
In Phase 2 of CRESST-II 18 detector modules were operated for about two years (July 2013 - August 2015). Together with this document we are publishing data from two detector modules which have been used for direct dark-matter searches. With these data-sets we were able to set world-leading limits on the cross section for spin-independent elastic scattering of dark matter particles off nuclei. We p…
▽ More
In Phase 2 of CRESST-II 18 detector modules were operated for about two years (July 2013 - August 2015). Together with this document we are publishing data from two detector modules which have been used for direct dark-matter searches. With these data-sets we were able to set world-leading limits on the cross section for spin-independent elastic scattering of dark matter particles off nuclei. We publish the energies of all events within the acceptance regions for dark-matter searches. In addition, we also publish the energies of the events within the electron-recoil band. This data set can be used to study interactions with electrons of CaWO$_4$. In this document we describe how to use these data sets. In particular, we explain the cut-survival probabilities required for comparisons of models with the data sets.
△ Less
Submitted 23 August, 2017; v1 submitted 27 January, 2017;
originally announced January 2017.
-
Dark-Photon Search using Data from CRESST-II Phase 2
Authors:
G. Angloher,
P. Bauer,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. C. Lanfranchi,
J. Loebell,
M. Mancuso,
A. Münster,
C. Pagliarone,
F. Petricca,
W. Potzel,
F. Pröbst,
R. Puig
, et al. (18 additional authors not shown)
Abstract:
Identifying the nature and origin of dark matter is one of the major challenges for modern astro and particle physics. Direct dark-matter searches aim at an observation of dark-matter particles interacting within detectors. The focus of several such searches is on interactions with nuclei as provided e.g. by Weakly Interacting Massive Particles. However, there is a variety of dark-matter candidate…
▽ More
Identifying the nature and origin of dark matter is one of the major challenges for modern astro and particle physics. Direct dark-matter searches aim at an observation of dark-matter particles interacting within detectors. The focus of several such searches is on interactions with nuclei as provided e.g. by Weakly Interacting Massive Particles. However, there is a variety of dark-matter candidates favoring interactions with electrons rather than with nuclei. One example are dark photons, i.e., long-lived vector particles with a kinetic mixing to standard-model photons. In this work we present constraints on this kinetic mixing based on data from CRESST-II Phase 2 corresponding to an exposure before cuts of 52\,kg-days. These constraints improve the existing ones for dark-photon masses between 0.3 and 0.7\,keV/c$^2$.
△ Less
Submitted 15 May, 2017; v1 submitted 22 December, 2016;
originally announced December 2016.
-
Direct Dark Matter Search with the CRESST II Experiment
Authors:
J Schieck,
G Angloher,
A Bento,
C Bucci,
L Canonica,
X Defay,
A Erb,
F v Feilitzsch,
N Ferreiro Iachellini,
P Gorla,
A Guetlein,
D Hauff,
J Jochum,
M Kiefer,
H Kluck,
H Kraus,
J-C Lanfranchi,
J Loebell,
M Mancuso,
A Muenster,
C Pagliarone,
F Petricca,
W Potzel,
F Pröbst,
R Puig
, et al. (18 additional authors not shown)
Abstract:
The quest for the particle nature of dark matter is one of the big open questions of modern physics. A well motivated candidate for dark matter is the so-called WIMP - a weakly interacting massive particle. Recently several theoretically well-motivated models with dark matter candidates in a mass region below the WIMP mass-scale gained also a lot of interest, theoretically and experimentally. The…
▽ More
The quest for the particle nature of dark matter is one of the big open questions of modern physics. A well motivated candidate for dark matter is the so-called WIMP - a weakly interacting massive particle. Recently several theoretically well-motivated models with dark matter candidates in a mass region below the WIMP mass-scale gained also a lot of interest, theoretically and experimentally. The CRESST II experiment located at the Gran Sasso laboratory in Italy is optimised for the detection of the elastic scattering of these low-mass dark matter particles with ordinary matter. We show the results obtained with an improved detector setup with increased radio purity and enhanced background rejection and the results obtained with a dedicated low-threshold analysis of a single conventional detector module. The limit achieved is the most stringent limit achieved for direct dark matter experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the expected performance for new small CRESST-type detectors to be used during the next data taking phase. We conclude with an outlook of the future potential for direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic detectors.
△ Less
Submitted 7 November, 2016;
originally announced November 2016.
-
New Limits on Double Electron Capture of $^{40}$Ca and $^{180}$W
Authors:
G. Angloher,
M. Bauer,
P. Bauer,
I. Bavykina,
A. Bento,
C. Bucci,
L. Canonica,
C. Ciemniak,
X. Defay,
G. Deuter,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
P. Huff,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
J. Loebell
, et al. (31 additional authors not shown)
Abstract:
We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Dependin…
▽ More
We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these values improve the currently best limits by a factor of $\sim$1.4-30.
△ Less
Submitted 18 August, 2016; v1 submitted 28 April, 2016;
originally announced April 2016.
-
Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Calvo,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (124 additional authors not shown)
Abstract:
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible…
▽ More
During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.
△ Less
Submitted 17 August, 2016; v1 submitted 23 April, 2016;
originally announced April 2016.
-
Muon capture on light isotopes in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
T. Abrahão,
H. Almazan,
C. Alt,
S. Appel,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad
, et al. (122 additional authors not shown)
Abstract:
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stopping cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. T…
▽ More
Using the Double Chooz detector, designed to measure the neutrino mixing angle $θ_{13}$, the products of $μ^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stopping cosmic $μ^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, $β$-delayed neutrons. The most precise measurement of the rate of $^{12}\mathrm C(μ^-,ν)^{12}\mathrm B$ to date is reported: $6.57^{+0.11}_{-0.21}\times10^{3}\,\mathrm s^{-1}$, or $(17.35^{+0.35}_{-0.59})\%$ of nuclear captures. By tagging excited states emitting gammas, the ground state transition rate to $^{12}$B has been determined to be $5.68^{+0.14}_{-0.23}\times10^3\,\mathrm s^{-1}$. The heretofore unobserved reactions $^{12}\mathrm C(μ^-,να)^{8}\mathrm{Li}$, $^{13}\mathrm C(μ^-,ν\mathrm nα)^{8}\mathrm{Li}$, and $^{13}\mathrm C(μ^-,ν\mathrm n)^{12}\mathrm B$ are measured. Further, a population of $β$n decays following stopping muons is identified with $5.5σ$ significance. Statistics limit our ability to identify these decays definitively. Assuming negligible production of $^{8}$He, the reaction $^{13}\mathrm C(μ^-,να)^{9}\mathrm{Li}$ is found to be present at the $2.7σ$ level. Limits are set on a variety of other processes.
△ Less
Submitted 17 May, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
Measurement of $θ_{13}$ in Double Chooz using neutron captures on hydrogen with novel background rejection techniques
Authors:
Y. Abe,
S. Appel,
T. Abrahão,
H. Almazan,
C. Alt,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
R. Carr,
M. Cerrada,
E. Chauveau,
P. Chimenti,
A. P. Collin,
J. M. Conrad,
J. I. Crespo-Anadón
, et al. (120 additional authors not shown)
Abstract:
The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050…
▽ More
The Double Chooz collaboration presents a measurement of the neutrino mixing angle $θ_{13}$ using reactor $\overlineν_{e}$ observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. These improvements demonstrate the capability of precise measurement of reactor $\overlineν_{e}$ without gadolinium loading. Spectral distortions from the $\overlineν_{e}$ reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of $\sin^{2}2θ_{13} = 0.095^{+0.038}_{-0.039}$(stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of $\sin^{2}2θ_{13} = 0.088\pm0.033$(stat+syst).
△ Less
Submitted 28 December, 2015; v1 submitted 29 October, 2015;
originally announced October 2015.
-
The CRESST Dark Matter Search - Status and Perspectives
Authors:
The CRESST Collaboration,
F. Reindl,
G. Angloher,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. C. Lanfranchi,
J. Loebell,
A. Münster,
C. Pagliarone,
F. Petricca,
W. Potzel,
F. Pröbst,
K. Schäffner
, et al. (16 additional authors not shown)
Abstract:
In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unp…
▽ More
In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unprecedented background level for CaWO$_4$ target crystals render TUM40 the detector with the best overall performance of CRESST-II phase 2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate light dark matter particles (<3GeV/c$^2$), previously not accessible for other direct detection experiments.
△ Less
Submitted 30 September, 2015;
originally announced September 2015.
-
Results on light dark matter particles with a low-threshold CRESST-II detector
Authors:
The CRESST Collaboration,
G. Angloher,
A. Bento,
C. Bucci,
L. Canonica,
X. Defay,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
J. Jochum,
M. Kiefer,
H. Kluck,
H. Kraus,
J. C. Lanfranchi,
J. Loebell,
A. Münster,
C. Pagliarone,
F. Petricca,
W. Potzel,
F. Pröbst,
F. Reindl,
K. Schäffner
, et al. (16 additional authors not shown)
Abstract:
The CRESST-II experiment uses cryogenic detectors to search for nuclear recoil events induced by the elastic scattering of dark matter particles in CaWO$_4$ crystals. Given the low energy threshold of our detectors in combination with light target nuclei, low mass dark matter particles can be probed with high sensitivity. In this letter we present the results from data of a single detector module…
▽ More
The CRESST-II experiment uses cryogenic detectors to search for nuclear recoil events induced by the elastic scattering of dark matter particles in CaWO$_4$ crystals. Given the low energy threshold of our detectors in combination with light target nuclei, low mass dark matter particles can be probed with high sensitivity. In this letter we present the results from data of a single detector module corresponding to 52 kg live days. A blind analysis is carried out. With an energy threshold for nuclear recoils of 307 eV we substantially enhance the sensitivity for light dark matter. Thereby, we extend the reach of direct dark matter experiments to the sub-region and demonstrate that the energy threshold is the key parameter in the search for low mass dark matter particles.
△ Less
Submitted 12 February, 2016; v1 submitted 4 September, 2015;
originally announced September 2015.
-
Ortho-positronium observation in the Double Chooz Experiment
Authors:
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadon,
K. Crum,
A. S. Cucoanes
, et al. (121 additional authors not shown)
Abstract:
The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle…
▽ More
The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle identification, based on particle dependent time profile of photon emission in liquid scintillator, can not be used given the identical mass of the two particles. However, the positron annihilation is sometimes delayed by the ortho-positronium (o-Ps) metastable state formation, which induces a pulse shape distortion that could be used for positron identification. In this paper we report on the first observation of positronium formation in a large liquid scintillator detector based on pulse shape analysis of single events. The o-Ps formation fraction and its lifetime were measured, finding the values of 44$\%$ $\pm$ 12$\%$ (sys.) $\pm$ 5$\%$ (stat.) and $3.68$ns $\pm$ 0.17ns (sys.) $\pm$ 0.15ns (stat.) respectively, in agreement with the results obtained with a dedicated positron annihilation lifetime spectroscopy setup.
△ Less
Submitted 7 October, 2014; v1 submitted 25 July, 2014;
originally announced July 2014.
-
Improved measurements of the neutrino mixing angle $θ_{13}$ with the Double Chooz detector
Authors:
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum,
A. S. Cucoanes
, et al. (121 additional authors not shown)
Abstract:
The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect t…
▽ More
The Double Chooz experiment presents improved measurements of the neutrino mixing angle $θ_{13}$ using the data collected in 467.90 live days from a detector positioned at an average distance of 1050 m from two reactor cores at the Chooz nuclear power plant. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties with respect to previous publications, whereas the efficiency of the $\barν_{e}$ signal has increased. The value of $θ_{13}$ is measured to be $\sin^{2}2θ_{13} = 0.090 ^{+0.032}_{-0.029}$ from a fit to the observed energy spectrum. Deviations from the reactor $\barν_{e}$ prediction observed above a prompt signal energy of 4 MeV and possible explanations are also reported. A consistent value of $θ_{13}$ is obtained from a fit to the observed rate as a function of the reactor power independently of the spectrum shape and background estimation, demonstrating the robustness of the $θ_{13}$ measurement despite the observed distortion.
△ Less
Submitted 21 January, 2015; v1 submitted 30 June, 2014;
originally announced June 2014.
-
Precision Muon Reconstruction in Double Chooz
Authors:
Double Chooz collaboration,
Y. Abe,
J. C. dos Anjos,
J. C. Barriere,
E. Baussan,
I. Bekman,
M. Bergevin,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
E. Chauveau,
P. Chimenti,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (119 additional authors not shown)
Abstract:
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volu…
▽ More
We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.
△ Less
Submitted 15 August, 2014; v1 submitted 23 May, 2014;
originally announced May 2014.
-
Reactor electron antineutrino disappearance in the Double Chooz experiment
Authors:
Y. Abe,
C. Aberle,
J. C. dos Anjos,
J. C. Barriere,
M. Bergevin,
A. Bernstein,
T. J. C. Bezerra,
L. Bezrukhov,
E. Blucher,
N. S. Bowden,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
P. Chimenti,
T. Classen,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (140 additional authors not shown)
Abstract:
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted…
▽ More
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted as evidence of electron antineutrino disappearance. From a rate plus spectral shape analysis we find sin^2 2θ13 = 0.109 \pm 0.030(stat) \pm 0.025(syst). The data exclude the no-oscillation hypothesis at 99.8% CL (2.9σ).
△ Less
Submitted 30 August, 2012; v1 submitted 26 July, 2012;
originally announced July 2012.